• 제목/요약/키워드: Tool Alignment Error

검색결과 20건 처리시간 0.022초

Tooth modification of helical gears for minimization of vibration and noise

  • Chong, Tae-Hyong;Myong, Jae-Hyong;Kim, Ki-Tae
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제2권4호
    • /
    • pp.5-11
    • /
    • 2001
  • Vibration and noise of gears is doc to the transmission error and the vibration exciting force caused by the periodically alternating tooth stiffness. Transmission error is the rotation delay between driving and driven gear caused by manufacturing error, alignment error in assembly and so on. Tooth stiffness changes with the proceeding mesh of teeth. The purpose of this study is to develop how to calculate simultaneously the optimum amounts of tooth profile modification. end relief and crowning by minimizing the vibration exciting force of helical gears. We estimate the vibration exciting force by the meshing analysis of gears. Formulated constraints of this problem consist of contact ratio and strengths of gear teeth such as tooth bending strength, surface durability, and scoring. ADS(Automated Design Synthesis) is used as an optimization tool. We also investigate the relation between the aspect ratio and the optimum values of tooth modification. The proposed method can calculate the optimum amount of tooth modification automatically and is expected to be practically useful to resolve the problem of vibration of helical gears.

  • PDF

헬리컬 치차의 진동최소화를 위한 치면 수정량의 결정 (Determination of the Tooth Modification Amounts for Minimizing the Vibration of Helical Gear)

  • 정태형;명재형;김기태
    • 한국정밀공학회지
    • /
    • 제17권11호
    • /
    • pp.199-205
    • /
    • 2000
  • The vibration and noise of gears is due to the vibration exciting force caused by the tooth stiffness which changes periodically as the mesh of teeth proceeds and by the transmission error, that is, the rotation delay between driving gear and driven gear caused by manufacturing error and alignment error in assembly and so on. The purpose of this study is to develop how to calculate simultaneously the optimum amounts of tooth profile modification, end relief and crowning by minimizing the vibration exciting force of helical gears. We estimate the vibration exciting force by the mesh analysis of gears. The constraints of this problem consist of contact ratio and strengths of gear teeth such as tooth fillet stress, surface durability and scoring. ADS(Automated Design Synthesis) is used as an optimization tool. And, since the aspect ratio is an important parameter of tooth modification, we investigate the relation between it and the optimum values of tooth modification. The proposed method can calculate the optimum amount of tooth modification automatically and is to be utilized to resolve the problem of vibration of helical gears.

  • PDF

만성 목-어깨 통증이 있는 여성 성인에게 시청각 매체를 활용한 탄력밴드 저항운동이 통증, 고유수용성 감각과 운동기능에 미치는 영향 (Effects of Elastic Band-Resistive Exercise using Audio-visual Medium on Pain, Proprioceptive Sense, and Motor Function in Adult Females with Chronic Neck and Shoulder Pain)

  • 이남기;이정우
    • 대한물리치료과학회지
    • /
    • 제31권1호
    • /
    • pp.33-45
    • /
    • 2024
  • Background: This study aimed to investigate the effect of elastic band-resistive exercise using audio-visual medium on pain, proprioception, and motor function in adults with chronic neck and shoulder pain. Design: One group pretest-posttest follow-up experimental design. Method: Twenty adult women with neck and shoulder pain voluntarily participated in this study. Elastic band-resistive exercise using audio-visual medium including cervical flexion and extension, shoulder external rotation, and scapular retraction-protraction motions was conducted 5 times a week for 3 weeks. The Numerical Rating Scale, pressure threshold tool, CROM goniometer, and Image J software were used to assess subjective pain level, tenderness threshold (pain), joint position sense error (proprioception), joint range of motion, and postural alignment (motor function), respectively. Result:: The pain intensity and threshold and joint position sense error showed significant decreases after the intervention, whereas the joint range of motion angle revealed significant increases. The postural alignment including forward head posture and rounded shoulder revealed significant improvements after the intervention. Conclusions: Therefore, we suggest that elastic band-resistive exercise through audio-visual medium would be helpful in preventing and managing pain and physical dysfunction in individuals with chronic neck and shoulder pain, and then it would support the development of health management-related online education content.

분리된 마스트에 설치되는 선체고정 위상 배열 레이더의 기계적 정렬 (Mechanical Alignment of Hull Mounted Phased Array Radar on the Separated Mast)

  • 서형필;김대한;김준우;이경진;조규룡
    • 한국산학기술학회논문지
    • /
    • 제20권9호
    • /
    • pp.465-473
    • /
    • 2019
  • 본 논문은 4면 선체 고정형 위상 배열 레이더를 부착하기 위한 2개의 분리된 마스트를 해군 함정에 정확하게 탑재하기 위한 기계적 정렬 방법과 정렬을 위한 3D 스캐너를 활용한 계측 방법에 대해 연구하였다. 선체 고정 위상 배열레이더는 초고주파를 사용하므로 짧은 파장으로 인해 작은 위치오차에도 이로 인한 소자의 위상차이가 발생할 수 있고 배열 안테나가 선체 고정식이므로 4개의 배열 면에 대해 회전형 레이더 보다 높은 정도 관리(accuracy control)가 필수적이다. 육상 공장에서 제작된 2개의 레이더용 마스트에 대한 편평도 확인 방법, 마스트들을 함정에 탑재하기 위해 정렬을 하는 방법과 4개의 array 부착용 Pad 가공 면에 대해 정렬하는 방법을 도출하였다. 이에 대한 도구로 3D 레이저 스캐너에 의한 측량과 측량 결과를 3D CAD와 비교하기 위한 소프트웨어 활용의 방법이 사용된다. 이 논문은 한국 해군함정에서 분리된 마스트에 4면 선체 고정 위상 배열 레이더를 설치하고 기계적 정렬 방법을 도출한 최초의 사례로서 의미가 있다.

레이저 간섭계를 이용한 이동형 미세 변위 측정에 관한 연구 (A Study on the Portable Micro Displacement Measurement Using Laser Interferometer)

  • 최경현;양형찬
    • 동력기계공학회지
    • /
    • 제10권2호
    • /
    • pp.99-103
    • /
    • 2006
  • The laser interferometer has been used for measurement of the micro displacement error. Although the laser interferometer is widely accepted as a tool for measurement of motion accuracy, the set-up procedure is time-consuming because of the strict requirement on alignment between a laser head and optic units. This paper addresses the development of a laser interferometer to measure the micro displacement for a micro machine. The portable laser interferometer which integrates a laser probe and optics, is developed for the convenient measurement. For the experiment, moving mirror set up on the micro stage. The velocity decoding board is also added to calculate doppler shift frequency directly. The output signal is obtained and analyzed by LabView. Finally experiments are found out the relation between micro displacement and output signal.

  • PDF

다이아몬드 터닝머신에서 다중점 B 축 제어 가공법을 통한 표면거칠기 향상 (Improvement in Surface Roughness by Multi Point B Axis Control Method in Diamond Turning Machine)

  • 김영복;황연;안중환;김정호;김혜정;김동식
    • 한국정밀공학회지
    • /
    • 제32권11호
    • /
    • pp.983-988
    • /
    • 2015
  • This paper details a new ultra-precise turning method for increasing surface quality, "Multi Point B Axis Control Method." Machined surface error is minimized by the compensation machining process, but the process leaves residual chip marks and surface roughness. This phenomenon is unavoidable in the diamond turning process using existing machining methods. However, Multi Point B axis control uses a small angle (< $1^{\circ}$) for the unused diamond edge for generation of ultra-fine surfaces; no machining chipping occurs. It is achieved by compensated surface profiling via alignment of the tool radial center on the center of the B axis rotation table. Experimental results show that a diamond turned surface using the Multi Point B axis control method achieved P-V $0.1{\mu}m$ and Ra 1.1nm and these ultra-fine surface qualities are reproducible.

사장교 케이블 최적 장력 보정에 관한 연구 (A Study for Finding Optimized Cable Forces of Cable Stayed Bridge)

  • 박대용
    • 복합신소재구조학회 논문집
    • /
    • 제3권1호
    • /
    • pp.16-20
    • /
    • 2012
  • 사장교의 시공에 있어서 보강형과 주탑의 형상 및 케이블 장력은 형상관리시 주요한 관리 항목이다. 특히 보강형의 형상은 Keg Segment의 원활한 폐합뿐만 아니라 계획된 종단 및 횡단 선형을 구현하기 위해 필수적으로 관리되어야 한다. 사장교에서 단계별 시공을 진행함에 따라 보강형 레벨과 케이블 장력 오차는 피할 수 없으며, 이러한 오차는 크게 재료 물성치와 모델링상의 오차, 제작 및 시공에 의해 발생하는 오차 등으로 나눌 수 있다. 이러한 오차로 인해 케이블의 장력과 구조물의 처짐 또는 변위가 이론적인 해석값과 다르게 나타나며, 이에 대한 보정은 케이블의 길이 조정으로 수행하게 된다. 본 연구에서는 제2돌산대교에서 사용된 오차를 보정하는 새로운 최적화 기법을 소개하고자 한다.

공작기계용 접촉식 측정 프로브의 프로빙 오차 보상에 관한 연구 (Touch-Trigger Probe Error Compensation in a Machining Center)

  • 이찬호;이응석
    • 대한기계학회논문집A
    • /
    • 제35권6호
    • /
    • pp.661-667
    • /
    • 2011
  • 접촉식 측정 프로브는 3 차원 좌표 측정기 및 CNC 공작기계 등에서 제품 검사에 많이 활용되고 있고, 최근 품질 향상을 위한 가공 및 검사장비의 고정도화에 따라 측정의 정확도도 또한 매우 중요시 되고 있다. 이에 따라 스트레인 게이지 등을 이용한 고정도의 측정 프로브가 사용되고 있기는 하지만, 본 연구에서는 경제적인 측면을 고려하여 산업현장에서 공작기계에 많이 활용되는 일반 접촉식 측정 프로브의 메커니즘을 이해하고, 측정 시 발생할 수 있는 프로빙 오차에 대한 분석 및 보정을 통하여 그 활용성을 높이고자 하였다. 이를 위하여 스타일러스 반경 및 중심 정렬오차가 규명되었고, 3 차원 공간상의 측정 좌표에서 프로빙 오차에 대한 해석이 이루어졌다. 이러한 오차들을 보정하기 위한 알고리즘이 개발되었으며, 실제 CNC 공작기계 상에서 기준구 측정을 통한 검증이 이루어졌다.

척추방사선수술시 실시간 추적검사에 의한 병소목표점 위치변이 평가 (Evaluation of Real-time Target Positioning Accuracy in Spinal Radiosurgery)

  • 이동준
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.290-294
    • /
    • 2013
  • 방사선수술은 고 용량의 방사선을 병소의 목표점에 정확하게 주위의 정상조직을 보호하면서 한 번에 혹은 수 차에 거쳐 전달하는 방법이므로 병소 국재에 대한 오차의 크기는 방사선수술에 직접적인 영향을 끼치게 된다. 본 연구에서는 영상유도 국재 장비인 ExacTrac (BrainLab, Germany)을 이용한 척추방사선수술에서 병소 목표점 국재의 오차를 평가하였다. 국재 오차를 최소화 하기위하여 방사선수술 전 '환자위치 확인장치(PPVT)'를 고안하여 부가적으로 사용하였다. 실시간 목표점오차 평가를 위하여 흉추에 전이된 종양에 대한 방사선수술 8례를 대상으로 평가하였다. 그 결과 isocenter 목표점 오차는 횡단면(lateral) 축 방향, 종단면(longitudinal) 축 방향, 수직면(vertical) 축 방향으로 각각 $0.07{\pm}0.17$ mm, $0.11{\pm}0.18$ mm, $0.13{\pm}0.26$ mm이었으며 평균 공간오차는 $0.20{\pm}0.37$ mm이었다. 병소 isocenter의 회전오차(body rotation)는 종단면(longitudinal) 축 방향 $0.14{\pm}0.07^{\circ}$, 횡단면(lateral) 축 방향 $0.11{\pm}0.07^{\circ}$, 환자테이블 각 이동 $0.03{\pm}0.04^{\circ}$로 평균오차는 $0.20{\pm}0.11^{\circ}$이었다. 본 연구결과 영상유도 국재방법을 이용한 척추방사선수술에서의 병소목표점 국재 평균오차는 임상적으로 허용할 수 있는 오차범위 이내 임을 확인하였다.

Reliability and validity of rasterstereography measurement for spinal alignment in healthy subjects

  • Yi, Yoon-Sil;Yoo, Seul-Ki;Lee, Da-Gam;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권1호
    • /
    • pp.22-28
    • /
    • 2016
  • Objective: The Back Mapper is one type of Rasterstereography and it can be used in the clinic without radiation exposure. The purpose of our study was to prove the reliability and validity of the Back Mapper and to compare it with the Spinal Mouse, which is an assessment tool for spinal curvatures using a wheeled mouse, and the Cobb angle by X-ray. Design: Cross-sectional study. Methods: Twenty healthy adults participated in the test to investigate for the inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with assessment devices for scoliosis such as the Back Mapper, Spinal Mouse and Cobb's angle. Data was analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement for reliability and correlation analysis for validity. Results: Intra-rater reliability of the Back Mapper was good (Cronbach's ${\alpha}$=0.821-0.984, ICC=0.696-0.969) except for assessing the lordotic angle. Inter-rater reliability was good (Cronbach's ${\alpha}$=0.870-0.958, ICC=0.770-0.919) in assessment for trunk imbalance, rotation of scapulae, thoracic angle, lumbar angle, and kyphotic angle. The kyphotic angle in the Spinal Mouse had a significant correlation icompared with the Back Mapper (r=0.510, p<0.05), and the Cobb's angle from an X-ray had a significant correlation with trunk inclination (r=0.532, p<0.05). Conclusions: These findings provide good intra-reliability of the Back Mapper in healthy subjects, but the Back Mapper requires more experienced practice to have good inter-reliability. Also, the variables of the Back Mapper does not seem as appropriate compared with the Cobb angle by X-ray.