• Title/Summary/Keyword: Tongue position

Search Result 119, Processing Time 0.019 seconds

Volumetric measurement of the tongue and oral cavity with cone-beam computed tomography: A systematic review

  • Kannitha Alina, Aflah;Winny, Yohana;Fahmi, Oscandar
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.333-342
    • /
    • 2022
  • Purpose: The goal of this systematic review was to compare the use of cone-beam computed tomography (CBCT) with that of computed tomography (CT) for volumetric evaluations of the tongue and oral cavity. Materials and Methods: A search for articles was conducted in accordance with the Preferred Reporting Items for Systematic Review and Meta-analyses guidelines. The PubMed, Scopus, ScienceDirect, and SAGE Journals databases were searched for articles published between 2011 and 2021. Articles were screened and assessed for eligibility. Screening involved checking for duplication, reading the title and abstract, and reading the full text. Results: The initial search retrieved 25,780 articles. Application of the eligibility criteria yielded 16 articles for qualitative analysis. Multiple uses of CBCT were identified. In several studies, researchers assessed the volumetric correlation between tongue and oral cavity volumes, as well as other parameters. Post-treatment volumetric evaluations of the oral cavity were also reported, and the reliability of CBCT was assessed. The use of CT resembled that of CBCT. Conclusion: CBCT has been used in the evaluation of tongue and oral cavity volumes to assess correlations between those volumes and with the upper airway. It has also been used for volumetric evaluation after surgical and nonsurgical procedures and to assess the relationships between tongue volume, tooth position, occlusion, and body mass index. Participants with obstructive sleep apnea and malocclusion have been evaluated, and the reliability of CBCT has been assessed. In the included studies, CT was utilized for similar purposes as CBCT, but its reliability was not assessed.

LINGUAL FRENECTOMY UNDER ORAL SEDATION (경구 진정요법하에 시행한 설소대 절제술)

  • Jang, Yong-Gul;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.4
    • /
    • pp.568-574
    • /
    • 2009
  • Tongue-tie is a congenital anomaly characterized by an abnormally short lingual frenum, which may restrict tongue tip mobility, In the neonate and infant, tongue-tie was said to cause difficult breast-feeding, In the older infant, toddler and young child, poor speech has been frequently listed because movement of tongue tip is limit ed. Also as a abnormal tongue position, various orthodontic problems, later mechanical and social manifestations could be developed. Treatment options such as observation, speech therapy, frenotomy and frenectomy have been suggested. The optimal timing for the surgery has not been determined, but early intervention may be appropriate for the children with significant tongue-tie who has the significant potential to speech difficulties and later social and mechanical problems. Sedation is an effective method for incapable of cooperative and the handicapped children, necessary to early intervention. We report three cases, using oral sedation for the frenectomy in young children with severe tongue-tie. After treatments, we could find out sufficient tongue movement and improved speech ability.

  • PDF

Size and Retention of Tongue Bulb for Tongue Retaining Device (혀 유지구의 크기와 유지력 평가)

  • Park, Nam-Seon;Lee, Ki-Ho;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.283-292
    • /
    • 2007
  • In several treatment modalities for snoring and obstructive sleep apnea (OSA), oral appliances mainly including mandibular advancement appliance (MAA) and tongue retaining device (TRD) are recognized as a non-invasive, reversible alternative with favorable results. Tongue bulb is a major component of TRD which prevents the tongue from approaching the posterior wall of the pharynx and can be combined with MAA. Determination of tongue bulb size for the patient is important for therapeutic effect, but frequently needs time-consuming work. For effective fabrication and standardization of tongue bulbs, this study aimed to categorize tongue bulb size for healthy young men and to examine its relation with maximum retention force and with physical parameters including tongue-related variables. 36 non-snoring, asymptomatic young men with normal occlusion were voluntarily participated in this study (mean age: $24.47{\pm}2.58$ years). Experimental procedures consisted of prefabrication of tongue bulb set (20 types with a width of 27-36mm and thickness of 8 and 10 mm), determination of tongue bulb size and the maximum retention force for each subject, and measurement of physical parameters including body mass index (BMI), neck circumference and width, thickness and length of tongue. This study showed that there was significant difference of retention force among the bulb size-related groups both in upright and supine position (p<0.05) and that retention force increased with bulb size. Correlation of tongue bulb size with physical parameters was not clearly verified and there was no significant difference in retention force between upright and supine positions. Based on our results, it can be suggested that retention force relates with tongue bulb size, ultimately with tongue volume. A further study needs to be performed in the patients with snoring and OSA.

Preliminary study of Korean Electro-palatography (EPG) for Articulation Treatment of Persons with Communication Disorders (의사소통장애인의 조음치료를 위한 한국형 전자구개도의 구현)

  • Woo, Seong Tak;Park, Young Bin;Oh, Da Hee;Ha, Ji-wan
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.299-304
    • /
    • 2019
  • Recently, the development of rehabilitation medical technology has resulted in an increased interest in speech therapy equipment. In particular, research on articulation therapy for communication disorders is being actively conducted. Existing methods for the diagnosis and treatment of speech disorders have many limitations, such as traditional tactile perception tests and methods based on empirical judgment of speech therapists. Moreover, the position and tension of the tongue are key factors of speech disorders with regards to articulation. This is a very important factor in the distinction of Korean characters such as lax, fortis, and aspirated consonants. In this study, we proposed a Korean electropalatography (EPG) system to easily measure and monitor the position and tension of the tongue in articulation treatment and diagnosis. In the proposed EPG system, a sensor was fabricated using an AgCl electrode and biocompatible silicon. Furthermore, the measured signal was analyzed by implementing the bio-signal processing module and monitoring program. In particular, the bio-signal was measured by inserting it into the palatal from an experimental control group. As a result, it was confirmed that it could be applied to clinical treatment in speech therapy.

Changes of the Pharyngeal Space by Various Oral Appliances for Snoring (수종의 코골이장치 장착에 따른 인두공간의 변화)

  • Jo, Chul-Bae;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.3
    • /
    • pp.247-256
    • /
    • 2009
  • The purpose of this study was to investigate the changes of the pharyngeal space when the following appliances were inserted: the mandibular advancement appliance (MAA), tongue retaining appliance (TRA), and mandibular advancement-tongue retaining appliance (MATRA). Nine male dental students exhibiting Class I occlusion, normal body mass index (BMI), and no signs and symptoms of snoring were selected for this study. The three kinds of snoring appliances (MAA, TRA and MATRA) were fabricated for each subject. The mandibular advancement of the MAA and MATRA was set at a distance of 5 mm, and the TRA and MATRA were made to hold the tongue in front of the maxillary incisors by 10 to 20 mm. Lateral cephalometric radiographs of the following four states - with no appliance, MAA, TRA, and MATRA - were taken to examine any anatomical changes resulting from the application of the appliances. All four radiographs were traced and analyzed for twenty selected variables related to the pharyngeal space, cranio-cervical posture, and position of the soft palate and hyoid bone. According to the results of this study, there were significant increases in both the upper and lower oropharyngeal spaces when the mandible and tongue were protruded simultaneously, although there was a significant increase only in upper oropharyngeal space when the mandible or tongue was advanced separately. In conclusion, it is suggested that the MATRA may result in more positive effect on the control of snoring and OSA compared to a single use of the MAA or TRA, especially for the patients whose upper airway obstruction occurs in the lower oropharynx.

Complete denture rehabilitation of partially glossectomized patient using palatal augmentation prosthesis: A case report (부분 혀 절제술을 받은 완전 무치악 환자에서 구개증대보철물을 이용한 수복 증례)

  • Hyeon-Kyeong Lee;Na-Hong Kim;Hee-Won Jang;Sun-Young Yim;Keun-Woo Lee;Sung-Yong Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.82-89
    • /
    • 2023
  • The tongue is one of the most common sites of oral cancer. Glossectomy is known as the gold standard for tongue cancer treatment. However, surgical removal can lead to reduced mobility of the tongue and the patients may have difficulty performing normal oral functions like swallowing and pronunciation. Therefore, additional prosthetic consideration to supplement the function of the impaired tongue is needed for oral rehabilitation of such patients. Palatal augmentation prosthesis helps the tongue to reach the palate by lowering the position of the palatal polished surface. The oral functions of the patients with limited tongue mobility can be improved by the prosthesis. In this case, palatal augmented maxillary denture and conventional mandibular denture were fabricated for the completely edentulous patient with reduced tongue mobility after glossectomy due to tongue cancer. As a result, the oral functions of the patient were improved with the prosthesis.

A CEPHALOMETRIC STUDY ON THE POSITION OF THE HYOID BONE IN CLEFT LIP AND PALATE INDIVIDUALS (순구개열자의 설골 위치에 관한 두부방사선 계측학적 연구)

  • Cho, Il Je;Rhee, Byung Tae
    • The korean journal of orthodontics
    • /
    • v.20 no.1
    • /
    • pp.197-207
    • /
    • 1990
  • This comparative study was undertaken to investigate the position of the hyoid bone in unilateral cleft lip and palate individuals. The materials for this study consisted of 35 subjects with surgically repaired unilateral cleft lip and palate (25 males, 10 females) and 40 subjects with normal facial morphology (20 males, 20 females). Cephalometric measurements of unilateral cleft and palate individuals were compared with those of non-cleft individuals. The conclusions of this study were obtained as follows: 1. To the anterior cranial base, the hyoid bone in unilateral cleft lip and palate individuals was located downward as compared with non-cleft individuals. 2. To the mandible, the hyoid bone in unilateral cleft lip and palate individuals was located backward as compared with non-cleft individuals. 3. The distance between the dorsum of the tongue and the inferior border of the hard palate in unilateral cleft lip and palate individuals was longer than that in non-cleft individuals. 4. Unilateral cleft lip and palate individuals showed no significant difference in the distance between the hyoid bone and the dorum of the tongue as compared with non-cleft individuals.

  • PDF

Unsteady Analysis of Impeller-Volute Interaction in Centrifugal Pump

  • Cheah, Kean Wee;Lee, Thong See;Winoto, Sonny H.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.3
    • /
    • pp.349-359
    • /
    • 2011
  • An unsteady numerical analysis has been carried out to study the strong impeller volute interaction of a centrifugal pump with six backward swept blades shrouded impeller. The numerical analysis is done by solving the three-dimensional Reynolds Averaged Navier-Stokes codes with standard k-${\varepsilon}$ two-equations turbulence model and wall regions are modeled with a scalable log-law wall function. The flow within the impeller passage is very smooth and following the curvature of the blade in stream-wise direction. However, the analysis shows that there is a recirculation zone near the leading edge even at design point. When the flow is discharged into volute casing circumferentially from the impeller outlet, the high velocity flow is severely distorted and formed a spiraling vortex flow within the volute casing. A spatial and temporal wake flow core development is captured dynamically and shows how the wake core diffuses. Near volute tongue region, the impeller/volute tongue strong interaction is observed based on the periodically fluctuating pressure at outlet. The results of existing analysis also proved that the pressure fluctuation periodically is due to the position of impeller blade relative to tongue.

An Electropalatographic Study of English 1, r and the Korean Liquid Sound ㄹ

  • Ahn, Soo-Woong
    • Speech Sciences
    • /
    • v.8 no.2
    • /
    • pp.93-106
    • /
    • 2001
  • The pronunciation of English l and r was a consistent problem in learning English in Korea as well as Japan. This problem occurs from the fact that in Korea and Japan there is only one liquid sound. Substituting the Korean liquid for English l and r was a common error. The pronunciation of the dark l causes a further problem in pronouncing the English l sound. To see the relationship between the English l, r, and the Korean liquid sound, an electropalatographic (EPG) experiment was done. The findings were (1) there were no tongue contacts either on the alveolar ridge or on the palate during the articulation of the dark l. (2) The Korean liquid sound was different in the tongue contact points either from English l or r. The English clear l consistently touched the alveolar ridge in the forty tokens, but the Korean liquid sound in the intervocalic and word-final position touched mainly the alveopalatal area. The English r touched exclusively the velum area. The Korean intervocalic /l/ was similar to English flap in EPG and spectrographic data. There was evidence that the word-final Korean /l/ is a lateral.

  • PDF

Morphological Study on the Dorsal Lingual Papillae of Sorex caecutiens Laxmann (뒤쥐(Sorex caecutiens) 혀유두의 형태학적 연구)

  • Park, Ji-Won;Lee, Jung-Hun
    • Applied Microscopy
    • /
    • v.39 no.2
    • /
    • pp.101-106
    • /
    • 2009
  • The dorsal lingual papillae of Sorex caecutiens were studied morphologically using scanning electron microscopy. Three types of lingual papillae were found: filiform papillae, fungiform papillae and circumvallate papillae. Filiform papillae were observed in most part of the tongue except on the lateral surface. There were basically three types of filiform papillae distinguished mainly by their morphological shape and structure. Numerous fungiform papillae were spread throughout the whole tongue, especially concentrated in lateral sides. The size varied according to the position of fungiform papillae, becoming larger as it reached to the rear. Strict pair-wise distribution was not observable, but fungiform papillae were mostly located in orderly manner. There were two large circumvallate papillae at the posterior region of the tongue. There were two thick pads around the center part where several bodies were gathered together. Overall research provided similar results with other close species such as common shrew (S. araneus). The circumvallate papillae of S. caecutiens were different from other Sorex species. They were circular, as in bats and other Sorex species, and had two distinguishable pads while others had only one.