Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

  • Oliveira, Matheus L.;Tosoni, Guilherme M.;Lindsey, David H.;Mendoza, Kristopher;Tetradis, Sotirios;Mallya, Sanjay M.
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.279-285
    • /
    • 2014
  • Purpose: To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods: Tubes containing solutions with different concentrations of $K_2HPO_4$ were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the $K_2HPO_4$ solutions were measured. The relationship between CT number and $K_2HPO_4$ concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results: The relationship between $K_2HPO_4$ concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion: There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.

Relationship between trabecular strength and three-dimensional architecture in the pig mandible using microcomputed tomography (돼지 하악골의 micro-CT영상에서 추출한 3차원 골미세구조와 골강도 사이의 상관관계)

  • Huh Kyung-Hoe;Park Moo-Soon;Yi Won-Jin;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.35 no.3
    • /
    • pp.167-173
    • /
    • 2005
  • Purpose : To investigate the relationship between three-dimensional (3D) bone imaging parameters and trabecular strength in the mandible. Materials and Methods : Bone specimens were obtained from the mandibles of five male pigs weighing around 110 kg each. Of those, 43 samples were selected for 3D analysis and measured by micro-computed tomography. The five morphometric parameters were trabecular thickness (Tb.Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI) and degree of anisotropy (DA). Through destructive mechanical testing, strength parameters were obtained. Results : BV/TV, SMI, BS/BV, and Tb.Th showed significant correlations with strength parameters. DA did not show any correlation with the other parameters. In multiple linear regression analysis, BV/TV alone explained $43\%$ of the variance in Young's modulus. By stepwise inclusion of SMI, the variance in the Young's modulus was better explained up to $52\%$. Conclusions : Predicting trabecular strength in the mandible through architectural analysis would be possible. Further study is needed to establish the tendency and variety of trabecular architecture and strength according to the locations within the mandible.

  • PDF

Computed Tomography Spending and Utilization for Inpatients with Cerebral Infarction in South Korea

  • Choi, Su Kyung;Han, Kyu-Tae;Kim, Sun Jung;Sohn, Tae Yong;Jeon, Byungyool;Park, Eun-Cheol
    • Health Policy and Management
    • /
    • v.27 no.4
    • /
    • pp.359-365
    • /
    • 2017
  • Background: Computed tomography (CT) is one of the most efficient diagnostic methods for stroke patients. The number of CT scanners in South Korea, however, is higher than in other countries, and may cause the overuse of this tool in healthcare. We aim to study the relationship between using CT and various patient and hospital characteristics among patients with cerebral infarction. Methods: We analyzed nationwide health insurance claims data for patients due to cerebral infarction during the second half of 2013 for up to 3 months. We performed multilevel analysis, including both inpatient and hospital-level variables, to determine how factors affect CT spending and utilization. Results: The data used in our study consisted of 17,046 hospitalizations at 583 hospitals. Inpatients who visited more than one hospital had higher CT utilization numbers and cost (number: ${\geq}3$: ${\beta}$ hospitals, 2.27; p < 0.05; 2 hospitals: ${\beta}$, 0.70; p < 0.05; cost: ${\geq}3$ hospitals: ${\beta}$, 251,108; p < 0.05; 2 hospitals: ${\beta}$, 77,299; p < 0.05). People who visited a general hospital had higher numbers and cost of CT utilization than people who visited a smaller hospital. Conclusion: Increased sharing of records and improved continuity of care between hospitals are needed to help curb the overuse of CT.

The diagnosis of coronoid impingement using computed tomography

  • Baik Jee-Seon;Huh Kyung-Hoe;Park Kwan-Soo;Park Moo-Soon;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.35 no.4
    • /
    • pp.231-234
    • /
    • 2005
  • Coronoid impingement can cause limitation of mouth opening. In many cases, it appears to be related to the coronoid hyperplasia. We present a case of mouth opening limitation caused by coronoid impingement on the posterior surface of the zygomatic bone without coronoid hyperplasia. The bony changes in coronoid and zygoma including surface irregularity and discontinuity of the cortex and sclerotic change of inner medullary space were noted on computed tomography (CT) scans in different level of axial planes. Through another CT scans in open mouth position could demonstrate that those bony changes were caused by the contact of both surfaces against each other. In case coronoid impingement is suspected of the many possible causes, the open mouth CT scans will be needed to reveal the direct impingement of coronoid on zygoma even without coronoid hyperplasia.

  • PDF

Accuracy Analysis of Magnetic Resonance Angiography and Computed Tomography Angiography Using a Flow Experimental Model

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Park, Cheol-Soo;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.40-46
    • /
    • 2015
  • This study investigated the accuracy of magnetic resonance angiography (MRA) and computed tomography angiography (CTA) in terms of reflecting the actual vascular length. Three-dimensional time of flight (3D TOF) MRA, 3D contrast-enhanced (CE) MRA, volume-rendering after CTA and maximum intensity projection were investigated using a flow model phantom with a diameter of 2.11 mm and area of $0.26cm^2$. 1.5 and 3.0 Tesla devices were used for 3D TOF MRA and 3D CE MRA. CTA was investigated using 16 and 64 channel CT scanners, and the images were transmitted and reconstructed by volume-rendering and maximum intensity projection, followed by conduit length measurement as described above. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s using the 3.0 Tesla apparatus, and $2.57{\pm}0.07mm$ with a velocity of 71.5 cm/s using the 1.5 Tesla apparatus; both images were magnified from the actual measurement of 2.11 mm. The measurement with the 16 channel CT scanner was smaller ($3.83{\pm}0.37mm$) than the reconstructed image on maximum intensity projection. The images from CTA from examination apparatus and reconstruction technique were all larger than the actual measurement.

18FDG Synthesis and Supply: a Journey from Existing Centralized to Future Decentralized Models

  • uz Zaman, Maseeh;Fatima, Nosheen;Sajjad, Zafar;Zaman, Unaiza;Tahseen, Rabia;Zaman, Areeba
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10057-10059
    • /
    • 2015
  • Positron emission tomography (PET) as the functional component of current hybrid imaging (like PET/CT or PET/MRI) seems to dominate the horizon of medical imaging in coming decades. $^{18}$Flourodeoxyglucose ($^{18}FDG$) is the most commonly used probe in oncology and also in cardiology and neurology around the globe. However, the major capital cost and exorbitant running expenditure of low to medium energy cyclotrons (about 20 MeV) and radiochemistry units are the seminal reasons of low number of cyclotrons but mushroom growth pattern of PET scanners. This fact and longer half-life of $^{18}F$ (110 minutes) have paved the path of a centralized model in which $^{18}FDG$ is produced by commercial PET radiopharmacies and the finished product (multi-dose vial with tungsten shielding) is dispensed to customers having only PET scanners. This indeed reduced the cost but has limitations of dependence upon timely arrival of daily shipments as delay caused by any reason results in cancellation or rescheduling of the PET procedures. In recent years, industry and academia have taken a step forward by producing low energy, table top cyclotrons with compact and automated radiochemistry units (Lab-on-Chip). This decentralized strategy enables the users to produce on-demand doses of PET probe themselves at reasonably low cost using an automated and user-friendly technology. This technological development would indeed provide a real impetus to the availability of complete set up of PET based molecular imaging at an affordable cost to the developing countries.

Assessment of Coronary Stenosis Using Coronary CT Angiography in Patients with High Calcium Scores: Current Limitations and Future Perspectives (높은 칼슘 점수를 가진 환자에서 관상동맥 CT 조영술을 이용한 협착 평가의 한계와 전망)

  • Doo Kyoung Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.270-296
    • /
    • 2024
  • Coronary CT angiography (CCTA) is recognized for its role as a gatekeeper for invasive coronary angiography in patients suspected of coronary artery disease because it can detect significant coronary stenosis with high accuracy. However, heavy plaque in the coronary artery makes it difficult to visualize the lumen, which can lead to errors in the interpretation of the CCTA results. This is primarily due to the limited spatial resolution of CT scanners, resulting in blooming artifacts caused by calcium. However, coronary stenosis with high calcium scores often requires evaluation using CCTA. Technological methods to overcome these limitations include the introduction of high-resolution CT scanners, the development of reconstruction techniques, and the subtraction technique. Methods to improve reading ability, such as the setting of appropriate window width and height, and evaluation of the position of calcified plaque and residual visibility of the lumen in cross-sectional images, are also recommended.

APPLICATION OF A DUAL-ENERGY MONOCHROMATIC XRAY CT ALGORITHM TO POLYCHROMATIC X-RAY CT: A FEASIBILITY STUDY

  • Chang, S.;Lee, H.K.;Cho, G.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.1
    • /
    • pp.61-70
    • /
    • 2012
  • In this study, a simple post-reconstruction dual-energy computed tomography (CT) method is proposed. A dual-energy CT algorithm for monochromatic x-rays was adopted and applied to the dual-energy CT of polychromatic x-rays by assigning a representative mono-energy. The accuracy of algorithm implementation was tested with mathematical phantoms. To test the sensitivity of this algorithm to the inaccuracy of representative energy value in energy values, a simulation study was performed with mathematical phantom. To represent a polychromatic x-ray energy spectrum with a single-energy, mean energy and equivalent energy were used, and the results were compared. The feasibility of the proposed method was experimentally tested with two different micro-CTs and a test phantom made of polymethyl methacrylate (PMMA), water, and graphite. The dual-energy calculations were carried out with CT images of all possible energy pairs among 40, 50, 60, 70, and 80 kVp. The effective atomic number and the electron density values obtained from the proposed method were compared with theoretical values. The results showed that, except the errors in the effective atomic number of graphite, most of the errors were less than 10 % for both CT scanners, and for the combination of 60 kVp and 70 kVp, errors less than 6.0 % could be achieved with a Polaris 90 CT. The proposed method shows simplicity of calibration, demonstrating its practicality and feasibility for use with a general polychromatic CT.

Distribution of the intraosseous branch of the posterior superior alveolar artery relative to the posterior maxillary teeth

  • Carsen R. McDaniel;Thomas M. Johnson;Brian W. Stancoven;Adam R. Lincicum
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.121-127
    • /
    • 2024
  • Purpose: Preoperative identification of the intraosseous posterior superior alveolar artery (PSAA) is critical when planning sinus surgery. This study was conducted to determine the distance between the cementoenamel junction and the PSAA, as well as to identify factors influencing the detection of the PSAA on cone-beam computed tomography (CBCT). Materials and Methods: In total, 254 CBCT scans of maxillary sinuses, acquired with 2 different scanners, were examined to identify the PSAA. The distance from the cementoenamel junction (CEJ) to the PSAA was recorded at each maxillary posterior tooth position. Binomial logistic regression and multiple linear regression were employed to evaluate the effects of scanner type, CBCT parameters, sex, and age on PSAA detection and CEJ-PSAA distance, respectively. P-values less than 0.05 were considered to indicate statistical significance. Results: The mean CEJ-PSAA distances at the second molar, first molar, second premolar, and first premolar positions were 17.0±4.0 mm, 21.8±4.1 mm, 19.5±4.7 mm, and 19.9±4.9 mm for scanner 1, respectively, and 17.3±3.5 mm, 16.9±4.3 mm, 18.5±4.1 mm, and 18.4±4.3 mm for scanner 2. No independent variable significantly influenced PSAA detection. However, tooth position (b=-0.67, P<0.05) and scanner type (b=-1.3, P<0.05) were significant predictors of CEJ-PSAA distance. Conclusion: CBCT-based estimates of CEJ-PSAA distance were comparable to those obtained in previous studies involving cadavers, CT, and CBCT. The type of CBCT scanner may slightly influence this measurement. No independent variable significantly impacted PSAA detection.

Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations

  • Shokri, Abbas;Eskandarloo, Amir;Norouzi, Marouf;Poorolajal, Jalal;Majidi, Gelareh;Aliyaly, Alireza
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.11-19
    • /
    • 2018
  • Purpose: This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. Materials and Methods: The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact(control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high- and low-resolution modes, and were evaluated by 2 observers. The chi-square test was used to assess the nominal variables. Results: In strip perforations, the accuracies of low- and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low- and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D. Conclusion: The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.