• Title/Summary/Keyword: To-Tc method

Search Result 1,083, Processing Time 0.026 seconds

Usefulness of $^{99m}Tc$-MDP Bone Scintigraphy for Assessing Vascular Ingrowth on Hydroxyapatite Ocular Implant ($^{99m}Tc$-MDP 골신티그라피를 이용한 Hydroxyapatite 안구 보충물의 혈관 신생 평가 및 임상적 유용성)

  • Kang, Bong-Joo;Sohn, Hyung-Sun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.484-492
    • /
    • 1999
  • Purpose: This study was to evaluate the clinical usefulness of $^{99m}Tc$-MDP bone scintigraphy for assessing vascular ingrowth into the ocular implants after enucleation or evisceration. Materials and Methods: Twenty-four patients (M:F=7:17, mean age: 36 years), who buried a coralline hydroxyapatite after uncomplicated enucleation or evisceration surgery were studied. Dynamic and static scintigraphy on the orbit fossa were obtained after injection of 740 MBq $^{99m}Tc$-MDP to evaluate the status of vascularization. The study was performed from the 3 to 33 weeks after surgery. According to the visual analysis, activity greater than nasal bridge was graded as 4, equal to the nasal bridge as 3, less than nasal bridge but greater than normal orbit as 2, greater than normal orbit but less than grade 2 as 1. Uptake ratio was also calculated by measuring the implants activity (H) and contralateral orbit activity (N). Grading score and uptake ratio were compared with clinical outcome of vascularization. Additionally, we also analyzed the vascularization status as time lapse between primary surgery and scintigraphic study and surgical methods. Results: Twenty-one patients who had bone scintigraphy at 11 weeks after surgery showed increased uptake above grade 2 and greater H/N ratio than 1.16. Of these, 19 patients who had drilling surgery for permanent peg application showed adequate bleeding during the procedure. The activity grade and uptake ratio were inversely correlated with vascular ingrowth. Higher than grade 2 or greater than 1.56 in H/N ratio seemed to be an indicator for better prognosis. Accomplishment of vascularization was not affected by the surgical way such as enucleation or evisceration. Conclusion: $^{99m}Tc$-MDP bone scintigraphy can be a useful method to evaluate the vascularized status of implants. Adequate time for $^{99m}Tc$-MDP bone scintigraphy may be 11-20 weeks after enucleation or evisceration.

  • PDF

Distribution of Tetracycline-Resistance Genes detected from isolates of cultured fishes in Gyeonggi-do (경기도 내 양식어류에서 분리한 병원성 세균의 Tetracycline 내성 유전자 분포)

  • Cho, Ki-Taek;Hwang, Yun-Jeong;Lee, Sang-Woo;Kim, Kwang-Il;Jeong, Hyun-Do
    • Journal of fish pathology
    • /
    • v.34 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • Tetracycline (TC) is one of the antibiotics used for treatment of bacterial infection in Korea. Inadequate usage and abuse cause the resistance to antibiotics, like Tetracycline, Erythromycin, and Fluoroquinolone. It can also affect severe economic loss in aquaculture field in Korea. We isolated 101 bacterial samples from diseased fish at aquaculture sites in Gyeonggi-do during 2015~2018. Minimum inhibitory concentration (MIC) method has been used to determine distribution and to identify bacterial isolates resistant to antibiotics including Oxytetracycline (OTC), Ampicillin (AMP), Clindamycin (CLI), Enrofloxacin (ENRO), Gentamycin (GEN). TC resistant isolates were confirmed antibiotic resistant genes by conventional PCR. Bacterial isolates were identified as Aeromonas spp. (43.5%), Pseudomonas spp. (4.0%) and Vibrio spp. (5.0%). It was confirmed that multi-resistant isolates (77.2%) were predominant over single-resistant one (22.8%). TC resistant genes like tet(A), tet(D), tet(E), tet(G), tet(M), and tet(S) were detected and tet(A) was the most prevalent. Aeromonas spp. is a dominant strain in bacterial infections in fishes of aquaculture sites, and further investigation on various antibiotic resistance genes will be needed for clear understanding of aquaculture sites in Gyeonggi-do.

Quantitative evaluation of hepatic function for pre- and post-surgery patients using deconvolution technique in Tc-99m DISIDA SCAN (Tc-99m DISIDA SCAN에서 deconvolution 방법을 이용한 외과적 수술 전후의 간의 정량적 평가)

  • Kim, S.C.;Kim, D.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.366-369
    • /
    • 1997
  • In this study, we measured upper right, lower right, upper left region to find the optimal region which represent liver function. We found that the upper right region is optimal because of high accuracy and low standard deviation. For normal subjects all the calculated HEFs were greater than 100% and all those of abnormal ones were less than 80%. Thus HEF can be assumed to discriminate abnormal livers from normal ones. It was found that the patients with surgical operation would survive if both the pre-and the post-operative HEFs are greater than 50%. Therefore HEF method can be a good estimator for surgeon to determine the surgical operation and to evaluate remaining hepatic function after surgery as well as it is reliable and simple.

  • PDF

$^{99m}Tc$-HMPAO-labelled Leucocyte Scintigraphy in the Diagnosis of Infection after Total Knee Replacement Arthroplasty (인공슬관절 전치환술 환자에서 $^{99m}Tc$-HMPAO-백혈구 스캔을 이용한 인공관절 감염의 진단)

  • Park, Dong-Rib;Kim, Jae-Seung;Ryu, Jin-Sook;Moon, Dae-Hyuk;Bin, Seong-Il;Cho, Woo-Shin;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.413-421
    • /
    • 1999
  • Purpose: This study was performed to evaluate the usefulness of $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy Materials and Methods: The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age. 65 years) who had total knee replacement arthroplasty. After injection of $^{99m}Tc$-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection. Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Results: Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positives, one false positive and three true negatives in Group B, and six true negatives and two false positives in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively Conclusion: $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity.

  • PDF

Study on Glomerular Filtration Rate comparison according to renal depth measurement of kidney donors (신 공여자에서 신장 깊이 측정에 따른 사구체여과율의 비교에 관한 고찰)

  • Lee, Han Wool;Park, Min Soo;Kang, Chun Goo;Cho, Seok Won;Kim, Joo Yeon;Kwon, O Jun;Lim, Han Sang;Kim, Jae Sam;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.48-56
    • /
    • 2014
  • Purpose $^{99m}Tc$-DTPA renal scintigraphy serves as a key indicator to measure a kidney donor's Glomerular Filtration Rate (GFR) and determine the possibility of kidney transplant. The Gates method utilized to measure GFR considers 3 variables of renal depth, injection dose, and net kidney counts. In this research, we seek to compare changes in kidney donors' GFR according to renal depth measurement methods of the 3 variables. Materials and Methods We investigated 32 kidney donors who had visited the hospital from October, 2013 to March, 2014 and received abdominal CT and $^{99m}Tc$-DTPA GFR examination. With the cross-section image of the CT and the lateral image from a gamma camera, we measured the renal depth and compared with renal depth calculation equations-Tonnesen, Taylor, and Itoh methods. Renal depth-specific GFR was calculated by using Xeleris Ver. 2.1220 of GE. Then the results were compared with MDRD (Modification of Diet Renal Disease) GFRs based on serum creatinine level. Results The renal depths measured based on the CT and gamma camera images showed high correlation. Tonessen equation gave the lowest GFR value while the value calculated by using the renal depth of CT image was the highest with a 16.62% gap. MDRD GFR showed no statistically significant difference among values calculated through Taylor, Itoh, CT and gamma camera renal depth application (P>0.05), but exhibited a statistically significant change in the value based on Tonnesen equation (P<0.05). Conclusion This research has found that, in GFR evaluation in kidney donors by utilizing $^{99m}Tc$-DTPA, Tonnesen equation-based Gates method underestimated the value than the MDRD GFR. Therefore, if a MDRD GFR value shows a huge difference from the actual examination value, using an image-based renal depth measurement, instead of Tonnesen equation applied to Gates method, is expected to give an accurate GFR value to kidney donors.

  • PDF

Structural and Dielectric Properties of the Doped (Ba,Sr)$TiO_3$ Ceramics (불순물이 첨가된 (Ba,Sr) $TiO_3$ 세라믹의 구조 및 유전특성)

  • 임성수;한명수;정민석;김태훈;이금성;한석룡;이성갑
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.33-36
    • /
    • 1998
  • BST(66/34) and BSCT(60/30/10) ceramics were prepared by mixed oxide method and studied about the microstructural and dielectric properties with $Y_2$O$_3$, Dy$_2$O$_3$, La$_2$O$_3$, MnCO$_3$. The grain size of undoped BST was 20~30 ${\mu}{\textrm}{m}$, but that of BST, doped content of MnCO$_3$ was 0.1 mol%, was decreased with increasing the contents of $Y_2$O$_3$. As the content of $Y_2$O$_3$ was Increased, Tc was shifted to lower temperature and dielectric constant at Tc was decreased. The dielectric constant of doped BSCT(60/30/10) ceramics ( 0.9 mol% $Y_2$O$_3$. and 0.1 mol% MnCO$_3$) was about 8, 000 at Tc( 22$^{\circ}C$ ).

  • PDF

Solvolysis Reaction Kinetics, Rates and Mechanism for Phenyl N-Phenyl Phosphoramidochloridate

  • Choi, Hojune;Yang, Kiyull;Koh, Han Joong;Koo, In Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2465-2470
    • /
    • 2014
  • The rate constants of solvolysis of phenyl N-phenyl phosphoramidochloridate (PhNHPO(Cl)OPh, Target Compound-TC1) have been determined by a conductivity method. The solvolysis rate constants of TC1 are well correlated with the extended Grunwald-Winstein equation, using the $N_T$ solvent nucleophilicity scale and YCl solvent ionizing scale, and sensitivity values of $0.85{\pm}0.14$ and $0.53{\pm}0.04$ for l and m, respectively. These l and m values were similar to those obtained previously for the complex chemical substances dimethyl thiophosphorochloridate; N,N,N',N'-tetramethyldiamidophosphorochloridate; 2-phenyl-2-ketoethyl tosylate; diphenyl thiophosphinyl chloride; and 9-fluorenyl chloroformate. As with the five previously studied solvolyses, an $S_N2$ pathway is proposed for the solvolyses of TC1. For four representative solvents, the rate constants were measured at several temperatures, and activation parameters (${\Delta}H^{\neq}$ and ${\Delta}S^{\neq}$) were estimated. These activation parameters are also in line with the values expected for an $S_N2$ reaction.

Characteristics of Sub-cooled Nitrogen Cryogenic System for Applied High-Tc Superconducting Devices (고온초전도 응용기기용 과냉질소 냉각시스템의 냉각특성)

  • 강형구;김형진;배덕권;안민철;윤용수;장호명;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.38-42
    • /
    • 2004
  • The cryogenic system for 6.6 kV/200 A inductive superconducting fault current limiter (SFCL) was developed at Yonsei university in 2003. The sub-cooled nitrogen cryogenic system could be applied to not only SFCL but also many other applied high-Tc superconducting (HTS) devices like superconducting motor, superconducting generator and superconducting magnetic energy storage (SMES). Generally, the cooling capacity of GM-cryocooler depends on the load temperature. Therefore it is necessary to perform the cooling capacity test at no load condition to calculate the exact cooling power and heat load of cryogenic system. In this research, the cooling capacity test of GM-cryocooler was executed and the heat load of developed cryogenic system was calculated. The long run operation test results of sub-cooled nitrogen cryogenic system were successful in pressure and temperature condition. Moreover, the design and fabrication method of cryogenic system were introduced and the test results were described.

Fabrication and Test of Persistent Current Switch for HTS Magnet System

  • Hyoungku Kang;Kim, Jung-Ho;Jinho Joo;Yoon, Yong-Soo;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.92-96
    • /
    • 2003
  • This paper deals with the characteristics of persistent current switch (rCS) system fer applied HTS magnet system. To apply the high-Tc superconductor in superconducting machine such as motror, generator, MAGLEV, MRI, and NMR, the study on high-Tc superconducting persistent current mode must be performed. In this experiment, the PCS system consists otd superconducting magnet, PCS and magnet power supply. The superconducting magnet was fabricated by connecting four double pancake coils (DPCs) in series. The PCS was inductive double pancake coil type and heated up by the SUS 303L tape heater. The optimal length of PCS was calculated and thermal quench state of PCS was simulated by using finite element method(FEM) and compared with experimental results. The optimal energy to normalize the PCS was calculated and introduced. Finally, the persistent current was observed with respect to various ramping up rate and magnitude of charging current.

International Standards trend on Hydrogen fuel quality (ISO/TC197/WG12의 수소품질 국제표준화 동향)

  • Cho, Sung-Kook;Cho, Chang-Ae;Lee, Taeck-Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.739-743
    • /
    • 2009
  • Japan is leading standards for the hydrogen fuel quality on the PEMFC(Proton Exchange Membrane Fuel Cell) vehicle at ISO/TC197/WG12. However, it has many problems to solve the standard of measurement and the test method. because the standard of measurement which was proposed in Japan is too high to reach the technique for many countries. it might not control standards for the hydrogen fuel quality on the PEMFC vehicle in Korea. So we need to develop the study of standards and the technique of measurement continuously for the International Standards Meeting.

  • PDF