• 제목/요약/키워드: Titanium plate

검색결과 169건 처리시간 0.021초

Modified Anterior Craniofacial Osteotomy Using Partial Nasal Bone Division and Reconstruction in Frontoethmoidal Sinus Meningioma

  • Park, Eon Ju;Kim, Hong Il;Park, Jin Hyung;Yi, Hyung Suk
    • 대한두개안면성형외과학회지
    • /
    • 제18권2호
    • /
    • pp.117-121
    • /
    • 2017
  • Typical transcranial approaches are insufficient for adequate visualization and resection of skull base tumors. Different approaches with multiple modifications have been attempted. Here, we describe a new approach for a lesion that is central and hard to treat by conventional craniotomy and successful reconstruction with calvarial bone graft and titanium mesh plate. A 69-year-old female patient presented with recurrent meningioma. The tumor had invaded the frontal lobe, right supraorbital rim, and ethmoidal bone. We performed a modified anterior craniofacial approach that fully exposed the tumor and invaded bone. In consideration of the patient's age and cosmetic result, the tumor and invaded bone was resected and the defect area was reconstructed with titanium mesh and calvarial bone graft. At 6 months postoperative the patient had no complications and was satisfied with the esthetic result. We report this case to demonstrate the successful approach and reconstruction using this technique.

티타늄과 ITO유리기판에 전착법으로 성장된 $Hg_{1-x}Cd_xTe$ 박막과 성장 조건이 결정구조 및 성분 조성비에 미치는 영향 (Influence of Growth Conditions on the Structural and Atomic Fractional Properties of $Hg_{1-x}Cd_xTe$ Films Electrodeposited onto Titanium and ITO glass)

  • 최춘태
    • 센서학회지
    • /
    • 제10권1호
    • /
    • pp.80-85
    • /
    • 2001
  • $Hg_{1-x}Cd_xTe$(MCT)박막을 $CdSO_4$, $TeO_2$, 및 $HgCl_2$이 혼합된 수용액을 사용하여 음극 전착법으로 ITO 유리와 티타늄기판 위에 성장하였다. 주된 박막의 성장 조건 변수로 전착전위와 성장 온도를 고려하였다. 전착된 MCT 박막은 SEM사진과 XRD 및 EPMA측정을 통하여 박막의 성장 조건이 결정 구조와 성분 조성비에 미치는 영향을 분석 연구하였다. XRD 분석으로부터 전착된 MCT 박막은 cubic zinc blonde 구조임을 알 수 있었고, EPMA에 의한 성분조성비의 분석결과로부터 전착전위를 변화시키므로서 MCT의 성분 조성비를 조절할 수 있음을 알 수 있었다.

  • PDF

Al합금과 Ti합금의 방탄특성에 관한 실험적 연구 (An Experimental Study on the Characters of Bullet Proof for Al and Ti Alloy)

  • 손세원
    • 한국자동차공학회논문집
    • /
    • 제13권4호
    • /
    • pp.113-120
    • /
    • 2005
  • In order to investigate the characteristics of penatration and the effect of surface treatment in A15052-H34, Al5082-Hl31 and titanium alloy laminates which were treated by anodizing and PVD(Physical Vapor Desposition) method, ballistic tests were conducted. Thickness of surface membrane in A15052-H34, Al5082-Hl31, were $25{\mu}m$ and that of titanium $0.9{\mu}m$ respectively. Surface hardness test was conducted using micro Vicker's hardness tester. Resistance to penetration is determined by the protection ballistic limit(V50), a statistical velocity with $50\%$ probability for complete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are observed from the results of V50 test and Projectile Through Plate(PTP) test at velocities greater than protection ballistic limit, respectively. Present experimental results derived from this research help to optimize laminate impact behavior by varing the laminate thickness and surface treated materials.

텅스텐아크용접에 의한 Zirconium의 동종 및 이종용접 특성 분석 (Similar and Dissimilar Welding Properties of Zirconium by TIG Welding)

  • 김진영;황효운;이대현;이재관;이동근
    • 열처리공학회지
    • /
    • 제34권4호
    • /
    • pp.165-170
    • /
    • 2021
  • Zirconium has excellent mechanical strength and high heat resistance and excellent corrosion resistance, and it is very important to study zirconium's dissimilar welding properties since it can be used in various applications under harsh environments. Similar welding of pure zirconium and dissimilar metal welding of pure zirconium and pure titanium were performed by TIG welding, and the welding properties were studied in association with microstructural and mechanical properties. In the Zr/Zr welded specimen, sound FZ and HAZ regions showed a basketweave microstructure composed of plate α phase. FZ region of Zr/Ti dissimilar welded specimen exhibited a maximum hardness value of 354.8 Hv, which is about three times higher than that of Ti base metal, due to the precipitation of very fine metastable ω and α phases in the beta matrix. In addition, due to the microstructural continuity in the FZ and HAZ regions, excellent elongation property of 21% was exhibited.

순 티탄늄 판재의 프레스 성형성 평가(제 1보) (Evaluation of press formability of pure titanium sheet)

  • 김영석;인정훈
    • 한국산학기술학회논문지
    • /
    • 제17권3호
    • /
    • pp.380-388
    • /
    • 2016
  • 본 논문에서는 판형 열교환기 등에 널리 이용되고 있는 순 티타늄 판재의 프레스 성형성을 평가하기 위해 인장실험을 수행하였고 인장실험결과를 가장 잘 피팅할 수 있는 가공경화 모델을 제안하였다. 또한 항복곡면의 도출을 위해 단축변형, 평면변형, 순수전단변형 등 다양한 변형모드 하에서의 인장실험을 실시하였다. 이 제안된 모델을 Hora의 수정된 최대하중조건식에 적용하여 프레스 성형성을 평가하기 위해서 널리 사용되고 있는 성형한계선을 예측하였고 그 결과를 장출성형실험에서 구한 성형한계선과 비교하였다. 도출한 항복곡면을 잘 묘사하기 위한 이방성 항복조건식과 본 연구에서 제안된 가공경화 모델은 순 티타늄 판재의 프레스 성형성의 척도인 성형한계선을 잘 예측함을 알 수 있었다.

Bone remodeling effects of Korean Red Ginseng extracts for dental implant applications

  • Kang, Myong-Hun;Lee, Sook-Jeong;Lee, Min-Ho
    • Journal of Ginseng Research
    • /
    • 제44권6호
    • /
    • pp.823-832
    • /
    • 2020
  • Background: The formation of a nanotube layer on a titanium nanotube (N-Ti) plate facilitates an active reaction between bone cells and the material surface via efficient delivery of the surface materials of the dental implant into the tissues. Studies have reported that Korean Red Ginseng extracts (KRGEs) are involved in a variety of pharmacological activities: we investigated whether implantation with a KRGE-loaded N-Ti miniimplant affects osteogenesis and osseointegration. Methods: KRGE-loaded nanotubes were constructed by fabrication on pure Ti via anodization, and MC3T3-E1 cells were cultured on the N-Ti. N-Ti implants were subsequently placed on a rat's edentulous mandibular site. New bone formation and bone mineral density were measured to analyze osteogenesis and osseointegration. Results: KRGE-loaded N-Ti significantly increased the proliferation and differentiation of MC3T3-E1 cells compared with cells on pure Ti without any KRGE loading. After 1-4 weeks, the periimplant tissue in the edentulous mandibular of the healed rat showed a remarkable increase in new bone formation and bone mineral density. In addition, high levels of the bone morphogenesis protein-2 and bone morphogenesis protein-7, besides collagen, were expressed in the periimplant tissues. Conclusion: Our findings suggest that KRGE-induced osteogenesis and osseointegration around the miniimplant may facilitate the clinical application of dental implants.

턱교정 수술에 있어 흡수성 고정판 및 나사 사용에 대한 임상적 연구 (CLINICAL STUDY ON USE OF BIODEGRADABLE PLATE AND SCREW IN ORTHOGNATHIC SURGERY)

  • 박성수;최진영
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.127-135
    • /
    • 2009
  • Objectives : The titanium fixation system has been used in orthognathic surgery for fixation of bone segments usually, but the biodegradable fixation system was developed and also being used. The strongest point in the biodegradable system is that no extra operation should be needed to remove fixation materials. In spite of this merit, oral & maxillofacial surgeons hesitate to use this system in fracture or orthognathic surgery. In this study, as we got some clinical experiences, we'd like to report the result of clinical study using the biodegradable fixation system in orthognathic surgery. Patients and Methods : A total of 35 patients composed of 17 males and 18 females with 25 osteotomies in maxilla and 34 osteotomies in mandible were fixated with the biodegradable fixation system(Inion $CPS^{(R)}$). We investigated methods of stabilization, fixation time, and complications on the basis of the method as above. Results : Four 2mm thick L shaped plates with 7 holes of which 1 hole was removed were fixed in maxilla with six $2.0{\times}7mm$ screws. Three $2.5{\times}16{\sim}18mm$ screws were used to fix superior ramus area and one mandibular angle area in mandible. It took about 27.4 minutes in maxilla, 25.3 minutes in mandible to perform the fixation which took longer time than the titanium system(9.5 minutes in maxilla, 8 minutes in mandible). Generally, there was no problem except 9 cases in which there were some complications. Conclusions : In most cases, the biodegradable fixation system can be used without problem in usual orthognathic surgery. But, this system is inferior to the titanium fixation one in some respects such as fixation time, size, and physical property. Some supplementations for such weak points as aforementioned should be needed for the universal use of biodegradable materials.

티타늄 판재의 파이버 레이저 용접시 공정변수에 따른 용접특성 (II) - 입열량 제어에 따른 영향 - (Weldability with Process Parameters During Fiber Laser Welding of a Titanium Plate (II) - The Effect of Control of Heat Input on Weldability -)

  • 김종도;김지성
    • 대한기계학회논문집A
    • /
    • 제40권12호
    • /
    • pp.1055-1060
    • /
    • 2016
  • 레이저 용접은 고밀도 용접법 중에 하나로 기존 용접방법에 비해 적은 입열로 깊은 용입과 빠른 용접속도를 얻을 수 있다. 연속 출력 파형 레이저 용접 시 입열량은 레이저 출력 및 용접속도에 의해 결정된다. 본 연구에서는 파이버 레이저를 사용하여 두께 0.5 mm의 순 티타늄 박판에 비드 및 겹치기 용접을 실시하였으며 레이저 출력 및 용접속도에 따른 용접성을 평가하였다. 레이저 출력 및 용접속도에 따른 용입깊이, 비드폭, 접합길이, 비드형상을 관찰하고 인장전단시험을 통해 기계적인 특성을 파악하였다. 실험결과, 겹치기 용접은 $P_L=0.5kW$, ${\nu}=2.5m/min$$P_L=1.5kW$, ${\nu}=6m/min$ 조건에서 양호한 접합길이를 가진 용접부를 얻을 수 있었으며, 용접부는 고출력보다 저출력 조건일 때 더 우수한 연성을 나타냈다.

Grade II 순수 타이타늄의 단시간 양극산화에 의한 TiO2 나노튜브 형성 (TiO2 Nanotubular Formation on Grade II Pure Titanium by Short Anodization Processing)

  • 이광민;김용재;강경호;윤두현;노상현;강석일;유대흥;임현필;윤귀덕;박상원;김현승
    • 한국재료학회지
    • /
    • 제23권4호
    • /
    • pp.240-245
    • /
    • 2013
  • Electrochemical surface treatment is commonly used to form a thin, rough, and porous oxidation layer on the surface of titanium. The purpose of this study was to investigate the formation of nanotubular titanium oxide arrays during short anodization processing. The specimen used in this study was 99.9% pure cp-Ti (ASTM Grade II) in the form of a disc with diameter of 15 mm and a thickness of 1 mm. A DC power supplier was used with the anodizing apparatus, and the titanium specimen and the platinum plate ($3mm{\times}4mm{\times}0.1mm$) were connected to an anode and cathode, respectively. The progressive formation of $TiO_2$ nanotubes was observed with FE-SEM (Field Emission Scanning Electron Microscopy). Highly ordered $TiO_2$ nanotubes were formed at a potential of 20 V in a solution of 1M $H_3PO_4$ + 1.5 wt.% HF for 10 minutes, corresponding with steady state processing. The diameters and the closed ends of $TiO_2$ nanotubes measured at a value of 50 cumulative percent were 100 nm and 120 nm, respectively. The $TiO_2$ nanotubes had lengths of 500 nm. As the anodization processing reached 10 minutes, the frequency distribution for the diameters and the closed ends of the $TiO_2$ nanotubes was gradually reduced. Short anodization processing for $TiO_2$ nanotubes of within 10 minutes was established.

Influence of kilovoltage- peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants

  • Fontenele, Rocharles Cavalcante;Nascimento, Eduarda Helena Leandro;Imbelloni-Vasconcelos, Ana Catarina;Martins, Luciano Augusto Cano;Pontual, Andrea dos Anjos;Ramos-Perez, Flavia Maria Moraes;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • 제52권3호
    • /
    • pp.267-273
    • /
    • 2022
  • Purpose: The aim of this study was to assess the influence of kilovoltage- peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. Materials and Methods: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). Results: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values(P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. Conclusion: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.