• Title/Summary/Keyword: Time-temperature indicator

Search Result 102, Processing Time 0.032 seconds

Development of a Time-temperature Indicator for Managing the Distribution Temperature of Frozen Mackerel Scomber japonicus (냉동 고등어(Scomber japonicus)의 유통 온도 관리를 위한 Time-temperature Indicator 개발)

  • Choi, Jeong-Wook;Lee, Min-Kyeong;Choi, Jae-Hyuk;Jang, Myung-Kee;Ahn, Dong-Hyun;Nam, Taek-Jeong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.51 no.5
    • /
    • pp.590-594
    • /
    • 2018
  • We developed a time-temperature indicator (TTI) that rapidly determines whether frozen mackerel Scomber japonicus has thawed during its distribution. Our TTI was made from filter paper capable of absorbing mackerel exudate that was soaked in a 20% citric acid solution at pH 4.0 and then dried. The dried absorbent paper was cut and attached to blue litmus paper with a 2 mm overhang. The fixed litmus paper was covered with a polypropylene film and sealed. The indicator was placed inside a polyvinyl vacuum package containing the mackerel sample. The vacuum-sealed packaged was frozen at $-20^{\circ}C$ for 24 h. After freezing, the color change and time dependence of the indicator were observed at room temperature ($25^{\circ}C$) and demonstrated the utility of this TTI for rapidly determining whether frozen mackerel underwent thawing during distribution.

A Time-temperature Indicator for A Vision Based-Detection System for Managing the Storage Temperature of Frozen Fish Products (냉동 수산물의 저장 온도 관리를 위한 Time-temperature Indicator와 비전 기반 Indicator 분석 프로그램 개발)

  • Jang, Myung-Kee;Hong, Chang-Wook;Choi, Jae-Hyuk;Kim, Koth-Bong-Woo-Ri;Choi, Jeong-Wook;Nam, Taek-Jeong;Ahn, Dong-Hyun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.51 no.1
    • /
    • pp.91-94
    • /
    • 2018
  • We develop a time-temperature indicator (TTI) that can determine whether thawing of fish and other fishery products has occurred during frozen storage. A polypropylene tube with an internal diameter of 3 mm was prepared and cut to a length of 14 to 20 mm. One end of the tube was thermally sealed and 0.1% acetic acid was injected into the other end; the tube was then frozen at $20^{\circ}C$. Then the open side of the frozen tube was blocked by sinking the tube into a 10% gelatin solution. The tube was attached to a polyvinyl packaging bag along blue litmus paper and the bag was put into a freezer at $-20^{\circ}C$. After freezing, the bag was removed to an ambient temperature of $20^{\circ}C$, and the time dependence of the color change of the litmus paper was observed. The color changed from blue to red, with the length of the red region increasing with time. Our TTI can be used as a part of a visible detection system and the detection program can conduct the elapsed time analysis on the length of the red region of the litmus paper indicating the degree of thawing. Thus, the TTI is a useful tool in the temperature management of frozen fish and fishery products.

Virtual Simulation of Temperature Distribution throughout Beef Packages with Time-temperature Indicator (TTI) Labels

  • Kim, Min-Jung;Min, Sang-Gi;Lee, Seung Ju
    • Food Science of Animal Resources
    • /
    • v.33 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • If the time-temperature indicator (TTI) experienced a different temperature than the accompanied packaged food, influenced by heat transfer between the TTI, package, and ambient air, TTI would incorrectly predict the food quality changes with temperature. Temperature distributions of a finite slab with different sizes, representing beef packaged with TTI, were estimated by the finite element method (FEM). The thermal properties of the beef and TTI, such as heat capacity, density, and heat conductivity, were estimated from the relevant equations using their chemical compositions. The FEM simulations were performed for three cases: different locations of TTIs on the beef, different thicknesses of beef, and non-isothermal conditions of ambient air. The TTIs were mounted in four different locations on the beef. There was little difference in temperature between four locations of the TTI on the package surface. As the thickness of the slab increased, the temperature of the TTI changed faster, followed by the corner surface, as well as middle and bottom parts, indicating the possible error for temperature agreement between the TTI and the slab. Consequently, it was found that any place on the package could be selected for TTI attachment, but the package size should carefully be determined within a tolerable error of temperature.

Reliability Assessment of Temperature Indicator for Simplified Measurement on Conservation Environment of Cultural Heritage (문화재 보존환경 간이 측정을 위한 온도지시카드 신뢰성 평가)

  • Lim, Bo-A;Shin, Eun-Jeong;Lee, Sun-Myung
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.59-68
    • /
    • 2010
  • Cultural heritages are damaged by surrounding several environmental factors. Main factors are temperature, humidity, light, atmosphere and indoor pollutant, organism, etc. Therefore, to prevent damage of cultural heritage from such environmental factor, conservation environment monitoring becomes more important. Indicator is one of the simple method for environment monitoring. It can be used without expensive and complex equipments. However, it should be performed scientific examination for application to cultural heritage. In this study, some Temperature Indicators were chosen and reliability assessment was carried out for application to cultural heritage. Brightness($L^*$) is selected for reliability assessment factor. As a result of lab test, Temperature Indicators were not influenced greatly in humidity change. When they were exposed to setting temperature, the color was changed in setting temperature area and ${\pm}2^{\circ}C$ part of setting temperature. Especially brightness value was high in setting temperature area. Also, Temperature Indicators were stabilized after about 16 minutes when were exposed to temperature difference of $10^{\circ}C$ and when temperature difference with exposure environment is smaller, stabilization time shortened. Therefore, it is a possible to confirm that selected Temperature Indicator is reliable product through measurement of color difference value and naked eye observation.

  • PDF

Application of a Prototype of Microbial Time Temperature Indicator (TTI) to the Prediction of Ground Beef Qualities during Storage

  • Kim, Yeon-Ah;Jung, Seung-Won;Park, Hye-Ri;Chung, Ku-Young;Lee, Seung-Ju
    • Food Science of Animal Resources
    • /
    • v.32 no.4
    • /
    • pp.448-457
    • /
    • 2012
  • The predictive ability for off-flavor development and quality change of ground beef was evaluated using a microbial time temperature indicator (TTI). Quality indices such as off-flavor detection (OFD) time, color, pH, volatile basic nitrogen (VBN), aerobic mesophilic bacteria (AMB) counts, and lactic acid bacteria (LAB) counts were measured during storage at 5, 10, 15, and $25^{\circ}C$, respectively. Arrhenius activation energies (Ea) were estimated for temperature dependence. The Ea values for TTI response (changes in titratable acidity (TA)), VBN, AMB counts, LAB counts, and freshness, which is defined based on OFD time for quality indices of ground beef, were 106.22 kJ/mol, 58.98 kJ/mol, 110.35 kJ/mol, 116.65 kJ/mol, and 92.73 kJ/mol, respectively. The Ea of microbial TTI was found to be closer to those of the AMB counts, LAB counts, and freshness. Therefore, AMB counts, LAB counts, and freshness could be predicted accurately by the microbial TTI response due to their Ea similarity. The microbial TTI exhibited consistent relationships between its TA change and corresponding quality indices, such as AMB counts, LAB counts, and freshness, regardless of storage temperature. Conclusively, the results established that the developed microbial TTI can be used in intelligent packaging technology for representing some selected quality indices of ground beef.

The Predicton of the Shelf-life of Packaged Meals (Kim Pab) Marketed in Covenience Stores Using Simulation Study (모의실험을 통한 편의점 판매용 김밥 도시락의 유통기한 예측)

  • 곽동경;김성희
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.3
    • /
    • pp.189-196
    • /
    • 1996
  • Based on microbiological-chemical test results under simulated time-temperature conditions, total plate count, coliform, and volatile basic nitrogen were selected as effective quality indicators for estimating probable shelf-life on Kim Pab dosirak marketed in convenience stores, and shelf-life at each storage temperature was calculated from regression equation between effective quality indicator standard limit and storage time. Estimated shelf lives of Kim Pab Dosirak were 17, 3 and 2 hours respectively under 1$0^{\circ}C$, 2$0^{\circ}C$ and 3$0^{\circ}C$. Because shelf-life was especially affected by intial values, regression analysis between initial effective quality indicator values and storage hours was performed for the estimation of probable shelf-life on Kim Pab during storage at 10, 20, or 3$0^{\circ}C$.

  • PDF

Printable Time Temperature Integrator Consisting of Oxygen Indicator and Cover Film with Various Oxygen Permeability (다양한 산소 투과도를 가진 커버필름과 산소지시물질로 제작된 인쇄형 TTI)

  • Kim, Do Hyeon;Jang, Han Dong;Han, Seo Hyeon;Ahn, Myung Hyun;Lee, Seung Ju
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.24 no.2
    • /
    • pp.41-48
    • /
    • 2018
  • A printable time temperature integrator (TTI) consisting of oxygen indicator and cover films with various oxygen permeability was developed. The printing ink contained methylene blue (oxygen indicator) which changed in color during storage. $TiO_2$ and glycerol for UV-activation of TTI and zein and ethanol for printing performance were also contained in the printing ink. The cover film on the ink was employed to control the color change rate and temperature dependency (Arrhenius activation energy, $E_a$) by using the different films (PE, PET, OPP, and LLDPE). The film properties were varied by annealing. TTI was produced by silk screen printing. As a result, the color change rates were different for the cover films, being the highest in TTI with LLDPE, followed by OPP, PE, and PET. The rate decreased with increase in the cover film thickness. The $E_a$ was the highest in TTI with LLDPE, followed by OPP, PE, and PET. The $E_a$ did not change with the cover film thickness. The annealed PVC and PET film were lower in oxygen permeability than the unannealed ones, indicating the lower color change rate.

Relationships between BMI, Body Temperature and Syrnpathoadrenal Activity during a Meal (식사시의 교감-부신계 활성도와 체온 및 신체계측치와의 관련성)

  • 김석영;임상선;박필숙
    • Journal of Nutrition and Health
    • /
    • v.31 no.7
    • /
    • pp.1130-1138
    • /
    • 1998
  • The objective of this study was to investigate the relationship between changes in body temperature, adiposity and sympathoadrenal activity in normal weight female college students, eating an instant-noodle lunch in a laboratory setting at ambient temperatures of 22-24.8$^{\circ}C$. Preprandial epinephrine(EPI) concentration, as an indicator of adrenal activity, was inversely and significantly correlated with body weight, body mass index(BMI), and waist girth. Changes in pre- and postprandial EPI concentrations showed positive correlations with % body fat, fat mass, waist girth, hip girth, and waist/hip girth ratio(WHR). The preprandial norepinephrine (NE) concentration was negatively correlated with recovery time from the peak postprandial core temperature to the meal-start core temperature(RTST). However, the NE concentration, an indicator of sympathetic neural activity, was not related to anthropometric measurements in normal weight young women. In conclusion, adrenal activity was negatively associated with adiposity and central body fat distribution. Sympathetic activity was related to body temperature regulation capacity after a meal, but was not related to adiposity in normal weight young women. (Korean J Nutrition 31(7) 1130-1138, 1998)

  • PDF

Effect of Cooking on the Food Safety of Cutlet - Changes of Internal Temperature, Color, and Indicator Organisms - (가열 처리에 따른 커틀릿의 식품안전성 확보 조건 - 내부 중심온도, 색도 및 위생지표미생물을 중심으로 -)

  • Kim, Jong-Gyu;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.82-89
    • /
    • 2015
  • Objectives: This study was performed to investigate the effect of cooking time on the internal temperature and color of cutlets and the reduction of indicator organisms in cutlets by cooking. Methods: Three kinds of commercially packed frozen cutlets (pork, chicken and fish cutlets), were purchased from local markets. The cutlets were cooked in a frying pan at $180^{\circ}C$ for four minutes. Internal temperature was measured with a food thermometer. Color was measured using a Hunter spectrocolorimeter. Aerobic colony counts, coliforms, and Escherichia coli were determined according to the Food Code of Korea. Results: The internal cooked temperature of every cutlet reached over $74^{\circ}C$, the temperature considered safe, after three minutes, while external temperature reached this level in two minutes (p < 0.001). The instrumental color value as lightness (L) in the cooked cutlets significantly changed (p < 0.001) after one minute. The level of aerobic colony counts of fresh cutlets was under the specification and was reduced to one tenth its level in the cooked cutlets. Coliforms and E. coli were not detected in all samples. The internal temperature of the cutlets was significantly affected by cooking time and weight (p < 0.001). The interaction effect of time and weight was also significant (p < 0.001), and time was the more influential factor. Conclusion: The results of this study indicate that the sampled cutlets should be cooked for a minimum of three minutes or more in order to ensure food safety. The results also indicate that if consumers cease cooking based on external temperature or color, there will be a risk of inadequate cooking.