• Title/Summary/Keyword: Time step

Search Result 5,412, Processing Time 0.039 seconds

Identification of Three-Parameter Models from Step Response (스텝응답을 이용한 3매개변수 모델의 식별)

  • Ali, Mohammed Sowket;Lee, Jun-Sung;Lee, Young-Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.12
    • /
    • pp.1189-1196
    • /
    • 2010
  • This paper provides an identification method for three-parameter models i.e. first order with dead time models and second order with dead time models. The proposed identification method is based on step response and can be easily implemented using digital microprocessors. The proposed method first identifies the order of the plant i.e. first order or second order from the behavior of the plant with constant input. After the order of the plant is determined, a test step input is applied to the system and the three parameters of the plant are obtained from the corresponding response of the plant. The output of the plant need not to be zero when the test signal is applied. The efficacy of proposed algorithms is verified through simulation and experiment.

Development and Assessment of Real-Time Quality Control Algorithm for PM10 Data Observed by Continuous Ambient Particulate Monitor (부유분진측정기(PM10) 관측 자료 실시간 품질관리 알고리즘 개발 및 평가)

  • Kim, Sunyoung;Lee, Hee Choon;Ryoo, Sang-Boom
    • Atmosphere
    • /
    • v.26 no.4
    • /
    • pp.541-551
    • /
    • 2016
  • A real-time quality control algorithm for $PM_{10}$ concentration measured by Continuous Ambient Particulate Monitor (FH62C14, Thermo Fisher Scientific Inc.) has been developed. The quality control algorithm for $PM_{10}$ data consists of five main procedures. The first step is valid value check. The values should be within the acceptable range limit. Upper ($5,000{\mu}g\;m^{-3}$) and lower ($0{\mu}g\;m^{-3}$) values of instrument detectable limit have to be eliminated as being unrealistic. The second step is valid error check. Whenever unusual condition occurs, the instrument will save error code. Value having an error code is eliminated. The third step is persistence check. This step checks on a minimum required variability of data during a certain period. If the $PM_{10}$ data do not vary over the past 60 minutes by more than the specific limit ($0{\mu}g\;m^{-3}$) then the current 5-minute value fails the check. The fourth step is time continuity check, which is checked to eliminate gross outlier. The last step is spike check. The spikes in the time series are checked. The outlier detection is based on the double-difference time series, using the median. Flags indicating normal and abnormal are added to the raw data after quality control procedure. The quality control algorithm is applied to $PM_{10}$ data for Asian dust and non-Asian dust case at Seoul site and dataset for the period 2013~2014 at 26 sites in Korea.

EXPERIMENTAL STUDY OF INFLUENCE ON RADIOGRAPHIC DENSITY AND CONTRAST BY THE CHANGE OF KILOVOLTAGE AND EXPOSURE TIME (관전압과 X선노출시간의 변화가 X선사진의 흑화도와 대조도에 미치는 영향에 관한 실험적 연구)

  • Lee Byeong Do;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.113-124
    • /
    • 1990
  • For the study of the influence of kilovoltage and exposure time on radiographic density and contrast, we measured radiographic density of aluminum step wedge which composed of contiguous 8 steps wedges of 2-16㎜ thickness with densitometer. Aluminum step wedge was radiographed on Kodak ultraspeed DF-58 and Ektaspeed EP-21 film with range of 60-90 kVp and 5-60 impulse and subject contrast of aluminum step wedge with constant radiographic density and image contrast percentage without radiographic density was evaluated. Then we evaluated the film quality of teeth and their surrounding structure according to the change of kVp and exposure time by score rating method. The obtained results were as follows: 1. Radiographic density was related to the change of kilovoltage, especially in increased exposure time. 2. With constant radiographic density, subject contrast of thin aluminum step wedges was greater in low kilovolt age than high kilovoltage, but kilovolt age had not great influence on subject contrast of thick aluminum step wedge. On the other hand, radiographic density difference between 2mm and 16mm aluminum step wedge was decreased according to in- creasing kilovoltage. 3. Without constant radiographic density, image contrast percentage was decreased with increasing kilovoltage, but was not related with the change of exposure time. 4. Radiographic contrast of teeth and their surrounding structure which was taken with the range of 60-90 kVp and 6-30 impulse had not great influence on film quality.

  • PDF

Effect of Step-up and Step-down Hyperthermia on Skin of Mice (온열요법시 온도변화가 정상조직에 미치는 영향)

  • Choi, Ihl-Bohng;Kim, Choon-Yul;Bahk, Yong-Whee
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.155-161
    • /
    • 1988
  • The usefulness of hypertermia for cancer therapy have well been established. The purpose of the present investigation was to ascess the effect of step-up $(42^{\circ}{\rightarrow}44^{\circ}C$ sequence) and step-down $(44^{\circ}{\rightarrow}42^{\circ}C$ sequence) heating on the skin of the hind foot of the mouse. Hyperthermic treatments were given by immersion the hind foot of the mouse in circulating water baths. Skin response was studied by the leg reaction, which was scored according to a numerical scoring system proposed by Urano et al (1980). The results were as follows 1. The skin damage of $44^{\circ}C$ control group was more severe than $42^{\circ}C$ control group (P<0.05), except for 15 min. heating group. 2. The Skin damage of step-down group was more severe than step-up group (P<0.05). 3. The skin damage of $44^{\circ}C$ control group was more severe than step-up group when there is no difference in $44^{\circ}C$ heating time of step-up group from $44^{\circ}C$ control group (P<0.05). 4. In step-down group, the skin damage was more severe than $44^{\circ}C$ control group after preheating 45 min at $44^{\circ}C$ (P<0.05). Therefore, the above findings suggest the normal tissue damage by step-up heating was correlated with heating time of post step-up. The dropping of heating temperature in late phase had more severe damage of the skin than that in early phase during hyperthermia, and so contineous control of satisfactory temperature should be considered as the one of the most important factor for prognosis, complications of clinical hyperthermia

  • PDF

Analysis of Foods and Nutrients Intake Obtained at the Final Probing Step in 24-hour Recall Method (24시간 회상법을 사용한 한국 성인의 식이섭취조사에서 재회상 단계 추가의 영향 분석)

  • Kang, He-Ra;Jung, Hyun-Ju;Paik, Hee-Young
    • Journal of Nutrition and Health
    • /
    • v.42 no.2
    • /
    • pp.158-170
    • /
    • 2009
  • This study was conducted to examine the usefulness of adding final probing step (step3) in dietary assessment by 24-hour recall method among Korean adults. One-hundred fifty five adults (37 males and 118 females) above 30 years of age who visited hospitals for health examination were recruited at three hospitals in Korea. One day dietary intake was obtained using 24-hour recall method from each subject. Dietary interview was conducted in 3 steps, (1) quick list of foods eaten during the previous day, (2) detailed information of all the foods eaten, (3) the final probing for any items forgotten. Items added at the step3 were identified and contributions of energy and nutrient intakes were calculated. The average duration of interview was 10.5 min, and time spent for each step was 4.12 minute for step 1, 5.62 minute for step 2, and 38 second for step 3. The average number of dishes reported by the subjects added at the step 3 was 2.2. (Males = 2.6, Females = 1.6) Frequently reported dishes in the step 3 were Beverage, Tea, alcohol (37.1%) and Fruits (31.8%). From mean total energy intake of 1,589 kcal (Men = 1,846 kcal, Women = 1,509 kcal), 179 kcal (11.3%) was added at the step 3. In the step 3, nutrient intakes increased significantly except retinol in total subjects and except retinol and cholesterol in males but all nutrients increased significantly in females. The final probing step can add significant information on intakes of foods and many nutrients with only about 38 seconds of interview time. Confirmation of the results with larger samples of different age groups is needed.

A Walsh-Hadamard Transform Adaptive Filter with Time-varying Step Size. (가변 스텝사이즈를 갖는 월시-아다말 변환 적응 필터)

  • 오신범;이채욱
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1175-1178
    • /
    • 1998
  • we propose the Walsh-Hadamard Transform adaptive filter with time-varying step size. The performance of the proposed algorithm is evealuated in system identification where computer simulations are performed for both time-invariant and time-varying system. It is shown that the proposed algorithm produces good results compared with similar algorithms under different conditions, particularly in case of time-varying circumstance.

  • PDF

The Influence of Compression Holding Step on Mechanical Properties of Products in Closed-Die Compression Process for Semi-Solid Material (반융용 재료의 밀폐 압축 공정에서 가압유지 단계가 제품의 기계적 성질에 미치는 영향)

  • 최재찬;박형진;이병목
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.199-203
    • /
    • 1995
  • The technology of Semi-Solid Forging (SSF) has been actively developed to fabricate near-net- shape products using light and hardly formable materials, the SSF process is composed of slug heating, forming, compression holding and ejecting step. After forming step in SSF, the slug is compressed during a certain holding time in order to be completely filled in the die cavity and be accelerated in solidification rate. The compression holding time that can affect mechanical properties and shape of products is important to make decision, where it is necessary to find overall hert transfer coefficeient properly which has large effect on heat transfer between slug and die. This paper presents the procedure to predict compression holding time of octaining the final shaped part with information of temperature and solid fraction for a cylindrical slug at compression hoiding step in closed-die compression process using heat transfer analysis considering latent heat by means of finite element method. The influence of the predicted compression hoiding time on mechanical properties of products is finally investigated by experiment.

  • PDF

Finite Element Solution of Ordinary Differential Equation by the Discontinuous Galerkin Method (불연속 갤러킨 방법에 의한 상미분방정식의 유한요소해석)

  • 김지경
    • Computational Structural Engineering
    • /
    • v.6 no.4
    • /
    • pp.83-88
    • /
    • 1993
  • A time-discontinuous Galerkin method based upon using a finite element formulation in time has evolved. This method, working from the differential equation viewpoint, is different from those which have been generally used. They admit discontinuities with respect to the time variable at each time step. In particular, the elements can be chosen arbitrarily at each time step with no connection with the elements corresponding to the previous step. Interpolation functions and weighting functions are taken to be discontinuous across inter-element boundaries. These methods lead to a unconditional stable higher-order accurate ordinary differential equation solver.

  • PDF

A Comparative Study of PISO, SIMPLE, SIMPLE-C Algorithms in 3-dimensional Generalized Coordinate Systems (3차원 일반 좌표계에서의 PISO, SIMPLE, SIMPLE-C 알고리즘의 비교)

  • Park J. Y.;Baek J. H.
    • Journal of computational fluids engineering
    • /
    • v.1 no.1
    • /
    • pp.26-34
    • /
    • 1996
  • The performance of the SIMPLE, SIMPLE-C and PISO algorithms for the treatment of the pressure-velocity coupling in fluid flow problems were examined by comparing the computational effort required to obtain the same level of the convergence. Example problems are circular duct and 90-degree bent square-duct. For circular duct case, laminar and turbulent flow were computed. For 90-degree bent square-duct case, laminar flow was simulated by the time-marching method as well as the iterative method. The convergence speed of the other two algorithms are not always superior to SIMPLE algorithm. SIMPLE algorithm is faster than SIMPLE-C algorithm in the simple laminar flow calculations. The application of the PISO algorithm in three dimensional general coordinates is not so effective as in two-dimensional ones. Since computational time of PISO algorithm is increased at each time step(or iterative step) in three dimension, the total convergence speed is not decreased. But PISO algorithm is stable for large time step by using time marching method,.

  • PDF

A Protection Algorithm for DC Railway Systems Using Estimation of Time Constant Based on Fourier Transform (Fourier 변환 기반 시정수 추정 알고리즘을 이용한 직류 급전계통 보호 알고리즘)

  • Kwon, Y.J.;Choi, D.M.;Kang, S.H.;Han, M.S.;Lee, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.14-16
    • /
    • 2004
  • A DC railway system has low feeder voltage, The remote fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases all at once. As for the load starting current, the time constant of load current at each step is much smaller than that of the fault current. To detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares was presented. But, It have a weakness about harmonic to calculate time constant. So in this paper, new protection algorithm for DC railway systems using estimation of time constant based on fourier transform was presented.

  • PDF