• Title/Summary/Keyword: Thyroid Dose

Search Result 300, Processing Time 0.024 seconds

A Study on the Radiation Dose of $^{131}I$ in the Thyroid Gland during the Treatment of Hyperthyroidism (갑상선 기능항진증의 $^{131}I$ 치료시 갑상선 조사량에 관한 연구)

  • Suh, Hwan-Jo;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.9 no.1
    • /
    • pp.59-71
    • /
    • 1975
  • 53 patients with hyperthyroidism have been analyzed with special reference to therapeutic response to radioactive iodine ($^{131}I$) treatment. Mean effective half-life, 24 hour uptake rate and radiation dose of $^{131}I$ in hyperthyroid patients included in this study were respectively. 1. Mean effective half-life of $^{131}I\;was\;4.7{\pm}1.5$ days in the tracer dose and $5.0{\pm}1.5$ days in the therapeutic dose. 2. Mean 24 hour uptake rate of $^{131}I\;was\;72.7{\pm}11.1%$ in the tracer dose and $73.4{\pm}12.3%$ in the theapeutic dose. 3. Mean radiation dose of $^{131}I\;was\;5,319{\pm}2,648$ RAD as predicted and $5,692{\pm}2,843$ RAD as actual. A single dose of radioactive iodine treatment was satisfactory in 34 patients (radioiodine sensitive) and multiple doses of radioactive iodine treatments were required in 19 patients (radioiodine resistant). A radioiodine resistant group of patients with hyperthyroidism was distinctively characteristic in the following aspects. 1. Mean thyroid weight calculated in the resistant group ($63.9{\pm}14.0gm$) was significantly (p<0.01) greater than that of the sensitive group ($46.6{\pm}13.3gm$). 2. Mean 24 hour uptake rate of the tracer dose in the resistant group ($67.3{\pm}10.7%$) was significantly (p<0.01) lower than that of the sensitive group ($75.7{\pm}10.5%$). 3. Mean 24 hour uptake rate of the therapeutic dose in the resistant group ($68.5{\pm}13.7%$) was significantly (p<0.05) lower than that of the sensitive group ($76.1{\pm}10.9%$). 4. Mean predicted radiation dose, of $^{131}I$ in the resistant group ($3,684{\pm}1,745$ RAD) was significantly (p<0.01) lower than that of the sensitive group ($6,232{\pm}2,683$ RAD). 5. Mean actual radiation dose of $^{131}I$ in the resistant group ($4,100{\pm}1,691$ RAD) was significantly (p<0.01) lower than that of the sensitive group ($6,582{\pm}3,024$ RAD). 6. No significant difference was detected in terms of effective half-life of $^{131}I$ among the groups (p>0.05). 7. The average mean % difference of effective half-life, uptake rate and radiation dose measured following the tracer and therapeutic dose of $^{131}I$ were not statistically significant (p>0.05). Therefore effective half-life, uptake rate and radiation dose of the therapeutic dose of $^{131}I$ were readily predictable following the tracer dose of $^{131}I$. 8. It is concluded that the possibility of resistance to radioactive iodine treatment may be anticipated in patients with thyroid gland large in size and compromised $^{131}I$ uptake rate.

  • PDF

Absorbed Dose Measurement by the MIRD System in the $^{131}I$ Treated Thyroid Cancer Patients (갑상선 암 환자에서 $^{131}I$ 치료시 MIRD Schema에 의한 흡수선량의 평가)

  • Lim, Sang-Moo;Woo, Kwang-Sun;Chung, Wee-Sup;Hong, Sang-Woon;Kim, Jang-Hee;Kim, Ki-Sup
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.54-60
    • /
    • 1995
  • Medical Internal Radiation Dose(MIRD) schema was developed for calculating the absorbed dose from the administered radiopharmaceuticals. With the biological distribution data and the physical properties of the radionuclide we can estimate the absorbed dose by the MIRD schema. For the thyroid cancer patients received $^{131}I$ therapy, the absorbed dose to the bone marrow is the limiting factor to the administered dose, and the duration of admission is deter-mined by the retained activity in the whole body. To monitor the whole body radioactivity, we used Eberline Smart 200 system using ionization chamber as a detector. With the time activity curve of the whole body, total body residence time was obtained. From the ICRP publication 53, the residence times of the source organs, such as kidney, urinary bladder content and stomach, were used to calculate the absorbed doses of the target organs, such as stomach, red marrow, bladder wall and remaineder total body. In 8 thyroid cancer patients with 175 mci of $^{131}I$ administered orally, the mean absorbed dose in the bladder wall was 375.1, in the stomach 285.1, red marrow 25.4 and total body 22.4 rad respectively. For the monitoring of the large administered activity, this method seemed to be quite useful.

  • PDF

Effect of Sulfamonomethoxine on Thyroid Function of Rabbits (Sulfamonomethoxine (SMM) 투여(投與)가 가토(家兎)의 갑상선기능(甲狀線機能)에 미치는 영향(影響))

  • Lee, Dong-Myoung
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.65-69
    • /
    • 1985
  • In order to investigate the effects of sulfamonomethoxine (SMM) on thyroid glands in short term administration as medical dose, a total of twenty albino rabbits (mean body weight 1,750g) were selected at random and allotted to control and experimental group. Rabbits in experiment were administered SMM of 50 mg/kg/day for 30 days, and histopathological changes of thyroid glands and the blood levels for T4 and T3 were observed every 5 days. The Results obtained were summarized as follows: 1. The thyroid follicles were decreased or obliterated by highly hypertrophic and hyperplastic epithelial cells and the newly formed small follicles contained scanty colloidal materials. These changes revealed increasing tendency in accordance with the experimental days. 2. The blood levels for T4 and T3 of experimental group manifested significantly decreased values than those of control through the experimental term consistently. Finally, above observations suggest that administration of SMM to animals leads thyroid glands to typical hypofunctional hyperplastic goiter.

  • PDF

Management of Severe Fatigue Induced by Tyrosine Kinase Inhibitor in Radioiodine Refractory Thyroid Cancer (방사성요오드 불응성 갑상선암에서 티로신키나아제 억제제 투여로 유발된 중증 피로감의 관리)

  • Ahn, Byeong-Cheol
    • International journal of thyroidology
    • /
    • v.11 no.2
    • /
    • pp.75-77
    • /
    • 2018
  • Tyrosine kinase inhibitor is known to prolong progression free survival in radioiodine refractory thyroid cancer patients. Fatigue/asthenia/malaise is one of most common adverse events by the tyrosine kinase inhibitor treatment, and management of the adverse event is important to keep the drug medication longer which is essential for the survival benefit. In the case report, a radioiodine refractory thyroid cancer patient receiving tyrosine kinase inhibitor experienced severe fatigue, and a pathologic fracture of right humerus occurred by slipping down which was tightly linked with the adverse event of the drug. The pathologic fracture was surgically well managed and the adverse event was well controlled by supportive managements combined with dose reduction of the tyrosine kinase inhibitor. The drug administration to the patient was kept more than 1 year without progression of the disease.

Effects of Lonicerae Flos on the 6-n-propyl-2-thiouracil (PTU)-induced Rat Hypothyroidism (금은화가 6-n-propyl-2-thiouracil (PTU) 로 유발된 흰쥐의 갑상샘 기능저하증에 미치는 영향)

  • Ku, Sae-Kwang;Lee, Young-Joon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.4
    • /
    • pp.630-637
    • /
    • 2010
  • The object of this study was to evaluate the effect of Lonicerae Flos, aqueous extracts of the dried flower bud part of Lonicera japonica on the 6-n-propyl-2-thiouracil (PTU)-induced rat hypothyroidism. Aqueous extracts of Lonicerae Flos (LF yield = 23.80%) were administered, once day for 42 days from 2 weeks before start of PTU treatment as an oral dose of 500 and 250 mg/kg (body weight), and hypothyroidism was induced by daily subcutaneous treatment of PTU 10 mg/kg for 28 days. The changes on the body weight, thyroid gland weights, serum thyroid hormone - thyroid stimulating hormone (TSH), tri-iodothyronine ($T_3$) and thyroxine ($T_4$), serum lipid profiles - total cholesterol, low density lipoprotein (LDL), high density lipoprotein (HDL) and triglyceride were observed with liver antioxidant defense system - lipid peroxidation, $H_2O_2$, superoxide dismutase (SOD) and catalase (CAT) and serum asparte aminotransferase (AST) and alanine aminotransferase (ALT) analysis. Results were compared with Levothyroxine ($LT_4$) 0.5 mg/kg treated rats. As results of PTU treatment, marked decreases of body weights, serum thyroid hormone levels and triglyceride contents, liver $H_2O_2_3$ and SOD activities were observed with increases of serum AST and HDL contents, liver CAT activities, thyroid gland weight. However, these PTU induced hypothyroidism were dose-dependently inhibited by treatment of LF extracts, and LF extracts effectively regulated the hypothyroidism related changes on the antioxidant defense system. The results obtained in this study suggest that LF extracts have favorable effects on the thyroid hormone productions with beneficial effects on the hypothyroidism mediated by the modulatory effects on the antioxidant defense system.

Detection for Residual Thyroid Tissue and Metastatic Lesion after Total Thyroidectomy in Patients with Differentiated Thyroid Cancer: Comparison between Tc-99m Pertechnetate Sean and High Dose I-131 Therapy Sean (분화 갑상선암 환자의 수술후 잔여갑상선조직 및 전이병소의 진단: Tc-99m Pertechnetate 스캔과 고용량 옥소 치료 후 I-131 스캔의 비교)

  • Lee, Joo-Ryung;Ahn, Byeong-Cheol;Jeong, Shin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.120-127
    • /
    • 2003
  • Purpose: To evaluate diagnostic sensitivity of nuclear imaging in the detection of residual thyroid tissue and metastatic lesion, we have compared neck scintigrams with Tc-99m pertechnetate (Tc-99m scan) and high dose I-131 iodide (I-131 scan) in patients with differentiated thyroid cancer. Subjects and Methods: One hundred thirty-five thyroidectomized patients for differentiated thyroid cancer were enrolled in this study. Twenty-three had a previous history of radioiodine therapy. Planar and pin-hole images of anterior neck with Tc-99m were acquired at 20 minutes after injection, followed by I-131 scan three days after high-dose radioiodine therapy within 7 days interval. Patients were asked to discontinue thyroid hormone replacement more than 4 weeks. Results: All subjects were in hypothyroid state. Seventy out of 135 patients (51.9%) showed concordant findings between Tc-99m and I-131 scans. I-131 scan showed higher number of uptake foci in all of 65 patients showing discordant finding. Tc-99m scan showed no thyroid bed uptake in 34 patients, whereas 23 of them (67.6%) showed bed uptake in I-131 scan. Tc-99m scan did not show any uptake in thyroid bed in 11 of 112 patients without previous history of radioiodine therapy, but 9 of them showed bed uptake in I-131 scan. Tc-99m scan showed no bed uptake in all of the 23 patients with previous history of radioiodine therapy, in contrast 14 of them (60.9%) showed bed uptake in I-131 scan. Conclusion: These results suggest that Tc-99m scan has poor detectability for residual thyroid tissue or metastatic lesion in thyroidectomized differentiated thyroid cancer patients, compared to high dose I-131 therapy scan. Tc-99m scan could not detect any remnant tissue or metastatic lesion in patients with previous history of radioiodine treatment, especially.

RADIATION DOSE TO HUMAN AND NON-HUMAN BIOTA IN THE REPUBLIC OF KOREA RESULTING FROM THE FUKUSHIMA NUCLEAR ACCIDENT

  • Keum, Dong-Kwon;Jun, In;Lim, Kwang-Muk;Choi, Yong-Ho
    • Nuclear Engineering and Technology
    • /
    • v.45 no.1
    • /
    • pp.1-12
    • /
    • 2013
  • This paper describes the radiation doses to human and non-human biota in the Republic of Korea, as a result of the Fukushima nuclear accident. By using the measured airborne activity and ground deposition, the effective and thyroid doses of five human age groups (infant, 5 years, 10 years, 15 years and adult) were estimated by the ECOSYS code, and the whole body absorbed dose rate of the eight Korean reference animals and plants (RAPs) was estimated by the K-BIOTA (the Korean computer code to assess the risk of radioactivity to wildlife). The first-year effective and thyroid human doses ranged from 5.7E-5 mSv in the infant group to 2.0E-4 mSv in the 5 years group, and from 5.0E-4 mSv in the infant group to 3.4E-3 mSv in the 5 years group, respectively. The life-time (70 years) effective and thyroid human doses ranged from 1.5E-4 mSv in the infant group to 3.0E-4 mSv in the 5 years group, and from 6.0E-4 mSv in the infant group to 3.5E-3 mSv in the 5 years group, respectively. The estimated maximum whole body absorbed dose rate to the Korean RAPs was 6.7E-7 mGy/d for a snake living in soil (terrestrial biota), and 2.0E-5 mGy/d for freshwater fish (aquatic biota), both of which were far less than the generic dose criteria to protect biota from ionizing radiation. Also, the screening level assessment for ERICA's (Environmental Risks from Ionizing Contaminants: Assessments and management) limiting organisms showed that the risk quotient (RQ) for the estimated maximum soil and water activity was significantly less than unity for both the terrestrial and freshwater organisms. Conclusively, the radiological risk of the radioactivity released into the environment by the Fukushima nuclear accident to the public and the non-human biota in the republic of Korea is considered negligible.

Exposure Dose of Thyroid, Breast, and Sexual Gland using a Personal Dosimeter in Multiple CT Examinations (다중 CT 검사 시 개인선량계를 이용한 갑상선, 유방, 생식선의 피폭선량)

  • Kim, Hae-Suk;Kim, Jang-Oh;Lee, Yoon-Ji;Heo, Sung-Hoe;Lee, Chang-Ho;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.345-351
    • /
    • 2020
  • In this study, a dose assessment was conducted on the exposure dose of thyroid, breast and sexual gland using a personal dosimeter in multiple CT examinations currently being conducted in health examinations. The dose assessment was measured by attaching TLD and EPD to the locations of the thyroid, breast and sexual gland during CT examinations of Brain, Brain + C-S, Brain + Low lung, Brain + L-S among CT items. The generated dose of equipment, CTDIvol and DLP, was measured. The study found that effective doses were rated 41.7% higher for thyroid TLD in Brain + C-S CT examinations than for the general public, 156% higher for EPD, 10% for breast EPD in Brain + Low Lung CT examinations, 124.4% higher for reproductive TLD and 339.8% higher for Brain + L-S CT examinations. The CTDIvol and DLP analysis results showed that C-S CTDIvol values were higher than the diagnostic reference levels at 0.6%, Low Lung CTDIvol values at 5.7%, DLP values at 11.8% and L-S CTDIvol values at 1.2%. In order to reduce the exposure dose of patients, indiscriminate examination is reduced and dose limit setting is needed in health examination.

Development of a Monte Carlo Simulation Code (CALEFF) for Calibrating Thyroid Internal Dose Measurement and Detection Efficiency Calculation (갑상선 내부피폭선량 측정치 보정을 위한 몬테카를로 모의실험 코드 (CALEFF) 개발 및 검출효율 계산)

  • Ahn, Ki-Soo;Cho1, Hyo-Sung
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.117-122
    • /
    • 2005
  • According to the Para. 5 of Art 2 of the Korean Nuclear Safety Regulations, which was revised in 1999, internal dose assessment as well as external one should be performed by law for employees at a nuclear power plant from 2003, and their estimate errors should also be within 50%. Thus, more accurate internal dosimetry becomes important. Corresponding to such regulation revision, we are developing a more accurate thyroid-uptake internal dosimetric system and have developed a Monte Carlo simulation code, the so-called CALEFF, to calculate the detection efficiency of the dosimetric system. In this paper, we calculated detection efficiencies with various test conditions by using the CALEFF code and discussed their characteristics. We may use the detection efficiency calculated by the code in calibrating the thyroid internal dose from measured data.

  • PDF

The Evaluation of Patients' Radiation Dose During TACE of Interventional Radiology (TACE의 중재적 시술시 환자의 피폭선량 평가)

  • Lee, Seung-Youl;Lim, Hyun-Soo;Han, Man-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.209-214
    • /
    • 2011
  • Goal of this study was to measure effective radiation dose of highly exposed patients who were treated by TACE, interventional radiology from June to September 2010. The effective radiation dose was approximately measured by weighted DAP (dose area product) with the ionization chamber which is inserted in angiography equiment (Philips Allura Xper FD 20). Radiation dose was measured by TLD which was attached to patients' thyroid and genital gland. The average of ED (effective dose) was 18.43${\pm}$6.63 mSv per person and the average of radiation dose of thyroid and genital gland was 0.37 mSv, 0.77 mSv, respectively. The mean radiation dose of operators who wear the protector was 0.07 mSv for thyroid, and 0.01 mSv for genital gland, respectively. All staffs involved in TACE treatment, have to keep them aware and use the appropriate protectors to reduce the radiation dose of patient.