• 제목/요약/키워드: Thyroid Dose

검색결과 300건 처리시간 0.028초

방사선 요오드-131의 국소주입에 의한 양성 갑상선 결절의 치료 (Percutaneous Intranodular Injection Therapy of Radioactive Iodine-131 in Treatment of Benign Thyroid Nodules: A Preliminary Study)

  • 하일주;임동표;윤정한;제갈영종;범희승
    • 대한두경부종양학회지
    • /
    • 제17권2호
    • /
    • pp.174-178
    • /
    • 2001
  • Background and Objective: Percutaneous ethanol injection therapy has been used in the treatment of the benign thyroid diseases. Although the reported side-effects of the therapy was mild and transient, some side-effects including local or radiating pain are troublesome to the patients. Radioactive iodine-131($Ra-^{131}I$) also has been effectively and safely used for management of the benign thyroid diseases. So we developed the percutaneous intranodular injection therapy of $Ra-^{131}I$ as an alternative of percutaneous ethanol injection therapy. Materials and Methods: From December 1998 to October 1999, we treated 29 outpatients (25 women and 4 men, mean age: $47{\pm}12$ years). Inclusion criteria were follows; age >30 years, cytologically benign, with normal thyroid function, cold nodule on thyroid scintigram, solid or mixed natured nodules in sonographical evaluation. Nodular volume was estimated by sonography according to the ellipsoid formula. $Ra-^{131}I$(0.1mCi/ml) was administered in a single dose injection. Follow-up studies every 3 months consisted of full history, thyroid function test, and sonography. We determined the therapeutic response is effective if the volume reduction of the nodule occurred above 30%. Results: After at least 3 months follow-up, 11 patients showed effective response, 12 patients showed minimal or unchanged response and 6 patients showed progression. Although side-effects such as injection pain, febrile reaction, and hormonal changes were absent, an infectious complication in injection site was developed from 1 case. Conclusion: Although we need a more prolonged follow-up to evaluate the delayed sequelae, we can suggest that percutaneous intranodular injection therapy of $Ra-^{131}I$ may be an attractive non-surgical treatment in selected cases of benign thyroid nodules.

  • PDF

Differentiated Thyroid Carcinoma Risk Factors in French Polynesia

  • Xhaard, Constance;Ren, Yan;Clero, Enora;Maillard, Stephane;Brindel, Pauline;Rachedi, Frederique;Boissin, Jean-Louis;Sebbag, Joseph;Shan, Larrys;Bost-Bezeaud, Frederique;Petitdidier, Patrick;Drozdovitch, Vladimir;Doyon, Francoise;Rubino, Carole;de Vathaire, Florent
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권6호
    • /
    • pp.2675-2680
    • /
    • 2014
  • Background: To investigate differentiated thyroid cancer risk factors in natives of French Polynesia is of interest because of the very high incidence of this cancer in the archipelago. Materials and Methods: To assess the role of various potential risk factors of thyroid cancer in the natives of French Polynesia we performed a case-control study. The study included almost all the French Polynesians diagnosed with differentiated thyroid carcinoma between 1981 and 2003 (n=229) and 373 French Polynesian control individuals from the general population without cancer. Results: Thyroid radiation dose received from nuclear fallout before the age of 15, a personal history of neck or/and head medical irradiation, obesity, tallness, large number of children, an artificial menopause, a familial history of thyroid cancer, a low dietary iodine intake, and having a spring as the main source of drinking water were found to be significant risk factors. No roles of smoking habits, alcohol consumption, iodine containing drugs, and exposure to pesticides were evidenced. Conclusions: Except for smoking, differentiated thyroid carcinoma risk factors in natives of French Polynesia are similar to those in other populations. Our finding on the role of having a spring as a drinking water origin is coherent with some other studies and could be due to geological factors.

분화성 갑상선암환자의 방사성 요오드 치료시 전리함과 Geiger-Muller계수관에서 방사선량률 측정값 비교 (Comparison of the Measured Radiation Dose-rate by the Ionization Chamber and GM(Geiger-Müller) Counter After Radioactive Iodine Therapy in Differentiated Thyroid Cancer Patients)

  • 박광훈;김구환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.565-570
    • /
    • 2016
  • 방사성 요오드($^{131}I$) 치료는 분화성 갑상선암 환자에서 재발을 감소시키고 생존률을 증가시키나, 환자에서 방출되는 방사능으로 인하여 피폭을 야기시킬 수 있으므로 환자로부터 발생되는 방사선량률을 측정하는 것이 방사선안전관리 측면에서 중요하다. 방사성 요오드($^{131}I$) 치료시 널리 사용되는 측정기 중 전리함과 GM계수관으로 측정된 방사선량률의 감도와 측정효율을 구하였다. 방사성 요오드($^{131}I$)를 150mCi 경구투여 받은 분화성 갑상선암 환자의 상복부로부터 1 m거리에서 경과 시간에 따라 방사선량률을 측정하였다. 시간에 따른 변화를 직접적으로 비교한 결과, 고선량률에서의 감도와 측정효율은 GM계수관보다 전리함이 높게 나타났고, 통계적으로 유의하였다(p<0.05). 저선량률에서의 감도와 측정효율은 GM계수관보다 전리함이 낮게 나타났지만 통계적으로 유의한 차이를 나타내지 않았다(p>0.05). 방사성 요오드($^{131}I$) 치료시에 검 교정이 완료된 전리함과 GM계수관으로 정확하고 신속한 방사선량률을 측정하여 환자에게 설명함으로써 방사성 요오드 치료 후 퇴원하는 환자에게 환자가족 또는 주변 사람들에게 미칠 수 있는 방사선피폭을 예측하고, 불필요한 예단을 줄여줄 수 있을 것이다.

뇌혈관 중재적시술에 있어 측방향 차폐체를 이용한 시술자 피폭 선량 저감화 방법 연구 (Reducing Radiation Exposure Dose on Operator by Using Lateral Protection in Neuro-Intervention)

  • 김종덕;안병주;이준행
    • 한국방사선학회논문지
    • /
    • 제8권1호
    • /
    • pp.1-10
    • /
    • 2014
  • 양방향 뇌혈관촬영기는 하나의 선원에서 방사선이 나오는 것이 아니라 정방향과 측방향에서 방사선 피폭이 이루어지기 때문에 방사선 관계종사자의 피폭이 더욱 많아질 수밖에 없다. 따라서 환자가 받는 선량도 중요하겠지만 시술을 시행하고 있는 방사선 관계종사자 역시 피폭선량을 줄일 수 있는 방법에 대해 많은 관심을 보이고 있다. 본 연구의 목적은 양방향 뇌혈관촬영기의 혈관검사 및 중재적방사선시술에 있어 X-선 관구에서 직접 조사되는 1차 방사선, 정방향관구와 측방향 검출기사이에서 발생하는 1차 산란방사선, 상대적으로 적지만 촬영실 벽이나 바닥에서 반사되는 2차 산란방사선 발생을 간과하지 않을 수 없기에 기존의 일반적인 차폐방법인 천정형 차폐, 테이블형 차폐방법에서 보다 더 적극적인 차폐방법인 측방향 차폐체의 방어용구를 설치하여 시술자가 받는 직접방사선 및 산란방사선에 의한 피폭선량을 최대한 줄이고자 노력하였다. 그 결과 투시측정에서는 생식샘 약 3.64배, 갑상샘 약 3.13배, 눈 약 4.42배 정도 더 감소하였고, 디지털 감산 혈관조영측정에서는 생식샘 약 4.98배, 갑상샘 약 3.00배, 눈 약1.67배의 피폭선량 감소효과를 얻어내었다. 결론적으로 양방향 뇌혈관촬영기의 혈관검사 및 중재적방사선시술시 설치하였던 측방향 차폐체의 방어용구는 일반적인 차폐방법보다 시술자의 피폭선량을 감소시키는데 많은 효과를 주었다고 사료된다.

Simulation and assessment of 99mTc absorbed dose into internal organs from cardiac perfusion scan

  • Saghar Salari;Abdollah Khorshidi;Jamshid Soltani-Nabipour
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.248-253
    • /
    • 2023
  • Directly, it is not possible to measure the absorbed dose of radiopharmaceuticals in the organs of the human body. Therefore, simulation methods are utilized to estimate the dose in distinct organs. In this study, individual organs were separately considered as the source organ or target organ to calculate the mean absorption dose, which SAF and S factors were then calculated according to the target uptake via MIRD method. Here, 99mTc activity distribution within the target was analyzed using the definition and simulation of ideal organs by summing the fraction of cumulative activities of the heart as source organ. Thus, GATE code was utilized to simulate the Zubal humanoid phantom. To validate the outcomes in comparison to the similar results reported, the accumulation of activity in the main organs of the body was calculated at the moment of injection and cardiac rest condition after 60 min of injection. The results showed the highest dose absorbed into pancreas was about 21%, then gallbladder 18%, kidney 16%, spleen 15%, heart 8%, liver 8%, thyroid 7%, lungs 5% and brain 2%, respectively, after 1 h of injection. This distinct simulation model may also be used for different periods after injection and modifying the prescribed dose.

수술 후 갑상선기능저하가 동반된 고도비만환자의 펜터민염산염/토피라메이트의 저용량 오프라벨 사용 (Low-Dose Off-Label Use of Phentermine/Topiramate in the Individual with Morbid Obesity and Postoperative Hypothyroidism)

  • 박정하
    • 비만대사연구학술지
    • /
    • 제1권1호
    • /
    • pp.43-45
    • /
    • 2022
  • Intensive lifestyle modifications and anti-obesity medications are essential for obesity treatment. Antiobesity medications should be selected according to the patient's comorbidities, symptoms, and preferences. This case report describes the treatment of a morbidly obese patient with a history of depression, who complained of tingling and numbness after total thyroidectomy for papillary thyroid cancer. Very low-dose controlled-release phentermine/topiramate was prescribed and intensive lifestyle modifications were encouraged. As a result, the patient effectively lost weight and reached a near-normal weight without adverse drug effects. This implies that even an off-label anti-obesity medication low dose may be better for some patients, and the most important factor in obesity treatment is patient-tailored treatment.

랫드에서 TSH와 갑상선 호르몬에 미치는 dopamine계의 영향 (Effects of the dopaminergic system on release of TSH and thyroid hormone in rats)

  • 이상우;김진상;한정희
    • 대한수의학회지
    • /
    • 제32권2호
    • /
    • pp.165-173
    • /
    • 1992
  • The present study was carried out to investigate the effects of dopaminergic drugs and the role of specific dopamine(DA) receptors on the release of TSH, $T_4$ and $T_3$. Serum TSH levels (cold-induced, $4{^{\circ}C}$) were determined using RIA(radioimmunoassay) at 30 min after administration of dopamine agonists and antagonists. Serum $T_4$ and $T_3$ levels were detected after these dopaminergic drugs were administered subcutaneously twice a day for a week. The results of the study are summarized as follows : Apomorphine, a nonspecific DA receptor agonist, produced a dose-depedent decrease in serum TSH, $T_4$ and $T_3$ levels. However, only low doses (0.3, 1.0mg/kg) of SKF38393, a specific $D_1$-receptor agonist, produced a decrease in serum lelvels of TSH. I,Y171555, a specific $D_2$-receptor agonist, produced a dose dependent decrease in serum TSH, $T_4$ and $T_3$ levels. However, SCH23390, a specific $D_1$-receptor antagonist, produced a decrease except in serum T levels which were increased dose dependently. High doses (1.0, 3.0mg/kg) of sulpiride, a specific $D_2$-receptor antagonist, made a increase in the serum levels of TSH and $T_3$. The effects of dopaminergic drugs in serum TSH and $T_4$ levels was potentiated by the pretreatment of apomorphine. The overall results of this study suggest that the regulation of TSH, $T_4$ and $T_3$ secretion were mediated via specific $D_1$ and $D_2$ receptor.

  • PDF

益氣補血湯 물 추출물이 PTU로 유발된 Rat의 갑상선기능저하증에 미치는 영향 (Effects of Yikgeebohyul-tang Aqueous Extracts on the Rat Hypothyroidism Induced by Propylthiouracil)

  • 손지혜;김동철
    • 대한한방부인과학회지
    • /
    • 제28권3호
    • /
    • pp.54-73
    • /
    • 2015
  • Objectives The object of this study was to evaluate the effect of Yikgeebohyul-tang aqueous extracts (YKBHT) on the propylthiouracil (PTU)-induced rat hypothyroidism. Methods The rats were divided into 6 groups : intact vehicle control, PTU control, LT4, YKBHT 500, 250 and 125 mg/kg treated groups. Hypothyroidism was induced by daily subcutaneous treatment of PTU 10 mg/kg for 28 days. YKBHT aqueous extracts were administered once a day as an oral dose of 500, 250 and 125 mg/kg for 42 days. The changes were observed : weight of body, thyroid gland, liver, testis, epididymis and prostate, serum thyroid hormone levels, serum male sex hormone levels, serum lipid profiles, liver and testis antioxidant system. These results were compared with LT4 0.5 mg/kg intraperitoneally treated rats. Results These PTU induced hypothyroidism and related hepatic and male reproductive organ damages were favorably and dose-dependently inhibited by treatment of YKBHT 500, 250 and 125 mg/kg, and YKBHT also effectively regulated the PTU-induced abnormal antioxidant defense factor changes in the both liver and testis. Although, LT4 also inhibited PTU-induced hypothyroidism and relative liver damages. But it deteriorated the hypothyroidism related testis, epididymis and prostate damages through testicular oxidative damages. Conclusions : The result of this study suggests that YKBHT has favorable effects on the hypothyroidism and related liver and reproductive organ damages with augmentation of antioxidant defense factor in the testis and liver. YKBHT 500, 250 and 125 mg/kg dose-dependently inhibited PTU-induced hypothyroidism and related liver and male reproductive organ damages in rats.

Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector

  • Lee, Kyeong Hee;Kim, Myeong Seong;Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1377-1384
    • /
    • 2018
  • Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.

소아 구내촬영 시 방사선량 평가 및 최적화 방안에 대한 연구 (A Study of Radiation Dose Evaluation and Optimization Methods for Intra Oral Dental X-ray in Pediatric Patient)

  • 이현용;조용인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.195-203
    • /
    • 2021
  • Although intra oral dental x-ray is a lower dose than other radiological examinations, pediatric patients are known to have a higher risk of radiation damage than adults. For this reason, pediatric dental x-ray requires management of dose evaluation and imaging conditions during the examination. In this study, the dose calculation program ALARA-Dental(child/adult) was used to evaluate the organ dose and effective dose exposed to each examination site during intra oral imaging of children during dental radiographic examination, and dose analysis according to the imaging conditions was performed. As a result, the highest organ dose distribution was shown at 0.044 ~ 0.097 mGy in all are as of the mucous membrane of oral cavity except for the maxillary incisors and canines. Also, in the case of the thyroid gland, the maxillary canine and maxillary premolar examination showed 0.027 and 0.020 mGy, respectively, and the dose distribution was 15.4% to 70.0% higher than that of the mandibular examination. As for the effective dose calculated during intra oral imaging, the maxillary anterior and canine examinations showed the highest effective doses of 0.005 and 0.004 mSv, respectively, and the maxillary area examination showed a higher dose distribution on average than the mandible.