• 제목/요약/키워드: Three-phase ac/dc/ac PWM converter

검색결과 81건 처리시간 0.025초

고속전철용 보조전원장치 시스템 조합시험 (Combined test of Power Supply System for Korean High Speed Train)

  • 조현욱;김연충;김태환;장경현;김철호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.619-625
    • /
    • 2008
  • Electrical Power supply System conditions of korea high speed train consists of main transformer, four AC-DC PWM converter of Auxiliary Block, Battery Charger in Power Car and Trailer Car, Trailer Inverter, Auxiliary inverter. Main transformer, at nominal voltage of 25kv supplied to secondary winding nominal output Voltage 383Vac, The Auxiliary block consists of AC-DC converters for generating 670VDC power, Auxiliary inverters for ventilation and air compressor, Trailer car inverter provide three phase power supplies at 440Vac for air conditioning and heating. The Battery charger Trailer and Power car supplies 72VDC all necessary equipment to energize the trainset equipment and suppy essential control. This Paper introduces the combined test results of the power supply system for korea high speed train. The main purpose of this combined test is to verify the performance of the power supply system that is designed to operate up to full load test.

  • PDF

DSP 소프트웨어에 의한 전력변환기 게이팅 신호 발생 (Power Converter Gating Signal Generation with DSP Software)

  • 이해춘;박태열;김기택
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.111-116
    • /
    • 2001
  • Power converters are widely used in the applications of servo drives of ac and dc motors and power supplies. For the control of the converters carious control algorithms have been proposed and realized by gating signal generation. Software control shemes are being applied to implement the control algorithms, but analog circuits are still used for the gating signal generation because it requires very fast and precise timing. In this paper the gating signal generation with DSP software are proposed for the three phase to three phase PWM converter. Design procedures and software flowcharts are presented and some experimental waveforms are also presented to verify the proposed algorithms.

  • PDF

Random PWM 기법을 이용한 전도노이즈 저감 (A study on the Conducted Noise Reduction in Random PWM)

  • 정동효
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.154-158
    • /
    • 2006
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. These features are brought by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI(Electromagnetic Interference) which deteriorate the reliability of the converter themselves and entire electronic systems. This problem on the surge and noise is one of the most serious difficulties in AC-to-DC converter. Random Pulse Width Modulation (RPWM) is peformed by adding a random perturbation to switching instant while output-voltage regulation of converter is performed. RPWM method for reducing conducted EMI in single switch three phase discontinuous conduction mode boost converter is presented. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. A RPWM control method was proposed in order to smooth the switching noise spectrum and reduce it's level. Experimental results are verified by converter operating at 300v/1kW with $5%{\sim}30%$ white noise input. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

  • PDF

DSP칩을 이용한 스위칭 전력변환 시스템의 특성 개선 기법 (The Improvement Techniques of Characteristics using DSP Chip in Switching Power Converter System)

  • 강민수;김상욱;임동기;강호현;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.670-672
    • /
    • 2004
  • In this paper, single phase boost converter with low current harmonic components and high power factor are proposed. A single-phase half-bridge rectifier based on a neutral point switch clamped scheme is proposed to draw a nearly unity power factor and regulate the DC link voltage. Three power switches are employed in the proposed rectifier. This rectifier is controlled to generate a bipolar or unipolar PWM voltage waveform on the AC side. The proposed converter is implemented by a digital signal processor.

  • PDF

3상 6펄스 PWM 정류기의 D-Q 제어 기반 출력전압 제어 알고리즘 및 EMTP-RV 시뮬레이션 연구 (A Study on the D-Q Control based Output Voltage Control Algorithm and EMTP-RV Simulation of Three-phase 6-Pulse PWM Rectifier)

  • 고윤석
    • 한국전자통신학회논문지
    • /
    • 제16권1호
    • /
    • pp.45-52
    • /
    • 2021
  • 3상 PWM 정류기에 대한 공간벡터제어 기반 전압제어방식은 스위칭 구간에 대한 스위칭 패턴을 설계해야하기 때문에 최적한 스위칭 패턴을 설계하는데 많은 노력이 요구된다. 본 연구에서는 3상 6펄스 전압형 PWM 정류기를 위한 D-Q 제어에 기반 한 SPWM 출력전압 제어 알고리즘을 연구하였다. 출력전압제어 알고리즘에서 3상 기준신호들은 공간벡터 표시법에 기반 한 D-Q 변환으로부터 얻어지며 스위칭 패턴 대신에 SPWM 방식을 이용하여 정류기 스위칭 제어 신호들을 생성하도록 하였다. 다음으로, EMTP-RV를 이용하여 D-Q 제어기반 SPWM 방식을 가지는 3상 6펄스 전압형 PWM 정류기를 모델링하였다. 끝으로, EMTP-RV 시뮬레이션을 통해 얻어지는 출력전압파형을 기준 값과 비교, 출력전압이 기준전압을 정확하게 추종함을 확인함으로서 D-Q 제어기반 SPWM 전압제어 알고리즘의 유효성을 확인할 수 있었다.

Modulation, Harmonic Analysis, and Balancing Control for a New Modular Multilevel Converter

  • Li, Binbin;Zhang, Yi;Wang, Gaolin;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.163-172
    • /
    • 2016
  • The modular multilevel converter (MMC) has been receiving increased attentions in recent years. The new modular multilevel converter is a derivative topology from the traditional MMC in which the number of sub-modules (SMs) necessitated by each phase can be reduced by one. This paper presents a phase-shifted carrier pulse-width modulation (PSC-PWM) for the new MMC with an optimal phase-shifted angle to suppress the harmonics of the output voltage. Further, the harmonic features when the capacitor voltage of the middle SM is selected as two different values are also investigated. Moreover, in order to avoid introducing an unnecessary dc offset current at the ac terminals of the new MMC, a novel capacitor voltage balancing scheme is proposed by adjusting the amplitude of the reference signals rather than the offset. Finally, the validity and effectiveness of the proposed modulation and balancing schemes have been verified by experimental results based on a three-phase prototype of the new MMC.

DC전철구간의 에너지회생장치 개발 방향 (Direction for Development of Energy Regeneration Device for DC Electric Railway System)

  • 김용기;배창한;한문섭;양영철;장수진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.804-808
    • /
    • 2007
  • when electric traction system used DC 1500V runs on decline of rail road track and slows down, Dc voltage goes beyond regular voltage. In this case extra power is forcibly wasted by resister because rectifier of substation and electric train including power converter and so on are out of order. This paper described a DC electric railway system, which can generate the excessive DC power form DC bus line to AC source in substation for traction system. The proposed regeneration inverter system for DC traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In addition, electric traction system products harmonic current and voltage distortion and reactive power because power converter is used so regeneration inverter normally runs such as active power filter(APF) for improving power quality. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three phase PWM inverters and composed of parallel inverters, output transformers, and an LCL filter.

  • PDF

Random PWM 기법을 이용한 3상 승압형 컨버터 전도노이즈 저감에 관한 연구 (A study on the Conducted Noise Reduction in Three-Phase Boost Converter using Random Pulse Width Modulation)

  • 정동효
    • 전기학회논문지P
    • /
    • 제51권3호
    • /
    • pp.120-125
    • /
    • 2002
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. These features are brought by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI(Electromagnetic Interference) which deteriorate the reliability of the converter themselves and entire electronic systems. This problem on the surge and noise is one of the most serious difficulties in AC-to-DC converter. In the switching-mode power converter, the output voltage is generally controlled by varying the duty ratio of main switch. When a converter operates in steady state, duty ratio of the converter is kept constant. So the power of switching noise is concentrated in specific frequencies. Generally, to reduce the EMI and improve the immunity of converter system, the switching frequency of converter needs to be properly modulated during a rectified line period instead of being kept constant. Random Pulse Width Modulation (RPWM) is performed by adding a random perturbation to switching instant while output-voltage regulation of converter is performed. RPWM method for reducing conducted EMI in single switch three phase discontinuous conduction mode boost converter is presented. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. A RPWM control method was proposed in order to smooth the switching noise spectrum and reduce it's level. Experimental results are verified by converter operating at 300V/1kW with 5%~30% white noise input. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

Design Considerations for Auto-Connected Multi-Pulse Rectiviers for High Power AC Motor Drives

  • 이방섭
    • 전력전자학회논문지
    • /
    • 제4권5호
    • /
    • pp.413-422
    • /
    • 1999
  • Auto-connected multipulse(12/24pulse) rectifier schemes are cost effective methods for reducing line current hamonics in PWM drive systems. Employing these schemes to enhance utility power quality requires careful attention to several design considerations In particular, excursion of dc-link voltage at no load, effect of pre-existing voltage distortion, impedance mismatches, unequal diode drops on rectifier current sharing and performance, are fully analyzed, Several corrective measures to improve the performance of 12/24­pulse rectifier systems are also discussed. Finally, experimental results on a 460V, 60Hz 400kVA commercial ASD, retrofitted with 12/24pulse rectifier systems are discussed in detail.

  • PDF

IP 제어기를 이용한 통신 전원용 3상 PWM 컨버터의 전압 제어 (IP Voltage Controller of Three-phase PWM Converter for Power Supply of Communication System)

  • 신희근;김학원;조관열;지준근
    • 한국산학기술학회논문지
    • /
    • 제12권6호
    • /
    • pp.2722-2728
    • /
    • 2011
  • 대용량 전원장치의 정류기는 입력전류의 고조파를 줄이기 위해, 입력 전류 제어기능을 갖는 3상 PWM 정류기의 적용이 확대되고 있다. 3상 PWM 정류기의 전압제어기는 일반적으로 PI 제어기가 사용되며, 출력 전압의 안정성을 얻고 신뢰성을 확보하기 위하여 전압 제어기는 출력전압의 과도상태에서 오버슈트(Overshoot)를 작게 설계한다. 그러나 부하 변동이 급격한 대용량 통신용 전원 장치에 3상 PWM 정류기가 적용될 경우 빠른 부하 변동에 대한 안정적 전압 응답을 얻기 위하여 보다 넓은 대역폭을 갖도록 전압 제어기를 설계할 필요가 있다. 넓은 대역폭을 갖는 PI 제어기는 과도한 출력전압의 오버슈트가 발생될 수 있으며, 이 과도한 출력전압 오버슈트는 통신용 전원의 안정성을 해칠 수 있다. 본 논문에서는 과도 상태에서 출력전압의 오버슈트를 작게 하기 위하여 IP 제어기를 갖는 3상 PWM 정류기의 전압 제어기를 제안한다. 제안된 전압 제어기는 3상 PWM 정류기의 기동 시와 부하 변동시의 과도 응답특성을 개선될 수 있음을 시뮬레이션 및 실험을 통해 확인하였다.