• 제목/요약/키워드: Three-dimensional evaluation

검색결과 1,043건 처리시간 0.025초

Evaluation of Fabric Pilling Using Hybrid Imaging Methods

  • Kim Sung-Min;Park Chang-Kyu
    • Fibers and Polymers
    • /
    • 제7권1호
    • /
    • pp.57-61
    • /
    • 2006
  • A study has been made on the quantification and evaluation of fabric pilling using two-dimensional and three-dimensional hybrid imaging methods. Two-dimensional imaging method was good for some samples while three-dimensional measurement method for others, according to the properties of their base fabric. Various image processing techniques as well as three-dimensional data processing algorithms were applied for the extraction of pills from measured data and a series of shape parameters have been defined for the objective evaluation of fabric pilling. An evaluation criterion that is compatible with the conventional evaluation method has been proposed by applying the new evaluation method to the current photographic standards.

악교정 수술에서 모의 조종된 3차원 전산화 단층촬영상의 응용 (Application of Simulated Three Dimensional CT Image in Orthognathic Surgery)

  • 김형돈;유선국;이경상;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.363-385
    • /
    • 1998
  • In orthodontics and orthognathic surgery. cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery. too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipments and because of its expenses and amount of exposure to radiation. limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram. pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. and for validation of new method. in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery. computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of dry skull that position of mandible was displaced. range of displacement between computer-simulated three dimensional images and actual postoperative three dimensional images in co-ordinates values was from -1.8 mm to 1.8 mm and 94% in displacement of all co-ordinates values was from -1.0 mm to 1.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). 2. In four cases of orthognathic surgery patients, range of displacement between computer­simulated three dimensional images and actual postoperative three dimensional images in coordinates values was from -6.7 mm to 7.7 mm and 90% in displacement of all co-ordinates values was from -4.0 to 4.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). Conclusively. computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. Therefore. potentiality that can construct postoperative three dimensional image without three dimensional computed tomography after surgery was presented.

  • PDF

전산화단층상을 이용한 측두하악관절의 삼차원 재구성상의 비교연구 (A COMPARATIVE STUDY OF THREE-DIMENSIONAL RECONSTRUCTIVE IMAGES OF TEMPOROMANDIBULAR JOINT USING COMPUTED TOMOGRAM)

  • 임숙영;고광준
    • 치과방사선
    • /
    • 제23권2호
    • /
    • pp.335-344
    • /
    • 1993
  • The purpose of this study was to clarify the spatial relationship of temporomandibular joint and to an aid in the diagnosis of temporomandibular disorder. For this study, three-dimensional images of normal temporomandibular joints were reconstructed by computer image analysis system and three-dimensional reconstructive program integrated in computed tomography. The obtained results were as follows: 1. Two-dimensional computed tomograms had the better resolution than three dimensional computed tomograms in the evaluation of bone structure and the disk of TMJ. 2. Direct sagittal computed tomograms and coronal computed tomograms had the better resolution in the evaluation of the disk of TMJ. 3. The positional relationship of the disk could be visualized, but the configuration of the disk could not be clearly visualized on three-dimensional reconstructive CT images. 4. Three-dimensional reconstructive CT images had the smoother margin than three-dimensional images reconstructed by computer image analysis system, but the images of the latter had the better perspective. 5. Three-dimensional reconstructive images had the better spatial relationship of the TMJ articulation, and the joint spaces were more clearly visualized on dissection images.

  • PDF

입체 형상 분석을 위한 3차원 계측시스템의 활용 -WBS와 RapidForm 2004를 중심으로- (Applications of Three-Dimensional Measurement System for Shape Analysis -Focused on WBS and RapidForm 2004-)

  • 이명희;정희경
    • 복식
    • /
    • 제55권5호
    • /
    • pp.55-64
    • /
    • 2005
  • The concern with three-dimensional measurement has been growing in recent years. And over the last few years, several studies have been made on three-dimensional measurement. Some of the studies using a three-dimensional measurement have focused on type of form of human body and evaluation of fitness. But there has been no study about applications of three-dimensional measurement system for shape analysis. So, the purpose of this study was to investigate about application of three-dimensional mea-surement system lot shape analysis. The instrument and tools for three-dimensional measurement was Whole Body 3D scanner(model name: Exyma-WBS2H). Analysis program used in experiment is Rapid Form 2004 PPI (INUS technology, Int, Korea). The following results were obtained; 1. The point data using three-dimensional measurement system built 3D model. 2. The three-dimensional data were used to analyze length and curvature of shape. 3. The shape using three-dimensional measurement system could be used in variety field.

초고속 이송 방식 3차원 Bending Machine 개발에 관한 연구 (A Study on the Development of a High Speed Feeding Type Three-Dimensional Bending Machine)

  • 임상헌;이춘만
    • 한국정밀공학회지
    • /
    • 제22권11호
    • /
    • pp.91-98
    • /
    • 2005
  • This study has been focused on the development of a high speed feeding type three-dimensional bending machine. It is designed for manufacture of copper pipe for heat exchangers. For the purpose of design of the machine, analysis of bending process, structural analysis and reliability evaluation of the machine by a laser interferometer are carried out. The analysis is carried out by FEM simulation using commercial softwares, DEFORM, MARC and CATIA V5. In addition, the machine has attained high accuracy and repeatability. In order to improve the accuracy of this machine, the maximum speed, positioning accuracy and repeatability of feed are measured by the laser interferometer. The final results of analysis are applied to the design of a high speed feeding type three-dimensional bending machine and the machine is successfully developed.

3차원 Bending Machine 설계 및 개발에 관한 연구 (A Study on the Design and Development of Three Dimensional Bending Machine)

  • 이춘만;임상헌;김현진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1448-1451
    • /
    • 2004
  • This study is concerned about the design and development of three dimensional bending machine. The purpose of this study is design and development of three-dimensional bending machine by analysis of bending process and structural analysis simulation. The analysis is carried out by FEM simulation using DEFORM and CATIA V5 software. Based on this study, the three dimensional bending machine was developed. In order to evaluate a performance and reliability of the developed three dimensional bending machine, we used laser interferometer and three axial measuring system.

  • PDF

3차원 이온 주입 시뮬레이터 개발에 관한 연구 (A Study of Three Dimensional Ion Implantation Simulator)

  • 송재복;원태영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.93-96
    • /
    • 1996
  • We developed three dimensional Monte carlo ion implantation simulator which simulate distributions of impurities under the ion implantation on the tilted multi-layered layer. Our simulation reveals three dimensional shadow effect and sidewall scattering effect due to the geometrical shapes. For the evaluation of the developed three dimensional Monte carlo ion implantation simulator, calculations with 100,000 ions have been performed for the island and hole structures with a thin oxide of 100$\AA$ and nitride of 2000$\AA$. The simulation results showed that the distribution of ion decreases near the conner of the hole structure covered with a nitride layer and increases near the conner for the island structure open to oxide. Moreover, three dimensional distributions of ions were obtained with varying incident energy, tilt and rotation angle, mask depth and three-dimensional structure geometry.

  • PDF

컴퓨터단층촬영에서 3차원 재구성 영상을 통한 개의 골절 진단 (Three Dimensional Computed Tomography in the Assessment of Subtle Fracture in Dogs)

  • 이기창;권정국;송경진;최민철
    • 한국임상수의학회지
    • /
    • 제20권4호
    • /
    • pp.523-526
    • /
    • 2003
  • Three dimensional computed tomographic images were obtained in two cases with trauma. The first case of a 3 year-old male Maltese, with ataxia and head tilting due to head trauma was referred to veterinary medical teaching hospital, Seoul National University. Remarkable findings were not found on survey radiographs. With the help of three-dimensional reconstruction computed tomographic imaging, parietal and occipital bone fracture was identified. The second case of 4 month-old female Yorkshire terrier with left forelimb lameness was referred right after trauma. Survey radiography showed obvious incongruity of the elbow joint. Lateral and medial condyle of the left humerus fracture and lateral displacement of the left ulna were apparent in three-dimensional computed tomographic image. It was considered that three-dimensional computed tomography could be used as an aid modality for the exact evaluation of extends and degree of fracture as well as planning of orthopedic surgery.

도로설계 평가를 위한 3차원 시뮬레이션 적용 (Application of Simulation for Road Design Evaluation)

  • 김가야;정범석;김남석
    • 한국지리정보학회지
    • /
    • 제11권2호
    • /
    • pp.121-131
    • /
    • 2008
  • 2차원적인 도로설계는 설계기준과 운전자의 반응 사이에는 상이한 점이 많아 위험성을 내포하고 있다. 따라서 2차원 도로설계는 시공전에 예측을 하기가 어려운 실정이다. 그러나, 3차원 도로설계는 요구되는 구성요소의 완성 이후 발생하는 문제를 예측할 수 있다. 본 연구에서는, 실제도로에서 도로설계평가를 위하여 설계를 하였다. 그리고 도로설계는 Inroad를 라는 도로설계프로그램을 사용하였다. 또한, 수치지형도와 포고자료를 이용하여 DTM을 생성하였다. 3차원 도로설계는 도로의 DTM 과 지형자료를 합성하여 설계를 하였다. 3차원적으로 도로설계된 것을 이용하여 설계평가를 수행하였다. 도로선형의 안정성 평가를 위하여 운전자 시뮬레이션과 시거분석을 실시하였다. 그리고, 음영시뮬레이션을 통해 도로노면결빙구간의 불량구간을 추출하였다. 시뮬레이션 결과, 본 연구에서는 도로완공후의 모습을 확인할 수 있었다. 그리고 시거를 시각적으로 산정을 할 수 있었다. 또한 음영 시물레이션을 의해 도로노면결빙구간을 추출하였다.

  • PDF

안면골 외상환자의 전산화단층상을 이용한 삼차원재구성상의 비교연구 (A COMPARATIVE STUDY OF THREE DIMENSIONAL RECONSTRUCTIVE IMAGES USING COMPUTED TOMOGRAMS OF FACIAL BONE INJURIES)

  • 최은숙;고광준
    • 치과방사선
    • /
    • 제24권2호
    • /
    • pp.413-423
    • /
    • 1994
  • The purpose of this study was to clarify the spatial relationship in presurgical examination and to aid surgical planning and postoperative evaluation of patients with facial bone injury. For this study, three-dimensional images of facial bone fracture were reconstructed by computed image analysis system and three-dimensional reconstructive program integrated in computed tomography. The obtained results were as follows: 1. Serial conventional computed tomograms were value in accurately depicting the facial bone injuries and three-dimensional reconstructive images demonstrated an overall look. 2. The degree of deterioration of spatial resolution was proportional to the thickness of the slice. 3. Facial bone fractures were the most distinctly demonstrated on inferoanterior views of three-dimensional reconstructive images. 4. Although three-dimensional reconstructive images made diagnosis of fracture lines, it was difficult to identify maxillary fractures. 5. The diagnosis of zygomatic fractures could be made equally well with computed image analysis system and three-dimensional reconstructive program integrated in computed tomography. 6. The diagnosis of mandibular fractures could be made equally well with computed image analysis system and three-dimensional reconstructive program integrated in computed tomography.

  • PDF