• Title/Summary/Keyword: Three-dimensional body scanner

Search Result 34, Processing Time 0.024 seconds

Development of Three Dimensional Scanner for Anthropometric Measurement (인체측정용 3차원 스캐너 제작)

  • Kim, Min-Hyo;Nam, Yun-Ja
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.77-88
    • /
    • 2001
  • A three dimensional body scanner for anthropomentric measurement has been developed. In this study, the slit laser beam projection method followed by digital image processing was used to provide accurate spatial data with the typical optical triangulation method to overcome the many difficulties in traditional in accurate and time-consuming tactic measurement method using rulers and gauges. Compared with other commercialized scanners. this system can obtain a relatively wide range of data at a much lower cost by the specially designed scanning process such as the simultaneous acquisition of vertical and horizontal body cross-section profiles.

  • PDF

The Classification of Elderly Men's Feet - With the Three-dimensional Body Scanner Data of Size Korea - (노년 남성의 발 유형 분류 -Size Korea의 3차원 측정 데이터를 이용하여-)

  • Seok, Hye-Jung;Park, Ji-Eun
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.10
    • /
    • pp.50-59
    • /
    • 2007
  • This study has been conducted to classify elderly men's feet with the three-dimensional body scanner data of Size Korea. It was intended to assist the manufacturing of the shoes that can appropriately perform the functions of feet, by providing the specific information about the shapes of elderly men's feet that are altered as a result of aging and shoe-wearing for a long time. The findings are as follows. 1. The investigations into the average and standard deviation of the measurements and index values for the elderly men's feet showed a large personal difference in the items of length and circumference. 2. The factors constituting the elderly men's feet were observed to be the size of foot width(Factor 1), the central angle of feet and the extension of toes(Factor 2), the size of ankle(Factor 3), the positions of lateral malleolus and pternion(Factor 4), and the position and size of medial malleolus(Factor 5). 3. The cluster analysis for the classification of elderly men's feet produced three types of them.

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.

Three‐Dimensional Automatic Measurement Extraction Algorithms for Neck‐base Part of Females in Their Twenties (20대 여성의 목밑둘레 부위에 대한 3차원 자동 측정 알고리즘)

  • Hwang, Keun-Young;Nam, Yun-Ja;Park, Jae-Kyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.35-43
    • /
    • 2005
  • The purpose of this study is to suggest computer assisted neck-base's landmark identification algorithms and measurement extraction methods from three-dimensional human scan data. So we developed the algorithms for automatic identification of landmarks related to the neck-base types. The subjects were 58 women $18{\sim}24$ years of age. Their body were measured directly and indirectly by using camera and three-dimensional body scanner. They were measured during the months of October in 2001. Based on the characters of classified neck-base types, algorithms for the automatic identification of landmarks and methods of automatic measurement are developed. The three-dimensional automatic measuring program is made by $C^{++}$ language. Using this program, 4 landmarks are identified and 6 items are measured. In the verifying the precision of automatic measurement, the height measurements(cervicale, side neck point, front neck point) were relatively accurate, but neck-base width measurement was measured wide.

Applications of Three-Dimensional Measurement System for Shape Analysis -Focused on WBS and RapidForm 2004- (입체 형상 분석을 위한 3차원 계측시스템의 활용 -WBS와 RapidForm 2004를 중심으로-)

  • Lee Myung-Hee;Jung Hee-Kyeong
    • Journal of the Korean Society of Costume
    • /
    • v.55 no.5 s.95
    • /
    • pp.55-64
    • /
    • 2005
  • The concern with three-dimensional measurement has been growing in recent years. And over the last few years, several studies have been made on three-dimensional measurement. Some of the studies using a three-dimensional measurement have focused on type of form of human body and evaluation of fitness. But there has been no study about applications of three-dimensional measurement system for shape analysis. So, the purpose of this study was to investigate about application of three-dimensional mea-surement system lot shape analysis. The instrument and tools for three-dimensional measurement was Whole Body 3D scanner(model name: Exyma-WBS2H). Analysis program used in experiment is Rapid Form 2004 PPI (INUS technology, Int, Korea). The following results were obtained; 1. The point data using three-dimensional measurement system built 3D model. 2. The three-dimensional data were used to analyze length and curvature of shape. 3. The shape using three-dimensional measurement system could be used in variety field.

A Study for Quality Improvement of Three-dimensional Body Measurement Data (3차원 인체치수 조사 자료의 품질 개선을 위한 연구)

  • Park, Sun-Mi;Nam, Yun-Ja;Park, Jin-Woo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.117-124
    • /
    • 2009
  • To inspect the quality of data collected from a large-scale body measurement and investigation project, it is necessary to establish a proper data editing process. The three-dimensional body measurement may have measuring errors caused from measurer's proficiency or changes in the subject's posture. And it may also have errors caused in the process of algorithm expressing the information obtained from the three-dimensional scanner into numerical values, and in the course of data-processing dealing with numerous data for individuals. When those errors are found, the quality of the measured data is deteriorated, and they consequently reduce the quality of statistics which was conducted on the basis of it. Therefore this study intends to suggest a new way to improve the quality of the data collected from the three-dimensional body measurement by proposing a working procedure identifying data errors and correcting them from the whole data processing procedure-collecting, processing, and analyzing- of the 2004 Size Korea Three-dimensional Body Measurement Project. This study was carried out into three stages: Firstly, we detected erroneous data by examining of logical relations among variables under each edit rule. Secondly, we detected suspicious data through independent examination of individual variable value by sex and age. Finally, we examined scatter-plot matrix of many variables to consider the relationships among them. This simple graphical tool helps us to find out whether some suspicious data exist in the data set or not. As a result of this study, we detected some erroneous data included in the raw data. We figured out that the main errors are not because of the system errors that the three-dimensional body measurement system has but because of the subject's original three-dimensional shape data. Therefore by correcting some erroneous data, we have enhanced data quality.

Classification and Characteristics of Neck-base Shape of Korean Females in Their Twenties (20대 여성의 목밑둘레 형태 유형화 및 특징)

  • Hwang Keun Young;Nam Yun Ja;Park Jae Kyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.3_4 s.141
    • /
    • pp.502-510
    • /
    • 2005
  • The purpose of this study is to identify neck shapes of women by classifying their neck-base types according to the shapes of neck and analyzing the characteristics of each type. The subjects were 58 women $18\~24$ years of age. Their body were measured directly and indirectly by using camera, 3-dimensional body scanner. The anthropometric measurements were composed of 17 items. They were measured during the months of October in 2001 The results and discussions of this study are as follows. There were three kinds of neck-base type. The first type was slant from the back neck-base to the side neck-base, and slant from the side neck-base to the front neck-base. The second type was gentle from the back neck-base to the side neck-base, and gentle from the side nect-base to the front neck-base. finally, the third type was gentle from the back neck-base to the side neck-base, and slant from the side neck-base to the front neck-base. Hopefully, understanding the shapes of neck and characteristics of each neck-base type will help to suggest computer assisted neck-base's landmark identification algorithms and measurement extraction methods from three-dimensional body scan data.

Lower-body figure analysis of Chinese adult women

  • Cha, Sujoung
    • The Research Journal of the Costume Culture
    • /
    • v.22 no.6
    • /
    • pp.965-978
    • /
    • 2014
  • To determine the parameters to be considered when designing lower-body apparel, we analyzed the lower-body figures of adult women in their early 20s from Shanghai, China, using 3-dimensional whole body scanner. Thirty-nine lower-body-related measurements were used to analyze the figures of 210 Chinese women. Obesity and height of the lower body, length from waist to crotch, shape of abdomen, and leg bone length were analyzed. Factor analysis was performed and the results were classified into three clusters. The first cluster describes the obesity of the lower body, the second denotes small hip measurement, and the third describes slim and long legs. This is the first study to quantify figure analysis of the lower body of Chinese women using 3-dimensional body measurements. The findings of this study will provide concrete information regarding crotch width, crotch length, inseam, outseam, waist slope, etc., for designing trouser patterns for Chinese adult women.

Hardness Distribution and Dimensional Change after Partial- Hardened Hot Stamping of Automotive Body Part (국부 연화 핫스탬핑 차체 부품의 경도 분포 및 열 변형 거동)

  • Jeong, Woo Chang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.2
    • /
    • pp.66-73
    • /
    • 2022
  • Partial-hardened hot stamping has been well known to be very effective to absorb more energy in automotive lateral crash. Hardness distribution and dimensional change after partial-hardened hot stamping have been studied to find out effect of thermal deformation of the heated hot stamping die on dimensional accuracy of automotive center pillar. Soft zone of commercial center pillar showed 275~345 in Vickers hardness, indicating bigger non-uniformity which resulted from thermal deformation of heated die. Dimensional changes in soft zone of the commercial center pillar measured by three dimensional scanner were much bigger than that in hard zone. It has been found that hot stamping die compensation considering thermal deformation in soft zone causes a significant decrease in hardness deviation in the soft zone, corresponding to 20 percent of commercial center pillar and subsequently leads to much higher dimensional accuracy.