• Title/Summary/Keyword: Three leg inverter

Search Result 46, Processing Time 0.025 seconds

Performance Analysis of a Five-leg Inverter for the Train Propulsion System (철도차량 추진시스템을 위한 FLI(Five-leg Inverter)의 성능 분석)

  • Lim, Young-Seol;Shin, Duck-Ho;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.43-54
    • /
    • 2017
  • This paper analyzes the performance of two three-leg inverters and a five-leg inverter and proposes the optimal operation conditions in applying the five-leg inverter for the train propulsion system. The five-leg inverter offers a saving of two switches compared with the standard two three-leg inverters and it is possible to control two three-phase motors independently by using a control board. All of these features lead to a potential reduction in capital cost and miniaturization of system. In this paper, first, the analysis of the existing motor control method and PWM method for two-traction motor drive of urban railway is implemented. Next, the operation principle and performance of five-leg inverter is introduced. Through the analysis, when it applies the same motor control method and the same PWM method for three-leg inverter and five-leg inverter, the characteristic of motor's speed and torque is compared.

A Novel PWM Method for Three-Leg Two-Phase Inverter Fed Two-Phase Induction Motor (2상 유도전동기 구동 2상 인버터를 위한 새로운 PWM제어방식 II - 3-레그 타입의 경우 -)

  • Jang Do-Hyun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.339-346
    • /
    • 2005
  • It is complex to realize the reference voltage vector by the space vector PWM method in three-leg two-phase inverter In this paper a new PWM technique for three-leg two-phase inverter fed two-phase induction motor is poroposed assuming that three-leg two-phase inverter is equivalent circuit for 'four-leg two-phase inverter with the connected two windings'. From assumption, six sectors are decreased to four sectors, and simple sinusoidal PWM method instead of SVPWM is applied to three-leg two-phase inverter. Also, the switching pattern to determine the switching periods at each sector is proposed. Practical verification of theoretical predictions is presented to confirm the capabilities of the new techniques.

The Comparative Analysis of 2-Phase Inverter Topologies for 2-Phase Induction Motor (2상 유도전동기 구동을 위한 2상 인버터 토폴로지의 비교 분석)

  • Kim, Dong-Ki;Yoon, Duck-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1013-1018
    • /
    • 2016
  • In this paper, three kinds of the inverter topologies for the variable speed drive of 2-phase induction motor are compared and analyzed. The 2-phase inverters are classified into 2-leg, 3-leg, and 4-leg types depending on the number of power switching devices. And they use the output voltage vectors of the different forms according to the inverter topologies. Based on the comparative analyzed results, the effective values of output voltage have been defined by the linear modulation range. Therefore, the motor design guideline is proposed in order to decide a rated voltage of 2-phase induction motor according to the inverter topologies. Also, the computer simulations are carried out to verify the output voltage and current characteristics of each inverter topology.

3-Dimensional SVM Technique for the Three-Phase Four-Leg Voltage Source Inverter System (3상 4레그 전압형 인버터를 위한 3차원 공간벡터변조 기법)

  • Doan, Van-Tuan;Choi, Woo-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.111-112
    • /
    • 2013
  • The three-phase four-leg voltage source inverter (VSI) topology can be an interesting option for the three phase-four wire system. With an additional leg, this topology can handle the neutral current, hence the DC link capacitance can be reduced significantly. In this paper the three dimensional space vector modulation (3D SVM) in ${\alpha}{\beta}{\gamma}$ coordinates for the three-phase four-leg VSI is presented. By using the 3D SVM method, the DC link voltage can be reduced by 16% compared with the split DC link capacitor topology and the output distortion can also be reduced under the unbalanced load condition.

  • PDF

Design of a Hybrid Controller for the Three-phase Four-leg Voltage-source Inverter with Unbalanced Load

  • Doan, Van-Tuan;Kim, Ki-Young;Choi, Woojin;Kim, Dae-Wook
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.181-189
    • /
    • 2017
  • The three-phase four-leg voltage-source inverter topology is an interesting option for the three-phase four-wire system. With an additional leg, this topology can achieve superior performance under unbalanced and nonlinear load conditions. However, because of the low bandwidth of conventional controllers in high-power inverter applications, the system cannot guarantee a balanced output voltage under the unbalanced load condition. Most of the methods proposed to solve this problem mainly use the multiple synchronous frame method, which requires several controllers and a large amount of computation because of frame transformation. This study proposes a simple hybrid controller that combines proportional-integral (PI) and resonant controllers in the synchronous frame synchronized with the positive-sequence component of the output voltage of the three-phase four-leg inverter. The design procedure for the controller and the theoretical analysis are presented. The performance of the proposed method is verified by the experimental results and compared with that of the conventional PI controller.

Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-Leg Three-Phase PWM Inverters (2-레그 3상 PWM 인버터의 출력전압에서 직류링크 리플전압의 영향 보상)

  • Kim Young-Sin;Lee Dong-Choon;Seok Jul-Ki
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • In this paper, a simple scheme compensating for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, where single-phase half-bridge PWM convertor and two-leg inverter are used. The voltage at neutral point of the dc-link is controlled so that the upper-half of do-link voltage is equal to the lower-half voltage in average concept. However, the effect of the do-link ripple voltage results in the inverter output voltage and current distortion. This effect can be eliminated by introducing a compensation voltage in switching time calculation. Also, the inverter dead time should be compensated for sinusoidal output waveform. The proposed scheme has been verified by experimental results which were obtained from the V/F constant operation of the induction motor fed by two-leg inverter.

Design of the Robust Hybrid Controller for Three-Phase Four-Leg Voltage Source Inverter under the Unbalance Load (불평형 부하에서 강인한 3상4족 전압형 인버터를 위한 하이브리드 제어기의 설계)

  • Doan, Van-Tuan;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.291-292
    • /
    • 2014
  • The three-phase four-leg voltage source inverter (VSI) topology can be an interesting option for the three phase-four wire system. With an additional leg, this topology can achieve superior performance with unbalanced and/or nonlinear load. This paper proposes a new hybrid controller which combines PI controller and resonant controller in synchronous frame for three phase four leg inverter. The hybrid controller is simple in structure and easy to implement. The performance of proposed controller is verified by the experiments and compared with that of the conventional PI controller.

  • PDF

DC-Link Voltage Balance Control in Three-phase Four-wire Active Power Filters

  • Wang, Yu;Guan, Yuanpeng;Xie, Yunxiang;Liu, Xiang
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1928-1938
    • /
    • 2016
  • The three-phase four-wire shunt active power filter (APF) is an effective method to solve the harmonic problem in three-phase four-wire power systems. In addition, it has two possible topologies, a four-leg inverter and a three-leg inverter with a split-capacitor. There are some studies investigating DC-link voltage control in three-phase four-wire APFs. However, when compared to the four-leg inverter topology, maintaining the balance between the DC-link upper and lower capacitor voltages becomes a unique problem in the three-leg inverter with a split-capacitor topology, and previous studies seldom pay attention to this fact. In this paper, the influence of the balance between the two DC-link voltages on the compensation performance, and the influence of the voltage balance controller on the compensation performance, are analyzed. To achieve the balance between the two DC-link capacitor voltages, and to avoid the adverse effect the voltage balance controller has on the APF compensation performance, a new DC-link voltage balance control strategy for the three-phase four-wire split-capacitor APF is proposed. Representative simulation and experimental results are presented to verify the analysis and the proposed DC-link voltage balance control strategy.

Control of the Neutral Leg in Three-Phase Four-Wire Inverter Using Proportional-Resonant Controller (PR 제어기를 이용한 3상 4선식 인버터 Neutral Leg 제어 방법)

  • Han, Jungho;Song, Joongho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.54-61
    • /
    • 2015
  • In 3-phase 4-wire inverter, the unbalanced loads cause to increase the neutral current which brings the voltage deviation between the split dc-link capacitors to be larger. In order to solve this problem, a neutral leg is provided additively to the ordinary inverter circuit and the associated control methods are devised. This paper proposes a new neutral-leg controller based on a PR controller and shows relatively good performance even under unbalanced linear loads and nonlinear loads. The proposed control strategy illustrates its effectiveness under the various operating conditions through simulation works.

A Simplified Modulation Strategy for Three-leg Voltage Source Inverter Fed Unsymmetrical Two-winding Induction Motor

  • Sinthusonthishat, Saliltip;Chuladaycha, Nontawat
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1337-1344
    • /
    • 2013
  • This paper presents a simplified modulation strategy for the three-leg VSI fed two-winding induction motor. The strategy provides independent unbalanced voltage control for the main and auxiliary windings. This make the motor can be reversed rotation through the range of motor speed operation without limitation of voltage boost of the auxiliary winding. To study the advantages of the proposed drive, the experimental results such as voltage stresses, hysteresis band of the currents in locus, and also acoustic noise levels of the three-leg VSI are compared with those of the conventional two-leg topology. The results obviously show that the proposed technique achieves superior performance compared with the traditional scheme in case of dramatic increase of DC bus utilization, effective reduction of harmonic voltages content, and also significant enhancement of motor efficiency.