• Title/Summary/Keyword: Three dimensional echocardiography

Search Result 22, Processing Time 0.027 seconds

MR Imaging of Congenital Heart Diseases in Adolescents and Adults

  • Yeon Hyeon Choe;I-Seok Kang;Seung Woo Park;Heung Jae Lee
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.121-131
    • /
    • 2001
  • Echocardiography and catheterization angiography suffer certain limitations in the evaluation of congenital heart diseases in adults, though these are overcome by MRI, in which a wide field-of view, unlimited multiplanar imaging capability and three-dimensional contrast-enhanced MR angiography techniques are used. In adults, recently introduced fast imaging techniques provide cardiac MR images of sufficient quality and with less artifacts. Ventricular volume, ejection fraction, and vascular flow measurements, including pressure gradients and pulmonary-to-systemic flow ratio, can be calculated or obtained using fast cine MRI, phase-contrast MR flow-velocity mapping, and semiautomatic analysis software. MRI is superior to echocardiography in diagnosing partial anomalous pulmonary venous connection, unroofed coronary sinus, anomalies of the pulmonary arteries, aorta and systemic veins, complex heart diseases, and postsurgical sequelae. Biventricular function is reliably evaluated with cine MRI after repair of tetralogy of Fallot, and Senning's and Mustard's operations. MRI has an important and growing role in the morphologic and functional assessment of congenital heart diseases in adolescents and adults.

  • PDF

Preliminary study on the effects of pergolide on left ventricular function in the horses with pituitary pars intermedia dysfunction

  • Gehlen, Heidrun;Fisch, Judith;Merle, Roswitha;Trachsel, Dagmar S.
    • Journal of Veterinary Science
    • /
    • v.22 no.5
    • /
    • pp.64.1-64.12
    • /
    • 2021
  • Background: Pituitary pars intermedia dysfunction (PPID), a neurodegenerative disease leading to reduced dopamine production, is a common disease in aged horses. The treatment is based on administration of the dopamine agonist pergolide. This drug has been related to valvular fibrosis in humans, but the cardiovascular effect of this drug has not yet been investigated in horses. Objectives: To determine whether pergolide induces valvular disease in horses or affects the cardiac function. Methods: Standard, tissue Doppler (TDE) and two-dimensional speckle tracking (STE) echocardiography were performed in horses with diagnosed PPID based on adrenocorticotropic hormone dosage. Measurements taken in horses treated with pergolide were compared with those from untreated horses with nonparametric t-tests. Furthermore, measurements from follow-up examinations performed at least three months after the initial exam were compared with a Wilcoxon signed rank test for repeated measurements in each group. Results: Twenty-three horses were included. None of the 12 horses under treatment developed valvular regurgitation. Furthermore, no differences in the measurements of the left ventricular systolic or diastolic function could be seen between the group of horses with treatment and those without treatment. Measurements taken in the follow-up exam did not differ compared to those taken in the initial exam in both groups. Conclusions: No changes of the left ventricular function assessed by TDE and STE could be shown in a small population of horses with confirmed PPID. Treatment with pergolide did not affect the ventricular function nor induce valvular disease.

A New Method for Aortic Valve Planimetry with High-Resolution 3-Dimensional MRI and Its Comparison with Conventional Cine MRI and Echocardiography for Assessing the Severity of Aortic Valvular Stenosis

  • Hae Jin Kim;Yeon Hyeon Choe;Sung Mok Kim;Eun Kyung Kim;Mirae Lee;Sung-Ji Park;Joonghyun Ahn;Keumhee C. Carriere
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1266-1278
    • /
    • 2021
  • Objective: We aimed to compare the aortic valve area (AVA) calculated using fast high-resolution three-dimensional (3D) magnetic resonance (MR) image acquisition with that of the conventional two-dimensional (2D) cine MR technique. Materials and Methods: We included 139 consecutive patients (mean age ± standard deviation [SD], 68.5 ± 9.4 years) with aortic valvular stenosis (AS) and 21 asymptomatic controls (52.3 ± 14.2 years). High-resolution T2-prepared 3D steady-state free precession (SSFP) images (2.0 mm slice thickness, 10 contiguous slices) for 3D planimetry (3DP) were acquired with a single breath hold during mid-systole. 2D SSFP cine MR images (6.0 mm slice thickness) for 2D planimetry (2DP) were also obtained at three aortic valve levels. The calculations for the effective AVA based on the MR images were compared with the transthoracic echocardiographic (TTE) measurements using the continuity equation. Results: The mean AVA ± SD derived by 3DP, 2DP, and TTE in the AS group were 0.81 ± 0.26 cm2, 0.82 ± 0.34 cm2, and 0.80 ± 0.26 cm2, respectively (p = 0.366). The intra-observer agreement was higher for 3DP than 2DP in one observer: intraclass correlation coefficient (ICC) of 0.95 (95% confidence interval [CI], 0.94-0.97) and 0.87 (95% CI, 0.82-0.91), respectively, for observer 1 and 0.97 (95% CI, 0.96-0.98) and 0.98 (95% CI, 0.97-0.99), respectively, for observer 2. Inter-observer agreement was similar between 3DP and 2DP, with the ICC of 0.92 (95% CI, 0.89-0.94) and 0.91 (95% CI, 0.88-0.93), respectively. 3DP-derived AVA showed a slightly higher agreement with AVA measured by TTE than the 2DP-derived AVA, with the ICC of 0.87 (95% CI, 0.82-0.91) vs. 0.85 (95% CI, 0.79-0.89). Conclusion: High-resolution 3D MR image acquisition, with single-breath-hold SSFP sequences, gave AVA measurement with low observer variability that correlated highly with those obtained by TTE.

A Clinical Study of Patent Ductus Arteriosus (동맥관개존증의 임상적 고찰)

  • Bang, Jong-Gyeong;Kim, Gyu-Tae
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.309-316
    • /
    • 1987
  • Since the first report of successful ligation of patent ductus arteriosus in 1939, it`s surgical intervention has become a routine and relatively safe procedure. During the past ten years from Aug. 1975 to Aug. 1985, 107 cases were operated on for a patent ductus arteriosus at the Department of thoracic and Cardiovascular Surgery, School of Medicine, Kyungpook National University. Clinical analysis of these cases was performed. Mean age at operation was 9.4 years, ranging from 20 months to 32 years. Sex ratio of female to male was 1.8;1. Most common symptoms were frequent respiratory infection, exertional dyspnea, and palpitation. Diagnosis was made by auscultation, 2 dimensional echocardiography, cardiac catheterization, and cineangiocardiography. A moderate to severe pulmonary hypertension was found in 42 cases [49.4%] in cardiac catheterization. Operative methods were multiple ligation of paten`. ductus arteriosus with or without Dacron or Teflon wrapping in 72 cases [68%], and division and suture in 34 cases [32%]. There were three operative deaths [2.8%]. The causes of death were hemorrhage from tearing of aorta, low cardiac output, and arrhythmia. All of these cases had moderate degree of pulmonary hypertension.

  • PDF

Surgical treatment of coarctation of aorta in infants -Four cases of subclavian flap aortoplasty- (유아에서의 대동맥 축착증 치험 4예)

  • 백광제
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.506-514
    • /
    • 1986
  • Coarctation of aorta is rather common congenital cardiovascular defect in the western countries, but it is known to be rare in Korea. And no coarctation of Aorta has been reported and operated upon during early infancy in Korea. During 4 months period from May 1984 to September 1984, four small infants of coarctation of aorta were seen and treated surgically by subclavian flap aortoplasty in Guro Hospital, Korea University. All infants were male, ranging from 7 days to 54 days old [mean 29 days], weighing between 3.2 Kg and 5.0 Kg [mean 4.1 Kg], and all were in congestive heart failure. Examination of the femoral artery pulse gave in all cases clues to the diagnosis. By Two dimensional echocardiogram, detail anatomical features as well as the diagnosis were revealed and associated anomalies, for example, ventricular septal defect could be seen. Besides one case of isolated coarctation of aorta, other three infants had associated VSD. The 3 patients with VSD were treated by pulmonary artery banding in addition to aortoplasty. The postoperative course were smooth in all patients. In conclusion, coarctation of aorta may not be so rare in Korea as we thought previously. The importance of femoral pulse examination can not be overemphasized for the diagnosis. As we experienced, two-dimensional echocardiography in most cases can substitute those invasive examinations such as angiography and catheterization which carry difficulty and risk in infants.

  • PDF

Application of Three-Dimensional Printed Models in Congenital Heart Surgery: Surgeon's Perspective (선천성 심기형의 수술에 있어서 삼차원 프린팅 모델의 적용: 심장외과의사의 관점)

  • Hyungtae Kim;Ki Seok Choo;Si Chan Sung;Kwang Ho Choi;Hyoung Doo Lee;Hoon Ko;Joung-Hee Byun;Byung Hee Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.310-323
    • /
    • 2020
  • To treat congenital heart disease, it is important to understand the anatomical structure correctly. Three-dimensional (3D) printed models of the heart effectively demonstrate the structural features of congenital heart disease. Occasionally, the exact characteristics of complex cardiac malformations are difficult to identify on conventional computed tomography, magnetic resonance imaging, and echocardiography, and the use of 3D printed models can help overcome their limitations. Recently, 3D printed models have been used for congenital heart disease education, preoperative simulation, and decision-making processes. In addition, we will pave the way for the development of this technology in the future and discuss various aspects of its use, such as the development of surgical techniques and training of cardiac surgeons.

Three-Dimensional Printed Model of Partial Anomalous Pulmonary Venous Return with Biatrial Connection (양측 심방 연결을 형성하는 부분 폐정맥 환류 이상의 3D 프린팅 모델)

  • Myoung Kyoung Kim;Sung Mok Kim;Eun Kyoung Kim;Sung-A Chang;Tae-Gook Jun;Yeon Hyeon Choe
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1523-1528
    • /
    • 2020
  • Partial anomalous pulmonary venous return (PAPVR) is a rare congenital cardiac anomaly that can be difficult to detect and often remains undiagnosed. PAPVR is diagnosed using non-invasive imaging techniques such as echocardiography, CT, and MRI. Image data are reviewed on a 2-dimensional (D) monitor, which may not facilitate a good understanding of the complex 3D heart structure. In recent years, 3D printing technology, which allows the creation of physical cardiac models using source image datasets obtained from cardiac CT or MRI, has been increasingly used in the medical field. We report a case involving a 3D-printed model of PAPVR with a biatrial connection. This model demonstrated separate drainages of the right upper and middle pulmonary veins into the lower superior vena cava (SVC) and the junction between the SVC and the right atrium, respectively, with biatrial communication through the right middle pulmonary vein.

Bivenrticular Repair of Double Outlet Right Ventricle with Remote Ventricular Septil Defect. (비상관성 심실중격결손중을 동반한 양대혈관우심실기시증 환자에서의 양심실성 교정)

  • 방정현;이영탁
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.641-646
    • /
    • 1997
  • Understanding of the surgical anatomy of patients with double outlet right ventricle (DORV) is important in the planning of biventricular repair From May 1995 to September 1996, 7 patients underwent biventricular repair for DORV with remote ventricular septal defect. There were 5 males and 2 (tamales. Age at operation varied from 2 to 9 years(mean 3.4$\pm$ 2.7years). Preoperative diagnostic assessment was made by two-dimensional echocardiography and cardiac catheterization. Ventricular septal defect was perimembranous inlet type in all patients. Associated cardiac anomalies were pulmonary atresia in two, pulmonary stenosis in five and tricuspid chordal attachment to zonal septum in five. The operations were performed intraventricular repair and pulmonary enlargement in two, REV operation in two, and Rastelli operation in three. There was no early postoperative deaths and complications. The follow-up period war from 1 month to 18mon1hs, averaging 10: 6.1 months. In the past, we considered the Fontal operation indicative as primary choice when DORV was associated with abnormal tricuspid chordal attachment to the zonal septum, but now we believe that biventricular repair is feasible for those cases by making conal flap or reattachment method. Biventricular repair has theoretic advantages because it estabilishes normal anatomy and physiology, and it was concluded that the precise preoperative evaluation using both echocardiography and cardiac catheterization was essential to the successful surgery.

  • PDF

Utility of Multidetector Computed Tomographic Angiography as an Alternative to Transesophageal Echocardiogram for Preoperative Transcatheter Mitral Valve Repair Planning

  • Craig Basman;Caroline Ong;Tikal Kansara;Zain Kassam;Caleb Wutawunashe;Jennifer Conroy;Arber Kodra;Biana Trost;Priti Mehla;Luigi Pirelli;Jacob Scheinerman;Varinder P Singh;Chad A Kliger
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.1
    • /
    • pp.18-23
    • /
    • 2023
  • BACKGROUND: Three-dimensional (3D) transesophageal echocardiogram (TEE) is the gold standard for the diagnosis of degenerative mitral regurgitation (dMR) and preoperative planning for transcatheter mitral valve repair (TMVr). TEE is an invasive modality requiring anesthesia and esophageal intubation. The severe acute respiratory syndrome coronavirus 2 pandemic has limited the number of elective invasive procedures. Multi-detector computed tomographic angiography (MDCT) provides high-resolution images and 3D reconstructions to assess complex mitral anatomy. We hypothesized that MDCT would reveal similar information to TEE relevant to TMVr, thus deferring the need for a preoperative TEE in certain situations like during a pandemic. METHODS: We retrospectively analyzed data on patients who underwent or were evaluated for TMVr for dMR with preoperative MDCT and TEE between 2017 and 2019. Two TEE and 2 MDCT readers, blinded to patient outcome, analyzed: leaflet pathology (flail, degenerative, mixed), leaflet location, mitral valve area (MVA), flail width/gap, anterior-posterior (AP) and commissural diameters, posterior leaflet length, leaflet thickness, presence of mitral valve cleft and degree of mitral annular calcification (MAC). RESULTS: A total of 22 (out of 87) patients had preoperative MDCT. MDCT correctly identified the leaflet pathology in 77% (17/22), flail leaflet in 91% (10/11), MAC degree in 91% (10/11) and the dysfunctional leaflet location in 95% (21/22) of patients. There were no differences in the measurements for MVA, flail width, commissural or AP diameter, posterior leaflet length, and leaflet thickness. MDCT overestimated the measurements of flail gap. CONCLUSIONS: For preoperative TMVr planning, MDCT provided similar measurements to TEE in our study.

Identification and Assessment of Paradoxical Ventricular Wall Motion Using ECG Gated Blood Pool Scan - Comparison of Cine Loop, Phase Analysis and Paradox Image - (ECG Gated Blood Pool Scan을 이용한 심실벽 역행성 운동의 평가 - Cine Loop, Phase Analysis, Paradox Image의 비교 -)

  • Lee, Jae-Tae;Kim, Gwang-Weon;Jeong, Byeong-Cheon;Lee, Kyu-Bo;Whang, Kee-Suk;Chae, Sung-Chul;Jeon, Jae-Eun;Park, Wee-Hyun;Lee, Hyong-Woo;Chung, Jin-Hong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.244-253
    • /
    • 1990
  • Sixty-four patients with paradoxical ventricular wall motion noticed both in angiocardiography or 2-dimensional echocardiography were assessed by ECG gated blood pool scan (GBPS). Endless cine loop image, phase and amplitude images and paradox image obtained by visual inspection of each cardiac beat or Fourier transformation of acquired raw data were investigated to determine the incremental value of GBPS with these processing methods for identification of paradoxical ventricular wall motion. The results were as follows: 1) Paradoxical wall motions were observed on interventricular septum in 34 cases, left ventricular free wall in 26 and right ventricular wall in 24. Underlying heart diseases were ischemic (23 cases) valvular(9), congenital heart disease (12), cardiomyopathy (5). pericardial effusion(5), post cardiac surgery(3), col pulmonale (2), endocarditis(1) and right ventricular tumor(1). 2) Left ventricular ejection fractions of patients with paradoxical left ventricular wall motion were significantly lower than those with paradoxical septal motion(p<0.005). 3) The sensitivity of each processing methods for detecting paradoxical wall motion was 76.9% by phase analysis, 74.6% by endless cine loop mapping and 68.4% by paradox image manipultion respectively. Paradoxial motions visualized only in phase, paradox or both images were appeared as hypokinesia or akinesia in cine loop image. 4) All events could be identified by at least one of above three processing methods, however only 34 cases (48.4%) showed the paradoxical molies in all of the three images. By these findings, we concluded that simultaneous inspection of all above three processing methods-endless cine loop, phase analysis and paradox image-is necessary for accurate identification and assessment of paradoxical ventricular wall motion when performing GBPS.

  • PDF