• Title/Summary/Keyword: Thickness vibration mode

Search Result 231, Processing Time 0.024 seconds

Dielectric and Piezoelectric Characteristics of Low Temperature Sintering PbTiO3 System Ceramics with amount of Bi2O3 Addition (Bi2O3 첨가량에 따른 저온소결 PbTiO3계 세라믹스의 유전 및 압전특성)

  • Yoo, Ju-Hyun;Kim, Do-Hyung;Lee, Sang-Ho;Sohn, Eun-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.771-775
    • /
    • 2007
  • In this study, in order to develop low temperature sintering ceramics for thickness vibration mode multilayer piezoelectric transformer, $PbTiO_3$ system ceramics were fabricated using $Na_2CO_3,\;Li_2CO_3,\;MnO_2\;and\;Bi_2O_3$ as sintering aids and their dielectric and piezoeletric properties were investigated according to the amount of $Bi_2O_3$ addition. At the sintering temperature of $900^{\circ}C\;and\;Bi_2O_3$ addition of 0.1 wt%, density, grain size, thickness vibration mode eletromechanical coupling factor($k_t$), thickness vibration mode mechanical quality factor($Q_{mt}$) and dielecteic constant(${\varepsilon}_r$) showed the optimum value of $6.94g/cm^3,\;2.413{\mu}m$, 0.497, 3,162 and 209, respectively, for thickness vibration mode multilayer piezoelectric transformer application.

Voltage Gain Characteristics of Piezoelectric Transformer Operation in Second Thickness Extensional Vibration Mode (2차 두께방향 지동모드로 동작되는 압전트랜스포머의 Voltage Gain 특성)

  • 김성진;이수호;류주현;임인호;홍재일
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.855-860
    • /
    • 1998
  • This paper presents a new structure for a piezoelectric transformer, operating in thickness extensional vibration mode. Modified $PbTiO_3$ family ceramics were used for the piezoelectric transformer, because it was a material with large anisotropy between elecromechanical coupling factors $K_t$ and $K_p$ . The size of piezoelectric transformer was 20mn long, 20mm wide and 3.1mm thick. The second harmonic resonant frequency of thickness extensional vibration mode was 0.72MHz at loading resistance 100[$\omega$], And Voltage gin of piezoelectric ceramics showed 0.53 at resonant frequency of sencond thickness extensional vibration mode.

  • PDF

Particle displacement distributions of energy-trapped thickness shear vibrations in the piezoelectric substrate (압전체 기판에서 에너지 포획된 두께 전단진동의 변위분포)

  • 이개명
    • Electrical & Electronic Materials
    • /
    • v.9 no.9
    • /
    • pp.954-963
    • /
    • 1996
  • Particle displacement distributions of the fundamental thickness shear vibration mode and overtone modes in an energy-trapped single resonator and an energy-trapped double acoustically coupled filter were calculated. The effects of the width of a pair of partial eletrodes and the magnitude of the plate back of the resonator on the particle displacement distributions of its symmetric vibration mode and anti-symmetric vibration mode were investigated. And the effects of the width of a pair of partial eletrodes, the width of the gap between two pairs of partial electrodes and the magnitude of the plate back of the filter on the particle displacement distributions of its symmetric vibration mode and anti-symmetric vibration mode were investigated.

  • PDF

Thickness-Vibration-Mode Piezoelectric Transformer for Power Converter

  • Su-Ho lee;Yoo, Ju-Hyun;Yoon, H.S.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.3
    • /
    • pp.1-5
    • /
    • 2000
  • This paper presents a new sort of multilayer piezoelectric ceramic transformer for switching regulation power supplies. This piezoelectric transformer operate in the second thickness resonant vibration mode. Accordingly its resonant frequency is higher than 1 NHz, Because output power is low if input and output part of transformer are consisted of single layer, this research suggests a new method, which is consisted of both input and output part of transformer have 2-layered piezoelectric ceramics, The size of transformer is 20 mm in width and length, and 1.4 mm in thickness, respectively, To design a high efficient switching circuit of the transformer, internal circuit parameters were measured and then weve calculated a parameter of inductor nd capacitor to design a driving circuit, Weve used a MISFET and its driver circuit modified a calp oscillator circuit as the primary switching circuit.

  • PDF

ANSYS Simulation of VHF Ceramic Resonator Using Thickness-longitudinal vibration mode (두께 진동모드를 이용한 고주파 세라믹 Resonator의 ANSYS Simulation)

  • 홍재일;윤현상;민석규;윤광희;류주현;김종선;박창엽
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.259-262
    • /
    • 2000
  • In this study, 3.1$\times$3.7$\times$0.365 $\textrm{mm}^2$ model of thickness-longitudinal vibration mode VHF ceramic resonator with (Pb,Ca)(Co,W,Ti)O$_3$ ceramics was simulated by ANSYS according to the electrode size. With the variations of electrode size of the model, fundamental and the third overtone dynamic ratio was investigated. At the ratio of electrode to model thickness(1/t) 2.5, third overtone dynamic ratio was largely increased. That model is suitable for 20 MHz resonator.

  • PDF

Vibration Characteristics of Conical Shells with Linearly Varying Thickness (선형적으로 두께가 변하는 원추형 셸의 진동특성)

  • Yeo, D.J.;Cho, I.S.
    • Journal of Power System Engineering
    • /
    • v.12 no.2
    • /
    • pp.35-40
    • /
    • 2008
  • This paper deals with the free vibrations of conical shells with linearly variable thickness by the transfer influence coefficient method. The classical thin shell theory based upon the Flugge theory is assumed and the governing equations of a conical shell are written as a coupled set of first order matrix differential equations using the transfer matrix. The Runge-Kutta-Gill integration method is used to solve the governing differential equation. The natural frequencies and corresponding mode shapes are calculated numerically for the conical shells with linearly variable thickness and various boundary conditions at the edges. The present method is applied to conical shells with linearly varying thickness, and the effects of the semi-vertex angle, the number of circumferential waves and thickness ratio on vibration are studied.

  • PDF

Finite Element Analysis of Step-down Piezoelectric Transformer with Various Shape (형태의 변화에 따른 강압용 압전변압기의 유한요소해석)

  • Chong, Hyon-Ho;Park, Tae-Gone;Kwon, Oh-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.697-700
    • /
    • 2003
  • This paper presents design and analysis of step-down piezoelectric transformer for application to AC-adapters. These transformers are consist of rectangular type and disk type multilayered piezoelectric ceramic plate. This piezoelectric transformer operated in third thickness resonance vibration mode. Finite element methode(FEM) was used for analysing transformer. Vibration mode and electric field of piezoelectric transformer were simulated at resonance frequency. As results, rectangular type transformer's output voltage was higher than the disk type. But disk type transformer's current was lagger than rectangular type. These results are assumed that disk type transformer's mixed vibration mode influence transformer's output characteristics. From these results, we expect that disk type piezoelectric transformer is more adoptable than rectangular plate type piezoelectric transformer for AC adapters.

  • PDF

Experimental Modal Analysis of Two Unequal Rectangular Plates Coupled with Fluid (유체로 연성되고 두께가 상이한 두 직사각 평판의 실험적 모드 해석)

  • Yoo, Gye-Hyoung;Jeong, Kyeong-Hoon;Lee, Seong-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.12
    • /
    • pp.2541-2549
    • /
    • 2002
  • In order to study the vibration characteristics of fluid-structure interaction problem, two rectangular plates coupled with bounded fluid were investigated. Experimental modal analyses were carried out to extract the modal parameters of the system. Additionally. finite element modal analyses performed using a commercial computer code, ANSYS. The FEM solutions were compared with the experimental solutions to verify the finite element model. As a result, the comparison between the experiment and FEM results showed excellent agreement. The transverse vibration modes, in-phase and out-of-phase, were observed alternately in the fluid-coupled system. The thickness effect of the plates on the fluid-coupled natural frequencies and mode shapes was investigated for two different cases with the identical thickness and the unequal thickness. It was found that the coupled natural frequencies increase with the thickness for the identical plates regardless of the mode phase. The experimental and the finite element analysis results showed that the out-of-phase mode shapes were deviated from the symmetrical mode shapes in the plate transverse direction fur the unequal plate thickness case.

Propagation of floor impact vibration in a 1:10 scale model of a test structure (1:10 축척 시험동 구조 모형의 바닥충격 진동 전달)

  • Lee, Pyoung-Jik;Yoo, Seung-Yup;Kim, Jae-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1455-1458
    • /
    • 2007
  • Vibration characteristics of concrete slabs were investigated using a 1:10 scale model and finite element method. A 1:10 scale model of a test building with 150 and 200mm slab thicknesses was made of acrylic materials. Modal test was conducted to investigate mode shape and modal frequencies. Results show that the mode shapes of two slabs with different thickness are similar each other, whereas natural frequency is different. Through modal analysis using FEM, it was revealed that both mode shapes and natural frequencies calculated from the FEM model are similar to those of the scale model measurement. It was also found that natural frequencies increased with increment of the slab thickness.

  • PDF

Trajectory of Resonant Displacement of Thickness Vibration Mode Piezoelectric Devices According to Diameter/Thickness Ratio (두께와 직경 비에 따른 두께진동모드 압전소자의 공진 변위 궤적)

  • Jeong, Yeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.105-109
    • /
    • 2012
  • In this study, thickness vibration mode piezoelectric devices for AE sensor application were simulated using ATILA FEM program, and then fabricated. Trajectory resonant displacement and electro mechanical coupling factors of the piezoelectric devices were investigated. The simulation results showed that excellent displacement and electro mechanical coupling factor was obtained when the ratio of diameter/thickness($\Phi/T$) was 0.75. The piezoelectric device of $\Phi/T$=0.75 exhibited the optimum values of fr= 183 kHz, displacement= $4.44{\times}10^{-7}[m]$, $k_{33}$= 0.69, which were suitable for the application of AE sensor piezoelectric device.