• Title/Summary/Keyword: Theta Wave

Search Result 140, Processing Time 0.028 seconds

The Classification of the Schizophrenia EEG Signal using Hidden Markov Model (은닉 마코프 모델을 이용한 정신질환자의 뇌파 판별)

  • 이경일;김필운;조진호;김명남
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.217-225
    • /
    • 2004
  • In this paper, a new automatic classification method for the normal EEC and schizophrenia EEC using hidden Markov model(HMM) is proposed. We used the feature parameters which are the variance for statistical stationary interval of the EEC and power spectrum ratio of the alpha, beta, and theta wave. The results were shown that high classification accuracy of 90.9% in the case of normal person, and 90.5% in the case of schizophrenia patient. It seems that proposed classification system is more efficient than the system using complicate signal processing process. Hence, the proposed method can be used at analysis and classification for complicated biosignal such as EEC and is expected to give considerable assistance to clinical diagnosis.

Free In-plane Vibration of a Clamped Circular Plate (고정된 원형 플레이트의 평면내 자유진동)

  • Park, Chan-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.836-839
    • /
    • 2005
  • The in-plane vibration response of a clamped circular plate should be predicted in many applications. Up to now, papers on the in-plane vibration of rectangular plate are published. However, analytical derivation on the in-plane vibration of the clamped circular plate is not carried out. Therefore, the in-plane vibration of the clamped circular plate is the concern of this paper. In order to derive the equations of motion for the clamped circular plate in the cylindrical coordinate, the kinetic energy and potential energy for the in-plane behavior are obtained by us ing the stress-strain-displacement expressions. Application of Hamilton's principle leads to two sets of differential equations. These displacement equations were highly coupled. It is possible to obtain a simpler set of equations by introducing Helmholtz decomposition. Substituting them into the coupled differential equations, we obtain the uncoupled equations of motion. In order to solve them, we assume that the solutions are harmonic. Then, they lead to the wave equations. Using the separation of variable, we obtain the general solutions for the equations. Based on the solutions, the displacements for r and $\theta$ direction are assumed. Finally we obtain the frequency equation for the clamped circular plate by the application of boundary conditions. The derived equation is compared with the finite element analysis for validation by using the some numerical examples.

  • PDF

The Evaluation of Driver's Physiology Signal and Sensibility according to the Change of Speed and the Gap of Platoon on AHS (AHS에서 차량군의 속도와 거리 변화에 따른 운전자의 생체신호와 감성 평가)

  • Jeon, Yong-Uk;Park, Beom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.15-28
    • /
    • 2003
  • The one of the most important factors is the platoon design on developing AH3(Advanced Highway System), as it is related to traffic efficiency and drivers' safety. This study was evaluated that how much speed is comfortable for drivers and how long distance is appropriate for vehicular gap of platoon by measuring drivers' physiology signal and sensibility. A fixed-based AHS simulator was developed by using a real vehicle cockpit and the restructured part of Korean highway for human factors evaluation. The EEG(electroencephalogram), ECG (electrocardiogram) and GSR(Galvanic Skin Response) were measured for obtaining drivers' physiology signal according to the change of speed and gap. The brain wave(${\alpha},\;{\beta},\;{\delta},\;{\theta}$) by EEG, the response of the autonomic nervous system. the sympathetic and parasympathetic nervous system, by ECG, and relax-arousal situation by GSR were analyzed. The SD(Semantic Differential) method was also applied to evaluate drivers' sensibility by 5-grade evaluation scale with 96 adjectives. SSQ(Simulator Sickness Questionnaire) was used to measure the simulator sickness of pre and post driving, two times. As the results, drivers were comfortable with 120km/h speed of platoon and lam to 15m vehicular distance. The results of this study may differ from the adaption of the reality because of many parameters. However, the purpose of this study is show to significant results of the drivers' safety and the acceptability of human factors evaluation.

Studies on the Solubility Phenomenon and Activities of Silk Cocoon Sericin through the Filature Water Conditions. (제사용수의 수질이 견층세리신의 용해에 미치는 거동구명에 관한 연구)

  • 김병호
    • Journal of Sericultural and Entomological Science
    • /
    • v.16 no.2
    • /
    • pp.77-98
    • /
    • 1974
  • This study was carried out ill an attempt to investigate the properties and activities of sericin obtained from silk cocoon shells in silk reeling water through various instrumental analyses. In addition, the effects of the characteristics in sericin solubility on the reeling process and silk qualities were also studied on the basis of tile above conditions. The results obtained are as follows: I. The sericin properties and activities through various analytical instruments. 1. The water solubility of each amino acid such as serine, glycine. glutamic and aspartic acids against the pH modified water by using automatic amino acid analyzer, showed the lowest solubility at PH 5, but it increased according to drifting toward the alkalinity. 2. When the obtained sericin particles by water pH variation were observed with the electronic microscope, it was found for the sericin Particles to expand in the alkaline regions. 3. The IR spectrum results showed the differences among the pH modified sericin solutions at the range of 2,100cm-1 and 1.890cm-1 of wave number. 4. The existence of sericin with in silk fabrics made differences in the X-ray interference intencity, that is, the non-degummed fabrics had the interference peak at 2$\theta$=14$^{\circ}$, 17$^{\circ}$, 24$^{\circ}$, and the degummed ones had it at 2$\theta$=17$^{\circ}$, 18$^{\circ}$, 20$^{\circ}$, 23$^{\circ}$, 26$^{\circ}$. II. The results of sericin solubility for silk reeling process. 1. The sericin solubility and swelling had a tendency to increase up with high M-alkalinity and pH value of water. But in case of acidity. water hardness and concentration of ethylene glycol were high, the sericin solubility and swelling were decreased. 2. With the filature experiments, the best conditions of filature orator are summarized as fellows ; a. pH; 6.9${\pm}$0.2 d. acidity; below10ppm b. total hardness; 55:5ppm e. Fe ion; none c. M-alkalinity; 40${\pm}$10ppm

  • PDF

The Effects of Acupuncture on the Electroencephalogram of Patients with Stroke (자침이 중풍환자의 뇌파 변화에 미치는 영향)

  • Yoon, Ga-Young;Park, Ji-Min;Kim, Dong-Hyuk;Seon, Jong-In;Kang, Jung-Won;Nam, Dong-Woo;Lee, Seung-Deok;Choi, Do-Young;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.1-16
    • /
    • 2012
  • Objectives : The purpose of this study was to examine the effects of manual acupuncture at the $LI_4$, $ST_{36}$ and $LR_3$ on Electroencephalogram(EEG) of patients with stroke. Methods : 32 channel EEG measurement was carried out in 35 Stroke patients(23 males and 12 females). EEG was measured for 21 minutes(made up of 7 sessions, 1 session means 3 minutes time interval) including 15 minutes(5 sessions) of acupuncture time. Power spectrum analysis was used as a measure of complexity. Statistical analysis was performed using Linear mixed model and DUNNETT's multiple comparison. Results : The results were as follows; 1. EEG amplitude was reduced during acupuncture except electrodes PG1 and PG2. 2. There was a notable change during 6~9 minutes after needling in ${\delta}{\cdot}{\beta}{\cdot}{\gamma}$ wave, and during 6~9 minutes after needling in ${\Theta}{\cdot}{\alpha}$ wave. Overall, during 6~9 minutes after needling. 3. TP8 is a common significant electrode among five wave forms. Conclusions : These results suggest that TP8 could be typical electrodes and change of EEG compared to baseline happens most often during 6~9 minutes after manipulated acupuncture at the $LI_4$, $ST_{36}$ and $LR_3$ of patients with stroke.

Effects of Lavandula angustifolia aroma on electroencephalogram in male adults with good sleep quality and poor sleep quality (라벤더향이 수면질이 좋은 남자 성인과 수면질이 나쁜 남자 성인의 뇌파에 미치는 영향)

  • Jung, Hanna;Choi, Hyun Ju
    • Science of Emotion and Sensibility
    • /
    • v.15 no.4
    • /
    • pp.453-468
    • /
    • 2012
  • This study investigated the effects of Lavandula angustifolia (L. angustifolia) aroma on the brain electrical activity evaluated by an electroencephalogram (EEG) in the male adults since many researches were performed with females and few with males. Sleep quality of 35 male adults were analyzed by Pittsburgh sleep quality index, and they were divided into two groups of good sleep quality and poor sleep quality. EEG electrodes were attached at the frontal (F3, F4), temporal (T3, T4), occipital (O1, O2), and parietal (P3, P4) regions according to the International 10-20 system. EEG was measured for 3 min per each period of before, during, and after L. angustifolia aromatherapy. Subjects with good sleep quality showed increases in the delta power at the parietal region of both cerebral hemispheres and in the theta power at the temporal region of right hemisphere (p<0.05), and a decrease in the alpha at the parietal region of both cerebral hemispheres (p<0.05). And subjects with poor sleep quality showed increases in the delta power at the frontal region of left cerebral hemisphere and in the theta power at the frontal region of both hemispheres (p<0.05). It is concluded that L. angustifolia aroma has effects on decreasing an awakening status related-brain wave and increasing the sleep status related-brain waves in the male adults with good sleep quality, and has also effects on increasing the sleep status related-brain waves in the male adults with poor sleep quality.

  • PDF

EEG Changes due to Low-Frequency Electrical Stimulation to the BL62 and KI6 of Elderly Women (노년 여성의 신맥.조해 저주파 자극이 뇌파에 미치는 영향)

  • Lee, Sanghun;Choi, Kwang-Ho;Cho, Seong Jin;Choi, Sun-Mi;Hong, Kwon Eui;Ryu, Yeon-Hee
    • Korean Journal of Acupuncture
    • /
    • v.30 no.2
    • /
    • pp.135-142
    • /
    • 2013
  • Objectives : This study aimed to investigate the general effects of low-frequency electrical stimulation of the ankle joint acupuncture points(BL62 and KI6) on the brain waves of elderly women as a pilot study to figure out the possibility of candidate non-invasive and non-chemical stimulation method for the enhancing the brain function. Methods : A randomized, controlled, double-blinded clinical trial was performed in 31 healthy women(mean age, 54.5 years) within a treatment duration of 12 sessions. In the experimental group, low-frequency electrical stimulation was applied using the maximum range of the individual insensible strength(mean current, $0.04{\mu}A$). The control group received sham stimulation. The background electroencephalographic activity was measured before and after the12 sessions. Results : After 12 sessions of stimulation, the relative power of the alpha wave increased(32 of 32 channels: significant difference in 11 channels, p<0.05); the theta(30 of 32 channels: significant difference in 10 channels, p<0.05), beta(31 of 32 channels), and gamma(30 of 32 channels: significant difference in 7 channels, p<0.05) powers were also decreased compared with the sham group. Conclusions : Electrical stimulation on the ankle joint acupuncture points(BL62 and KI6) seemed to stabilize the elderly women brain by inducing the alpha power and reducing beta, theta, and gamma powers. These results provide insight into the action mechanism of the stimulation and can assist the future developement of a non-invasive and non-chemical treatment technique for stressor related cognitive problems.

Features of EEG Signal during Attentional Status by Independent Component Analysis in Frequency-Domain (독립성분 분석기법에 의한 집중 상태 뇌파의 주파수 요소 특성)

  • Kim, Byeong-Nam;Yoo, Sun-Kook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2170-2178
    • /
    • 2014
  • In this paper, electroencephalographic (EEG) signal of one among subjects measured biosignal with visual evoked stimuli inducing the concentration was analyzed to detect the changes in the attention status during attention task fulfillment from January to February, 2011. The independent component analysis (ICA) was applied to EEG signals to isolate the attention related innate source signal within the brain and Electroculogram (EOG) artifact from measured EEG signals at the scalp. The consecutive accumulation of short time Fourier transformed (STFT) attention source signal with excluded EOG artifact can enhance the regular depiction of EPOCH graph and spectral color map representing time-varying pattern. The extracted attention indices associated with somatosensory rhythm (SMR: 12-15 Hz), and theta wave (4-7 Hz) increase marginally over time. Throughout experimental observation, the ICA with STFT can be used for the assessment of participants' status of attention.

The Effect of Manual Acupuncture on the Waves of the Electroencephalogram (자침수기가 뇌파에 미치는 영향)

  • Seon, Jong-In;Lee, Seung-Deok;Han, Seung-Moo;Park, Mi-Ju;Kang, Jung-Won;Nam, Dong-Woo;Yoon, Ga-Young;Choi, Do-Young;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.28 no.2
    • /
    • pp.27-41
    • /
    • 2011
  • Objectives : The aim of this study was to examine the effect of manual acupuncture at the bilateral $LI_4$, $ST_{36}$ and $LR_3$ on normal human every 3 minute time interval by using power spectrum analysis. Methods : 25 healthy volunteers participated in this study. 32 channel EEG(Electroencephalogram) measurements were carried out before, during and after acupuncture treatments. In this study, power spectrum was used as a measure of complexity. Statistical analysis was performed using repeated measure ANOVA and Bonferroni method. Results : 1. In acupuncture group, Mean HRT, PSI, Normalized HF decreased significantly. SDNN, Ln(TP), Ln(LF), Ln(VLF), Normalized LF and LF/HF ratio increased significantly. RMSSD, Ln(HF) were not affected. 2. In sham acupuncture group, all indicators were not affected. 3. In control group, mean HRT, Ln(TP) decreased significantly. SDNN, RMSSD, PSI, Ln(LF), Ln(HF), Ln(VLF), normalized LF, normalized HF and LF/HF ratio were not affected. Conclusions : This results suggest that manipulation needling of 6 acupoints induced increase of delta, theta, beta waves. Both manipulation and simple needling induced decrease of alpha wave during 12~15 time intervals.

Methanol Extract of Longanae Arillus Regulates Sleep Architecture and EEG Power Spectra in Restraint-Stressed Rats

  • Ma, Yuan;Eun, Jae-Soon;Lee, Kwang-Seung;Lee, Eun-Sil;Kim, Chung-Soo;Hwang, Bang-Yeon;Oh, Ki-Wan
    • Natural Product Sciences
    • /
    • v.15 no.4
    • /
    • pp.213-221
    • /
    • 2009
  • Longanae Arillus (the rind of fruits of Dimocarpus longan) has been consumed for the treatment of insomnia and anxiety in Asia. To provide further scientific basis to traditional uses of this fruit on insomnia, we evaluated the effects of methanol extract of Longanae Arillus (MELA) on the alteration of sleep architecture and electroencephalogram (EEG) power spectra in acutely and chronically restraint-stressed rats. Following postsurgical recovery, Polygraphic signs of sleep-wake activities were recorded for 24 h after MELA administration in rats. Rats in the acute stress and chronic stress were administered with MELA for 10 days. On the $8^{th},\;9^{th}\;and\;10^{th}$ day of MELA administration, the rats were stressed for 3 h once per day. On the $10^{th}$ day and 1 h after MELA administration, the rats were stressed once for 22 h in the chronic stress group. Acute and chronic stress induced alternations in cortex EEG recordings during non-rapid eye movement (NREM), rapid eye movement (REM) sleep and wakefulness. MELA shortened the total and REM sleep and increased the wakefulness in night time recording without changing daytime recordings. Chronic stress increased wakefulness and REM sleep, decreased total and NREM sleep in the daytime recording, and increased REM and decreased NREM sleep without changing total sleep and wakefulness in night time recording. These findings suggest that MELA ameliorated the alterations in REM and NREM sleep of acutely and chronically stressed rats via modulation of cortical ${\alpha}-$, ${\theta}-$ and ${\delta}-$ wave activity.