• 제목/요약/키워드: Thermostats

검색결과 9건 처리시간 0.022초

열해석에 의한 인공위성 추진시스템 열설계 (Thermal Design for Satellite Propulsion System by Thermal Analysis)

  • 한조영;김정수;이승우
    • 대한기계학회논문집B
    • /
    • 제27권1호
    • /
    • pp.117-124
    • /
    • 2003
  • Thermal design fur satellite propulsion system has been performed. Overall design requirements and the constitution for propulsion system is described. To meet the thermal design requirements, both a primary and a redundant heater circuit, each with two thermostats placed in series, will protect each hydrazine-wetted components, even if one heater circuit fails to operate. Heater power is turned off if any one of these thermostats is opened at its higher setpoint. Thus, even if one thermostat is failed closed, the second thermostat will turn off the heater. All such components shall be insulated with MLI. Propulsion heater sizing based on the constant worst cold case condition is conducted through thermal analysis. All heaters selected fur propulsion components operate to prevent propellant freezing satisfying the thermal requirements for the propulsion subsystem over the worst case average voltage, i.e. 25 volts.

다목적실용위성 2호 추진계의 열설계 (Thermal Design for KOMPSAT-2 Propulsion System)

  • 한조영;김정수;이균호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.77-82
    • /
    • 2001
  • Thermal design for KOMPSAT-2 propulsion system has been performed. Overall design requirements and the constitution for propulsion system is described. To meet the thermal design requirements, both a primary and a redundant heater circuit, each with two thermostats placed in series, will protect each hydrazine-wetted components, even if one heater circuit fails to operate. Heater power is turned off if any one of these thermostats is opened at its higher setpoint. Thus, even if one thermostat is failed closed, the second thermostat will turn off the heater. All such components shall be insulated with MLI. Propulsion heater sizing based on the constant worst cold case condition is conducted through thermal analysis. All heaters selected for propulsion components operate to prevent propellant freezing satisfying the thermal requirements for the propulsion subsystem over the worst case average voltage, i.e. 25 volts.

  • PDF

페놀수지로 몰딩된 바이메탈식 서모스탯의 발화위험성 (The Hazard of Ignition on the Bimetal Type Thermostat Molded by Phenol Resin)

  • 박영국;이승훈
    • 한국화재조사학회지
    • /
    • 제11권1호
    • /
    • pp.63-73
    • /
    • 2007
  • 페놀수지로 몰딩된 바이메탈식 서모스탯의 반복적인 동작에 의한 발화위험성을 검토하기 위하여 발화된 것으로 판정된 사례의 연구와 동작 횟수를 가속시킨 실험을 행하였다. 사례연구 및 실험결과, 페놀수지로 몰딩된 바이메탈식 서모스탯(이하 '바이메탈식 서모스탯'이라 칭함)은 반복적인 동작에 의하여 내측의 고정접점과 가동접점 부분 사이에서 몰딩재료인 페놀수지가 국부적으로 탄화되는 트래킹 현상이 발생되며, 이로 인한 전기적인 발열 및 용융 등에 의하여 내측으로부터 발화될 수 있다는 사실을 입증하였다.

  • PDF

화재사례 및 재현실험을 통한 온도조절장치 고장 및 오동작으로 인한 전자제품 화재 메커니즘 분석 (A Study on the Analysis of Fire Mechanisms in Electronic Products due to Failure and Malfunction of Thermostats Through Fire Cases and Reproduction Experiments)

  • 이정일;임종화
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.31-38
    • /
    • 2024
  • In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.

The Influence of Regulatory Focus on Consumer Responses to Smart Home Services for Energy Management

  • Kim, Moon-Yong;Cho, Heayon
    • International journal of advanced smart convergence
    • /
    • 제9권3호
    • /
    • pp.221-226
    • /
    • 2020
  • Smart homes have become the state of the art in the reduction and monitoring of energy usage within a residential setting. Emerging threats such as climate change, global warming and volatility in energy prices have fuelled the interest in smart systems. Given that environmental sustainability has become a more significant factor for consumers, this research examines whether consumers' attitudes toward smart home services for efficient energy management differ according to their regulatory focus. Specifically, it is predicted that consumers will have more favorable attitudes toward smart home services for efficient energy management when they are promotion-focused (vs. prevention-focused). The results indicate that respondents with a promotion (vs. prevention) focus reported significantly more favorable attitudes toward smart home services for energy management (e.g., smart cooling/heating system, smart ventilation & air conditioning system, smart thermostats, smart plugs, and smart switches). We suggest that regulatory focus may be an effective marketing and segmentation tool in promoting smart home services for energy management and facilitating their receptiveness to the services.

PTC 써어미스터를 이용한 유속센서의 특성 (Characteristics of Flow Sensor Using PTC Thermistor)

  • 권혁주;이용현
    • 센서학회지
    • /
    • 제3권3호
    • /
    • pp.3-8
    • /
    • 1994
  • 정온발열 특성을 갖는 PTC 써어미스터를 사용하여 유속센서를 제조하였다. $(Ba_{0.7}Sr_{0.3})TiO_{3}$ 분말을 사용하여 PTC 써어미스터를 제조한 후, 유속에 따른 저항률의 변화를 조사하였다. 유속이 0 cm/s에서 5 cm/s로 변할 경우 저항률은 4.45 $k{\Omega}{\cdot}cm$에서 3.95 $k{\Omega}{\cdot}cm$로 변하였다. 유속이 1 cm/s와 5 cm/s일 경우 PTC 써어미스터의 감도는 -204 (${\Omega}{\cdot}cm$)/(cm/s)와 -24 (${\Omega}{\cdot}cm$)/(cm/s)로 나타났다.

  • PDF

SERI-RES를 이용한 Radiant Floor Heating System의 열 성능 분석 (A Thermal Performance Analysis on the Operation Modes of Radiant Floor Heating System Using SERI-RES)

  • 천원기;전명석;오정무
    • 태양에너지
    • /
    • 제11권2호
    • /
    • pp.29-33
    • /
    • 1991
  • 본 연구는 일차원 열 성능 분석 프로그램인 SERI-RES를 이용하여 우리 고유의 난방 방식이라 할 수 있는 Radiant Floor Heating System의 운전 모드(Operation Modes)에 대한 시뮬레이션을 수행하였다. SERI-RES는 원래 공기 가열식 시스템을 주요 난방 방식으로 작성된 프로그램이라 본 연구의 시뮬레이션을 수행하기 위하여 Source Code에 대한 약간의 수정을 가하였다. 얻은 결과를 분석하여 보면 Radiant Floor Heating System은 그 운용 방법(Operation Modes)에 따라 건물의 동적 열 성능에 상당한 영향을 미치는 것으로 나타났으며 이는 Test Cell에 대한 간단한 실측 실험을 통해서도 확인되었다. SERI-RES는 비록 HVAC 시스템등에 대한 구체적인 시뮬레이션은 불가하나, 비록 일차원적이기는 하지만 Radiant Floor Heating 시스템과 건물의 동적 열 성능에 대한 분석에는 상당히 효율적인 Simulation Model을 제공하였다.

  • PDF

비례제어식 자동온도조절기의 온도감지방식별 난방제어 특성 비교 (A Comparison of Heating Control Characteristics by Temperature Sensing Methods for Thermostatic Valves with the Proportional Control Mode)

  • 김용기;이태원;강성주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.161-166
    • /
    • 2007
  • Various thermostatic valves have been used widely in Korea for conservation of heating energy and enhancement of thermal comfort in residential buildings. But heating control performances of thermostatic valves extensively vary with the design and operational conditions of the heating system, climate condition and others. An experimental method was carried out in this study to analyze heating control characteristics by temperature sensing methods of thermostatic valves for various parameters, such as supply temperatures and flow rate of hot water, the position of room thermostats and outdoor air temperatures. As a result, the heat flow rate per day of S-Valve($34^{\circ}C$-Type) of water temperature sensing method was liked that of C-Valve of indoor air temperature sensing method with stage 3.3 of room thermostat in case supply temperature of hot water was $45^{\circ}C$, flow rate was 1.3 L/min and outdoor air temperature was $7.8^{\circ}C$.

  • PDF

에너지 데이터의 순위상관계수 기반 건물 내 오작동 기기 탐지 (Rank Correlation Coefficient of Energy Data for Identification of Abnormal Sensors in Buildings)

  • 김나언;정시현;장보연;김종권
    • 정보과학회 논문지
    • /
    • 제44권4호
    • /
    • pp.417-422
    • /
    • 2017
  • 비정상행위 탐지는 데이터로부터 특징을 추출하여 정상 행위 모델을 만들어, 이 정상 모델로부터 얼마나 벗어나 있는 가를 찾아내어 탐지하는 기법이다. 즉, 특정 기기가 생성하는 데이터를 기반으로 기기의 오류를 탐지하거나 사회망 데이터에서의 사용자 행위 변화를 찾아내어 비정상행위를 탐지하는 데 활용할 수 있다. 본 논문에서는 순위 상관 계수를 이용하여 건물 내의 기기의 비정상적인 데이터를 탐지하고자 한다. 에너지 절약 문제에 대한 관심이 높아짐에 따라 에너지를 효율적으로 사용하기 위해 여러방법들이 제안되었다. IT 기술의 발달과 더불어 공조 시스템(HVAC)이 건물에 도입되어 활용되고 있으며, 이 시스템을 통하여 에너지 소비의 문제점을 찾고 에너지를 효율적으로 관리할 수 있다. 따라서 본 논문은 공조 시스템에 속한 각 기기간의 순위 관계 변화를 관찰함으로써 이상 현상 탐지의 효율성을 높이는 방법을 제안하며, 사회망 데이터 내에서의 비정상행위 탐지 가능성도 함께 제안한다.