Measuring Thermo-luminescence Efficiency of TLD-2000 Detectors to Different Energy Photons

  • Xie, Wei-min;Chen, Bao-wei;Han, Yi;Yang, Zhong-Jian
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.179-183
    • /
    • 2016
  • Background: As an important detecting device, TLD is a widely used in the radiation monitoring. It is essential for us to study the property of detecting element. The aim of this study is to calculate the thermo-luminescence efficiency of TL elements. Materials and Methods: A batch of thermo-luminescence elements were irradiated by the filtered X-ray beams of average energies in the range 40-200 kVp, 662 keV $^{137}Cs$ gamma rays and then the amounts of lights were measured by the TL reader. The deposition energies in elements were calculated by theory formula and Monte Carlo simulation. The unit absorbed dose in elements by photons with different energies corresponding to the amounts of lights was calculated, which is called the thermo luminescent efficiency (${\eta}^{(E)}$). Because of the amounts of lights can be calculated by the absorbed dose in elements multiply ${\eta}^{(E)}$, the ${\eta}^{(E)}$ can be calculated by the experimental data (the amounts of lights) divided by absorbed dose. Results and Discussion: The deviation of simulation results compared with theoretical calculation results were less than 5%, so the absorbed dose in elements was calculated by simulation results in here. The change range of ${\eta}^{(E)}$ value, relative to 662 keV $^{137}Cs$ gamma rays, is about 30% in the energy range of 33 keV to 662 keV, is in accordance by the comparison with relevant foreign literatures. Conclusion: The ${\eta}^{(E)}$ values can be used for updating the amounts of lights that are got by the direct ratio assumed relations with deposition energy in TL elements, which can largely reduce the error of calculation results of the amounts of lights. These data can be used for the design of individual dosimeter which used TLD-2000 thermo-luminescence elements, also have a certain reference value for manufacturer to improve the energy-response performance of TL elements by formulation adjustment.

Geant4-DICOM Interface-based Monte Carlo Simulation to Assess Dose Distributions inside the Human Body during X-Ray Irradiation

  • Kim, Sang-Tae
    • International Journal of Contents
    • /
    • 제8권2호
    • /
    • pp.52-59
    • /
    • 2012
  • This study uses digital imaging and communications in medicine (DICOM) files acquired after CT scan to obtain the absorbed dose distribution inside the body by using the patient's actual anatomical data; uses geometry and tracking (Geant)4 as a way to obtain the accurate absorbed dose distribution inside the body. This method is easier to establish the radioprotection plan through estimating the absorbed dose distribution inside the body compared to the evaluation of absorbed dose using thermo-luminescence dosimeter (TLD) with inferior reliability and accuracy because many variables act on result values with respect to the evaluation of the patient's absorbed dose distribution in diagnostic imaging and the evaluation of absorbed dose using phantom; can contribute to improving reliability accuracy and reproducibility; it makes significance in that it can implement the actual patient's absorbed dose distribution, not just mere estimation using mathematical phantom or humanoid phantom. When comparing the absorbed dose in polymethly methacrylate (PMMA) phantom measured in metal oxide semiconductor field effect transistor (MOSFET) dosimeter for verification of Geant4 and the result of Geant4 simulation, there was $0.46{\pm}4.69%$ ($15{\times}15cm^2$), and $-0.75{\pm}5.19%$ ($20{\times}20cm^2$) difference according to the depth. This study, through the simulation by means of Geant4, suggests a new way to calculate the actual dose of radiation exposure of patients through DICOM interface.

광자극발광선량계와 열형광선량계를 이용한 핵의학과 선량 측정비교 (Comparison on the Dosimetry of TLD and OSLD Used in Nuclear Medicine)

  • 이왕희;김성철;안성민
    • 한국콘텐츠학회논문지
    • /
    • 제12권12호
    • /
    • pp.329-334
    • /
    • 2012
  • 방사선작업종사자의 개인피폭선량 측정에는 필름뱃지, 열형광선량계, 유리선량계 등이 이용되고 있었으며, 최근 들어 전 세계적으로 광자극발광선량계의 사용이 증가되고 있는 추세이다. 하지만 우리나라에서는 아직 일부에만 적용되고 있으며, 연구도 거의 없는 실정이다. 이에 기존에 가장 많이 사용되고 있던 열형광선량계와 광자극발광선량계를 핵의학과 작업종사자 및 작업구역에서 3개월간 누적선량을 비교해 보았으며, 그 결과 평균 표층선량은 열형광선량계가 1.27mSv, 광자극발광선량계가 2.12mSv로 0.85mSv의 차이가 있었으며, 평균 심부선량은 열형광선량계가 1.33mSv, 광자극발광선량계가 2.06mSv로 0.73mSv의 차이를 보였다. 광자극발광선량계가 표층선량 및 심부선량 모두에서 통계적으로 유의하게(p<0.05) 높게 측정하는 것으로 나타났다.

양성자 치료에서 생체 내 선량측정 검출기(In-vivo dosimety)의 정확성과 유용성에 관한 연구 (A Study on Accuracy and Usefulness of In-vivo Dosimetry in Proton Therapy)

  • 김선영;최재혁;원희수;홍주완;조재환;이선엽;박철수
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.171-180
    • /
    • 2014
  • 본 연구는 양성자 치료를 시행하고 있는 수모세포종 환자의 양성자 치료 시 환자들의 Skin에서 홍반이나 피부염이 발생하는 경우가 빈번하여 Phantom에서 실제 환자와 동일한 치료계획 후 생체 내 선량측정 검출기(In-vivo dosimetry)로 사용되는 열 형광선량계(Thermo-luminescence Dosimeter, TLD)와 EBT3 Film으로 실제선량을 조사 측정한다. 측정된 선량값을 치료계획 된 피부선량과 비교 분석하여 양성자 치료 시 임상적으로 피부선량 측정 사용에 유용성이 있는지 알아보고자 한다. Phantom을 수모세포종의 전뇌척수치료(Cranio-spinal irradiation, CSI) Set-up position으로 위치하여 Brain에서 부터 Pelvis까지 CT촬영하고 양성자 치료계획 후 치료실에서 디지털 영상 포지셔닝 시스템(Digital Imaging Positioning System, DIPS)을 이용하여 정확하게 치료 Isocenter지점을 맞춘다. 양성자 빔이 들어가는 5부위의 치료 Isocenter 지점과 CT촬영 시 Phantom에 표시한 Marker 2부위, 모두 7지점에 미리 교정을 마친 열 형광선량계와 EBT3 Film을 교차해가면서 위치하여 붙이고 치료 계획된 양성자 빔을 각각 10회씩 조사한다. 10회 반복 측정하여 얻은 값을 평균산출하여 치료계획 시스템 에서 측정된 Skin Dose와 비교 분석한 결과, 측정위치의 어려움이 있는 정확한 측정이 결여된 한 지점을 제외한 나머지 6지점의 측정 선량값은 열 형광선량계와 EBT3 Film 모두 절대 선량값과 ${\pm}2%$이내의 분포를 보였다. 결론적으로, 본 연구에서는 국내 최초의 양성자 치료에서 Enterance skin dose 측정을 위한 In-vivo dosimetry로 열 형광선량계와 EBT3 Film의 임상적인 유용성을 확인하였다.

여성 핵의학 방사선종사자의 관련 피폭요인 분석 (Radiation Exposure Analysis of Female Nuclear Medicine Radiation Workers)

  • 이주영;김지현;박훈희
    • 핵의학기술
    • /
    • 제21권2호
    • /
    • pp.86-93
    • /
    • 2017
  • Purpose In this study, radiation workers who work in nuclear medicine department were analyzed to find the cause of differences of radiation exposure from General Characteristic, Knowledge, Recognition and Conduct, especially females working on nuclear medicine radiation, in order to pave the way for positive defense against radiation exposure. Materials and Methods The subjects were 106 radiation workers who were divided into two groups of sixty-four males and forty-two females answered questions about their General Characteristic, Knowledge, Recognition, Conduct, and radiation exposure dose which was measured by TLD (Thermo Luminescence Dosimeter). Results The results of the analysis revealed that as the higher score of knowledge and conduct was shown, the radiation exposure decreased in female groups, and as the higher score of conduct was shown, the radiation exposure decreased in male groups. In the correlation analysis of female groups, the non-experienced in pregnancy showed decreasing amount of radiation exposure as the score of knowledge and conduct was higher and the experienced in pregnancy showed decreasing amount of radiation exposure as the score of recognition and conduct was higher. In the regression analysis on related factors of radiation exposure dose of nuclear medicine radiation workers, the gender caused the meaningful result and the amount of radiation exposure of female groups compared to male groups. In the regression analysis on related factors of radiation exposure dose of female groups, the factor of conduct showed a meaningful result and the amount of radiation exposure of the experienced in pregnancy was lower compared to the non-experienced. Conclusion The conclusion of this study revealed that radiation exposure of female groups was lower than that of male groups. Therefore, male groups need to more actively defend themselves against radiation exposure. Among the female groups, the experienced in pregnancy who have an active defense tendency showed a lower radiation exposure. Thus, those who have never been pregnant need to have a more active defensive conduct for the future possibility of pregnancy.

  • PDF

진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리 (The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System)

  • 김상우;임재동;한동균;성열훈
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

252Cf 중성자장에서 열형광선량계(TLD)를 이용한 중성자 방사선량 측정 (Neutron Dose Measurements Using TLDs in a 252Cf Neutron Field)

  • 장인수;김상인;이정일;김장렬;김봉환
    • Journal of Radiation Protection and Research
    • /
    • 제38권1호
    • /
    • pp.37-43
    • /
    • 2013
  • TLD를 이용하여 중성자 선량을 측정할 경우, TLD는 중성자 에너지에 대한 반응도 차이가 크기 때문에 현장 중성자장의 스펙트럼 특성에 맞는 에너지 반응도 보정이 반드시 필요하다. 본 실험에는 소형으로 가공된 TLD 소자를 사용하여 $^{252}Cf$ 중성자장에 설치된 내부구조가 복잡하고 좁은 Long-Counter (중성자 검출기) 내외부에서의 중성자 주위선량당량(ambient dose equivalent)을 측정하였다. 측정결과는 입자수송해석코드(MCNPX)를 이용한 계산결과와 비교하였다. 기존의 TLD 교정 선원인 $D_2O$ 감속 $^{252}Cf$만으로 교정하여 판독한 결과값은 전산모사 계산값과 많은 차이를 보였다. 그러나 bare 및 $D_2O$ 감속 $^{252}Cf$ 선원을 사용하여 생산한 두 교정인자를 혼용한 판독값은 계산값과 비슷하였다. 결과적으로, TLD 소자는 사용 현장과 비슷한 특성을 가지는 중성자장에서 교정되어야지만 올바른 선량평가가 가능함을 확인하였다.

여성 핵의학 방사선종사자의 피폭요인 분석 (Radiation Exposure Analysis of Female Nuclear Medicine Radiation Workers)

  • 이주영;박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.209-225
    • /
    • 2016
  • 본 연구는 핵의학 분야의 방사선종사자에 대해 방사선 피폭선량을 지식, 인식, 행태 및 이와 관련된 요인으로 분석하고, 특히 여성 핵의학 방사선종사자를 중심으로 피폭선량과 관련요인을 분석하고자 하였다. 핵의학과에 근무하는 방사선종사자 106명(여성 : 42명, 남성 : 64명)을 대상으로 방사선 피폭선량과 일반적 특성, 지식, 인식, 행태에 대한 설문조사를 시행하고, 분석하였다. 성별에 따른 핵의학 방사선종사자의 피폭선량을 지식, 인식, 행태 요인으로 분석한 결과, 여성 핵의학 방사선종사자에서 피폭선량과 지식 점수는 -0.221, 피폭선량과 행태 점수는 -0.512로 음의 상관관계가 있었다. 남성 핵 의학 방사선종사자는 피폭선량과 행태 점수는 -0.248로 음의 상관관계가 있었다. 임신 경험 유무에 따른 여성 핵 의학 방사선종사자의 피폭선량을 지식, 인식, 행태 요인으로 분석한 결과, 임신 경험이 없는 방사선종사자의 피폭선량과 지식 점수는 -0.238, 피폭선량과 행태 점수는 -0.511이었으며, 임신 경험이 있는 방사선종사자의 피폭선량과 인식 점수는 -0.540, 피폭선량과 행태 점수는 -0.643으로 음의 상관관계가 있었다. 핵의학 방사선종사자의 피폭선량의 관련요인에 대한 회귀분석에서 성별 요인이 가장 영향력이 있었으며, 남성에 비해 여성의 피폭선량이 3.272 mSv 낮았다. 여성 핵의학 방사선종사자의 피폭선량의 관련요인에 대한 회귀분석에서 행태 요인이 가장 영향력이 있었으며, 임신 경험이 없는 방사선종사자에 비해 임신 경험이 있는 방사선종사자의 피폭선량이 0.332 mSv 낮았다. 핵의학 방사선종사자 중 여성은 방사선 지식정도에 비례하여 행태에 반영하고 방사선 방어에 대해 실질적으로 노력하는 반면 남성은 방사선 지식을 행태적으로 거의 활용하지 않는 것으로 여겨진다. 이에 남성은 보다 적극적인 방사선 방어에 대한 교육을 통해 피폭선량 저감을 위한 활동이 요구된다. 또한 여성 핵의학 방사선종사자 중 임신 경험이 없는 방사선종사자는 방사선 방호와 관련하여 지식 정도에 비례하여 행태에 반영하지만, 임신 경험이 있는 방사선종사자는 지식 정도와는 관계없이 인식 정도가 행태에 반영되고 있으므로 이에 대해 임신 경험이 없는 방사선종사자는 방사선 방어에 대한 인식을 강화할 수 있는 방법을 모색하고, 임신 경험이 있는 방사선종사자는 지식을 강화할 수 있는 교육의 적용이 요구될 것으로 사료된다.