• 제목/요약/키워드: Thermal storage Tank

검색결과 279건 처리시간 0.137초

LNG 저장탱크용 멤브레인 형상설계를 위한 유한요소해석 (Finite Element Analysis of the Corrugated Membrane of LNG Storage Tank for Its Geometric Design)

  • 김성원;이성우;이중남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.620-624
    • /
    • 1997
  • Corrugated membranes which are used as a means of liquid- and gas-sealing for a LNG storage tank and provide one of the most reliable primary barrier are the main component of in-ground membrane types for the assurance of high safety. It absorbs large thermal and mechanical deformations caused by ultra low temperature of LNG, -162 .deg.c, the cryogenic liquid and mechanical deformations caused by was carried out on crossing corrugation by commercial F.E code, ANSYS. This paper presents some of results in stress analysis of membranes performed for the purpose to investigate the strength of existing membrane for LNG storage tank designed by IHI,MHI, KHI and KGC expect for Technigaz eariy published. Based on these analytical studies,design criteria were estabilished and SHI original membranes having a high level of safety and fitting to larger capacities were developed.

  • PDF

나선유로에 의한 태양열 축열조 성층화 촉진(제2보 시뮬레이션) (Enhancement of Stratification for Solar Water Storage Tank with Spiral Jacket and Coil(Part 2 Simulation))

  • 이성훈;손효석;홍희기
    • 설비공학논문집
    • /
    • 제26권1호
    • /
    • pp.8-14
    • /
    • 2014
  • We have performed experiments to enhance the stratification in a storage tank in order to raise the collector efficiency and solar fraction in solar thermal systems. The storage tank with a spiral jacket in the side wall has a scroll-shaped heat exchanger coil added to the upper part. The performance was compared between only the side and upper-side heating part through simulation using TRNSYS under the same weather conditions and initial conditions. As a result, the upper-side heating has a 4.2% advantage in solar fraction, but almost no increase in collector efficiency.

Transient Response of a Stratified Thermal Storage Tank to the Variation of Inlet Temperature

  • Yoo, Ho-Seon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.14-26
    • /
    • 1998
  • This paper deals with approximate analytical solutions for the two-region one-dimensional model describing the charging process of stratified thermal storage tanks at variable inlet temperature with momentum-induced mixing. An arbitrarily increasing inlet temperature is decomposed into inherent step changes and intervals of continuous change. Each continuous interval is approximated as a finite number of piecewise linear functions, which admits an analytical solution for perfectly mixed region. Using the Laplace transform, the temperature profiles in plug flow region with both the semi-infinite and adiabatic ends are successfully derived in terms of well-defined functions. The effect of end condition on the solution proves to be negligible under the practical operating conditions. For a Quadratic variation of inlet temperature, the approximate solution employing a moderate number of pieces agrees excellently with the exact solution.

  • PDF

수중 빙 제조방식을 적용한 빙축열시스템의 축방냉 특성 실험 (Experiment of Characteristic on the Charge and Discharge of Cold in Ice Storage System Applied Ice Making Method In-Water)

  • 최인수;김재돌;윤정인
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.31-37
    • /
    • 2002
  • This paper is concerned with the development of a new method for making and separating ice and saving floated ice by installing an evaporation plate at in-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating a formed ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. A new harvest-type method shows very good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, but these components are not necessary in a new method. In this study two kinds of ice storage systems are experimentally investigated to study the thermal characteristics of ice storage tanks. The results showed discharge of cold capacity of new type indicated the high values about 30~40% based on five time of drive, the temperature difference of inlet/outlet occurred the big range about $1.3^{\circ}C$. So, the new type which makes ice in water showed superiorly.

LNG 저장탱크용 KOGAS 멤브레인 개발 (The Development of KOGAS Membrane for LNG Storage Tank)

  • 오병택;김영균;윤인수;서흥석;홍성호
    • 대한기계학회논문집A
    • /
    • 제26권6호
    • /
    • pp.1203-1208
    • /
    • 2002
  • LNG demand has been rapidly increasing in Korea for a variety of reasons including stable supply, non-polluting, and high combustion efficiency characteristics. As a result the construction and expansion of LNG storage facilities have been continuing at a vigorous pace. Korea Gas Corp. (KOGAS) has developed the design technology of the LNG storage tank. One of the most important structural core element of the LNG storage tank is the membrane, made by stainless steel. The membrane to be applied inside of LNG storage tank is provided with corrugations to absorb thermal contraction and expansion caused by LNG temperature. Analytical results have been performed to investigate the strength of the membrane and the reaction farce at the anchor point. Experimental studies are performed to investigate the deformation and strength of the membrane which is designed by Kogas. All experiments are conducted on the basis of RPIS, and we found the results are fully satisfied with the RPIS.

LNG 지하저장탱크의 침투해석 및 용수 대책공법에 대한 사례분석 (Case Study on Seepage Analysis and Countermeasure Against the Seepage Flow of In-ground LNG Storage Tank)

  • 신은철;오영인;이상혁
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.65-72
    • /
    • 2001
  • Since Pyoungtaek thermal power plant began using natural gas in 1986, the annual using volume has rapidly increased and reached 12.7 million tons in 1999. When the natural gas is cooled to a temperature of approximately -162$^{\circ}$C at atmospheric pressure, it condenses to a liquid called liquefied natural gas(LNG). LNG has a special characters such as odorless, colorless, non-corrosive, and non-toxic. So, LNG storage tank, tanker ship, transfer pipelines are required the special storage and transportation systems and technology. The presently operating LNG terminals are Pyongtaek and Inchon terminals. A total of 19 above-ground LNG storage tanks(100 thousand ㎘ grade) are currently in operation with a sendout capacity of 4,360tons/hour. To meet the growing domestic demand of LNG supply, the Inchon receiving terminal is expanding(six in-ground tank) and constructing a third LNG terminal at Tongyong. In this paper, case study on seepage analysis and countermeasure against increasing the seepage volume of in-ground LNG storage tank excavation work is reported. The results of an additional seepage analysis are presented to verify the design seepage volume of assumption section and seepage volume after curtain-grouting in the slurry wall.

  • PDF

상지상식 멤브레인 액화천연가스 저장탱크의 안전성 향상 방안 (A study on the safety improvement of above ground membrane LNG storage tank)

  • 이승림;김한상
    • 에너지공학
    • /
    • 제21권4호
    • /
    • pp.339-345
    • /
    • 2012
  • 최근 안정성 및 경제성 측면에서 완전방호식 LNG 저장탱크(full-containment LNG storage tank)의 대안으로 검토되고 있는 멤브레인 LNG 저장탱크(membrane LNG storage tank)에 대해서 정량적 위험성 평가 방법(QRA; Quantitative Risk Analysis)과 유한요소해석법(FEM; Finite Element Method)을 통하여 안전성 평가를 수행하였다. 본 논문에서는 유한요소해석법(FEM)을 통한 구조안전성 평가에서 140,000 $m^3$ 저장용량을 갖는 LNG 저장탱크의 두 가지 모델은 저장탱크 시스템에 대한 강도 안전성과 누출 안전성 측면에서 해석한 결과에 의하면 모두 안전한 것으로 평가되었다. 또한, 고장수목분석(FTA; Fault Tree Analysis)을 통하여 멤브레인 LNG 저장탱크에 안전성을 강화하기 위해 설계 초기모델에 안전장치로서 멤브레인 바닥부의 충격흡수장치(impact absorber structure), 1차 멤브레인 저장 파손 시 콘크리트 외부탱크(outer tank) 코너부(corner part)의 열충격(thermal stress)을 감소시킬 수 있는 열보호장지(secondary barrier) 및 펌프 낙하 시 안전장치로서 펌프캐쳐(pump catcher)를 보완하고 평가하였다. 결론적으로 개선된 멤브레인 LNG 저장탱크는 안전성 측면에서 완전방호식 LNG 저장탱크와 대등하다는 결론을 도출할 수 있었다.

플라스틱 세포치료제 보관용기의 극저온 환경 노출 시 구조적 변화에 대한 해석적 비교 (Analytical comparison of structural changes of plastic cell-based therapeutic drug storage containers when exposed to cryogenic environments)

  • 박정연;이동목;;이순례;윤길상
    • Design & Manufacturing
    • /
    • 제14권2호
    • /
    • pp.1-6
    • /
    • 2020
  • Recently, research and commercialization related to the field of cell-based therapeutic drug development has been actively conducted. In order to maintain cell viability and prevent contamination, refrigeration preservation devices, such as CRF (controlled rate freezer) or vapor type LN2 tanks have been developed. On the other hand, the storage container for liquid nitrogen tanks currently on sale minimizes the flow structure to prevent structural defects when stored in a liquid nitrogen tank having a high thermal conductivity than vapor nitrogen. If the cell-based treatment drug is stored in the gaseous LN2 tank as it is, the cell survival after thawing is greatly reduced. It was estimated that the existing storage container structure was a factor that prevented the rapid entry and circulation of gaseous nitrogen into the container. Therefore, this study intends to propose a new supercellular storage container model that can maintain the mechanical strength while maximizing the fluid flow structure. To this end, we estimated that the structural change of the storage container effects on the equivalent stress formed around the through-holes of them when exposed to a cryogenic environment using thermal-structural coupled field analysis. As a result of storage experiments in the gas phase tank of the cell-based therapeutic agent using the developed storage container, it was confirmed that the cell growth rate was improved from 66% to 77%, which satisfied the transportation standards of the FDA(Food and Drug Administration) cell-based therapeutic agent.

고온을 받는 유황저장탱크의 열팽창에 의한 앵커볼트 영향에 관한 연구 (Study on Effect of Anchor Bolt by Thermal Expansion of Sulfur Storage Tank under High Temperature)

  • 정욱환;김정수;김태민;김문겸
    • 한국전산구조공학회논문집
    • /
    • 제29권5호
    • /
    • pp.483-490
    • /
    • 2016
  • 플랜트의 유황 저장 탱크는 강재로 구성되며, 탱크 저면은 앵커볼트에 의해 Ring Wall 형상의 콘크리트 기초와 연결된다. 탱크 내 유황이 내부 열원에 의해 고온상태를 유지하기 때문에, 유황 저장 탱크는 상온의 유체를 저장하는 다른 탱크에 비해 큰 체적팽창을 겪게 된다. 일반적으로 탱크 기초의 구조설계는 기초의 내외부의 온도차를 하중으로 적용한 구조해석이 수행되는데, 이 방법은 탱크의 열팽창 특성이 앵커볼트에 의해 집중하중 형태로 콘크리트 기초에 전달되는 현상을 고려할 수 없다. 이는 온도하중의 영향을 과소평가하게 되며, 앵커볼트에 인접한 콘크리트의 균열을 야기한다. 본 연구는 앵커볼트에 의한 온도 하중전달 메커니즘을 고려한 하중 평가식을 제안함으로써, 콘크리트 기초에 작용하는 하중을 보다 합리적으로 결정하고자 한다. 이를 위해 탱크 바닥판과 앵커볼트가 포함된 유한요소모델을 이용해 앵커볼트 개수 증감에 따른 온도하중의 변화를 분석하였으며, 분석결과를 이론해와 결합해 앵커볼트에 의해 전달되는 하중을 평가할 수 있는 명시적인 형태로 해를 제시하였다. 제안된 식의 유효성을 확인하기 위해 실제 플랜트 현장의 유황 저장 탱크 설계에 적용하였으며, 실무적으로 사용 가능함을 보였다.

시설원예용 수평형 지열히트펌프 시스템 실증연구 (A Study on Field test of the Horizontal Ground Source Heat Pump for Greenhouse)

  • 박용정;강신형
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.505-510
    • /
    • 2007
  • Greenhouses should be heated during nights and co Id days in order to fit growth conditions in greenhouses. Ground source heat pump(GSHP) or geothermal heat pump system(GHPs) is recognized to be outstanding heating and cooling system. Horizontal GSHP system is typically less expensive than vertical GSHP system but requires wide ground area to bury ground heat exchanger (GHE). In this study, a horizontal GSHP system with thermal storage tank was installed in greenhouse and investigated as performance characteristics. In the daytime, heating load of greenhouse is very small or needless because solar radiation increases inner air temperature. The results of study showed that the heating coefficient of performance of the heat pump($COP_h$) was 2.9 and the overall heating coefficient of performance of the system($COP_{sys}$) was 2.4. Heating energy cost was saved 76% using the horizontal GSHP system with thermal storage tank.

  • PDF