• 제목/요약/키워드: Thermal probe

검색결과 337건 처리시간 0.029초

MEMS 공정을 이용한 32x32 실리콘 캔틸레버 어레이 제작 및 특성 평가 (Fabrication and Characterization of 32x32 Silicon Cantilever Array using MEMS Process)

  • 김영식;나기열;신윤수;박근형;김영석
    • 한국전기전자재료학회논문지
    • /
    • 제19권10호
    • /
    • pp.894-900
    • /
    • 2006
  • This paper reports the fabrication and characterization of $32{\times}32$ thermal cantilever array for nano-scaled memory device applications. The $32{\times}32$ thermal cantilever array with integrated tip heater has been fabricated with micro-electro-mechanical systems(MEMS) technology on silicon on insulator(SOI) wafer using 9 photo masking steps. All of single-level cantilevers(1,024 bits) have a p-n junction diode in order to eliminate any electrical cross-talk between adjacent cantilevers. Nonlinear electrical characteristic of fabricated thermal cantilever shows its own thermal heating mechanism. In addition, n-channel high-voltage MOSFET device is integrated on a wafer for embedding driver circuitry.

Fabrication of A chemical Thermal Probe

  • Jung, Mi-Young;Choi, Seong-Soo;Kang, C.J.;Suh, Y.D.;Kuk, Young
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1997년도 제12회 학술발표회 논문개요집
    • /
    • pp.152-153
    • /
    • 1997
  • PDF

박막 접합 형성을 위한 열처리 방법에 관한 연구 ((A Study on the Annealing Methods for the Formation of Shallow Junctions))

  • 한명석;김재영;이충근;홍신남
    • 대한전자공학회논문지TE
    • /
    • 제39권1호
    • /
    • pp.31-36
    • /
    • 2002
  • 낮은 에너지의 보론 이온을 선비정질화된 실리콘 기판과 단결정 기판에 이온 주입하여 0.2μm 정도의 접합 깊이를 갖는 박막의 P/sup +/-n 접합을 형성하였다 이온주입에 의한 결정결함의 제거 및 주입된 보론 이온의 활성화를 위해 급속 열처리기를 이용하였으며, BPSC(bore-phosphosilicate glass)를 흐르도록 하기 위해 노 열처리를 도입하였다. 선비정질화 이온주입은 45keV, 3×10/sup 14/cm/sup -2/ Ge 이온을 사용하였으며, p형 불순물로는 BF2 이온을 20keV, 2×10/sup 15/cm /sup -2/로 이온주입 하였다. 급속 열처리와 노 열처리 조건은 각각 1000。C/ 10초와 850。C/4O분이었다. 형성된 접합의 접합깊이는 SIMS와 ASR로 측정하였으며, 4-point probe로 면 저항을 측정하였다. 또한 전기적인 특성은 다이오드에 역방향 전압을 인가하여 측정된 누설전류로 분석하였다. 측정 결과를 살펴보면, 급속 열처리만을 수행하여도 양호한 접합 특성을 나타내나, 급속 열처리와 노 열처리를 함께 고려해야 할 경우에는 노 열처리 후에 급속 열처리를 수행하는 공정이 급속 열처리 후에 노 열처리를 수행하는 경우보다 더 우수한 박막 접합 특성을 나타내었다.

마이크로 프로브 기반 열전 센서 제작 기술 (Fabrication of a Micro-thermoelectric Probe)

  • 장원석;최태열
    • 대한기계학회논문집B
    • /
    • 제35권11호
    • /
    • pp.1133-1137
    • /
    • 2011
  • 마이크로 수준에서의 온도측정을 위하여 유리 피펫 기반의 프로브형 온도센서를 제작하였다. 이를 이용하여 정밀도 ${\pm}$ 0.1 K 를 가지는 온도측정 보정 실험을 수행하였다. 본 연구에서 제작한 방식은 저온의 용융점을 갖는 솔더합금(Sn)을 피펫에 내부에 주입하고 외부에 니켈(Ni) 코팅을 하여 열전대를제작함으로써 저비용의 프로브형 온도센서를 구현하였다. 제작된 센서 팁 끝단의 지름은 5 Am 에서 30 Am 로 피펫을 가열하여 당기는 방식으로 프로브 끝단의 크기를 조절하였다. 제작된 온도센서는 챔버내에서 정밀하게 제어된 온도 조절기를 사용하여 보정하였으며, 이를 통하여 얻어진 열전계수의 범위는 8.46 에서 $8.86{\mu}V$/K 의 값을 얻었다. 이를 이용하면 MEMS 소자, 세포, 티슈 등의 바이오 소재의 온도 및 열특성 측정용 프로브로 활용할 수 있을 것으로 생각된다.

열차폐코팅의 비파괴적 손상 평가를 위한 고감도 와전류 센서 설계 (Designing a Highly Sensitive Eddy Current Sensor for Evaluating Damage on Thermal Barrier Coating)

  • 김종민;이슬기;김학준;송성진;석창성;이영제
    • 비파괴검사학회지
    • /
    • 제36권3호
    • /
    • pp.202-210
    • /
    • 2016
  • 열차폐코팅은 극한의 열환경에서 사용되는 기계요소를 고온으로부터 보호하기 위하여 널리 이용하는 코팅으로, 관련 산업의 경제적 이윤과 사용자 안전에 관련한 중요한 기술이다. 따라서 이런 열차폐코팅의 비파괴적 손상 평가는 그 중요성이 높이 평가되어 왔으나, 코팅 파쇄의 원인이 되는 내부의 미세한 조성 변화를 감지하기 위한 기술적 난제를 안고 있는 연구 주제이다. 본 논문은 열차폐코팅의 비파괴적 손상 평가를 위한 유한요소해석 기반 고감도 와전류 센서 설계 과정을 소개하고, 설계한 센서를 제작하여 진행한 성능 평가를 통해 설계 과정을 검증하였다. 와전류 센서의 성능을 예측하기 위하여 유한요소해석을 수행한 결과, 열차폐코팅의 손상 정도에 따른 센서의 임피던스가 증가와, 마그네틱 쉴드를 적용하였을 때 자속집속에 의한 검출능 향상을 관찰할 수 있었다. 또한 실제 실험결과와 비교를 통해 유한요소해석 결과를 검증하였다.

루테늄 삽입층에 의한 니켈모노실리사이드의 안정화 (Thermal Stability of Ru-inserted Nickel Monosilicides)

  • 윤기정;송오성
    • 대한금속재료학회지
    • /
    • 제46권3호
    • /
    • pp.159-168
    • /
    • 2008
  • Thermally-evaporated 10 nm-Ni/1 nm-Ru/(30 nm or 70 nm-poly)Si structures were fabricated in order to investigate the thermal stability of Ru-inserted nickel monosilicide. The silicide samples underwent rapid thermal anne aling at $300{\sim}1,100^{\circ}C$ for 40 seconds. Silicides suitable for the salicide process were formed on the top of the single crystal and polycrystalline silicon substrates mimicking actives and gates. The sheet resistance was measured using a four-point probe. High resolution X-ray diffraction and Auger depth profiling were used for phase and chemical composition analysis, respectively. Transmission electron microscope and scanning probe microscope(SPM) were used to determine the cross-sectional structure and surface roughness. The silicide, which formed on single crystal silicon and 30 nm polysilicon substrate, could defer the transformation of $Ni_2Si $i and $NiSi_2 $, and was stable at temperatures up to $1,100^{\circ}C$ and $1,100^{\circ}C$, respectively. Regarding microstructure, the nano-size NiSi preferred phase was observed on single crystalline Si substrate, and agglomerate phase was shown on 30 nm-thick polycrystalline Si substrate, respectively. The silicide, formed on 70 nm polysilicon substrate, showed high resistance at temperatures >$700^{\circ}C$ caused by mixed microstructure. Through SPM analysis, we confirmed that the surface roughness increased abruptly on single crystal Si substrate while not changed on polycrystalline substrate. The Ru-inserted nickel monosilicide could maintain a low resistance in wide temperature range and is considered suitable for the nano-thick silicide process.

증례보고: MRI 검사시 귓불에 부착한 산소측정기로 인해 발생한 전층 화상 (MRI-Induced Full Thickness Burn on the Ear Lobule due to Pulse Oximetry: A Case Report)

  • 김범식;임수아;윤정수;어수락;한예식
    • 대한화상학회지
    • /
    • 제24권2호
    • /
    • pp.43-45
    • /
    • 2021
  • Magnetic Resonance Image (MRI) has been used as a safe, conventional and harmless diagnostic tool. However, thermal injuries have frequently been reported during MRI scanning due to the heat generated by the reaction with the magnetic field. It is recommended that metal-containing monitoring devices such as pulse oximetry and ECG monitoring leads should be removed prior to the start of the MRI scan, but these monitoring devices are inevitably placed in children or patients in the intensive care unit who have low compliance with the scan. Since the interaction between the metal probe or wire loop of pulse oximetry and the magnetic field can result in high thermal conduction, full-thickness burn can occur over the entire body surface during the MRI examination. Several cases of thermal burns from pulse oximetry on the fingers have been reported. However, we present a case of a full-thickness burn arising left earlobe in a 2-month-old child caused by the high conduction heat from pulse oximetry metal probe.

용사법에 의한 Al/Al-SiC 복합재료의 제조 (Fabrication of Al/Al-SiC Composites by Thermal Spray Process)

  • 김균택;김영식
    • 동력기계공학회지
    • /
    • 제10권2호
    • /
    • pp.93-98
    • /
    • 2006
  • Metal matrix composites(MMCs) reinforced with ceramic particulates are receiving increasing attention because their high specific strength, low coefficient of thermal expansion and excellent wear resistance. Especially, Al-based composites(AMCs) have been widely applied for the aerospace and automotive industries. Such composites are mainly fabricated by the cast, powder metallurgy and infiltration process. In this study, SiC particulate reinforced Al-based composites were fabricated by thermal spray process and their wear behavior were investigated. Composites with different spray parameter were fabricated by using flame spray apparatus. Microstructure and wear behavior of the composites were observed by scanning electron microscope(SEM) and electron probe micro-analysis(EPMA).

  • PDF

광열변위의 위상차를 이용한 불투명 고체의 열확산계수 측정 (Thermal diffusivity measurements of opaque solid using the phase lag of photothermal displacement.)

  • 이은호;이광재;전필수;유재석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.138-143
    • /
    • 2000
  • A new method of measuring the thermal diffusivity of solid material at room temperature with photothermal displacement method is proposed. The influence of the parameters on phase lag was studied. From the minimum position of phase of measured deflection with respect to the pump beam the thermal diffusivity of the materials can be obtained. The minimum position of phase is determined using multiparameter least-square regression fitting. The experimental values for different samples obtained by applying new method are in good agreement with the literature values.

  • PDF

CNC 공작기계의 열변형 오차 보정 (II) - PC-NC제어기용 오차보정 알고리즘 분석 - (Compensation of Thermal Errors for the CNC Machine Tools (II) - Analysis of Error Compensation Algorithm for the PC-NC Controller -)

  • 이재종;최대봉;박현구
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.214-219
    • /
    • 2001
  • One of the major limitations of productivity and quality in metal cutting is the machining accuracy of machine tools. The machining accuracy is affected by geometric errors, thermally-induced errors, and the deterioration of the machine tools. Geometric and thermal errors of machine tools should be measured and compensated to manufacture high quality products. In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. In this study, the compensation device and temperature-based algorithm have been presented in order to compensate thermal error of machine tools under the real-time. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses, a designed spherical ball artifact, and five gap sensors. In order to compensate thermal characteristics under several operating conditions, experiments performed with five gap sensors and manufactured compensation device on the horizontal machining center.

  • PDF