• 제목/요약/키워드: Thermal plume

검색결과 106건 처리시간 0.028초

한국형 발사체 기저부 열전달 해석을 위한 플룸 복사 모델링 개념 개발 (A Development of Thermal Radiation Plume Modelling for Heat Transfer to KSLV-II Engine Base)

  • 김성룡;고주용;김인선
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.507-514
    • /
    • 2012
  • 한국형 발사체의 플룸 형상과 플룸 복사열 해석을 위해 NASA LRB 플룸 복사 모델을 구현하였으며 열해석 소프트웨어인 Thermal Desktop에서 형상화하여 실제 복사 열전달을 계산하여 NASA 예측결과와 비교하였다. 계산 결과 NASA 예측과 비슷한 수준의 정확도를 나타냈으며 한국형 발사체에 적용 가능한 수준의 플룸 모델 형상을 제안하였다.

  • PDF

Detection of Thermal Plume Signature in and around the Younggwang coastal waters of Korea using LANDSAT & NOAA Thermal Infrared Data

  • Ahn, Yu-Hwan;Shanmugam, P.;Lee, Jae-Hak;Kang, Yong Q.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.869-872
    • /
    • 2003
  • The thermal contamination of the Younggwang coastal marine ecosystem has been investigated using space borne thermal infrared data acquired over the period 1985-2003 by the Landsat and NOAA satellites. The analysis of AVHRR data brought out the general pattern and extension of thermal plume while TM data yielded more accurate information about the plume shape, dimension, dispersion direction etc. The examination of sea surface temperature (SST) computed from these images clearly indicates that the thermal plume extends 70 to100km southward during summer and 50 to70km northwestward during winter monsoons. The maximum plume temperature was 29$^{\circ}C$ in summer and 12$^{\circ}C$ in winter. The comparative analysis shows that the temperature retrieved from TM is slightly higher (1.8$^{\circ}C$, 3$^{\circ}C$ and 2.2$^{\circ}C$ for the images of 98/11/10, 99/05/05 and 99/05/21 respectively) than those derived from AVHRR data. The correlation coefficient between the TM-derived SST and AVHRR-derived SST was 0.72.

  • PDF

플륨 모니터링에 의한 SM45C 레이저 용접특성 평가 (Estimation of Laser Welding Behavior of SM45C Steels by Plume Monitoring)

  • 유영태;김재열;노경보;양동조;오용석;임기건;김지환
    • 한국공작기계학회논문집
    • /
    • 제12권6호
    • /
    • pp.14-21
    • /
    • 2003
  • With the increased use of lasers in industrial welding applications, techniques for monitoring and controlling these processes become increasingly important. It is very important that we understand the dynamic behaviors of the laser induced Plume in welding, because the laser induced plume has considerable effects on welding efficiency and the quality of materials. As the plume fluctuation was associated with keyhole instability, unstable vapor plume indicated the process was unstable and would result in poor welds. An Infrared Thermal-vision Camera can be utilized compensate for incurracies encountered in real-time monitoring during laser welding. We have results that instabilities of plume are closely related with hot cracking and defect of laser welding.

산불에 의한 열적상승유동 해석에 관한 연구 (A Study on the model of Thermal Plume Flow in the Forest Fire)

  • 지영무;박준상
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.358-361
    • /
    • 2008
  • A study is made of thermal plume flow model for the development of helicopter simulator over the forest fire. For numerical analysis, the Boussinesq fluid approximation and line fire model, which is assumed by the shape of forest fire spreading, are adopted. Comparing 3-D full numerical solutions with 2-D similarity solution, it has been built a new model that is capable of temperature prediction along the symmetric vertical axis in both cases of laminar and turbulent flows.

  • PDF

지하수류가 대수층 열저장 시스템의 성능에 미치는 영향(3) (The Influence of Groundwater Flow on the Performance of an Aquifer Thermal Energy Storage (ATES) System)

  • 한정상;이주현;김영식;이광진;홍경식
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권4호
    • /
    • pp.9-26
    • /
    • 2017
  • When a warm well located downgradient is captured by cold thermal plume originated from an upgradient cold well, the warm thermal plume is pushed further downgradient in the direction of groundwater flow. If groundwater flow direction is parallel to an aquifer thermal energy storage (ATES), the warm well can no longer be utilized as a heat source during the winter season because of the reduced heat capacity of the warm groundwater. It has been found that when the specific discharge is increased by $1{\times}10^{-7}m/s$ in this situation, the performance of ATES is decreased by approximately 2.9% in the warm thermal plume, and approximately 6.5% in the cold thermal plume. An increase of the specific discharge in a permeable hydrogeothermal system with a relatively large hydraulic gradient creates serious thermal interferences between warm and cold thermal plumes. Therefore, an area comprising a permeable aquifer system with large hydraulic gradient should not be used for ATES site. In case of ATES located perpendicular to groundwater flow, when the specific discharge is increased by $1{\times}10^{-7}m/s$ in the warm thermal plume, the performance of ATES is decreased by about 2.5%. This is 13.8% less reduced performance than the parallel case, indicating that an increase of groundwater flow tends to decrease the thermal interference between cold and warm wells. The system performance of ATES that is perpendicular to groundwater flow is much better than that of parallel ATES.

Effect of Flue Gas Heat Recovery on Plume Formation and Dispersion

  • Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • 한국입자에어로졸학회지
    • /
    • 제8권4호
    • /
    • pp.161-172
    • /
    • 2012
  • Three-dimensional numerical simulation using a computational fluid dynamics (CFD) was carried out in order to investigate the formation and dispersion of the plume discharged from the stack of a thermal power station. The simulation was based on the standard ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite-volume method. Warm and moist exhaust from a power plant stack forms a visible plume as entering the cold ambient air. In the simulation, moisture content, emission velocity and temperature of the flue gas, air temperature and wind speed were dealt with the main parameters to analyze the properties of the plume composed mainly of water vapor. As a result of the simulation, the plume could be more apparent in cold winter due to a big difference of latent heat capacity. At no wind condition, the white plume rises 120 m upward from the top of the stack, and expands to 40 m around from the stack in cold winter after flue gas heat recovery. The influencing distance of relative humidity will be about 100 m to 400 m downstream from the stack with a cross wind effect. The decrease of flue gas temperature by heat recovery of thermal energy facilitates the formation of the plume and restrains its dispersion. Wind speed with vertical distribution affects the plume dispersion as well as the density.

형상 계수를 이용한 알루미나 입자구름의 열복사 예측 기법 연구 (A Study of Thermal Radiation from The Alumina Particle Cloud in The Plume Using View Factor Method)

  • 고주용;김인선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2044-2049
    • /
    • 2007
  • In order to predict the thermal radiation induced from alumina particle cloud in the plume of solid propellant motor, view factor method is applied to space shuttle SRB and the result is compared with that of monte carlo method. For this purpose, radiative characteristics, such as particle cloud temperature distribution, effective emissivity or emissive power of particle cloud are studied. In the case of effective emissivity, inverse wavelength method is applied and plume reduction characteristic length is used for emissive power distribution. As a result, thermal radiation using view factor method gives more conservative results than that using monte carlo method. So it can be used for preliminary design of thermal protection system.

  • PDF

유한체적법에 의한 로켓플룸 저부가열의 열복사 모델 (Thermal radiation model for rocket plume base heating using the finite-volume method)

  • 김만영;백승욱
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3598-3606
    • /
    • 1996
  • The finite volume method for radiation is applied to investigate a radiative heating of rocket base plane due to searchlight and plume emissions. Exhaust plume is assumed to absorb, emit and scatter the radiant energy isotropically as well as anisotropically, while the medium between plume boundary and base plane is cold and nonparticipating. Scattering phase function is modelled by a finite series of Legendre polynomials. After validating benchmark solution by comparison with that of previous works obtained by the Monte-Carlo method, further investigations have been done by changing such various parameters as plume cone angle, scattering albedo, scattering phase function, optical radius and nozzle exit temperature. The results show that the base plane is predominantly heated by the plume emission rather than the searchlight emission when the nozzle exit temperature is the same as that of plume.

화학 평형과 열복사를 포함한 로켓 플룸 유동 해석 (Numerical Analysis of Rocket Exhaust Plume with Equilibrium Chemistry and Thermal Radiation)

  • 신재렬;최정열;최환석
    • 한국추진공학회지
    • /
    • 제9권1호
    • /
    • pp.35-45
    • /
    • 2005
  • 여러 고도에서 화학 반응과 열복사 효과가 로켓 플룸 유동에 미치는 영향을 살피기 위한 수치 연구를 수행하였다. 압축성 유동의 Navier-Stokes 방정식을 유한 체적법에 근거한 완전 내재적 TVD코드로 해석하였으며, 탄화수소 혼합물의 자세한 열화학적 속성을 고려한 화학 평형과 광학적으로 두꺼운 매체의 열복사를 유동 해석 코드에 포함하였다. 지상 마하수 0, 고도 5.06 km에서 마하수 1.16 그리고 17.34 km에서 마하수 2.90로 비행하는 등유 연료 로켓의 플룸 유동을 해석하였다. 해석 결과는 서로 다른 고도 조건에서의 플룸의 구조와 함께 화학 반응과 복사의 영향을 보여 주었다. 추진 성능과 기저부 열차단의 측면에서, 화학 반응에 의한 배출가스의 온도 상승은 특히 고고도에서 무시할 수 없음을 알 수 있었다.

평형화학반응과 복사열전달을 고려한 로켓 플룸 유동 해석 (Numerical Study of Rocket Exhaust Plume with Equilibrium Chemical Reaction and Thermal Radiation)

  • 신재렬;최정열;최환석
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.146-153
    • /
    • 2004
  • The Numerical study has been carried out to investigate the effects of chemical reaction and thermal radiation on the rocket plume flow-field at various altitudes. The theoretical formulation is based on the Navier-Stokes equations for compressible flows along with the infinitely fast chemistry and thermal radiation. The governing equations were solved by a finite volume fully-implicit TVD(Total Variation Diminishing) code which uses Roe's approximate Riemann solver and MUSCL(Monotone Upstream-centered Schemes for Conservation Laws) scheme. LU-SGS (Lower Upper Symmetric Gauss Seidel) method is used for the implicit solution strategy. An equilibrium chemistry module for hydrocarbon mixture with detailed thermo-chemical properties and a thermal radiation module for optically thin media were incorporated with the fluid dynamics code. In this study, kerosene-fueled rocket was assumed operating at O/F ratio of 2.34 with a nozzle expansion ratio of 6.14. Flight conditions considered were Mach number zero at ground level, Mach number 1.16 at altitude 5.06km and Mach number 2.9 at altitude 17.34km. Numerical results gave the understandings on the detailed plume structures at different altitude conditions. The diffusive effect of the thermal radiation on temperature field and the effect of chemical recombination during the expansion process could be also understood. By comparing the results from frozen flow and infinitely fast chemistry assumptions, the excess temperature of the exhaust gas resulting from the chemical recombination seems to be significant and cannot be neglected in the view point of performance, thermal protection and flow physics.

  • PDF