• 제목/요약/키워드: Thermal force

검색결과 908건 처리시간 0.032초

Fiber-reinforced micropolar thermoelastic rotating Solid with voids and two-temperature in the context of memory-dependent derivative

  • Alharbi, Amnah M.;Said, Samia M.;Abd-Elaziz, Elsayed M.;Othman, Mohamed I.A.
    • Geomechanics and Engineering
    • /
    • 제28권4호
    • /
    • pp.347-358
    • /
    • 2022
  • The main concern of this article is to discuss the problem of a two-temperature fiber-reinforced micropolar thermoelastic medium with voids under the effect rotation, mechanical force in the context four different theories with memory-dependent derivative (MDD) and variable thermal conductivity. The three-phase-lag model (3PHL), dual-phase-lag model (DPL), Green-Naghdi theory (G-N II, G-N III), coupled theory, and the Lord-Shulman theory (L-S) are employed to solve the present problem. Analytical expressions of the physical quantities are obtained by using Laplace-Fourier transforms technique. Numerical results are shown graphically and the results obtained are analyzed. The most significant points are highlighted.

Effects of Microgravity on Human Physiology

  • Nguyen, Nguyen;Kim, Gyutae;Kim, Kyu-Sung
    • Korean journal of aerospace and environmental medicine
    • /
    • 제30권1호
    • /
    • pp.25-29
    • /
    • 2020
  • Space exploration is one of the dreams of humankind. However, the intriguing environment was a challenge for the human body, where we must counter with many extreme conditions such as thermal support, radiation, microgravity. Life, as well as the human body, developed and evolved in the continuous presence of gravity, especially when living creatures transfer from the ocean to the land. Once this gravitational force doesn't impact on the body, the drastic changes occur. Some of these changes were observed immediately, while others progress only slowly. Since the first orbital flight was performed, several hazards for the organs of the human body were identified [1]. These changes in human physiology can reverse when astronauts return to Earth. This article will review the published findings of the effects of microgravity exposure on the human body.

Mechanical Properties of Epoxy Paints Containing Oxidized Graphene Nanoplatelet (산화 그래핀 나노플레이트릿을 혼입한 에폭시 도료의 역학적 특성)

  • Seo, Won-Woo;Kim, Gyu-Yong;Yoon, Min-Ho;Hwang, Eui Chul;Baek, Jae Uk;Nam, Jeong Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.153-154
    • /
    • 2017
  • Graphene is a nanomaterial and is known to have very high mechanical strength, thermal and electrical properties. However, graphene is known to be difficult to disperse among carbon-based materials due to van der Waals force. In this study, to solve the dispersion problem of graphene nanoplatelet, oxidized graphene nanoplatelet was prepared by oxidizing GNP in nitric acid. The prepared GO was dispersed in ethanol and distilled water before incorporation into the epoxy paint to confirm dispersibility. In addition, GNP/Epoxy and GO/Epoxy tensile specimens were prepared by mixing GNP and GO at 0.1, 0.3, 0.5 and 1.0 wt.% In epoxy coatings and tensile stress-strain characteristics were investigated.

  • PDF

Influence of gravity, locality, and rotation on thermoelastic half-space via dual model

  • Samia M. Said
    • Structural Engineering and Mechanics
    • /
    • 제89권4호
    • /
    • pp.375-381
    • /
    • 2024
  • In this paper, Eringen's nonlocal thermoelasticity is constructed to study wave propagation in a rotating two-temperature thermoelastic half-space. The problem is applied in the context of the dual-phase-lag (Dual) model, coupled theory (CD), and Lord-Shulman (L-S) theory. Using suitable non-dimensional fields, the harmonic wave analysis is used to solve the problem. Comparisons are carried with the numerical values predicted in the absence and presence of the gravity field, a nonlocal parameter as well as rotation. The present study is valuable for the analysis of nonlocal thermoelastic problems under the influence of the gravity field, mechanical force, and rotation.

Development of the Structure for Enhancing Capillary Force of the Thin Flat Heat Pipe Based on Extrusion Fabrication (압출형 박판 히트파이프의 모세관력 향상을 위한 구조 개발)

  • Moon, Seok Hwan;Park, Yoon Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제40권11호
    • /
    • pp.755-759
    • /
    • 2016
  • The use of heat pipes in the electronic telecommunication field is increasing. Among the various types of heat pipes, the thin flat heat pipe has relatively high applicability compared with the circular heat pipe in the electronic packaging application. The thin flat heat pipe based on extrusion fabrication has a simple capillary wick structure consisting of rectangular cross sectional grooves on the inner wall of the pipe. Although the groove serves as a simple capillary wick, and many such grooves are provided on the inner wall, it is difficult for the grooves to realize a sufficiently high capillary force. In the present study, a thin flat heat pipe with a wire bundle was developed to overcome the drawback of poor capillary force in the thin flat heat pipe with grooves, and was evaluated by conducting tests. In the performance test, the thin flat heat pipe with the wire bundle showed a lower thermal resistance of approximately 3.4 times, and a higher heat transfer rate of approximately 3.8 times with respect to the thin flat heat pipe with grooves as the capillary wick respectively. The possibility of using the wire bundle as a capillary wick in the heat pipe was validated in the present study; further study for commercializing this concept will be taken up in the future.

Surface Modification of Polystyrene (PS) by Atmospheric Pressure Plasma (상압 플라즈마를 이용한 Polystyrene (PS)의 표면개절)

  • Lee, Jong-Su;Shin, Hyun-Seok;Seok, Jin-Woo;Jang, Gyu-Wan;Beag, Yeong-Hwan
    • Journal of the Korean Vacuum Society
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2009
  • Hydrophilic Surface modification of Polysarene (PS) was performed by Atmospheric Pressure Plasma (APP). Air or 0, gases were used for carrier gases and RF power was changed from 150 to 350 W. We controlled the treatment time as 1 time to 4 time passing through the plasma region. when the carrier gas was air, the water contact angle on the PS surface was decreased from $91^{\circ}$ to $20^{\circ}$. And the surface energy increased from 45.74 dyne/cm to 68.48 dyne/cm. In case of the $O_2$ plasma treatment, at 300 W of RF power and 4 times treatment, the water contact angle on the PS. Surface was decreased from $91^{\circ}$ to $17^{\circ}$ and the surface energy was increased from 45.74 dyne/cm to 69.73 dyne/cm. The surface energy was increased by polar force not by dispersion force. Improvement of surface properties can be explained by the formation of new hydrophilic groups which is identified as C-O, C=O by XPS analysis. The contact angle of APP treated PS surface kept in air was increased with time elapse, but maintained same value when it was kept in water. We treated the PS surface by APP and deposited Cu as $4,000\;{\AA}$ and $8,000\;{\AA}$ by thermal evaporation. The adhesion between sample and Cu thin film improvement of treated PS surface against untreated sample. could be verifiable by Tape test (ASTM D3359)

Thermal-Hydraulic Analysis and Parametric Study on the Spent Fuel Pool Storage (기사용 핵연료 저장조에 대한 열수력 해석 및 관련 인자의 영향 평가)

  • Lee, Kye-Bock;Nam, Ki-Il;Park, Jong-Ryul;Lee, Sang-Keun
    • Nuclear Engineering and Technology
    • /
    • 제26권1호
    • /
    • pp.19-31
    • /
    • 1994
  • The objective of this study is to conduct a thermal-hydraulic analysis on the spent fuel pool and to evaluate a parametric effect for the thermal-hydraulic analysis of spent fuel pool. The selected parameters are the Reynolds Number and the gap flow through the oater gap between fuel cell and fuel bundle. The simplified flow network for a path of fuel cells is used to analyze the natural circulation phenomenon. In the flow network analysis, the pressure drop for each assembly from the entrance of the fuel rack to the exit of the fuel assembly is balanced by the driving head due to the density difference between the pool fluid and the average fluid in each spent fuel assembly. The governing equations ore developed using this relation. But, since the parameters(flow rate, pressure loss coefficient, decay heat, density)are coupled each other, iteration method is used to obtain the solution. For the analysis of the YGN 3&4 spent fuel rack, 12 channels are considered and the inputs such as decay heat and pressure loss coefficient are determined conservatively. The results show the thermal-hydraulic characteristics(void fraction, density, boiling height)of the YGN 3&4 spent fuel rack. There occurs small amount of boiling in the cells. Fuel cladding temperature is lower than 343.3$^{\circ}C$. The evaluation of parametric effect indicates that flow resistances by geometric effect are very sensitive to Reynolds number in the transition region and the gap flow is negligible because of the larger flow resistance in the gap flow path than in the fuel bundle.

  • PDF

Thermal Behavior and Structral Efficiency of Rahmen with Sliding-Girder (슬라이딩 거더를 가진 라멘의 온도거동과 구조효율)

  • Jeong, Dal-Yeong;Jeong, Chang-Hyun;Yhim, Sung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제21권1호
    • /
    • pp.1-7
    • /
    • 2020
  • Although the temperature load is an important load among the various loads affecting the behaviors of general rahmen-type temporary bridges (GRTB), no study of the thermal load has been carried out. In the case of GRTB, horizontal displacement should be free, and the generated internal force should be minimized to reduce stress due to a temperature load. Sliding girder type bridge (SGTB) allows the axial deformation due to thermal load, and decreases the axial stress and delivers bending stress. This study examined the temperature behavior of an SGTB. Structural analysis was carried out for four types of spans (eq, 10, 20, 30, and 40m) and three types of pier heights (eq, 2, 4, and 6m) along with the GRTB. The applied loads were a fixed vertical load and an axial temperature load. The friction coefficient was 0.4, which is a representative value of a steel girder. Consequently, the stress of the SGTB increased with increasing span length, regardless of the temperature load. The stress of the GRTB increased with increasing temperature and span length. Compared to the GRTB, the stress of the SGTB decreased by 20% to 50% at the center of the girder and by 50% to 90% at the bottom of the pier. This could secure the structural efficiency compared to the GRTB with the same specifications.

Study for Characteristic of Frictional Heat Transfer in Rotating Brake System (회전을 고려한 브레이크 디스크의 마찰열전달 연구)

  • Nam, Jiwoo;Ryou, Hong Sun;Cho, Seong Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제18권10호
    • /
    • pp.817-822
    • /
    • 2017
  • The braking system is one of the most important components in vehicles and machines. It must exert a reliable braking force when they are brought to a halt. Generally, frictional heat is generated by converting kinetic energy into heat energy through friction. As the kinetic energy is converted into heat energy, high temperature heat is generated which affects the mechanical behavior of the braking system. Frictional heat affects the thermal expansion and friction coefficient of the brake system. If the temperature is not controlled, the brake performance will be decreased. Therefore, it is important to predict and control the heat generation of the brake. Various numerical analysis studies have been carried out to predict the frictional heat, but they assumed the existence of boundary conditions in the numerical analysis to simulate the frictional heat, because the simulation of frictional heat is difficult and time consuming. The results were based on the assumption that the frictional heat is different from the actual temperature distribution in a rotating brake system. Therefore, the reliability of the cooling effect or thermal stress using the results of these studies is insufficient. In order to overcome these limitations and establish a simulation procedure to predict the frictional heat, this study directly simulates the frictional heat generation by using a thermal-structure coupling element. In this study, we analyzed the thermo-mechanical behavior of a brake model, in order to investigate the thermal characteristics of brake systems by using the Finite Element method (FEM). This study suggests the necessity to directly simulate the frictional heating and it is hoped that it can provide the necessary information for simulations.

Evaluation on Mechanical Properties of High Strength Light-Weight Concrete with Elevated Temperature and loading (하중조건과 고온에 의한 고강도 경량 콘크리트의 역학적 특성 평가)

  • Kim, Gyu-Yong;Kim, Young-Sun;Choe, Gyeong-Cheol;Park, Hyun-Gil;Lee, Tae-Gyu
    • Journal of the Korea Concrete Institute
    • /
    • 제23권6호
    • /
    • pp.723-730
    • /
    • 2011
  • It is very important to experimentally evaluate concrete behavior at elevated temperature because aggregates make up approximately 80 percent of volume in concrete. In this study, an experiment to evaluate mechanical properties of normal weight and light weight concrete of 60 MPa was conducted. Based on loading level of 0, 20 and 40 percent, the tests of 28 days compressive strength, elastic modulus, thermal strain, total strain, and transient creep using ${\phi}100{\times}200mm$ cylindrical specimens at elevated temperature were performed. Then, the results were compared with CEB (Committes Euro-international du Beton) model code. The results showed that thermal strain of light weight concrete was smaller than normal weight concrete. Also, the results showed that compressive strength of light concrete at $700^{\circ}C$ was higher than normal weight concrete and CEB code, similar to that obtained at ambient temperature. Transient creep developed from loading at a critical temperature of $500^{\circ}C$ caused the concrete strains to change from expansion to compression. The transient creep test result showed that internal force was high when the ratio of shrinkage between concrete and aggregate was more influential than thermal expansion.