• 제목/요약/키워드: Thermal energy performance

검색결과 1,938건 처리시간 0.032초

진공관형 태양열 집열기의 흡수관 형상 변화에 따른 성능 비교 (Performance comparisons of the glass evacuated tube solar collectors of different absorber tubes)

  • 김용;서태범;윤성은;김영민
    • 신재생에너지
    • /
    • 제2권1호
    • /
    • pp.56-65
    • /
    • 2006
  • The thermal performance of glass evacuated tube solar collectors are numerically and experimentally investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are compared. Dealing with a single collector tube, the effects of not only the shapes of the absorber tube but also the incidence angle of solar irradiation (beam irradiation) on thermal performance of the collector are studied. However, the solar irradiation consists of the beam irradiation as well as the diffuse irradiation. Also, the interference of solar irradiation and heat transfer interaction between the tubes exist in an actual solar collector, These effects are considered in this study experimentally and numerically. The accuracy of the numerical model is verified by the experimental results. The result shows that the thermal performance of the absorber used a plate fin and U-tube is the best.

  • PDF

벤토나이트 그라우트의 열물성 측정 및 열물성이 수직 지중열교환기 설계 길이에 미치는 영향 (Thermal Property Measurement of Bentonite-Based Grouts and Their Effects on Design Length of Vertical Ground Heat Exchanger)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권2호
    • /
    • pp.1-9
    • /
    • 2019
  • In a ground-source heat pump (GSHP) system, a vertical ground heat exchanger (GHE) is widely accepted due to a higher thermal performance. In the vertical GHE, grout (also called grouting material) plays an important role in the heat transfer performance and the initial installation cost of the GHE. Bentonite-based grout has been used in practice because of its high swelling potential and low hydraulic conductivity. This study evaluated the thermo-physical properties of the bentonite-based grouts through lab-scale measurements. In addition, we conducted performance simulation to analyze the effect of mixed ratio of grouts on the design length and thermal performance of the vertical GHE. The simulation results show that thermally-enhanced grouts improve the heat transfer performance of the vertical GHE and thus reduce the design length of GHE pipe.

유하식 집열기를 이용한 저가 집열 시스템의 성능해석 (Thermal Performance Analysis for the Low-Cost Solar System with Trickle-Collector)

  • 김부호;이동원
    • 태양에너지
    • /
    • 제10권3호
    • /
    • pp.19-26
    • /
    • 1990
  • 제작과 시공이 간편하고 저렴한 유하식 집열기의 열성능에 대하여 이론적 해석을 수행하였다. 개선된 이론해석의 결과는 실험결과를 잘 예측하였으며, 이 결과는 유하식 집열기를 이용한 저가 집열 시스템의 장기 열성능 해석 프로그램에 이용되었다. 문답식으로 짜여진 장기 열성능 프로그램은 f-chart 설계법에 근거하였으며, 저가 집열 시스템의 설계 및 경제성 분석에 쉽게 이용할 수 있다.

  • PDF

고정형과 추적형 Evacuated CPC 집열기의 열성능 비교 (Comparison of the Thermal Performance with Stationary and Tracking Evacuated CPC Collectors)

  • 윤성은;김용;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.19-25
    • /
    • 2004
  • A numerical study is performed to investigate the effect of sun tracking on the thermal performance of the evacuated compound parabolic concentrator (CPC) collectors. The evacuated CPC collectors consist of a two-layered glass tube, a copper tube and a reflector. The collector has a copper tube as an absorber and a reflector inside a glass tube. The water is used as a working fluid. The length and the diameter of the glass tube are 1,700mm and 70mm, respectively. The length and the diameter of the copper tube are 1,700mm and 25.4mm, respectively. Ray tracing analysis is carried out in order to compare absorbed heat fluxes on the absorber surface of the stationary and tracking collectors. The collected energy is calculated and compared with that on a fixed surface tilted at $35^{\circ}$ on the ground and facing south. The results indicate that the collected solar energy of the sun tracking system is significantly larger than that of a stationary collector. The sun tracking evacuated CPC collectors show a better performance with an increase in the thermal efficiency of up to 14% compared with an identical stationary collector.

BIM and Thermographic Sensing: Reflecting the As-is Building Condition in Energy Analysis

  • Ham, Youngjib;Golparvar-Fard, Mani
    • Journal of Construction Engineering and Project Management
    • /
    • 제5권4호
    • /
    • pp.16-22
    • /
    • 2015
  • This paper presents an automated computer vision-based system to update BIM data by leveraging multi-modal visual data collected from existing buildings under inspection. Currently, visual inspections are conducted for building envelopes or mechanical systems, and auditors analyze energy-related contextual information to examine if their performance is maintained as expected by the design. By translating 3D surface thermal profiles into energy performance metrics such as actual R-values at point-level and by mapping such properties to the associated BIM elements using XML Document Object Model (DOM), the proposed method shortens the energy performance modeling gap between the architectural information in the as-designed BIM and the as-is building condition, which improve the reliability of building energy analysis. Several case studies were conducted to experimentally evaluate their impact on BIM-based energy analysis to calculate energy load. The experimental results on existing buildings show that (1) the point-level thermography-based thermal resistance measurement can be automatically matched with the associated BIM elements; and (2) their corresponding thermal properties are automatically updated in gbXML schema. This paper provides practitioners with insight to uncover the fundamentals of how multi-modal visual data can be used to improve the accuracy of building energy modeling for retrofit analysis. Open research challenges and lessons learned from real-world case studies are discussed in detail.

건물 외피의 열특성과 외주부 깊이에 따른 PAL에 관한 연구 (A study on the PAL according to thermal characteristic of building skin and perimeter zone depth)

  • 김지혜;김환용
    • 한국태양에너지학회 논문집
    • /
    • 제30권2호
    • /
    • pp.33-38
    • /
    • 2010
  • The perimeter zone is space which receives a significant effect of ambient condition, it is necessary to improve the thermal performance in order to building energy saving. For this reason, a lot of study about the active approach is being performed, such as perimeter-less air conditioning system. But the performance of the perimeter zone is necessary to improve, through the passive approach. Therefore, the purpose of this study is to provide basic materials of energy-saving design of perimeter zone, based of the PAL that simulation changing the thickness of insulation and the rate of windows.

태양열 공기-물 가열기의 공기 가열 성능 평가 및 열적 성능 개선을 위한 실험적 연구 (Experimental Study for Estimation of Air Heating Performance and Improvement of Thermal Performance of Hybrid Solar Air-water Heater)

  • 최휘웅;김영복;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제37권1호
    • /
    • pp.47-57
    • /
    • 2017
  • Solar energy is one of the important renewable energy resources. It can be used for air heating, hot water supply, heat source of desiccant cooling system and so on. And many researches for enhancing efficiency have been conducted because of these various uses of solar thermal energy. This study was performed to investigate the air heating performance of hybrid solar air-water heater that can heat air and liquid respectively or simultaneously and finding method for improving thermal performance of this collector. This collector has both liquid pipe and air channel different with the traditional solar water and air heater. Fins were installed in the air channel for enhancing the air heating performance of collector. Also air inlet & outlet temperature, ambient temperature and solar collector's inner part temperature were confirmed with different air velocity on similar solar irradiance. As a result, temperature of heated air was shown about $43^{\circ}C$ to $60^{\circ}C$ on the $30^{\circ}C$ of ambient temperature and thermal efficiency of solar collector was shown 28% to 73% with respect to air velocity. Also, possibility of improvement of thermal performance of this collector could be ascertained from the heat transfer coefficient calculated from this experiment. Thus, it is considered that the research for finding optimal structure of hybrid solar air-water heater for enhancing thermal performance might be needed to conduct as further study based on the method for improving air heating performance confirmed in this study.

바닥복사난방의 실별제어시스템에 관한 열성능 평가 (An Evaluation on the Thermal Performance of the Room Control System for Radiant Floor Heating)

  • 석호태;김오봉;조영흠;김광우;여명석
    • 한국주거학회논문집
    • /
    • 제14권5호
    • /
    • pp.75-82
    • /
    • 2003
  • In this study, the thermal performance of the room control system is analyzed in terms of control performance, potential for coil expansion and energy consumption through experiments comparing the individual room control system and an existing system. The results of this study show that the existing system is not able to supply design water flow rate and does not accurately maintain the set point temperature in each room. However, the individual room control system can set a room air temperature for each room, for it is able to supply design water flow and accurately control the set point temperature in each room and can reduce the energy consumption compared to the existing system. Moreover, the individual room control system can reduce the number of coil division zone and facilitates the construction process, because it can extend the length of the coil division.

제로카본 그린홈 구현을 위한 하이브리드 열공급 시스템의 열성능 분석 (Thermal Performance Analysis of Hybrid heat Supply System for Zero Carbon Green Home)

  • 주홍진;이경호;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.53-59
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000kcal/hr, a $0.15m^3$ hot water storage tank for space heating, a evacuated tubular solar collector $3.74m^2$ of aperture area at the $20^{\circ}$ install angle, a $0.3m^3$ hot water storage tank. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

아파트 적용 태양열 난방 및 급탕시스템의 열적 거동에 관한 실험연구 (Experimental Study on the Thermal Behavior of Solar Space Heating & Hot Water System in Apartment)

  • 신우철;백남춘;김종현
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.127-134
    • /
    • 2006
  • In this paper, an experiment was carried out to investigate the thermal behavior and performance on a solar space heating & hot water system in an apartment. Measurement was continued for 6 months between January 1st 2004 and June 31th 2004. The results show that there is no problem in control and operation in case of connection this system with conventional space heating and hot water system, and that the thermal performance of this system and indoor thermal environment is good.