• Title/Summary/Keyword: Thermal Sensitivity

Search Result 636, Processing Time 0.022 seconds

External Attachment of Pop-up Satellite Archival Tag (PSAT) and Water Temperature Affect Oxygen Consumption Rate of the Olive Flounder Paralichthys olivaceus (넙치(Paralichthys olivaceus) 산소 소비율에 미치는 Pop-up Satellite Archival Tag (PSAT) 체외 부착과 수온의 영향)

  • Geun Su Lee;Pil Jun Kang;Hye Mi Park;Sung-Yong Oh
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.5
    • /
    • pp.660-666
    • /
    • 2023
  • This study aimed to examine the effect of external pop-up satellite archival tags (PSATs) attachment and water temperature on the oxygen consumption rate (OCR) of the olive flounder (mean body weight 2281.7 g). The OCRs of fish were measured under conditions of three different water temperature conditions (15, 20, and 25℃) and two different tagging methods [non-tagging, control; bio-logger external attachment with a miniature PSAT (dummy mrPAT), BEA] using a closed flow-through respirometer. The OCRs of fish linearly increased with the increase in water temperature in both the control and BEA (P<0.001); however, the OCRs of BEA were approximately 1.8-1.9 times lower than those of the control at each water temperature (P<0.001). The Q10 values of the control and BEA were the highest in the water temperature range of 15 to 20℃, but sensitivity to water temperature changes was higher in BEA than in the control. The metabolic energy loss rate (MEL) of fish increased with increasing water temperature regardless of external tagging, but the MEL of the control was higher than that of BEA (P<0.001). These results demonstrate that OCR, thermal sensitivity, and energy expenditure are all affected in adult olive flounder with external PSAT attachment.

Performance of MiniPCRTM mini8, a portable thermal cycler (휴대용 DNA증폭기 MiniPCRTM mini8 Thermal Cycler의 성능 검토)

  • Kwon, Han-Sol;Park, Hyun-Chul;Lee, Kyungmyung;An, Sanghyun;Oh, Yu-Li;Ahn, Eu-Ree;Jung, Ju Yeon;Lim, Si-Keun
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2016
  • A small and inexpensive thermal cycler (PCR machine), known as the MiniPCRTM Mini8 Thermal Cycler (Amplyus, Cambridge, MA, USA), was developed. In this study, the performance of this PCR machine was compared with the GeneAmp® PCR system 9700 (Applied Biosystems) using four autosomal short tandem repeat (STR) kits, a Y-chromosome STR kit, and a mitochondrial DNA HV1/HV2 sequence analysis. The sensitivity and stochastic effects of the STR multiplex kits and the quality of the DNA sequence analysis were similar between the two PCR machines. The MiniPCRTM Mini8 Thermal Cycler could be used for analyses at forensic DNA laboratories and crime scenes. The cost of the PCR is so economical that school laboratories and individuals could use the machines.

A Study for Control of Thermal Cracking by Heat of Hydration in Subway Concrete Box Structure (지하철 콘크리트 BOX 구조물의 수화열에 의한 온도균열 제어 방안 연구)

  • Song, Suk-Jun;Yoo, Sang-Geon;Park, Ji-Woong;Kim, Eun-Kyum
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.1024-1029
    • /
    • 2009
  • According to increase of massive concrete structures, Thermal crack done by heat of hydration have been increased in a process of the execution. In case of a subway concrete box structure, thickness of structures are almost over 1 meter, and penetrating crack by external restraint takes a bad effect on the durability with a water leakage and deterioration in especially concrete wall. A try of shortening a constructing period often occurs as subway is generally constructed according to a road to decrease a traffic jam. The research proposes executing method by skipping one block as a plan of shortening a constructing period and investigate an influence on thermal cracking control. Additionally, sensitivity analysis is accomplished by changing a height of a concrete wall, and concrete placing and air temperature met with a field condition.

Neutron Personal Dose Equivalent Evaluation Using Panasonic UD-809P Type TLD Albedo Dosimeters (Panasonic UD-809P 알비도 열형광선량계를 이용한 중성자 개인선량당량 평가)

  • Shin, Sang-Woon;Son, Joong-Kwon;Jin, Hua
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.143-154
    • /
    • 1999
  • Panasonic UD-809P type albedo neutron TL dosimeters mounted on a water phantom were used to measure neutron personal dose equivalent in a Korean nuclear power plant. From the measured TL readings, personal dose equivalents from thermal, epithermal and fast neutrons were evaluated by using a method adopted in a neutron dose calculation algorithm for Panasonic UD-809P type albedo neutron TL dosimeters, which was suggested in a Panasonic TLD System User's Manual. The results showed that personal dose equivalent from fast neutrons could not be adequately evaluated in a field with high thermal neutron fraction to be encountered in a nuclear power plant. This seems to be related to the incomplete incidence of albedo thermal neutrons to the TL dosimeters. In order to evaluate appropriately the personal dose equivalent from fast neutrons in the field condition, new method fer the neutron dose calculation algorithm was suggested. In this new method, neutrons are grouped into thermal neutrons and fast neutrons. For each neutron component, equations for TL response, sensitivity factor, calibration factor and personal dose equivalent were derived.

  • PDF

A Study on the Application of Simulation-based Simplified PMV Regression Model for Indoor Thermal Comfort Control (실내 온열환경 쾌적 제어를 위한 단순 PMV 회귀모델의 적용에 관한 시뮬레이션 연구)

  • Kim, Sang-Hun;Yun, Sung-Jun;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.69-77
    • /
    • 2015
  • The PMV regression analysis was conducted for this model based on a database of the PMV variables. PMV regression model simplification was completed through sensitivity and data analysis. The simplified PMV regression model's and Fanger PMV model was confirmed through MAE and RMSE. And the EMS in EnergyPlus was used to establish a simplified PMV regression analysis-based thermal comfort control. Also, the thermal comfort controls based on simplified PMV model and the Fanger PMV model were applied to the building model, it was confirmed that both controls met the thermal comfort range in more than 90% of cases during the air conditioning period.

Designing a Highly Sensitive Eddy Current Sensor for Evaluating Damage on Thermal Barrier Coating (열차폐코팅의 비파괴적 손상 평가를 위한 고감도 와전류 센서 설계)

  • Kim, Jong Min;Lee, Seul-Gi;Kim, Hak Joon;Song, Sung Jin;Seok, Chang Seong;Lee, Yeong-Ze
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.202-210
    • /
    • 2016
  • A thermal barrier coating (TBC) has been widely applied to machine components working under high temperature as a thermal insulator owing to its critical financial and safety benefits to the industry. However, the nondestructive evaluation of TBC damage is not easy since sensing of the microscopic change that occurs on the TBC is required during an evaluation. We designed an eddy current probe for evaluating damage on a TBC based on the finite element method (FEM) and validated its performance through an experiment. An FEM analysis predicted the sensitivity of the probe, showing that impedance change increases as the TBC thermally degrades. In addition, the effect of the magnetic shield concentrating magnetic flux density was also observed. Finally, experimental validation showed good agreement with the simulation result.

Development of PKNU3: A small-format, multi-spectral, aerial photographic system

  • Lee Eun-Khung;Choi Chul-Uong;Suh Yong-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.5
    • /
    • pp.337-351
    • /
    • 2004
  • Our laboratory originally developed the compact, multi-spectral, automatic aerial photographic system PKNU3 to allow greater flexibility in geological and environmental data collection. We are currently developing the PKNU3 system, which consists of a color-infrared spectral camera capable of simultaneous photography in the visible and near-infrared bands; a thermal infrared camera; two computers, each with an 80-gigabyte memory capacity for storing images; an MPEG board that can compress and transfer data to the computers in real-time; and the capability of using a helicopter platform. Before actual aerial photographic testing of the PKNU3, we experimented with each sensor. We analyzed the lens distortion, the sensitivity of the CCD in each band, and the thermal response of the thermal infrared sensor before the aerial photographing. As of September 2004, the PKNU3 development schedule has reached the second phase of testing. As the result of two aerial photographic tests, R, G, B and IR images were taken simultaneously; and images with an overlap rate of 70% using the automatic 1-s interval data recording time could be obtained by PKNU3. Further study is warranted to enhance the system with the addition of gyroscopic and IMU units. We evaluated the PKNU 3 system as a method of environmental remote sensing by comparing each chlorophyll image derived from PKNU 3 photographs. This appraisement was backed up with existing study that resulted in a modest improvement in the linear fit between the measures of chlorophyll and the RVI, NDVI and SAVI images stem from photographs taken by Duncantech MS 3100 which has same spectral configuration with MS 4000 used in PKNU3 system.

Prediction of Thermal-Hydraulic Phenomena in the LBLOCA Experiment L2-3 Using RELAP5/MOD2 (RELAP5/MOD2 코드에 의한 대형냉각재 상실사고 모사실험 L2-3의 열수력 현상 예측)

  • Bang, Young-Seok;Chung, Bub-Dong;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.56-65
    • /
    • 1991
  • The LOFT LOCE L2-3 was simulated using the RELAP5/MOD2 Cycle 36.04 code to assess its capability in predicting the thermal-hydraulic phenomena in LBLOCA of a PWR. The reactor vessel was simulated with two core channels and split downcomer modeling for a base case calculation using the frozen code. The result of the base calculation showed that the code predicted the hydraulic behavior, and the blowdown thermal response at high power region of the core reasonably and that the code had deficiencies in the critical How model during subcooled-two-phase transition period, in the CHF correlation at high mass flux and in the blowdown rewet criteria. An overprediction of coolant inventory due to the deficiencies yielded the poor prediction of reflood thermal response. Improvement of the code, RELAP5 / MOD2 Cycle 36.04, based on the sensitivity study increased the accuracy of the prediction of the rewet phenomena.

  • PDF

Women's Comfort Temperature Range and Dynamic Temperature Change for Maintaining Thermal Comfort in Low Temperature Environment (저온환경에서 여성 온열쾌적성 유지를 위한 쾌적온도범위 및 동적 온도변화 연구)

  • Kim, Soyoung;Lee, Okkyung;Lee, Heeran
    • Fashion & Textile Research Journal
    • /
    • v.22 no.6
    • /
    • pp.853-861
    • /
    • 2020
  • Various types of clothing are being developed to boost thermal comfort during cold winters along with research on change of body temperature when heating is applied. There is a noticeable behavioral difference by gender when using heating panels in a cold environment; however, research on women has been insufficient. This study find a temperature range that provides sustainable thermal comfort in a low temperature environment by observing temperature and change of temperature when subjects are classified according to physical activities or cold sensitivities. For the study results, 8 women in their 20s were subjected to experiment in a low temperature environment for 75 minutes (sitting position: 30 min., running: 15 min., and sitting position: 30 min.). Subjects were asked to turn on/off the heating panel freely to analyze the range of comfortable temperature and clothing microclimate; in addition, skin temperature and heating panel temperature were measured and analyzed at 9 points. As a result, temperature at which subjects turn on and off the heating panel indicated a statistically meaningful difference between the cold sensitivity group depending on exercise or non-exercise. The range of comfortable abdomen temperature was wider than the lower back and was significantly reduced when the subject was running. The range of comfortable temperature was also largest for the heating panel temperature, microclimate, and skin temperature in suggesting that adequate adjustment will be required depending on the surrounding environment or movement of the wearer.

Methane Gas Sensing Properties of the Zinc Oxide Nanowhisker-derived Gas Sensor

  • Moon, Hyung-Sin;Kim, Sung-Eun;Choi, Woo-Chang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.2
    • /
    • pp.106-109
    • /
    • 2012
  • A low power methane gas sensor with microheater was fabricated by silicon bulk micromachining technology. In order to heat up the sensing layer to operating temperature, a platinum (Pt) micro heater was embedded in the gas sensor. The line width and gap of the microheater was 20 ${\mu}m$ and 4.5 ${\mu}m$, respectively. Zinc oxide (ZnO) nanowhisker arrays were grown on a sensor from a ZnO seed layer using a hydrothermal method. A 200 ml aqueous solution of 0.1 mol zinc nitrate hexahydrate, 0.1 mol hexamethylenetetramine, and 0.02 mol polyethylenimine was used for growing ZnO nanowhiskers. Temperature distribution of the sensor was analyzed by infrared thermal camera. The optimum temperature for highest sensitivity was found to be $250^{\circ}C$ although relatively high (64%) sensitivity was obtained even at as low a temperature as $150^{\circ}C$. The power consumption was 72 mW at $250^{\circ}C$, and only 25 mW at $150^{\circ}C$.