• 제목/요약/키워드: Thermal Insulate

검색결과 10건 처리시간 0.024초

수증기 투과형 단열 복합 방수 시스템의 단열 성능에 관한 연구 (A study on the heat insulation performance of vapor penetration-insulate complex waterproofing system.)

  • 최수영;안기원;장덕배;김종필;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.62-63
    • /
    • 2016
  • In addition to the waterproof sheet waterproof objectives that apply to the building roof it is being constructed, including a complex such as insulation performance, root-resistance. However, thermal insulation of the composite waterproofing sheet is an insulating effect a wide variety depending on the specific construction -specific, material and even the effect is this part of the test to the generation when insignificant compared to each other a number of roof insulation effect of the insulation composite waterproof sheet that is currently in effect analysis.

  • PDF

공동주택의 단열현황 조사 및 단열보강 적용방안에 관한 연구 ((A)Study on Apartment Insulation Status and Insulation reinforcement Application)

  • 정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.226-227
    • /
    • 2015
  • This research is to measure and analyze the thermal performance of the apartment structure and to evaluate and establish standards of thermal insulation defect in order to make the basic data necessary for determining the degree of the thermal performance degradation and for repairing and reinforcing the exterior wall of the existing apartment. The following conclusions could be derived thorough the investigation of outer wall temperature distribution and the insulation assesment experiments using a model of specimens for the apartment houses' outer walls. It was confirmed that for the thermal performance through the insulating material thicknesses 5cm, 8cm in walls, the thermal insulation thickened by 3cm, from 5cm to 8cm, but that the actual temperature difference reached only about 1 ~ 2℃. This implies that the thermal performance improvement using the thermal insulation in walls is not significant and that it is difficult to insulate the thermal bridge area.

  • PDF

확장형 발코니 공동주택의 창호종류에 따른 결로 및 온열환경에 관한 연구 (A Study on the Condensation and Thermal Environment according to Window Systems Types Installed for a Extended-Balcony Apartment)

  • 윤종호;안영섭;김병수
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.87-92
    • /
    • 2007
  • As expansion of balconies at apartments has been legalized, the major function of the balconies as a thermal buffer zone is disappearing. This weakens the ability of window to insulate heat and multiplies surface condensation. Thus more and more residents require solutions to increasing surface condensation and aggravation in thermal comfort. This study intends to provide basic data by evaluating performance of triple layered Low-E windows, triple layered clear windows, double layered Low-E windows and double layered clear window used for expanded balconies and marketed within the country in terms of surface condensation and thermal environment through simulation. Results revealed that no surface condensation occurred at double layered Low-E windows and triple layered Low-E windows. Surface condensation took place at double layered clear windows and triple layered clear windows at a relative humidity of 60%. Thermal environment analysis suggested that double layered clear windows showed the most time falling into the range of comfort at $23^{\circ}C$. The figure were $22^{\circ}C$ for triple layered clear windows, $22^{\circ}C$ for double layered Low-E windows and $21^{\circ}C$ for triple layered Low-E windows.

열경화성 복합재 로켓 방화벽의 파손 예측 (Failure Prediction of Thermo-Chemically Decomposing Composite for Rocket Thermal Insulators)

  • 이선표;이정윤
    • 한국추진공학회지
    • /
    • 제9권2호
    • /
    • pp.25-31
    • /
    • 2005
  • 카본-페놀릭 복합재로 제작된 로켓 방화벽이 운전조건 하에서 열-화학적 분해되는 것을 해석하기 위해 (1)의 논문에 기술된 열 및 기체확산을 수반하는 다공 탄성 복합재료의 거동이론을 적용하였다. 해석 대상의 구조 부재는 카울 링이며, 재료 내의 압력, 온도 및 층간 응력이 제시되었다. 특정 조건의 복합재 구조에 대한 해석의 결과는 재료 내의 발생하는 인장응력에 의해 플라이리프트를 나타내는 충간파손을 나타낸다. 해석 결과는 실제 구조의 파손과 모양 및 위치가 일치한다. 이 방법은 플라이리프트와 같은 파손을 피하기 위한 설계에 적용될 수 있다.

주상변압기 열적 특성 향상을 위한 복합절연 시스템 적용 (The Study on Application of Hybrid Insulation System for Thermally Upgraded Distribution pole Transformers)

  • 이병성;송일근;이재봉;김동명;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1896-1898
    • /
    • 2002
  • In this paper, to developing thermally and mechanically upgraded ones, we dismounted pole transformers used in the fields for over 13 years and conducted aged oil analysis. Also, when the cellulose and aramid papers in test cell were aging with oil at $130^{\circ}C$ for 3000 hours, with the testing period cellulose paper deteriorated more rapidly than the others. For example dielectric strength and dissipation factor of papers deteriorated with aging time. For evaluation of thermal aging characteristics, a mineral oil-immersed transformer was constructed with hybrid insulation system comprised of aramid paper and cellulose insulation. A Hybrid system has economic advantages. Cellulose materials are confined to cooler regions of the transformer winding. And aramid papers are served to insulate contact parts of hot conductors.

  • PDF

Design and evaluation of the thermal capability to secure a working time of cryogenic explosion-proof camera in LNG carrier tank

  • Kang, Geun-Il;Kwak, Si-Young;Park, Chun-Seong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권5호
    • /
    • pp.568-576
    • /
    • 2017
  • With an increase in the usage of LNG, there is a heightened interest about its safety aspects regarding the explosion of LNG carrier tank. The need for a cryogenic explosion-proof camera has increased. The camera has to work in cryogenic environment (below $-160^{\circ}C$) in LNG carrier. This study conducted design and heat transfer analysis of cryogenic camera to secure working time in limitation of heat source. The design with gap width of double pane windows was conducted based on simple vertical cavity model to insulate from cryogenic environment. The optimal gap width was 12.5 mm. For effective analysis considering convection within the camera, equivalent thermal conductivity method was adopted with ABAQUS. The working time of the camera predicted was over 10 h at warm-start condition. In cold-start condition, it required about 5 h of pre-warming time to work. The results of analysis were compared with the ones of the actual cryogenic test.

EWT를 고려한 지중열교환기 파이프 선정에 관한 연구 (A Study on Selection of Pipe Materials Considering EWT)

  • 류형규;정민호;이병석;최현준;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권2호
    • /
    • pp.13-18
    • /
    • 2014
  • This paper proposes an optimum pipe material (PVC vs. PE) design & selection for open loop ground heat exchangers. Heat exchange efficiency and/or workability, and the need for trench insulation were investigated by comparing EWT (cooling mode) of each system. CFD simulations for the PVC and PE pipe with the same inner diameter show similar EWT. This is because the PVC pipe has a small thickness but a low thermal conductivity as compared to the PE pipe, and thus these two properties tend to offset each other. However, a hypothetically insulated pipe led to a meaningful drop of EWT. This means pipe insulation is of importance in performance of ground heat exchangers. From analyzing climate data and system operation, it is not advantageous to insulate trench pipes due to construction difficulties and ground temperature characteristics that are seasonally varied.

A Study on the Cold Reserving Performance of PET Bottle with Shrinkage Film

  • Hong, Dae Gi;Lyu, Min Young
    • Elastomers and Composites
    • /
    • 제54권2호
    • /
    • pp.123-127
    • /
    • 2019
  • Shrink film is currently being used for plastic container lavels to avoid the use of glue. Polyethylene terephthalate (PET) bottle lavels also use shrink films in the same PET materials for easy recycling of PET bottles. An air layer is generated between the shrink film and PET bottle surface due to the bent shape of the bottle surface. This air layer can insulate external heat, as air has a relatively lower thermal conductivity. In this study, the insulation property of the air layer was examined by computer simulation. Two PET bottle models were used, one with and the other without an air layer between the PET bottle surface and lavel. The two bottle models were filled with cold liquid and exposed to room temperature for 6 h, and the temperatures of the contents were then compared. The results showed that the temperature of the contents in the bottle with the air layer was lower than that without the air layer by at least $2^{\circ}C$. This study suggests an effective lavel design of PET bottles while ensuring that the temperature of the bottle contents is maintained.

방한을 목적으로 하는 군용 섬유제품 충전재의 보온성 시험방법에 대한 표준화 연구 (A Study on the Standard Test Method for Thermal Resistance of Military Textile Thermal Insulator for Winter Season)

  • 여용헌;홍성돈;이민희;김경필;정일한
    • 한국산학기술학회논문지
    • /
    • 제19권9호
    • /
    • pp.492-500
    • /
    • 2018
  • 동절기 방한복의 성능 평가는 주로 열 저항으로 이루어지고 있다. 그러나, 이를 측정하기 위한 KS가 개정되면서, 동일한 표본의 시험결과가 개정 결과에 비하여 감소하는 결과를 초래하였다. 또한, 공인 시험기관마다 변경된 시험 절차 대한 해석의 차이가 발생하여 시험 기관 간에 결과 편차도 크게 발생하고 있으며, 이로 인해 군수품의 품질보증에 상당한 애로가 되고 있다. 따라서 본 연구에서는 개정된 시험방법에 따른 보온율 감소 현상의 원인을 분석함으로써, 개정 전과 후의 결과 편차를 최소화하고자 한다. 이를 위해 규격의 개정 전과 개정 후의 시험 조건의 차이와 이로 인해 발생 가능한 결과를 검토한다. 또한, 규격의 임의해석에 따른 시험 기관간 결과 편차 발생의 원인을 분석함으로써 시험 기관간의 결과 편차를 최소화 하고자 한다. 이를 바탕으로 개정 전 시험 방법과 편차가 가장 적은 조건을 확인하여 보온율 감소 현상을 예방하기 위한 표준을 제시하고자 한다.

고 용융점 소재의 압출적층성형을 위한 우수한 방열특성을 갖는 3차원 프린터 nozzle부 기구설계 (Structural Design of 3D Printer Nozzle with Superior Heat Dissipation Characteristics for Deposition of Materials with High Melting Point)

  • 김완진;이상욱
    • 한국전자통신학회논문지
    • /
    • 제15권2호
    • /
    • pp.313-318
    • /
    • 2020
  • 300도 이상의 높은 용융점을 갖는 소위 엔지니어링 플라스틱은 기구적인 강성과 내화학성 및 마찰 및 마모성능이 우수하여 여러 산업에서 금속을 대체하는 소재로 각광받고 있다. 본 연구에서는 용융적층모델링 공법을 기반으로 하는 3D 프린터에서 높은 용융점을 갖는 엔지니어링 플라스틱을 조형할 수 있도록 방열특성이 우수한 3D 프린터 nozzle부의 구조를 설계하고 이를 해석적으로 검증하였다. 높은 온도로 가열되는 heat block과 필라멘트가 이송되는 nozzle상부 간의 단열 및 신속한 냉각을 위하여, 열전도계수가 낮은 열차단부(heat brake부)를 2중으로 구성하였고, 열차단부에 생성되는 열이 냉각핀을 통해 대기에 의해 냉각되는 구조를 적용하였다. 개선된 nozzle부 구조설계를 통해 종래 3D 프린터의 BCnozzle과 비교할 때, heat sink부에서의 온도를 50% 가량 낮출 수 있었으며, heat block에 직접적으로 연결된 heat brake부 최종단의 정상상태 온도를 14% 가량 낮출 수 있었다.