  • This paper presents a diagnostic method for a sparse matrix converter that detects faults in any single switch or a pair of switches. The sparse matrix converter is functionally equivalent to the standard matrix converter but has a reduced number of switches. The proposed diagnostic method is based in the measurement of input and output currents. The currents have respective characteristic according to the location of faulty switches. This method not only detects the switches of open-circuit fault but identifies the location of the faulty switching devices without complicated calculations. The simulation and experimental results verify that, based on the proposed method, the fault of sparse matrix converter can be easily and fast detected.

A Fault-Tolerant Control Strategy for Cascaded H-Bridge Multilevel Rectifiers

  • Iman-Eini, Hossein;Farhangi, Shahrokh;Schanen, Jean-Luc;Khakbazan-Fard, Mahboubeh
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.34-42
    • /
    • 2010
  • Reliability is an important issue in cascaded H-bridge converters (CHB converters) because they use a high number of power semiconductors. A faulty power cell in a CHB converter can potentially lead to expensive downtime and great losses on the consumer side. With a fault-tolerant control strategy, operation can continue with the undamaged cells; thus increasing the reliability of the system. In this paper, the operating principles and the control method for a CHB multilevel rectifier are introduced. The influence of various faults on the CHB converter is investigated. The method of fault diagnosis and the bypassing of failed cells are explained. A fault-tolerant protection strategy is proposed to achieve redundancy in the CHB rectifier. The redundant H-bridge concept helps to deal with device failures and to increase system reliability. Simulation results verify the performance of the proposed strategy.

배전시스템센서의 순간전압강하 분석 (Analysis of Voltage Sag on Power Distribution System)

  • 오정환;임성정;윤상윤;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.954-957
    • /
    • 1997
  • In this paper, we analyze the voltage sag caused by reclosing on electric power distribution system. When a fault is on the electric system, a reclosing operation brings a voltage sag on the feeders which is supplied with a common substation transformer. By analyzing the fault wave-form measured in the field, it is showed that a voltage sag is in proportion to a fault current. Also, we propose an adaptive reclosing scheme. This scheme changes the number of reclosing as a function of the magnitude of a fault voltage and the fault type. As the proposed scheme is compared with conventional scheme in the side of voltage sag and permanent fault, it is verified that the proposed scheme is more effective than conventional scheme.

  • PDF

Low Impedance Fault 검출을 위한 최적 마더 웨이브렛의 선정 (Selection of mother wavelet for Low Impedance Fault Detection)

  • 변성현;김철환;김일동;한경남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1012-1014
    • /
    • 1997
  • This paper introduces wavelets and shows that they may be efficient and useful for the detection of general faults in power system. The wavelet transform of a signal consists in measuring the "similarity" between the signal and a set of translated and scaled versions of a "mother wavelet". The "mother wavelet" is a chosen fast decaying oscillation function. A number of mother wavelet for signal analysis have been proposed and some of them are in use in fault detection. However, the performance of fault detection depend on used mother wavelet. In the present paper a comparative evaluation of different mother wavelets for low impedance fault detection is performed. The discussion is focused in well-known mother wavelet based wavelet transform. Several families of wavelets are used to analyse transient earth fault signals in a 345kV model system as generated by EMTP.

  • PDF

MATLAB을 이용한 GUI 소프트웨어 개발에 관한 연구 (A Study on the Development of GUI Software using MATLAB)

  • 김병천;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.449-451
    • /
    • 2000
  • Arcing fault on overhead lines can be detected by amplitude of the arc voltage using numerical algorithm. In the case of transient fault, the arc voltage has any high value. In the case of permanent fault, the arc voltage is near zero. Thus, fault distance estimation should be performed by digital distance relay algorithm[3]. The purpose of this study is to build a structure for modeling of arcing fault detection and fault distance estimation algorithm using Matlab programming. Additionally, this algorithm has been designed in Graphical User Interface(GHI). So, this method using GUI interface of Matlab can reduce the number of simulation steps in modeling the distance relay.

  • PDF

근본 출력에 근거한 고장 모의실험 (A Fault Simulation Method Based on Primary Output)

  • 이상설;박규호
    • 전자공학회논문지B
    • /
    • 제31B권6호
    • /
    • pp.63-70
    • /
    • 1994
  • In this paper, we propose a fault simulation method based on primary output in combinational circuit. In the deterministic test pattern generation, each test pattern is genterated incrementally. The test pattern is applied to the primary inputs of circuit under test to simulate faults. We detect the faults with respect to each primary output. The fault detection with resptect to each primary output is reflected by the corresponding bit in the detection words, and efficient fault detection for the reconvergent fan-out stem is achieved with dynamic fault propagation. As an experimental result of the fault simulation with our method for the several bench mark circuits, we illustrated the good performance showing that the number of gates to be activated is much reduced as compared with other method which is not based on primary output.

  • PDF

고장에 강인한 구형 3자유도 모듈에 관한 기구학적 해석 (Kinematic Analysis of Fault-Tolerant 3 Degree-of-Feedom Spherical Modules)

  • 이병주;김희국
    • 대한기계학회논문집
    • /
    • 제18권11호
    • /
    • pp.2846-2859
    • /
    • 1994
  • This work deals with kinematic analysis of fault-tolerant 3 degree-of-freedom spherical modules which have force redundancies in its parallel structure. The performance of a redundantly actuated four-legged module with no actuator failure, a single actuator failure, partial and half failure of dual actuator are compared to that of a three-legged module, in terms of maximum force transmission ratio, isotropic characteristics, and fault-tolerant capability. Additionally, a system with an excess number of small floating actuators is considered, and the contribution of these small actuators to the force transmission and fault-tolerant capability is evaluated. This study illustrates that the redundant actuation mode allows significant saving of input actuation effort, and also delivers a fault tolerance.

A top-down iteration algorithm for Monte Carlo method for probability estimation of a fault tree with circular logic

  • Han, Sang Hoon
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.854-859
    • /
    • 2018
  • Calculating minimal cut sets is a typical quantification method used to evaluate the top event probability for a fault tree. If minimal cut sets cannot be calculated or if the accuracy of the quantification result is in doubt, the Monte Carlo method can provide an alternative for fault tree quantification. The Monte Carlo method for fault tree quantification tends to take a long time because it repeats the calculation for a large number of samples. Herein, proposal is made to improve the quantification algorithm of a fault tree with circular logic. We developed a top-down iteration algorithm that combines the characteristics of the top-down approach and the iteration approach, thereby reducing the computation time of the Monte Carlo method.

전압증가 시 재폐로 동작에 따른 변압기형 초전도 한류기의 특성 분석 (Characteristics on the Transformer-Type SFCL According to Reclosing Operation the Voltage Increase)

  • 최수근;최효상
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.477-480
    • /
    • 2010
  • Fault current in power system is expected to increase by demand of power capacity. Therefore, when the fault occurred, fault current was increased in the power system. Many studies have been progressed to limit the fault current. Superconducting fault current limiter (SFCL) is one of them which has been studied in worldwide. In this paper, we will analyze characteristics of a transformer-type SFCL by reclosing operation when the voltage increases. Twice opening times in the reclosing of circuit breaker were set as the 0.5 and 15 seconds, respectively. Turn's number of primary and secondary coils set 4:2 and we increased voltages from 120V to 280V for each experiment. By the current waveform, maximum fault current in second and third cycles was lowered when the voltage was increased. In the recovery waveform, recovery time was increased as the voltage was increased. The reason was that power burden of the SFCL increased when consumption power was increased, so the time to get back to SFCL took longer. We compared the characteristics of a resistive-type and transformer-type SFCL. As a result, we found that the fault current of a transformer-type was lower than resistive-type and recovery time of the SFCL was shorter. Consequently, transformer-type SFCL was more profitable for limitation of fault current and recovery time under the same condition for reclosing operation.

연동해석을 통한 영구자석 동기전동기의 오프라인 Inter-Turn 고장진단법 (A Method for Offline Inter-Turn Fault Diagnosis of Interior Permanent Magnet Synchronous Motor through the Co-Analysis)

  • 조수영;오예준;이강석;배재남;이주
    • 전기학회논문지
    • /
    • 제67권3호
    • /
    • pp.365-373
    • /
    • 2018
  • In this paper, inter-turn fault diagnosis of the interior permanent magnet synchronous motor (IPMSM) is performed in offline state by linking the finite element analysis (FEA) tool and control simulation tool. In order to diagnose the inter-turn fault, it is important to select the current value to determine the fault. First, the basic principles for inter-turn fault diagnosis of IPMSM are explained and co-analysis model for fault diagnosis is constructed. Further, in order to select the appropriate high frequency voltage, the change of the current value to be judged as failure was analyzed at various voltage and frequency conditions, and the change of the current value according to the number of the failed windings was analyzed. Finally, the current value to be judged as failure is selected.