• Title/Summary/Keyword: The Masking Method

Search Result 334, Processing Time 0.029 seconds

HVS Based Digital Watermarking Using the POCS Theory (POCS 이론을 이용한 인간시각시스템 기반 디지털 워터마킹)

  • Kim, Hee-Jung;Seo, Yong-Su;Kim, Ji-Hong
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.4
    • /
    • pp.516-524
    • /
    • 2005
  • In this paper, a new watermarking scheme based on the POCS theory and human visual system is proposed. Using the POCS theory, watermarks are embedded into imperceptible image regions such as edge and strong texture area in the spatial domain. Also it is inserted into middle frequency band in the transform domain to achieve the robustness against compression and filtering, etc. In addition, different gain factors are employed into blocks classified by considering texture masking effect. By doing so, the proposed method has a novel property of having both the imperceptibility and the robustness simultaneously. Simulation results show that the proposed method has an excellent performance better than conventional approaches.

  • PDF

Highly Selective Derivative Spectrophotometry for Determination of Nickel Using 1-(2-Pyridylazo)-2-naphthol in Tween 80 Micellar Solutions

  • Eskandari, Habibollah
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.8
    • /
    • pp.1137-1142
    • /
    • 2004
  • A spectrophotometric and first derivative spectrophotometric method was developed in aquatic Tween 80 micellar solutions for selective determination of nickel without using any pre-separation step. 1-(2-Pyridylazo)-2-naphthol (PAN), as a sensitive chromogenic complexing agent formed a red-colored Ni(II)-PAN complex in Tween 80 media with satisfactory solubility and stability. Conditions such as pH, PAN concentration, type and concentration of micellizing agent were optimized. Molar absorptivity of Ni-PAN complex was found $4.62\;{\times}\;10^4L\;cm^{?1}\;mol^{?1}$ at 569 nm, under the optimum condition. Calibration graphs were derived by zero, first and second derivative spectrophotometry at maximum wavelengths of 569, 578 and 571 nm with linear ranges of 30-1800, 20-2500 and 30-2000 ng $mL^{?1}$ , respectively. Precision as standard deviation as well as accuracy as recovery percent were in the range of 1-20 ng $mL^{?1}$, and 93.3-103.3%, respectively, for the entire of the linear ranges. Spectrophotometric detection limit was 3 ng $mL^{?1}$ and effects of diverse ions on the first derivative determination of nickel were studied to investigate selectivity of the method. Interferences of cobalt and copper on the nickel determination were prevented using o-phenanthroline as masking agent. The recommended procedures were applied to the various synthetic and stainless steel alloys, tea leaves and human hair, with satisfactory results.

Determination of Mn, Co, Ni and Cu in Iron Oxide Ore by Atomic Absorption spectroscopy. Utilization of APDC-MIBK Extraction System (원자흡수 분광법에 의한 철광석중의 Mn, Co, Ni 및 Cu 의 정량. APDC-MIBK 추출계의 이용)

  • Misun Park;Youn-Doo Kim;Kwanghee Koh Park
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.315-320
    • /
    • 1989
  • A method was presented for the analysis of trace metals in iron oxide ore. The method utilized ammonium pyrrolidinedithiocarbamate (APDC)-methyl isobutyl ketone (MIBK) extraction procedure and analysis by atomic absorption spectroscopy (AA). Citrate at pH $8{\sim}10$ for the determination of Co, Ni and Cu or tiron at pH $6{\sim}7$for the determination of Mn and Cu was added as a masking agent to prevent extraction of Fe(III) into the organic phase. Reduction of solubility of MIBK in water was achieved by addition of NaCl as a salting-out agent. Back extraction of the MIBK extracts with aqueous $HNO_3$ was also studied to increase the stability of metal extracts.

  • PDF

Analysis of Selective Emitter Properties Apply for Low Cost Metallization in Crystalline Silicon Solar Cells (결정질 실리콘 태양전지의 저가형 금속전극에 적용되기 위한 Selective emitter 특성 분석)

  • Kim, Min-Jeong;Lee, Ji-Hun;Cho, Kyeong-Yeon;Lee, Soo-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.454-455
    • /
    • 2009
  • Selective emitter structure have an important research subject for crystalline silicon solar cells because it is used in production for high efficiency solar cells. A selective emitter structure with highly doped regions underneath the metal contacts is widely known to be one of the most promising high-efficiency solution in solar cell processing. Since most of the selective emitter processes require expensive extra masking and double steps process. Formation of selective emitters is not cost effective. One method that satisfies these requirements is the method of screen-printing with a phosphorus doping paste. In this paper we researched two groups of selective emitter structure process. One was using dopant paste, and the other was using solid source, in order to compare their uniformity, sheet resistance and performance condition time.

  • PDF

Determination of Silver with Mercaptans (I). Amperometric Titration of Silver with 2,5-Dimercapto-1,3,4-Thiadiazole (Mercapto 화합물에 의한 은의 정량 (제1보) 2,5-Dimercapto-1,3,4-Thiadiazol에 의한 은의 전류 적정)

  • Young Gu Ha;Q. Won Choi
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.2
    • /
    • pp.126-129
    • /
    • 1973
  • An amperometric method has been developed for the titration of silver with 2,5-dimercapto-1,3,4,-thiadiazole in ammonical solution (1N) using rotating platinum electrode as an indicator electrode and the mercury-mercury (II) iodide as reference electrode. Direct titration of milligram amount of silver (0.05-1.0mg) is possible in the presence of a number of foreign ions in ammonical solution containing ethylenediaminetetraacetic acid as masking agent under atmosphere. The interfering elements are gold and platinum. The milligram amount of silver can be determined by the proposed method within an error ${\pm}3{\%}$.

  • PDF

New Type of Collision Attack on Power-Analysis Resistant AES (전력 분석에 안전한 AES에 대한 새로운 종류의 충돌쌍 공격)

  • Kim, HeeSeok;Park, Hark-Soo;Hong, Seokhie
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.9
    • /
    • pp.393-398
    • /
    • 2013
  • This paper introduces a new collision attack on first-order masked AES. This attack is a known plaintext attack, while the existing collision attacks are a chosen plaintext attack. In addition, our method is more efficient than the second-order power analysis and requires about 1/27.5 power measurements by comparison with the last collision attack. Some experiment results of this paper support this fact. In this paper, we also introduce a simple countermeasure, which can protect against our attack.

Passports Recognition Using ART2-Based RBF Network (ART2 기반 RBF 네트워크를 이용한 여권 인식)

  • Kim Kwang-Baek;Oh Am-Suk
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.5
    • /
    • pp.700-706
    • /
    • 2005
  • The immigration control system authorizes the immigration of travelers by means of passport inspections such as the judgment of forged passports, the search for a wanted criminal or a person disqualified for immigration, etc. The judgment of forged passports plays an important role in the immigration control system. Therefore, as the pre-phase for the judgment of forged passports, this paper proposed a novel method for the recognition of passport using ART2-based RBF network. The proposed method extracts the area of code and individual codes by applying the Sobel masking, the smearing and the contour tracking algorithm in turn to the passport image. This paper proposed the RBF network that applies the ART2 algorithm to the middle layer, and applied the enhanced RBF network to the recognition of individual codes. The results of the experiments for performance evaluation on the real passport images showed that the proposed method has the better performance compared with other approaches.

  • PDF

Rapid Determination of Electroplating Solutions (1) -Copper from Copper Plating Solutions (각종 도금액의 신속분석법 (제 1 보))

  • 염희택
    • Journal of the Korean institute of surface engineering
    • /
    • v.1 no.1
    • /
    • pp.5-13
    • /
    • 1967
  • Up to this date, numerous methods of analysis of electropling solutions are published. Some, however, need lots of works before reaching final results, or require high technique and special instruments, and also some are unaccurate due to unclearnes of end point. Like our undevelop countries, technicians of electroplating shops are most high school graduates or under, and have not much knowledge on chemistry. Furthermore, those technicians have to control their plating solutions by themselves without having enough analytical laboratory equipment . Therefore, in this paper the simplest, besides accurate method is investigated after comparing numerous methods published. Among the methods of copper determinations from acid and alkaline copper plating baths, EDTA titration method are chosen, due to these methods are the simpest and fastest for the evaluation of metal content, without requirng any special instrument. For acid copper solutions, chelate titrations were accurate enough. Since the end point of titration of chelate method is variable according to the kind of indicators and other metal's coexisitence as well as solution component, many difficulties were encountered from cyanide copper, on the contrary of acid copper bath. PAN , PV, and MX indicators were tried , but it is found that MX is the best. In chyanide solution ,due to cyanide is the masking reagent , elimination of this component is essential , and finally found that elimination CN-by precipitation with AgNO$_3$ solution was the simplest and the most accurate way among others. This method was very accurate for the new plating solutions even coexistence with organic brightners. However used solutions for long months running have to be predetermined the accurate copper value by thiosulfate method form time to time, before chelate titration by means of AgNO$_3$ precipitation. Always some constant deviations will be seen according to the solutions nature. Therefore those deviation values have to be compensated each time.

  • PDF

연구논문 초록(1967~1978)

  • 한국표면공학회
    • Journal of the Korean institute of surface engineering
    • /
    • v.16 no.4
    • /
    • pp.199-214
    • /
    • 1983
  • Up to this date, numerous methods of analysis of electroplating solutions are published. Some, however, need lots of works before reaching final results, or require high technique and special instruments, and also some are unaccurate due to unclearnes of end point. Like our undevelope countries, technicians of electoplating shops are most high school gradutes or under, and have not much knowledge on chemistry. Furthermore, those technicians have to control their plating solutions by themselves without having enough analytical laboratory equiIJment. Therefore, in this paper the simplest, besides accurate method is investigated after comparing nu.merous methods published. Among the methods of 'copper determinations from acid and alkaline copper plating baths, EDT A titration method are chosen, due to these methods are the simplest and fastest for the evaluation of metal content, without requiring any special instrument. For acid copper solutions, chelate titrations were accurate enough. Since the end point of titration of chelate method is variable according to the kind of .indicators androther metal's coexsistence as well as solution comIJonent, many difficulties were encountered from cyanide' copper, on the contrary of acid copper bath. PAN, PV, and MX indicators were tried, but it is found that MX is the best. In cyanide solution, due to cyanide is the masking reagent, elimination of this component is essential, and finally found that elimination eN- by precipitation with AgN03 solution was the simplest and the most accurate way among others. This method was very accurate for the new plating solutions even coexistence with organic brightners. However used solutions for long months running have to be predetermined the accurate copper value by thiosulfate method from time to time, before chelate titration by means of AgN03 precipitation. Always some constant deviatioJ;ls will be seen according to the solutions nature. Therefore those deviation values have to be compensated each time.

  • PDF

NDVI Noise Interpolation Using Harmonic Analysis (조화 분석을 이용한 식생지수 보정 기법에 관한 연구)

  • Park, Soo-Jae;Han, Kyung-Soo;Pi, Kyoung-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.4
    • /
    • pp.403-410
    • /
    • 2010
  • NDVI(Normalized Difference Vegetation Index), which is broadly used as short-term data composite, is an important parameter for climate change and long-term land surface monitoring. Although atmospheric correction is performed, NDVI dramatically appears several low peak noise in the long-term time series. They are related to various contaminated sources, such as cloud masking problem and wet ground condition. This study suggests a simple method through harmonic analysis for reducing NDVI noise using SPOT/VGT NDVI 10-day MVC data. The harmonic analysis method is compared with the polynomial regression method suggested previously. The polynomial regression method overestimates the NDVI values in the time series. The proposed method showed an improvement in NDVI correction of low peak and overestimation.