• Title/Summary/Keyword: Testing facility

Search Result 294, Processing Time 0.024 seconds

Simple Synthetic Testing Facility Using LC Resonance Circuit (LC 공진회로를 이용한 간이 합성시험설비)

  • Park, J.H.;Shin, Y.J.;Park, K.Y.;Ryu, H.G.;Kim, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.631-635
    • /
    • 1993
  • This paper shows the procedure to determine the physical variables of the simple synthetic testing facility using LC resonance circuit and presents the calculated results of those variables for the LC resonance circuit which can be used to test circuit breakers up to 36kV 40kA class. Attention has also been paid to the advantages of the LC resonance circuit compared with the method adopting short-circuit generator for the development of circuit breakers.

  • PDF

Failure Evaluation Plan of a Reactor Internal Components of a Decommissioned Plant

  • Hwang, Seong Sik;Kim, Sung Woo;Choi, Min Jae;Cho, Sung Hwan;Kim, Dong Jin
    • Corrosion Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.189-195
    • /
    • 2021
  • A technology for designing and licensing a dedicated radiation shielding facility needs to be developed for safe and efficient operation an R&D center. Technology development is important for smooth operation of such facilities. Causes of damage to internal structures (such as baffle former bolt (BFB) of pressurized water reactor) of a nuclear power reactor should be analyzed along with prevention and countermeasures for similar cases of other plants. It is important to develop technologies that can comprehensively analyze various characteristics of internal structures of long term operated reactors. In high-temperature, high-pressure operating environment of nuclear power plants, cases of BFB cracks caused by irradiated assisted stress corrosion cracks (IASCC) have been reported overseas. The integrity of a reactor's internal structure has emerged as an important issue. Identifying the cause of the defect is requested by the Korean regulatory agency. It is also important to secure a foundation for testing technology to demonstrate the operating environment for medium-level irradiated testing materials. The demonstration testing facility can be used for research on material utilization of the plant, which might have highest fluence on the internal structure of a reactor globally.

Effects of Human Safety due to Leakage Current by Outdoor Electrical Facility in the Submerged Condition(I) (옥외 전기시설물 침수시 누설전류에 의한 인체영향(I))

  • Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Hyeong;Bae, Jeong-Hyo;Lee, Ji-In;Kim, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.244-246
    • /
    • 2002
  • In this paper, We studied about effects of human safety due to leakage current on the point of cable connection for outdoor electrical facility in the submerged condition and conducted its evaluation in the testing field. In this case, the reason of leakage on the point of cable connection is caused by formation of electrical pass between the grounded outdoor electrical facility and the enclosure of electrical facility which is connected to grounding system.

  • PDF

Effects of Human Safety due to Leakage Current by Outdoor Electrical Facility in the Submerged Condition(II) (옥외 전기시설물 침수시 누설전류에 의한 인체영향(II))

  • Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong;Bae, Jeong-Hyo;Lee, Ji-In;Kim, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.247-249
    • /
    • 2002
  • In this paper, We studied, about effects of human safety due to leakage current on the point of cable connection for outdoor electrical facility in the submerged condition and conducted its evaluation in the testing field. In this case, the reason of leakage on the point of cable connection is caused by formation of electrical pass between the grounded outdoor electrical facility and the other outdoor electrical facility which is disconnected to grounding system.

  • PDF

A Study on the Optimal Facility Layout Design Using an Improved Genetic Algorithm (개선된 유전자 알고리즘을 이용한 최적 공간 배치 설계에 관한 연구)

  • 한성남;이규열;노명일
    • Korean Journal of Computational Design and Engineering
    • /
    • v.6 no.3
    • /
    • pp.174-183
    • /
    • 2001
  • This study proposes an improved genetic algorithm (GA) to derive solutions for facility layout problems having inner walls and passages. The proposed algorithm models the layout of facilities on a flour-segmented chromosome. Improved solutions are produced by employing genetic operations known as selection, crossover, inversion, mutation, and refinement of these genes for successive generations. All relationships between the facilities and passages are represented as an adjacency graph. The shortest path and distance between two facilities are calculated using Dijkstra's algorithm of graph theory. Comparative testing shows that the proposed algorithm performs better than other existing algorithm for the optimal facility layout design. Finally, the proposed algorithm is applied to ship compartment layout problems with the computational results compared to an actual ship compartment layout.

  • PDF

The study on construction of the practical testing ground of grid-connected photovoltaic system (태양광발전 계통연계 실증시험장 구축에 관한 연구)

  • Kim, Euihwan;Jang, Juyeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • Currently the variety of governmental business support and research for supplying solar energy have been actively progressed. As of now, however, There are no practical testing infrastructures of grid-connected photovoltaic system which test performance of solar power facility in domestic. Therefore, in KEPRI, there is in progress construction of practical testing ground of 500 kW class grid-connected PV System for developing the evaluation of the performance technology including the Module, PCS, and etc, that is the important instrument of the PV System, in Gochang area. It analyzed the site creation work for constructing the practical testing ground and new construction of control room and the unit standards, specifications and capacity of required equipment. For the system detailed design, configuration, instrument-specific parameters established, power generation predictions of Array Type and the components of testing ground are needed to build.

  • PDF

Development of the Scale Track to Test Bogie Steering Performance (대차 조향 특성 시험을 위한 축소 트랙 개발)

  • Hur, Hyun-Moo;Park, Jun-Hyuk;You, Won-Hee;Park, Tae-Won
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.301-305
    • /
    • 2007
  • The performance of the railway bogie is classified into the stability and the steering performance. Testing for the bogie stability is conducted on the roller rig. But testing for the bogie steering performance on test facility is very difficult, so the testing for the vehicle curving performance is conducted on the real curve track. And it is desirable to test on the full scale test rig, but it caused many problems relating to test costs, test time. To overcome these problems, the small scale test rig is actively used in the field of bogie stability. Thus, in this paper, we have studied the scale track to test the bogie steering performance. For this, we designed the 1/5 scale test track equivalent to radius 200 curve and confirmed the validity of the testing for the bogie steering performance on the scale curve track through the testing using 1/5 scale bogie.

  • PDF

A Study on the Architectural Design of the PTF(Protocol Test Facility) and X.25 Packet Level Test (PTF(Protocol Test Facility)의 구조 설계 및 X.25 Packet Level Test)

  • 최양희;진병문
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.10 no.5
    • /
    • pp.240-249
    • /
    • 1985
  • This paper proposes the requirements of protocol testing, the protocol test methods and the architecture of PTF. Also this paper includes the test sequences and the test results for X.25 DTE packet level protocol.

  • PDF

A Hardware-In-the Loop Simulation technique for an IR guided weapon (적외선 유도무기 모의비행시험 기법)

  • 김영주;김민희;조규필
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.466-470
    • /
    • 1993
  • A HILS(Hardware-In-the-Loop Simulation) technique for an IR guided weapon is proposed. The IR HILS facility functions as a testing unit for a missile guidance and control system to evaluate target acquisition, tracking, and countermeasure performance. The configuration of IR HILS facility, modeling technique of an IR environment including target, background and countermeasure, and test and evaluation procedure are included.

  • PDF