• Title/Summary/Keyword: Test procedures

Search Result 1,857, Processing Time 0.037 seconds

A Case Study for Quality Confirmation and Maintenance Monitoring of Tunnel Underpassing the Han River (하저터널 품질확인 및 유지관리 계측 연구)

  • Woo, Jong Tae;Yang, Tae Seon;Koo, Jai Dong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.2
    • /
    • pp.185-194
    • /
    • 1998
  • This paper shows a case study on quality confirmation and maintenance monitoring of the tunnel underpassing the Han River. First of all, when it comes to the quality confirmation, soil investigation techniques and shotcrete core test will be improved. On the construction stages, quality control procedures are needed. Second, on the maintenance monitoring, it is the main tool to control stability and safety of the tunnel structures throughout the construction period. On the geotechnical monitoring instrumentation, some considerations such as installation of monitoring sections in time, immediate base readings, adequate reading frequency, etc - shall be improved.

  • PDF

A Study on the Distribution of the Deterioration Factor for Three Pollutants in Motor Vechicle Emission Test (자동차(自動車) 배출(排出)가스 시험(試驗)에서 3 공해요소(公害要素)에 대한 변화요인(變化要因) (DF) 분포(分布)에 관한 연구(硏究))

  • Jo, Jae-Rip;Hwang, Ui-Cheol
    • Journal of Korean Society for Quality Management
    • /
    • v.15 no.2
    • /
    • pp.2-9
    • /
    • 1987
  • The Deterioration Factor (DF) for a single pollutant within an engine family is computed as the ratio of two points on a linear regression line describing durability vehicle test results as a function of accumulated mileage. It is inteded to represent the factor by which emissions will increase during the ''useful life" of a vehicle in the engine family. Here are discribed procedures for computing the DF and how consideration of the DF is included in the development for the motor vehicle emission certification process. This paper is aimed to develop the distribution of the DF for three pollutant and to estimate the parameter values for the distribution of the DF.

  • PDF

The uniaxial strain test - a simple method for the characterization of porous materials

  • Fiedler, T.;Ochsner, A.;Gracio, J.
    • Structural Engineering and Mechanics
    • /
    • v.22 no.1
    • /
    • pp.17-32
    • /
    • 2006
  • The application of cellular materials in load-carrying and security-relevant structures requires the exact prediction of their mechanical behavior, which necessitates the development of robust simulation models and techniques based on appropriate experimental procedures. The determination of the yield surface requires experiments under multi-axial stress states because the yield behavior is sensitive to the hydrostatic stress and simple uniaxial tests aim only to determine one single point of the yield surface. Therefore, an experimental technique based on a uniaxial strain test for the description of the influence of the hydrostatic stress on the yield condition in the elastic-plastic transition zone at small strains is proposed and numerically investigated. Furthermore, this experimental technique enables the determination of a second elastic constant, e.g., Poisson's ratio.

Shear bond failure in composite slabs - a detailed experimental study

  • Chen, Shiming;Shi, Xiaoyu;Qiu, Zihao
    • Steel and Composite Structures
    • /
    • v.11 no.3
    • /
    • pp.233-250
    • /
    • 2011
  • An experimental study has been carried out to reveal the shear-bond failure mechanism of composite deck slabs. Thirteen full scale simply supported composite slabs are studied experimentally, with the influence parameters like span length, slab depth, shear span length and end anchorage provided by steel headed studs. A dozen of strain gauges and LVDTs are monitored to capture the strain distribution and variation of the composite slabs. Before the onset of shear-bond slip, the longitudinal shear forces along the span are deduced and found to be proportional to the vertical shear force in terms of the shear-bond strength in the m-k method. The test results are appraised using the current design procedures. Based on the partial shear-bond connection at the ultimate state, an improved method is proposed by introducing two reduction factors to assess the moment resistance of a composite deck slab. The new method has been validated and the results predicted by the revised method agree well with the test results.

Box Feature Estimation from LiDAR Point Cluster using Maximum Likelihood Method (최대우도법을 이용한 라이다 포인트군집의 박스특징 추정)

  • Kim, Jongho;Yi, Kyongsu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.4
    • /
    • pp.123-128
    • /
    • 2021
  • This paper present box feature estimation from LiDAR point cluster using maximum likelihood Method. Previous LiDAR tracking method for autonomous driving shows high accuracy about velocity and heading of point cluster. However, Assuming the average position of a point cluster as the vehicle position has a lower accuracy than ground truth. Therefore, the box feature estimation algorithm to improve position accuracy of autonomous driving perception consists of two procedures. Firstly, proposed algorithm calculates vehicle candidate position based on relative position of point cluster. Secondly, to reflect the features of the point cluster in estimation, the likelihood of the particle scattered around the candidate position is used. The proposed estimation method has been implemented in robot operating system (ROS) environment, and investigated via simulation and actual vehicle test. The test result show that proposed cluster position estimation enhances perception and path planning performance in autonomous driving.

Analysis of Dynamic Fracture Behavior by Using Instrumented Charpy Impact Test (계장화 샬피 충격시험에 의한 동적 파괴거동 해석)

  • Lee, O.S.;Kim, S.Y.;Hong, S.K.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.12
    • /
    • pp.64-71
    • /
    • 1995
  • This investigation evaluates dynamic fracture characteristics of two alloy steels (STD-11 and STS-3) and a gray cast iron (GC-30). The dynamic fracture toughness of crack initiation and some of the dynamic fracturing characteristics were evaluated by using the instrumented Charpy impact testing procedures. It was found from experimental results for three kinds of materials that inertia force is directly proportional to impact velocity. The duration time of inertia force was found to be constant regardless of impact velocities in steel specimens.

  • PDF

Evaluation of Electric Pulp Test (EPT) as a Tool for Measurement of Dentinal Hypersensitivity (상아질 지각과민 측정 도구로서의 전기치수검사에 대한 평가)

  • Kim, Young-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.371-378
    • /
    • 2002
  • In this study, 40 hypersensitive teeth of 19 patients were investigated. The procedures performed were as follows: Before desensitization, EPT at occlusal third of buccal surface was done for the evaluation of pulp vitality and the EPT value was recorded for the reference value. And mechanical and thermal test was executed for the test of hypersensitivity. If the tooth responded to the above tests, we did EPT at the exposed surface, using toothpaste as a electrolite medium and recorded the EPT value at patient's response. After the tests had been done, desensitization procedures with Gluma(R) Desensitizer were performed according to the manufacturer's instructions. After desensitization, the same tests except EPT at occlusal third were repeated. All the 40 teeth responded positive before desensitization and negative after desensitization procedures. The EPT value at occlusal third ranged from 31 to 65 (48.9${\pm}$7.2). Before desensitization 34 teeth responded at EPT value of 2 and the remaining 6 teeth was in the range of 17 to 25. After desensitization all 40 teeth responded from 12 to 27 (19.6${\pm}$3.5). The 6 teeth responded at greater number than 2 before desensitization was in the range of 18 to 23. Within the limitations of this study we can conclude that: When a tooth with dentinal hypersensitivity responds to mechanical and thermal stimulation, the tooth shows very low resistance to electricity at the exposed surface while when a tooth is desensitized and doesn't show respond to mechanical and thermal stimuli, the tooth shows increased level of resistance to electric stimulation at the exposed surface. EPT can be used for the diagnosis of dentinal hypersensitivity. Furthermore EPT will be useful to evaluate the outcome of desensitization procedures. However, EPT is not a valid tool for measuring dentinal hypersensitivity.

Evaluation of Patient Radiation Doses Using DAP Meter in Interventional Radiology Procedures (인터벤션 시술 시 면적선량계를 이용한 환자 방사선 선량 평가)

  • Kang, Byung-Sam;Yoon, Yong-Su
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.27-34
    • /
    • 2017
  • The author investigated interventional radiology patient doses in several other countries, assessed accuracy of DAP meters embedded in intervention equipments in domestic country, conducted measurement of patient doses for 13 major interventional procedures with use of Dose Area Product(DAP) meters from 23 hospitals in Korea, and referred to 8,415 cases of domestic data related to interventional procedures by radiation exposure after evaluation the actual effectives of dose reduction variables through phantom test. Finally, dose reference level for major interventional procedures was suggested. In this study, guidelines for patient doses were $237.7Gy{\cdot}cm^2$ in TACE, $17.3Gy{\cdot}cm^2$ in AVF, $114.1Gy{\cdot}cm^2$ in LE PTA & STENT, $188.5Gy{\cdot}cm^2$ in TFCA, $383.5Gy{\cdot}cm^2$ in Aneurysm Coil, $64.6Gy{\cdot}cm^2$ in PTBD, $64.6Gy{\cdot}cm^2$ in Biliary Stent, $22.4Gy{\cdot}cm^2$ in PCN, $4.3Gy{\cdot}cm^2$ in Hickman, $2.8Gy{\cdot}cm^2$ in Chemo-port, $4.4Gy{\cdot}cm^2$ in Perm-Cather, $17.1Gy{\cdot}cm^2$ in PCD, and $357.9Gy{\cdot}cm^2$ in Vis, EMB. Dose referenece level acquired in this study is considered to be able to use as minimal guidelines for reducing patient dose in the interventional radiology procedures. For the changes and advances of materials and development of equipments and procedures in the interventional radiology procedures, further studies and monitorings are needed on dose reference level Korean DAP dose conversion factor for the domestic procedures.

A Performance Evaluation of Zone Smoke Control Systems for Railway Underground Transit Passage by Smoke Control TAB (제연 TAB를 통한 철도 지하환승통로의 거실제연설비 성능평가)

  • Seol, Seok-Kyun;Kim, Joon-Hwan;Park, Min-Seok;Oh, Seung-Min;Ahn, Yong-Chul;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • This study conducted Testing, Adjusting, and Balancing (TAB), which is a type of field performance evaluation experiment of a zone smoke-control system, at a railway underground transit passage installed with a zone smoke- control system to find problems and improvements for ensuring performance. TAB for the smoke control system was classified into several procedures, such as design data review, duct leakage test, field measurement of the airflow rate, velocity of the fan and duct, and a smoke test. Through the duct leakage test, the system leakage ratio was examined to prove the duct sealing. The iImprovement of the smoke control airflow problems due to the lack of fan static pressure loss was the secured performance. The performance of the smoke control fan was secured by improvements of the smoke control airflow rate problems caused by the loss of static pressure in the intake duct. The smoke test in the smoke control zone confirmed that the damper operating schedule subject was influenced by natural wind or train wind.

Consideration of MIL-STD-810G Explosive Atmosphere Test for Fighter Aircraft (전투기의 MIL-STD-810G 폭발성 대기 시험에 관한 고찰)

  • Lee, Jae-Won;Jung, Seung-Bum;Hwang, Young-Ha;Ko, Jeong-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.10
    • /
    • pp.739-745
    • /
    • 2022
  • In various environmental requirements of a fighter aircraft, the explosive atmosphere is a test to verify whether or not military products are ignited for the safety of the aircraft system and crew. For the test, the explosive atmosphere test chamber owned by the Korea Institute of Industrial Technology (KITECH) was applied, and n-hexane, which has more sensitive ignition characteristics than general fuel, was used to conduct the test conservatively. Based on Procedure I, Method 511.6, MIL-STD-810G w/Change 1, the US military environmental test specification, the scope of application, tailoring guide, and detailed test procedures are checked, and the necessity of this test for each subsystem of the fighter aircraft is considered. In this study, we present the correct tailoring method by analyzing the explosive atmosphere test results for the components installed in the fighter aircraft and sharing the derived essential points.