• 제목/요약/키워드: Test procedures

검색결과 1,857건 처리시간 0.032초

SAMPLING BASED UNCERTAINTY ANALYSIS OF 10 % HOT LEG BREAK LOCA IN LARGE SCALE TEST FACILITY

  • Sengupta, Samiran;Dubey, S.K.;Rao, R.S.;Gupta, S.K.;Raina, V.K
    • Nuclear Engineering and Technology
    • /
    • 제42권6호
    • /
    • pp.690-703
    • /
    • 2010
  • Sampling based uncertainty analysis was carried out to quantify uncertainty in predictions of best estimate code RELAP5/MOD3.2 for a thermal hydraulic test (10% hot leg break LOCA) performed in the Large Scale Test Facility (LSTF) as a part of an IAEA coordinated research project. The nodalisation of the test facility was qualified for both steady state and transient level by systematically applying the procedures led by uncertainty methodology based on accuracy extrapolation (UMAE); uncertainty analysis was carried out using the Latin hypercube sampling (LHS) method to evaluate uncertainty for ten input parameters. Sixteen output parameters were selected for uncertainty evaluation and uncertainty band between $5^{th}$ and $95^{th}$ percentile of the output parameters were evaluated. It was observed that the uncertainty band for the primary pressure during two phase blowdown is larger than that of the remaining period. Similarly, a larger uncertainty band is observed relating to accumulator injection flow during reflood phase. Importance analysis was also carried out and standard rank regression coefficients were computed to quantify the effect of each individual input parameter on output parameters. It was observed that the break discharge coefficient is the most important uncertain parameter relating to the prediction of all the primary side parameters and that the steam generator (SG) relief pressure setting is the most important parameter in predicting the SG secondary pressure.

소형경유트럭의 하이브리드 튜닝 안전성에 관한 연구 (A Study on the Safety of Hybrid Tuning for Light-duty Diesel Trucks)

  • 전상우;권만재;안호순
    • 자동차안전학회지
    • /
    • 제13권4호
    • /
    • pp.20-25
    • /
    • 2021
  • This paper is the result of a research on hybrid tuning technology developed to improve the actual fuel efficiency and reduce emissions of in-use light-duty diesel trucks. In this study, a hybrid powertrain was constructed by inserting an electric motor between the diesel engine and manual transmission of an internal combustion engine vehicle and installing a battery. To verify the safety, a test was conducted based on the Korean tuning regulations. In particular, since there has been no case of tuning an internal combustion engine vehicle into a hybrid vehicle in Korea, it was necessary to carry out all procedures to receive tuning approval. The approval process consists of a technical review, safety verification test, and application for tuning approval. As a result, the test vehicle was approved for tuning because both the technical review and vehicle test results were suitable. Therefore, this study confirmed the safety of diesel hybrid tuning technology, and laid the foundation for the research and development of technologies to tune into an eco-friendly vehicle as well as the activation of related industries.

Proof tests of REBCO coated conductor tapes for device applications through electromechanical property assessment at 77 K

  • Mark Angelo Diaz;Michael De Leon;Hyung-Seop Shin;Ho-Sang Jung;Jaehun Lee
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권3호
    • /
    • pp.34-37
    • /
    • 2023
  • The practical application of REBCO coated conductor (CC) tapes, vital for energy transmission (e.g., cable application) and high-field magnets (e.g., coil application), necessitates efficient and simple quality assessment procedures. This study introduces a systematic approach to assess the electromechanical properties of REBCO CC tapes under 77 K and self-field conditions. The approach involves customized tensile and bending tests that clarify the critical current (Ic) response of the CC tapes under mechanical loads induced by tension and bending. This study measures the retained Ic values of commercially available GdBCO CC tapes under 250 MPa tensile stress and 40 mm bending diameter. Through experimentation, the study demonstrates the resilience of these tapes and their suitability for applications. By presenting a simplified stress-based analysis and a bending test of the tapes, the study contributes to effective quality assessment methods for the development of practical superconducting products.

환경적 간호중재가 개심술 환자의 중환자실섬망증, 환경적 스트레스 및 수면에 미치는 효과 (The Effect of the Environmental Nursing Intervention on ICU Delirium, Environmental Stress and Sleep in Patients Underwent Cardiac Surgical Procedures)

  • 장인실;최미혜
    • 임상간호연구
    • /
    • 제14권2호
    • /
    • pp.127-138
    • /
    • 2008
  • Purpose: To examine the effects of the environmental nursing intervention using eye-shields and earplugs on the incidence of delirium, environmental stress and sleep among the patients with open-heart surgery in the post-cardiac ICU(intensive care units). Method: This study was a non-equivalent control group non-synchronized design. The subjects consisted of 93 patients who received ICU care after the cardiac surgery. Among those, 32 subjects was assigned in one experimental group with eye-shields, 31 in the other experimental group with earplugs, and 30 in the control group. ICU delirium was measured by CAM-ICU, environmental stress by ICUESS, and sleep by two sleep scales developed by Oh, et al. and Kim. The data were analyzed by the SPSS 13.0 program including frequency, percentage, t-test, $x^2$ test, ANOVA and ANCOVA. Results: There are no statistically significant differences in the incidence of delirium among three groups (p=.139). The ICU environmental stress scores from the subjects of two experimental groups demonstrated lower (F=6.731, p=.002) than the control group. Also, the degrees of sleep pattern (p=.000, p=.000) and sleep satisfaction (p=.000, p=.000) were greater than those of the control group. Conclusion: Although the environmental nursing intervention using eye-shields and earplugs did not demonstrate the effects in decreasing the incidence of ICU delirium, it has affirmative effects in decreasing environmental stress and improving the quality sleep among the patients with open-heart surgery while they stay in ICU. Further nursing implications are discussed.

  • PDF

Effect of missing values in detecting differentially expressed genes in a cDNA microarray experiment

  • Kim, Byung-Soo;Rha, Sun-Young
    • Bioinformatics and Biosystems
    • /
    • 제1권1호
    • /
    • pp.67-72
    • /
    • 2006
  • The aim of this paper is to discuss the effect of missing values in detecting differentially expressed genes in a cDNA microarray experiment in the context of a one sample problem. We conducted a cDNA micro array experiment to detect differentially expressed genes for the metastasis of colorectal cancer based on twenty patients who underwent liver resection due to liver metastasis from colorectal cancer. Total RNAs from metastatic liver tumor and adjacent normal liver tissue from a single patient were labeled with cy5 and cy3, respectively, and competitively hybridized to a cDNA microarray with 7775 human genes. We used $M=log_2(R/G)$ for the signal evaluation, where Rand G denoted the fluorescent intensities of Cy5 and Cy3 dyes, respectively. The statistical problem comprises a one sample test of testing E(M)=0 for each gene and involves multiple tests. The twenty cDNA microarray data would comprise a matrix of dimension 7775 by 20, if there were no missing values. However, missing values occur for various reasons. For each gene, the no missing proportion (NMP) was defined to be the proportion of non-missing values out of twenty. In detecting differentially expressed (DE) genes, we used the genes whose NMP is greater than or equal to 0.4 and then sequentially increased NMP by 0.1 for investigating its effect on the detection of DE genes. For each fixed NMP, we imputed the missing values with K-nearest neighbor method (K=10) and applied the nonparametric t-test of Dudoit et al. (2002), SAM by Tusher et al. (2001) and empirical Bayes procedure by $L\ddot{o}nnstedt$ and Speed (2002) to find out the effect of missing values in the final outcome. These three procedures yielded substantially agreeable result in detecting DE genes. Of these three procedures we used SAM for exploring the acceptable NMP level. The result showed that the optimum no missing proportion (NMP) found in this data set turned out to be 80%. It is more desirable to find the optimum level of NMP for each data set by applying the method described in this note, when the plot of (NMP, Number of overlapping genes) shows a turning point.

  • PDF

NIR - a Tool for Evaluation of Milling Procedure

  • Gergely, Sziveszter;Handzel, Lidia;Zoltan, Andrea;Salgo, Andras
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1125-1125
    • /
    • 2001
  • Micro-scale test methods are producing small-sample size where the conventional physical and chemical tests can not be used (high standard deviation, uncertain sampling conditions, low repeatability). Different small-scale test methods were developed recently for determination of physico-chemical, functional, rheological properties of wheat or wheat dough using miniaturized instruments with sophisticated sample preparation/handling and mechanics (RVA, 2 g mixograph, micro-Z-arm mixer, small-scale noodle maker, micro-baking method etc.). The small-scale methodologies can be used as basic research tools or as technology supported measurements and can be also essential in the early selection for quality traits in breeding programs. The milling as a sample preparation step is essential procedure providing good quality flour or semolina samples from small amount of grain (5-10 g) in a reproducible and reliable way. The aim of present study was to use NIR as quality control tool, and to evaluate the recently developed and manufactured micro-scale lab mill (FQC-2000) produced by Inter-Labor Co. Ltd., Hungary. The milling characteristics of the new instrument were compared to other laboratory mills and the effects of milling action on the chemical composition of fractions were analysed. The fractions were tested with both chemical and near infrared spectroscopic methods. The micro-scale milling resulted significantly different yields, particle size distributions and different fractions from compositional point of view. The near infrared spectra were sensitive enough to distinguish the fractions obtained by different milling procedures. Quantitative NIR calibration equations were developed and tested in order to measure the chemical composition of characteristic milling fractions. Special qualification procedure the PQS (Polar Qualification System) method was used for detecting the differences between fractions obtained by macro and micro-milling procedures. The results and the limitations of PQS method in this application will be discussed.

  • PDF

안전필수항행시스템의 시험평가 프로세스 (T&E Process for Safety-Critical CNS/ATM Systems)

  • 강자영;김무근;김영훈;임인규
    • 한국항행학회논문지
    • /
    • 제21권1호
    • /
    • pp.50-57
    • /
    • 2017
  • 최근 국내에서 추진된 항공 관련 안전필수시스템 기술 개발 사업들이 중도에 종료되거나 최종 단계에서 실용화되지 못하는 사례가 종종 발생했다. 사업실패의 원인은 여러 가지 요인이 있겠지만 본 연구에서는 불완전한 시험평가 절차에 주안점을 두고 관련 연구를 수행하였다. 일반적으로 안전필수시스템의 시험평가 프로세스는 시스템의 전 수명주기에 걸쳐 분포되고 단계별 연속성을 가져야 하며 시스템 설계 및 획득 전략의 성숙도에 따라 다양한 방법으로 실행될 수 있다. 본 논문의 목적은 국내 안전필수 항행시스템 개발 사업의 리스크를 줄이고 성공률을 높이기 위한 방안으로 국내외 시험평가 프로세스를 분석하여 새로운 전략을 제시하는 것이다. 먼저 안전필수시스템에 대한 검증 및 확인 기법에 대해 토의하고 선진기관의 시험평가 프로세스 및 절차와 국내 현황을 분석한 뒤 국내외 시험평가 프로세스를 비교함으로써 불완전한 시험평가 절차에 대한 보완책을 제시하였다.

조리냉동 및 냉장식품에 대한 도시주부의 이용실태 및 인식정도와 식품제조업체의 의식구조 조사에 관한 연구 (Consumer Demands for Prepared Frozen or Refrigerated Foods and Industry′s Response to Consumer Demands)

  • 곽동경;이경애;류은순
    • 한국식품조리과학회지
    • /
    • 제9권3호
    • /
    • pp.230-238
    • /
    • 1993
  • The objectives of this study were to provide the basic data for the consumer education and for the new product development by surveying housewives'demands concerning prepared frozen or refrigerated foods and by surveying industry's practices and opinions concerning new product development. 804 housewives and 14 manufacturing companies of prepared frozen or refrigerated foods were surveyed. Data from housewives were analyzed by using SPSS-X progrm in terms of $x^2$-test, one-way ANOVA, t-test. The results of study are summarized as follows : 1. Frozen dumpling, frozen meat, surimi, ham and sausage were identifed as the most frequently used food items by housewives. The mean storage period for either prepared frozen or refrigerated foods was less than 15 days. 2. Housewives with higher educational background showed the greater concerns in packing and sanitary conditions, convenience in cooking procedures and brand name of the product than their counterparts. 3. Most housewives'purchasing motive for prepared frozen or refrigerated foods was the convenience of the cooking procedures(71.1%). Among the member of family, children(72.8%) specially liked prepared frozen or refrigerated foods. 4. Housewives'demands for prepared frozen or refrigerated foods were 'price reduction'and 'nutrition fortification'. These were in accordance with the companys'opimons. 5. Most wanting new product developments from the housewives perspectives were beverages (37.7%), stir-fried menu items(36.1%), pan-fried menu items(34.0%), stewed menu items(30.3%) and soups(20.4%). In case of stew and soups, the industry did not have a plan to develop those menu items.

  • PDF

원형 노치 CT 시편을 이용한 다양한 피로수명평가 절차의 보수성 평가 (Investigation into Conservatism of Various Fatigue Life Evaluation Procedures Using Round-Notched CT Specimens)

  • 강주연;장동주;김준영;김상언;이종민;허남수;김종성;김진원;김윤재;김대수
    • 한국압력기기공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.19-30
    • /
    • 2019
  • In this study, to evaluate conservatism of various fatigue life evaluation procedures, fatigue tests were conducted using compact tension (CT) specimens with a round notch, made of A516 Gr.70 carbon steel and A240 TP304 stainless steel, under load-controlled cyclic condition. Experimental fatigue failure cycles were measured and compared with predicted fatigue lives using two different life evaluation methods; (1) Design-By-Analysis (DBA) procedure given in ASME B&PV Code, Sec. III, Div. 1, Subsec. NB-3200 and (2) structural stress-based approach provided in ASME B&PV Code, Sec. VIII, Div. 2, Part 5. To predict fatigue failure cycles, three-dimensional elastic finite element analysis was conducted. Fatigue lives were predicted by both design fatigue curve given in ASME B&PV Code, Sec. III, Div. 1, Appendices and best-fit fatigue curve suggested in NUREG/CR-6815 for the DBA procedure. Finally, fatigue lives evaluated by various methods were compared with test results, and then conservatism between each evaluation procedure was discussed.

Influence of modification in core building procedure on fracture strength and failure patterns of premolars restored with fiber post and composite core

  • Kim, Young-Hoi;Lee, Jong-Hyuk
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.37-42
    • /
    • 2012
  • PURPOSE. The influence of the modified process in the fiber-reinforced post and resin core foundation treatment on the fracture resistance and failure pattern of premolar was tested in this study. MATERIALS AND METHODS. Thirty-six human mandibular premolars were divided into 4 groups (n = 9). In group DCT, the quartz fibre post (D.T. Light-post) was cemented with resin cement (DUO-LINK) and a core foundation was formed with composite resin (LIGHT-CORE). In group DMO and DMT, resin cement (DUO-LINK) was used for post (D.T. Lightpost) cementation and core foundation; in group DMO, these procedures were performed simultaneously in one step, while DMT group was accomplished in separated two steps. In group LCT, the glass fiber post (LuxaPost) cementation and core foundation was accomplished with composite resin (LuxaCore-Dual) in separated procedures. Tooth were prepared with 2 mm ferrule and restored with nickel-chromium crowns. A static loading test was carried out and loads were applied to the buccal surface of the buccal cusp at a 45 degree inclination to the long axis of the tooth until failure occurred. The data were analyzed with MANOVA (${\alpha}$= .05). The failure pattern was observed and classified as either favorable (allowing repair) or unfavorable (not allowing repair). RESULTS. The mean fracture strength was highest in group DCT followed in descending order by groups DMO, DMT, and LCT. However, there were no significant differences in fracture strength between the groups. A higher prevalence of favorable fractures was detected in group DMT but there were no significant differences between the groups. CONCLUSION. The change of post or core foundation method does not appear to influence the fracture strength and failure patterns.