• Title/Summary/Keyword: Test configuration

Search Result 1,238, Processing Time 0.029 seconds

Evaluation on the Lightning Breakdown Voltages of Palm Oil and Coconut Oil under Non-Uniform Field at Small Gap Distances

  • Thien, Yee Von;Azis, Norhafiz;Jasni, Jasronita;Kadir, Mohd Zainal Abidin Ab;Yunus, Robiah;Ishak, Mohd Taufiq;Yaakub, Zaini
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.184-191
    • /
    • 2016
  • In recent years, there are a number of studies that have been carried out to explore the alternative for Mineral Oil (MO) as dielectric insulating fluid in transformers due to the increasing tight regulation on safety and environment. Vegetable oils have been identified as suitable candidate since it is biodegradable, non-toxic and high flash/fire points which ensure more in-service safety. Among the types of vegetable oils considered for transformers application are Palm Oil (PO) and Coconut Oil (CO). This paper presents an experimental study on the lightning breakdown voltages of PO and CO under non-uniform electric field based on needle-sphere electrodes configuration at 3 small gap distances. The type of PO used in this study is Refined Bleached and Deodorized Palm Oil (RBDPO) Olein. The main focus of this study is to examine the lightning breakdown performance of RBDPO and CO under different test conditions and assess its suitability as dielectric insulating fluid in transformers. The effect of voltage polarities (positive and negative) and testing methods (rising-voltage, up-and-down and multiple-voltage) were investigated. The data obtained from all tests were analysed by Weibull distribution in order to determine the withstand voltages for each type of oils. It was found that the breakdown voltages of RBDPO and CO are comparable with MO under positive lightning impulse. Under negative lightning impulse, the breakdown voltage of MO is slightly higher than RBDPO and CO. There is no significant effect of testing methods and voltage polarities on lightning breakdown voltages of RBDPO and CO. Based on the statistical analysis, it is found that the breakdown voltages of RBDPO and CO at 1% probability are slightly lower than MO.

The Effects of Hyangsayukgunja-tang Extract on Indomethacin-Induced Gatric Mucosal Lesions (향사육군자탕(香砂六君子湯)의 Indomethacin 유발 위점막 손상에 대한 효과)

  • Baik, Tae-Hyun;Kong, Kyung-Hwan
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.4
    • /
    • pp.589-599
    • /
    • 2001
  • Objective: This study was carried out to investigate the effects of Hyangsayukgunja-tang extract on indomethacin-induced gastric mucosal lesions of mice. Methods: To evaluate the effects of Hyangsayukgunja-tang extract and Misoprostol, the morphology of gastric mucosa, and the distribution of mucose cells, PNA(Peanut Agglutinin), ICAM(intercellular adhesion molecule), and apoptotic cells were observed. Hyangsayukgunja-tang extract and Misoprostol were intragastric injected to the test groups at hour 72 before and just before indomethacin treatment(HYT-J, HYT-72, M-J, M-72), while the INDO group was injected only with indomethacin and the control group was subcutaneously injected only with saline. Results: The gastric mucosal lesions incresed in the fundus and body of INDO group, but softened in HYT group and M group, the effects were more excellent in the HYT-72, M-72 groups than the HYT-J, M-J groups and in the HYT group than M group. The disappearance of surface and neck mucose cells were shown in INDO group, but softened in HYT group and M group. The mucosal configuration of HYT-72 group was the same as control group. The numerical increase of PNA positive reaction in cytoplasm of perietal cells were appeared in INDO group. The PNA positive reaction in HYT group and Miso-group were shown in surface mucous cells and microvilli of apical surface in chief cells as control group, and were the same as control group in all mucosa of HYT-72 group. The distribution of ICAM positive cells, increased in INDO group, but decreased in M-72 group, and were the same as control group in HYT-72 group. The apoptotic cells, increased noticeably in gastric mucosa of INDO group, decreased in HYT group and M group, and decreased noticeably in HYT-72 group. Conclusions: Hyangsayukgunja-tang extract had excellent effects on indomethacin-induced gastric mucosal lesions.

  • PDF

Optimization of Position of Lightening Hole in 2D Structures through MLS basede Overset Metheod along with Genetic Algorithm (이동최소자승 중첩 격자 기법과 유전자 알고리듬을 이용한 2차원 구조물의 경감공 위치 최적 설계)

  • Oh, Min-Hwan;Woo, Dong-Ju;Cho, Jin-Yeon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.10
    • /
    • pp.979-987
    • /
    • 2008
  • In aerospace structural design, the position of lightening hole is often required to be optimized from the initial design in order to avoid an excessive stress concentration. To remodel the updated configuration in optimization procedure, re-meshing procedure is conventionally adopted. However, this approach is time-consuming, and has limitations especially in handling hexahedral or quadrilateral meshes, which are preferred because of their good numerical performances. To attenuate these disadvantages, new optimization scheme is proposed by combining the MLS(Moving Least Squares) based overset method and the genetic algorithm in this work. To test the validity of the proposed optimization scheme, optimizations of positions of lightening holes in 2D structures have been carried out.

A study of the system that enables real-time contact confirmation of probes in OLED panel inspection (OLED Panel 검사 시에 Probe의 실시간 Contact 확인 가능한 시스템에 관한 연구)

  • Hwang, Mi-Sub;Han, Bong-Seok;Han, Yu-Jin;Choi, Doo-Sun;Kim, Tae-Min;Park, Kyu-Bag;Lee, Jeong-woo;Kim, Ji-Hun
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.21-27
    • /
    • 2020
  • Recently, LCD (Liquid Crystal Display) has been replaced by OLDE (Organic Light Emitting Diode) in high resolution display industry. In the process of OLDE production, it inspects defective products by sending a signal using a probe during OLED panel inspection. At this time, the cause of the detection of failure is divided into two. One is the self-defect of the OLED panel and the other is the poor contact occurring in the process of contact between the two. The second case is unknown at the time of testing, which increases the time for retesting. To this end, we made a system that can identify in real time whether the probe is in contact during the inspection. A contact probe unit was designed for the system, and a stage system was implemented. An inspection system was constructed through S / W and circuit configuration for actual inspection. Finally, a system that can check contact and non-contact in real time was constructed.

Accuracy of Combined Block Adjustment with GPS-Permanentstation (GPS 연속관측점을 이용한 결합블럭조정의 정확도)

  • 박운용;이재원;신상철
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.17 no.1
    • /
    • pp.21-32
    • /
    • 1999
  • Mapping and precise point determination by photogrammetry have been shown to be an economic solution. But control points are necessary to determine the exterior orientation parameters. Although the number of required control points has been reduced based on extended bundle adjustment and reinforced cross-strip, the ground survey is a significant factor of whole expenses in photogrammetry. The status of GPS-photogrammetry with kinematic DGPS-positioning to overcome this disadvantages, is now steadly progressive since the first possibility has been proved. The completed satellite configuration, powerful receiver function and upgraded software for kinematic DGPS-positioning have extensively improved the accuracy of combined bundle adjustment. So the research for the operational use of GPS-photogrammetry is absolutely necessary. The presented test field was designed for identification of subsidences in a coal mining area, flown with 60% sidelap and cross strips. Just with 6 control points and combined block adjustment instead of the traditionally used 21 horizontal and 81 vertical control points the same ground accuracy has been reached. The accuracy of kinematic GPS-positioning and combined block adjustment was independent upon the distance of the ground reference station. It also has been showed that the special model for the systematic error correction in the combined block adjustment.

  • PDF

An SDN-based Bandwidth Control Scheme considering Traffic Variation in the Virtualized WLAN Environment (가상화된 WLAN 환경에서 트래픽 변화를 고려한 SDN 기반 대역폭 제어 기법)

  • Moon, Jaewon;Chung, Sanghwa
    • Journal of KIISE
    • /
    • v.43 no.11
    • /
    • pp.1223-1232
    • /
    • 2016
  • A virtual network technology can provide a network reflecting the requirements of various services. The virtual network can distribute resources of the physical network to each virtual slice. An efficient resource distribution technique is needed to reflect the requirements of various services. Existing bandwidth distribution techniques can only control downlink traffic without taking traffic conditions on the network into account. Downlink and uplink share the same resources in a wireless network. The existing bandwidth distribution techniques assumed that all stations generate saturated traffic. Therefore, the existing bandwidth distribution technique cannot make traffic isolation in a virtual wireless network. In this paper, we proposed a traffic-based bandwidth control techniques to solve these problems. We applied Software-Defined Networking(SDN) to the virtual wireless network, monitored the traffic at each station, and searched for stations that generated unsaturated traffic. We also controlled both uplink and downlink traffics dynamically based on monitoring information. Our system can be implemented with legasy 802.11 clients and SDN-enabled APs. After the actual test bed configuration, it was compared to existing techniques. As a result, the distribution performance of the proposed technique was improved by 14% in maximum.

Revitalization for a Cyber Home Learning System -Focused on Jeju e-study 2.0- (사이버가정학습 활성화 방안 -제주 e-study 2.0을 중심으로-)

  • Kim, Eun-Gil;Kang, Nam-Cheol;Kim, Jong-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.8
    • /
    • pp.451-460
    • /
    • 2010
  • The purpose of this paper is to present the effective operation method of cyber home learning system 2.0. Cyber home learning system 2.0 which plays an important role to produce and share data of internet users establishing user-centered internet environment is recently introduced as web 2.0 is beginning to appear. This research is based on the case of the operation on cyber home learning system, research literature of web 2.0 as well as expert consulting and performance test. After doing this research, cyber home learning system 2.0 can bring enormous educational effect when it has online education using web-based discussion tool and long distance consulting linking with off line school education. Redundant system configuration, the distributed processing also may be provided by the service was smooth. Moreover, it demands monitoring team consisting of student, parents and teacher in order to provide developmental service.

A Development of Ship Block Leveling System based on the Axiomatic Design (공리적 설계 기반 선체 블록 레벨링 시스템 개발)

  • Noh, Jackyou;Lim, Nam-Won;Oh, Jung-Keun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.2
    • /
    • pp.207-214
    • /
    • 2015
  • In this paper the independence axiom, one of two principal axioms of axiomatic design theory, is applied to the leveling system development as an design criteria. After functional requirements and corresponding design parameters constitute an initial design matrix for the leveling system, sequence, which is compatible with the independence axiom, of the design parameters of the design matrix is determined and independent components of block leveling system are revealed. As a result of axiomatic design, system configuration related to the design sequence is developed. In order to verify and validate the developed block leveling system, test with real hull block leveling work in site by using total station which is used to acquire three dimensional coordinate of target point is performed. Comparison with measured data and output data from the block leveling system shows the system accuracy is under 1 mm so that the developed system is verified and validated to be used in site.

A New Steady Approach to Predict the Transonic Buffet Onset (천음속 버펫 발단 예측을 위한 새로운 정상 접근 방법)

  • Jeong, In-Jae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.5
    • /
    • pp.12-18
    • /
    • 2006
  • A new steady approach has been developed to predict the transonic buffet onset of a high speed aircraft. In this paper, the flow is assumed to be steady for the buffet onset. The present study involves the analysis of a distinct change in the variation of various static aerodynamic parameters. These distinct changes indicates the onset of transonic buffet. Among the various aerodynamic parameters considered in this study, the variation in the center of pressure has shown to provide a clearest indicator of transonic buffet onset. This new steady approach can be applied to predict the transonic buffet onset for airfoils with shock induced separation bubble and for large swept wings with small aspect ratios. Good agreements have been obtained compared with unsteady wind tunnel buffet test data. Based on the results obtained the new steady approach, it can be newly suggested that the distinct slope changes of the center of pressure curve can be used as an indicator of buffet onset for the steady experimental method on a full aircraft configuration.

Redundancy Management Design for Triplex Flight Control System (3중 비행제어시스템의 다중화 기법 설계)

  • Park, Sung-Han;Kim, Jae-Yong;Cho, In-Je;Hwang, Byung-Moon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.169-179
    • /
    • 2010
  • Satisfying the same probability of loss of control and essentially two fail operative performance with a triplex computer architecture requires a lot of modification of the conventional redundancy management design techniques, previously employed in quadruplex digital flight control computer. T-50 FCS for triplex redundancy management design applied an advanced digital flight control architecture with an I/O controller which is functionally independent of the digital computer to achieve the same reliability and special failure analysis and isolation schemes for fail operational goals with a triplex configuration. The analysis results indicated that the triplex flight control system is to satisfy the safety requirement utilizing the advanced flight control techniques and the system performance of the implemented flight control system was verified by failure mode effect test.