Reliability Evaluation of an Oil Cooler for a High-Precision Machining Center

  • Lee, Seung-Woo;Han, Seung-Woo;Lee, Hu-Sang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.3
    • /
    • pp.50-53
    • /
    • 2007
  • Improving the reliability or long-term dependability of a system requires a different approach from the previous emphasis on short-term concerns. The purpose of this paper is to present a reliability evaluation method for an oil cooler intended for high-precision machining centers. The oil cooler system in question is a cooling device that minimizes the deformation caused from the heat generated by driving devices. This system is used for machine tools and semiconductor equipment. We predicted the reliability of the system based on the failure rate database and conducted the reliability test using a test-bed to evaluate the life of the oil cooler. The results provided an indication of the reliability of the system in terms of the failure rate and the MTBF of the oil cooler system and its components, as well as a distribution of the failure mode. These results will help increase the reliability of oil cooler systems. The evaluation method can also be used to determine the reliability of other machinery products.

Lubricity Evaluation of Gear Oil By SRV Tester (SRV를 사용한 기어유의 윤활성 평가)

  • Yun Hyukchae;Lee Kihun;Lee Myounggu;Cho Wonoh
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.181-184
    • /
    • 2003
  • The Four-Ball Tester has been widely used as a tool to charaterize lubricity for long time. In order to understand more acurate properties of lubricants, more test methods have been developed. Among the test methods, SRV test method was compared to Four-Ball Tester in this paper.

  • PDF

Performance Test of NYSC 1m Telescope by Photometric Observation of M35

  • Kang, Wonseok;Kim, Taewoo;Kwon, Sun-gill;Lee, Sang-Gak
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.63.3-63.3
    • /
    • 2016
  • NYSC 1m telescope is completely assembled now, and equipped with FLI PL-16803 4k CCD and Shelyak eShel spectrograph (R~10,000) on optical system of f/8. From 12th Jan 2016, optical system alignment and test observations have been performed. We present the result of M35 photometric observation for the performance test of the 1m telescope. The photometric observation was carried out for the central part of M35 with the field of view, ${\sim}15^{\prime}.8{\times}15^{\prime}.8$. Standard transformation to the UBVI system was done by the photometric data of M35 in Sung and Bessell(1999).

  • PDF

Reignition system for synthetic short-circuit test (합성단락시험용 재점호장치)

  • Park, Seung-Jae;Kim, Maeng-Hyun;Kang, Young-Sig;Shin, Young-June;Koh, Heui-Sek
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1856-1858
    • /
    • 2000
  • This paper describes the principles of reignition system which has newly been developed and used as KERI's high power testing facilities. Synthetic short-circuit testing method is generally adopted to perform the short-circuit test of the ultra high-voltage circuit breakers, which consists of two separated sources such as the current source from short-circuit generator and the voltage source from charged energy in capacitor. And, in case of synthetic short-circuit test, it will be necessary to use the reignition system in order to extending the arcing time of the circuit breaker and provide the arc energy equivalent to the direct testing method.

  • PDF

Construction of Reliability Assessment Infrastructure for Spacers in GIS (GIS용 절연스페이서 신뢰성령가기반 구축)

  • Lee, J.G.;Kim, M.K.;Kim, I.S;Jeong, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.180-181
    • /
    • 2006
  • In this paper, there have been brief review about the important consideration in laboratory planning and construction of the reliability assessment infrastructure including 400 kV, 120 kVA AC test system, which enable to evaluate the HV long-term overcharged withstand performance for spacers using in Gas Insulated Switchgears up to transmission class, Also it is described simply about its trial running of the whole test system and its assessment example. To inform the founded national code, RS C 0084, and the procedure for getting a reliability assessment certificate issued by the government, brief description of the code and summation of test results have been conducted.

  • PDF

The Combined Testing System for Simulating Condition of Acceleratedly Deteriorated Environment (전력기기 내환경특성평가를 위한 복합가속열화시스템 제작)

  • Lee, J.G.;Kim, M.K.;Kim, I.S.;Jeong, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.182-183
    • /
    • 2006
  • It has been studied about the important consideration in designing and construction of the reliability assessment facilities including the combined testing system for simulating condition of acceleratedly deteriorated environment, which enable to test and evaluate the large-sized HV power apparatus without any disassembly up to transmission class in this paper. Also it is described simply about its ratings and main technical specifications and trial running of the system. To evaluate the performance characteristics against combined test condition for various power installation, especially for the polymer type insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted.

  • PDF

Integer Programming Approach to the Convergence Adjustment on Color Display Tube

  • Park, Sungsoo;Kang, Donghan;Lee, Hyohyung;Hong, Cheol-Kee
    • Industrial Engineering and Management Systems
    • /
    • v.3 no.1
    • /
    • pp.63-70
    • /
    • 2004
  • In this paper, we consider the adjustment of convergence on Color Display Tube (CDT). Convergence is a measure of how well the red, green and blue beams are physically aligned with each other to strike the same area on the screen. When misconvergence (convergence error) occurs, one way of compensating it is to attach several ferrite sheets on the inner part of Deflection Yoke (DY). We suggest an optimization model of misconvergence compensation process and report test results for 81 DY samples. As a result, more than 90% of the samples could be made to satisfy the required convergence criteria.

A Study on the Improvement of the Water Source Energy Distribution Regulation for High Efficient Data Center Cooling System in Korea (데이터센터 냉방시스템 고효율화를 위한 국내 수열에너지 보급 제도 개선에 관한 연구)

  • Cho, Yong;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.3
    • /
    • pp.21-29
    • /
    • 2021
  • In this study, the current regulation of the water source energy, one of the renewable energy, was analyzed, and the improvement plan for the high efficient data center cooling system was suggested. In the improvement plan, the design and construction guidelines of the water source energy system permit to adopt the cooling and heating system with or without heat pump. In addition, it should also include the system operated in the cooling mode only all year-round. The domestic test standards to consider the water source operating conditions should be developed. Especially, it is highly recommended that the test standards to include the system with forced cooling and free cooling modes related with the enhanced data center cooling system adopting the water source energy.

Test Result Analysis of a 1MW HTS Motor for Industry Application

  • Baik, S.K.;Kwon, Y.K.;Kim, H.M.;Lee, E.Y.;Kim, Y.C.;Park, H.J.;Kwon, W.S.;Park, G.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.2
    • /
    • pp.33-36
    • /
    • 2009
  • A 1 MW class HTS (High-Temperature Superconducting) synchronous motor has been developed. This motor is aimed to be utilized for industrial application such as large motors operating in large plants. The HTS field coil of the developed motor is cooled by way of neon thermo siphonmechanism and the stator (armature) coil is cooled by water through hollow copper conductor. This paper also describes evaluation of some electrical parameters from performance test results of our motor, which was conducted at steady state in generator mode and motor mode. Open and short circuit tests were conducted in generator mode while a 1.1 MW rated induction machine was rotating the HTS machine. Electrical parameters such as mutual inductance and synchronous inductance are deduced from these tests. Load test was done upto rating torque during motor mode and efficiency was measured at each load torque.

The Study on the Acceleration Factor of Coastal Outdoor Corrosion test, Salt Spray Test and Accelerated Corrosion Test using 0.5wt% carbon steel (0.5wt% 탄소강을 이용한 해안 야외부식시험과 염수분무시험, 가속부식시험의 가속계수에 대한 연구)

  • Cho, E.Y.;Gwon, G.B.;Cho, D.H.;Kim, J.Y.
    • Corrosion Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.209-214
    • /
    • 2013
  • In the industry, accelerated corrosion test is used for the life time prediction. When anti-corrosion test proceeds in real environments, it is difficult that we predict and evaluate the corrosion life time because of the long test time such as 10 years or more time. Accelerated corrosion test and Salt spray test are able to test corrosion life time of products in the laboratory instead of outdoor corrosion test. Experimental procedure is selected for the corrosion standard specimen, exposure of the specimens, measurements of the mass loss and evaluating the mass loss data. As a result, the acceleration factor of the accelerated corrosion test to the outdoor corrosion test is 414.8. Therefore we can predict the corrosion life time of carbon steel during a short time period.