• 제목/요약/키워드: Test center

검색결과 13,272건 처리시간 0.047초

브레이크 열적 성능 평가를 위한 Virtual Test 기술의 개발 (Development of the Virtual Test Technology for Evaluating Thermal Performance of Disc Brake)

  • 최봉근;박종현;김미로;안병재
    • 한국자동차공학회논문집
    • /
    • 제17권4호
    • /
    • pp.40-47
    • /
    • 2009
  • There are many kinds of simplifications and limitations in evaluating thermal performance of disc brake using the analytic technologies which were established before. But now new virtual test technology with several advanced analytic techniques is developed to evaluate the thermal performance without any possibility of great errors that used to happen for the time-consuming analysis. As a result, it was estimated that the virtual test technology could afford to replace the physical dynamo test since the reliability of virtual test technology was reasonably verified with the existing data measured in dynamo test.

청국장 중 biogenic amine의 함량 및 생성원인 (Biogenic Amines Formation and Content in Fermented Soybean Paste (Cheonggukjang))

  • 한규홍;조태용;유명상;김천수;김정민;김현아;김미옥;김성철;이선애;고용석;김소희;김대병
    • 한국식품과학회지
    • /
    • 제39권5호
    • /
    • pp.541-545
    • /
    • 2007
  • 본 연구에서는 청국장에서 biogenic amine의 함량을 조사하고, 이를 생성하는 미생물의 스크리닝 및 biogenic amine 형성 등을 통하여 생성원인을 규명하고자 하였다. 그 결과 국내 시판 청국장에는 putrescine, histamine, tryptamine 등 11종의 biogenic amine이 검출되었으며, 이 중 tyramine이 $4.2{\pm}0.9-483.1{\pm}28.4mg/kg$의 범위를 보여주여 다른 amine에 비하여 높게 나타났다. 청국장내 균주는 B. amyloliquefaciens, B. subtilis, B. licheniformis 등이 분리 동정되었고, 이들 균주에 대한 탈탄산 효소 활성 스크리닝을 살펴본 결과 모두 양성(+) 반응을 보여주었다. 최종적으로 균주에 대한 biogenic amine 생성을 확인하였을 때, 청국장내 존재하는 균주가 탈탄산 효소 활성을 통하여 biogenic amine 생성하는 것을 확인할 수 있었다.

Design of an Altitude Test Facility for Turbo Shaft Engine

  • Choi, Young-Hwan;Park, Sang-Joon;Lee, Joon-Won;Kim, Chun-Taek;Cha, Bong-Jun;Ahn, Iee-Ki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.173-181
    • /
    • 2008
  • Gas turbine engine for aircraft are usually operated at the altitude condition which is quite different from the ground condition. In order to measure the precise performance data at the altitude condition, the engine should be tested at the altitude condition by a real flight test or an altitude simulation test with an altitude test facility. In this paper describes the design of altitude test facility for turbo shaft engine. This facility will be located in test cell #2 at the Korea Aerospace Research Institute. Test Cell #2 will be used for altitude testing engines with mass flow rate up to 40kg/s and inlet temperatures in the range from $-65^{\circ}C$ to $200^{\circ}C$. The existing compressor/exhauster station with heater & cooler system will be used to simulate altitude conditions in Test Cell #2.

  • PDF

Test Methods of Sealing Material for Plastic Liquid Crystal Display Cells

  • Hsiao, C.C.;Liao, Y.C.;Chang, K.H.;Sha, Y.A.;Su, P.J.;Hsieh, C.H.;Shiu, J.W.;Fuh, S.Y.;Lin, C.Y.;Cheng, W.Y.;Yang, J.C.;Lo, K.L.;Lee, D.W.;Lee, K.C.;Chang, Y.P.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.830-833
    • /
    • 2006
  • In this work, we provided a novel test method to verify the sealing materials for flexible LCD cell. The ultraviolet type curing sealing material with low process temperature was suitable for LCD cell assembly. We also proposed the sealing materials which passed 13200 times bending test within 20 mm curvature.

  • PDF

배전실증시험장의 구성 방안 및 운용 예상효과 분석 (A configuration plan and future expectation of a power distribution test)

  • 정영호;김상준;박상만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.829-831
    • /
    • 1997
  • We investigated configuration plan and future expectation of the power distribution test center. The example of foreign country's test center was analyzed, and the required test facilities, test line, and power source for the operation of our test center were proposed.

  • PDF

180kV HVDC 해저케이블 기계적/전기적 특성 평가 (Mechanical and Electrical Performance of 180kV HVDC Submarine Cable System)

  • 김남열;이태호;지봉기;이상진;김정년;전승익;윤희석;정수길;강채홍;안용호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.616-618
    • /
    • 2007
  • This paper describes the mechanical and electrical test on HVDC submarine cable, Flexible Repair Joint and termination for 180kV. This HVDC submarine cable was manufactured using LS cable's unique skill and would be applied the HVDC submarine cable system in korea. The performance test consist of mechanical test and electrical test. The tensile bending test and tensile test was done as the mechanical test and Electrical test is DC voltage and Impulse test. The tensile bending test carried out 6 times(double of specified times) for maximum reliability. The DC test voltage is $\pm$400kV/1hr. We estimate the lower limit of DC breakdown voltage is 600kV. The impulse test voltage is $\pm$800kV/10shots. The type of developed cables is the MI type. Its insulation consist of paper tapes impregnated with a high viscosity oil. The development of new HVDC cable is available for HVDC underground or submarine power transmission. The developed HVDC cable, FRJ and termination have passed the mechanical and electrical test successfully and showed excellent performance.

  • PDF

A point of confusion for embryologists in the identification of viable spermatozoa by the eosin-nigrosin test

  • Chen, Huanhua;Zhou, Hong;Shu, Jinhui;Gan, Xianyou;Wang, Caizhu;Lin, Ruoyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제46권1호
    • /
    • pp.36-40
    • /
    • 2019
  • A viable spermatozoon is a prerequisite for fertilization in intracytoplasmic sperm injection (ICSI). Thus, it is crucial to select viable but immotile spermatozoa on the day of ICSI. We report conflicting results in the identification of viable but immotile spermatozoa between the eosin-nigrosin staining and the laser test, which resulted in confusion for embryologists during assisted reproductive technology (ART). Three patients' semen samples that showed no motile spermatozoa are described in this report. To identify viable spermatozoa, we used both the eosin-nigrosin test and the laser test for each sample, and repeated the semen analysis twice in each patient. Viable but immotile spermatozoa selected by the laser test were used for ICSI. Viable spermatozoa were detected by both the eosin-nigrosin and laser tests in two patients (case 1, 95.00% vs. 24.21% and 92.68% vs. 22.22%; case 2, 41.18% vs. 23.48% and 39.81% vs. 22.52%), indicating consistent results between the two methods. In the third patient, the eosin-nigrosin test yielded viability rates of 20.75% and 19.14%, while the result of the laser test was 0%. Thus, testicular aspiration was performed to collect viable sperm from this patient. Normal fertilization was achieved after the injection of viable but immotile spermatozoa selected from these patients by the laser test, resulting in the birth of two healthy babies. Our study documents a case where the eosin-nigrosin test showed a limitation in identifying viable but immotile spermatozoa for ART, while the laser test may overcome this limitation. Larger samples may be required to corroborate the clinical value of the laser test.

시험시공 및 현장시험을 통한 C.S.G 공법의 적용성 검토 (Application study of C.S.G method by the test construction and field test)

  • 김기영;박한규;조성은;전제성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.61-68
    • /
    • 2006
  • Cemented Sand and Gravel(CSG) is a material made by simple mixing of rock-based raw materials such as excavated soil and riverbed gravel together with cement and water. The use of CSG methodl for cofferdam and large dam is gradually increasing in Japan because a quarry and aggregate plants can be diminished. Also, the CSG method can reduce dam construction cost, construction duration and destruction of environment. In this paper, field test and test construction of CSG method was conducted on Hwabuk Dam. The mechanical properties of CSG, such as compressive strength, extention strength and field permeability test were investigated. From the results of the experimental study, application study of CSG method was discussed.

  • PDF