• Title/Summary/Keyword: Test Tools

Search Result 1,805, Processing Time 0.027 seconds

Development Roadmap Analysis for Automatic Testing Tools of Software (소프트웨어 자동 테스팅 도구의 발전 로드맵 분석)

  • 정창신;정순기
    • Journal of the Korea Society of Computer and Information
    • /
    • v.9 no.1
    • /
    • pp.17-23
    • /
    • 2004
  • Testing tools help software developers and test engineers to automate a part or the whole of test process and reduce the time and cost of software test. However. no automatic tools meet a variety of test requirements with various domains In this paper, we suggest a categorical taxonomy of automatic testing tools and analyze numerous commercial testing tools on its basis. Then we propose a development roadmap of software automatic testing tools. As a result of those analysis. we try to understand the complementary relations of the testing tools and seek for the direction of further development of the testing tools.

  • PDF

Development of Scale Tools for Measure Programming Task Value and Learning Persistence at Elementary School Students

  • Kim, Ji-Yun;Lee, Tae-Wuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.9
    • /
    • pp.187-192
    • /
    • 2017
  • In this paper, we have studied scale tools for measure programming task value and learning persistence at elementary school students. In order to develop complete test tools, we have improved the completeness by revising tests through stepwise verification. The first scales were constructed based on the previous studies. As a result of the content validity test, 5 out of 14 items of the task value test tool and 1 out of 10 items of the learning persistence test were not suitable. The second test tools were constructed by revising and supplementing the first scale, and consisted of 13 items of task value and 8 items of learning persistence. As a result of the contents validity test, all the items included in the test tool proved to be valid. The reliability of the secondary testing tools were also found to be reliable at ${\alpha}=.970$ and ${\alpha}=.975$, respectively.

Review of S/W Test Automation Tools for the Improvement of the Software Quality (소프트웨어 품질 향상을 위한 테스트 자동화 도구에 관한 동향분석)

  • Jeong Seung-Hwan;Lee Keum-Suk;Kim Gi-Jong
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1477-1478
    • /
    • 2004
  • Science the change of development methods and environment of the software is rapidly kept going in industry, previous manual test methods will not be able to guarantee the quality of software. Therefore the software test automation tools is being developed actively. And many of the tools which is reliable is applied and used in domestic organizations. Indirect test techniques currently are used For the improvement of the software quality, such as formal specification and design, structural programming. And also the various do direct test techniques are used to the measurement of software quality through the fault detection and modification, such as black box, which box and test automation tools. In this survey, the software test automation tools which predicate and access the software quality at the software development phase for the improvement of the software quality should be introduced.

  • PDF

RELIABILITY TEST OF RFID TECHNOLOGY IN TOOL TRACKING

  • Julian Kang;Jae-Heon Nam
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.820-823
    • /
    • 2005
  • RFID technology offers the possibility that tools and valuable supplies tagged with RFID devices could be tacked down automatically. Such automated tool tracking has the potential to reduce theft, identify underutilized tools to be relocated, insure that crafts have access to the appropriate tools as needed, and reduce overhead labor cost of managing tools. Although other industries have been busy to enhance their supply chain management using RFID technology, construction professionals may be wondering whether it works reliably in construction jobsites as well. This paper presents a field test conducted to determine the reliability of RFID technology in identifying tools in the field storage box. The test indicated that RFID technology is reliable in inventorying tools in field storage.

  • PDF

Analysing the Use of Test Tools in Science-Related Affective Domain and its Improvements (과학 관련 정의적 영역 검사 도구 활용 및 개선 내용 분석)

  • Chung, Sue-Im;Shin, Donghee
    • Journal of The Korean Association For Science Education
    • /
    • v.39 no.2
    • /
    • pp.263-277
    • /
    • 2019
  • This study analyzed the current use of science-related test tools in affective area in Korean academic journals for the last 30 years since 1989 and the cases of modification of the original tools related to the tools. This provides practical information on the development and improvement of test tools in the future and offers the basis for developing valid test tools. The study was conducted in two stages. We analyzed the status of 88 domestic science education researches dealing with testing tools related affective characteristics and 57 domestic and foreign resource tools referenced by them. After that, we compared the characteristics of the five cases in which the original tool was revised and the concrete item correction examples. The results were analyzed as follows: topics that have emerged continuously or that have recently begun to appear in domestic research, the research situations according to their purpose and measurement methods used by the tool, and use state of original tools. The background and key points of revision were analyzed for the five tools, TOSRA, SAI, PISA items, STEBI-A/B, SMQ, whose revision process were disclosed. In addition, the changes of the items were analyzed by comparing the four test items with the questions before and after the revision. As a result of item analysis, item improvement was proceeding in the direction of enhancing readability, clarifying meaning, and changing items according to change of sub constructs. The implications of this study are as follows: notes on interpreting the results obtained from the tool with multiple mixed constructs, the possibility of the testing tool that broadens the horizon of the research, error recognition in the subjective self-report, and notes when applying test tools from other disciplines to science.

A Study on Measurement of Dynamic Accuracy Using Grid Encoder in NC Machine Tools (Grid Encoder를 이용한 NC공작기계 동적정밀도 측정에 관한 연구)

  • 이찬호;이방희;김성청
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.378-381
    • /
    • 2003
  • Efficient development of method on a performance evaluation for machine tools has been regarded as the most important work for accuracy and quality enhancement to every user and manufacturer. A evaluation method of accuracy for machine tools has been studied recently according to the rapid increase of interest in precision machine tools. To this point of view, the circular interpolation test of machine tools is recognized as the most useful method to distinguish a dynamic accuracy of NC machine tools by ISO and ANSI/ASME, etc. In this paper, we have studied and developed the form measurement system with grid encoder to analyse the final accuracy of NC machine tools. we have analyzed the servo system error and geometric error of NC machine tools through measuring a dynamic error signal by this system. and then we verified the experimental result and enhanced the reliability by means of comparing the characteristics of the developed system with the kinematic ball-bar system.

  • PDF

ADHESION STRENGTH OF DIAMOND COATED WC-Co TOOLS USING MICROWAVE PLASMA CVD

  • Kiyama, Nobumichi;Sakamoto, Yukihiro;Takaya, Matsufumi
    • Journal of Surface Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.540-544
    • /
    • 1996
  • To apply the CVD diamond film to coated tools, it is necessary to make adhesion strength between diamond film and substrate stronger. So adhesion strength of diamond coated WC-Co tools using Microwave Plasma CVD and cutting test of Al-18mass%Si alloy using diamond cutting tools were studied. Diamond coating was carried out using Microwave Plasma CVD apparatus. Reaction gas was used mixture of methane and hydrogen. Substrate temperature were varied from 673K to 1173K by control of microwave output power and reaction pressure. By observation of SEM, grain size became larger and larger as substrate temperature became higher and higher. Also all deposits were covered with clear diamond crystals. XRD results, the deposits were identified to cubic diamond. An analysis using Raman spectroscopy, the deposit synthesized at lower substrate temperature (673K) showed higher quality than deposit synthesized at higher substrate temperature (1173K). As a result of scratch adhesion strength test, from 873K to 1173K adhesion strength decreased by rising of substrate temperature. The deposit synthesized at 873K showed best adhesion strength. In the cutting test of Al-18mass%Si alloy using diamond coated tools and the surface machinability of Al-Si works turned with diamond coating tools which synthesized at 873K presented uniform roughness. Cutting performance of Al-18mass%Si alloys using diamond coated WC-Co tools related to the adhesion strength.

  • PDF

Survey of Clinical Assessment Inventory for Infant and Child Development (유아와 아동발달에 관한 임상평가도구 조사)

  • Hwang, Seong-Soo;Kwon, Hye-Jeoung
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.2
    • /
    • pp.1037-1045
    • /
    • 1996
  • The purposes of this survey are to investigate which inventory are used to assess the disables children, to give information and basic data for developing new inventory for disabled children. 1. 8 institutes (40 %) have no test or evaluate tools. 2. Number of tools of rehabilitation institutes have more than hospital. 3. 86.8% of tools are made in United States. 4. 52.2 % of tools do not test validity and reliability 5. 43.5% of tools are tested for gross and fine motor functions. 6. The interval of reassesstment are very irregulary(43.5 %). So, We suggest that Korean physical therapist should be made tools which is tested motor, perception and cognition with validity and relability for CNS dysfuntion patients.

  • PDF

The Development of Evaluation Tools for Young Children's Math Ability based on Content Standards of NCTM (NCTM의 수학교육 내용기준에 근거한 유아수학능력 평가도구 개발)

  • Kim, Ji-Young
    • Korean Journal of Human Ecology
    • /
    • v.17 no.1
    • /
    • pp.35-43
    • /
    • 2008
  • The purpose of this study is to develop evaluation tools for young children's mathematical ability based on the content standards of NCTM and to verify the suitability of the tools. The tools consist of 5 sub-tests with 90 items, including number and operation, algebra, geometry, measurement, data analysis and probability. The tool analysis was examined with 300 three-to five-years-old children and 31 math education professionals. The results of this research are as follows : First, in order of age the passing rate increased. The gap between high and low score group reveals a statistically meaningful difference. Second, the internal consistency reliability coefficient, Cronbach ${\alpha}$, is .96. Test-retest reliability is around .90. The concurrent validity correlation between this tools and Choi Hye-Jin's test(2003) is .85. The analysis of the content validity was proved appropriately by math education professionals.

Identification of motion error sources in NC machine tools by a circular interpolation test (원호보간시험에 의한 수치제어 공작기계의 운동오차원인 진단에 관한 연구)

  • Hong, Seong-Wook;Shin, Young-Jae;Lee, Hu-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.2
    • /
    • pp.126-137
    • /
    • 1993
  • This paper presents an efficient method for the identification of motion error sources in NC machine tools by making use of the circular interpolation test, which is often used in estimating the motion accuracy of NC machine tools. Mathematical formulae are described for motion errors due to various kinds of error sources. Two identification formulae are proposed: one is based on the frequency analysis and the other is formulated with the weithted residual method. Motion error signal is classified into two patterns, mean errors(mean of CW and CCW test signals from mean errors). The sources of the mean errors are identified by using the frequency analysis technique and the sources of the deviation errors by the weighted residual formulaltion. A menu driven, user oriented, computer program is written to realize the full steps of the proposed identificationprocedure. Then, the identification method is applied to two NC machine tools.

  • PDF