• Title/Summary/Keyword: Test Stream

Search Result 527, Processing Time 0.025 seconds

A Study on the Fire Extinguishing Ability Rating of Load Streams (강화액 소화성능평가에 관한 연구)

  • Kwon, Seong-Pil;Kim, Hyeong-Gweon;Yoon, Hun-Ju;SaKong, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.159-162
    • /
    • 2008
  • A standard fire extinguishing tester, with which we could conduct the fire extinguishing ability rating of a water-based fire extinguishing agent such as water and loaded stream, has been developed in this work. It could help us enhancing the efficiency and reliability of the fire extinguishing test of loaded streams, and at last increasing the productivity of fire protection related firms. Furthermore, our country could take the lead in making a new standard for the fire extinguishing test of loaded streams. As a result, it is expected that loaded streams could be improved by using it. In addition the standard fire extinguishing tester could be made moderately in our industry, and supplied at home and worldwide.

  • PDF

(An) analysis of quantum cryptography vulnerability by Binary merge (이진 병합에 의한 양자암호 취약성)

  • Rim, Kwang-Cheol;Choi, Jin-Suk
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.6
    • /
    • pp.837-842
    • /
    • 2010
  • In this paper, quantum cryptography systems used in the design process inevitably open bit stream of pseudo-random number that exists multiple open channels between them and the need to share information on the part of the situation exposes a pair of bit stream. In this paper, the base test of pseudo-random number I tested out this process and the merge bit binary column look out for randomness.

Automatic Control on Dosing Coagulant as to Stream Current

  • Oh, Sueg-Young;Byun, Doo-Gyoon;Hwang, Jae-Moon;Song, Hyun-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1318-1321
    • /
    • 2005
  • As recently raw water quality has been polluted as well as its quality has been remarkably varied according to season and region, the precise control of coagulant dosage is being keenly required in water treatment plants. The amount of coagulant is closely related to raw water quality such as turbidity, alkalinity, water temperature, pH, electrical conductivity, etc. Since the optimum quantity of chemicals is not yet finalized, so dosage rate must be decided by using jar test that takes one or two hours. Hereupon, the output signal of stream current and multi-regression on historical data were proposed to be applied to the coagulant dosing control. In consequence of applying the scheme to automatic determination of the dosage rate, it was testified that the determination of dosage rate was very effective in case it is performed as to real-time sensing of water quality and the output signal of stream current.

  • PDF

Characteristics of Probability Distribution of BOD Concentration in Anseong Stream Watershed (안성천 유역의 BOD농도 확률분포 특성)

  • Kim, Kyung Sub;Ahn, Taejin
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.3
    • /
    • pp.425-431
    • /
    • 2009
  • It is very important to know the probability distribution of water-quality constituents for water-quality control and management of rivers and reservoirs effectively. The probability distribution of BOD in Anseong Stream was analyzed in this paper using Kolmogorov-Smirnov test which is widely used goodness-of-fit method. It was known that the distribution of BOD in Anseong Stream is closer to Log-normal, Gamma and Weibull distributions than Normal distribution. Normal distribution can be partially applied depending on significance level, but Log-normal, Gamma and Weibull distributions can be used in any significance level. Also the estimated Log-normal distribution of BOD at Jinwi3 station was to be compared with the measured in 2001, 2002 and 2003 years. It was revealed that the estimated probability distribution of BOD at Jinwi3 follows a theoretical distribution very well. The applicable probability distribution of BOD can be used to explain more rigorously and scientifically the achievement or violation of target concentration in TMDL(Total Maximum Daily Load).

Development of Loaded Stream Fire Extinguishing Systems for Underground Transmission Cables (지중송전선로 접속부용 미분무 강화액 소화설비의 개발연구)

  • Lee, Sung-Mo
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.93-98
    • /
    • 2008
  • Full-scale fire extinguishment tests were conducted to develop loaded stream fire extinguishing systems for protecting underground transmission cables. The dimension of test mock-up was 5.5m height${\times}3m$ width ${\times}6m$ length, and six 154kV OF cables were piled up. Gasoline was used to ignite cates. Linear heat detection cables were installed on top of 154 kV OF cable and discharge nozzles were installed on the top and sidewalls, respectively. As a result, both surface fires and deap-seated fires were extinguished successfully within the specified 3 minutes by discharging loaded stream agent.

Experimental Study on Interaction Effect of Darrieus Tidal Stream Turbines (다리우스 조류 터빈의 상호작용 효과에 대한 실험적 연구)

  • Kim, Jihoon;Park, Jin-Soon;Ko, Jin Hwan
    • Ocean and Polar Research
    • /
    • v.41 no.3
    • /
    • pp.193-202
    • /
    • 2019
  • There have been various approaches for efficiency improvement of a Darrieus tidal stream turbine after it was introduced as an alternative of horizontal axis turbines. Among the approaches, the researches on the interaction effect of dual configuration were conducted. In this study, a dual Darrieus turbine with a coupling mechanism was proposed for investigating the interaction effect. Also, the effect of bi-directional tidal stream was analyzed with prototype fabrication, apparatus set-up and experiment conduction in indoor and offshore facilities. As the results of the experiments, the dual turbine in case of counter-rotation and inflow between the turbines improved efficiencies by 9.5% and 11.31%, respectively, as compared to the single turbine. Also, the dual turbine in case of the inflow improved efficiencies by 9.4% and 16.62%, respectively, as compared to that in case of outflow between the turbines which represented the case of 180 degrees change of flow direction after slack water. Therefore, the proposed dual turbine showed the advantage in terms of the efficiency as compared to the single turbine and the effect level of the slack water on the performance of the dual turbine was investigated.

A Comparative Study on the Preference and Visual Characteristics of Stream Landscape According to Hydromorpological Structures (하천의 물리적 구조에 따른 하천경관의 선호도 및 시각적 이미지 비교 연구)

  • Choi, Yun Eui;Lee, Jung A;Chon, Jinhyung
    • Journal of Wetlands Research
    • /
    • v.15 no.3
    • /
    • pp.301-315
    • /
    • 2013
  • The purpose of this study is to investigate characteristics of hydromorpological structures that affect landscape preference and visual characteristics on the sections of the designated streams where have dynamic ecological characteristics. We evaluated the ecological status of the streams utilizing LAWA to assess hydromorpological structures of streams. We also investigated preference and visual characteristics of stream landscapes through Semantic Differential Scale(SD scale). The differences of visual images according to the characteristics of hydromorpological structures in the sites were analyzed by descriptive statistics, One-way ANOVA, and t-test. As a result, this study showed that sections represented as "good" ecological status are shown to be harmonious, beautiful, natural, and clean comparing to sections represented as "poor" ecological status. The hydromorpological structures that have significant impacts on the visual characteristics are considered as riparian vegetation, cross-sectional shape, and the artificial structures. Results of this study can help guide the stream restoration of the damaged stream to improving ecological function and positive landscape.

Teacher-Student Architecture Based CNN for Action Recognition (동작 인식을 위한 교사-학생 구조 기반 CNN)

  • Zhao, Yulan;Lee, Hyo Jong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.3
    • /
    • pp.99-104
    • /
    • 2022
  • Convolutional neural network (CNN) generally uses two-stream architecture RGB and optical flow stream for its action recognition function. RGB frames stream display appearance and optical flow stream interprets its action. However, the standard method of using optical flow is costly in its computational time and latency associated with increased action recognition. The purpose of the study was to evaluate a novel way to create a two sub-networks in neural networks. The optical flow sub-network was assigned as a teacher and the RGB frames as a student. In the training stage, the optical flow sub-network extracts features through the teacher sub-network and transmits the information to student sub-network for baseline training. In the test stage, only student sub-network was operational with decreased in latency without computing optical flow. Experimental results shows that our network fed only by RGB stream gets a competitive accuracy of 54.5% on HMDB51, which is 1.5 times better than that on R3D-18.

A Study on the Test Strategy of Digital Circuit Board in the Production Line Based on Parallel Signature Analysis Technique (PSA 기법에 근거한 생산라인상의 디지털 회로 보오드 검사전략에 대한 연구)

  • Ko Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.11
    • /
    • pp.768-775
    • /
    • 2004
  • The SSA technique in the digital circuit test is required to be repeated the input pattern stream to n bits output nodes n times in case of using a multiplexor. Because the method adopting a parallel/serial bit convertor to remove this inefficiency has disadvantage of requiring the test time n times for a pattern, the test strategy is required, which can enhance the test productivity by reducing the test time based on simplified fault detection mechanism. Accordingly, this paper proposes a test strategy which enhances the test productivity and efficiency by appling PAS (Parallel Signature Analysis) technique to those after analyzing the structure and characteristics of the digital devices including TTL and CMOS family ICs as well as ROM and RAM. The PSA technique identifies the faults by comparing the reminder from good device with reminder from the tested device. At this time, the reminder is obtained by enforcing the data stream obtained from output pins of the tested device on the LFSR(Linear Feedback Shift Resister) representing the characteristic equation. Also, the method to obtain the optimal signature analyzer is explained by furnishing the short bit input streams to the long bit input streams to the LFSR having 8, 12, 16, 20bit input/output pins and by analyzing the occurring probability of error which is impossible to detect. Finally, the effectiveness of the proposed test strategy is verified by simulating the stuck at 1 errors or stuck at 0 errors for several devices on typical 8051 digital board.

A clinical effect of desensitizing agents applied on the root surface after periodontal treatment (치주 치료 후 적용된 상아질 지각과민 억제제의 임상 효과에 대한 연구)

  • Park, Sung-Il;Chung, Chin-Hyung;Lim, Sung-Bin;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.991-1002
    • /
    • 2005
  • The purpose of this study was to compare the effect of desensitizing agents applied on hypersensitive root surface following periodontal treatment. This study included 21 subjects(168 vital teeth). To evaluate dentin sensitivity, three clinical tests(tactile, air stream, cold water) were tried and three different densensitizing agents(MS coat, Elmex gel. Superseal) were individually applied. After application, reassessment was done at 1 minute, 1 week, 1 month and 3 months. The results were as follows : 1. The degree of dentin sensitivity was measured highly in the sequence of cold water, air stream and tactile and significantly decreased in all four groups with lapse of time(p<0.05). 2. There was no significant difference between all four groups in the tactile test with lapse of time. 3. There was no significant difference between three experimental groups in the air stream test with lapse of time. however, one minute later, it was measured highly in the sequence of Superseal, MS coat and Elmex 4. There was no significant difference between three experimental groups in the cold water test with lapse of time. As a result of this study, all of three agents were significantly effective in reducing dentin hypersensitivity and these agents could be positively employed to patients complaining of dentin hypersensitivity following periodontal treatment.