• Title/Summary/Keyword: Test Standards

Search Result 2,241, Processing Time 0.036 seconds

Development of a Standard to Assess Classifying Inquiry Skills by Observation (관찰에 의한 분류하기 탐구 능력 평가 준거 개발)

  • Ju, Jung-Eun;Cha, Hee-Young
    • Journal of Korean Elementary Science Education
    • /
    • v.26 no.4
    • /
    • pp.407-417
    • /
    • 2007
  • The purpose of this research is to develop standards with which we can design an instrument to assess classifying inquiry skills by observing students' behavior and reported outcome which is not the paper and pencil test. This research is focused on developing a standard for analysis of classifying ability among research functions. To identify classifying inquiry skills, standards from classifying behaviors were comparing ways with other cards and using information included in the cards; Standards selected from the final reports were the appropriateness, inconsistency and hierarchy of the classification outcome. The standards were initially selected during the class with picture cards printed various birds appearances on the front side and their traits on the back which was specially designed among sixth graders. The picture cards prepared with plant leaves and stems had designed to identify whether standards was effective to assess student's classifying ability. The standards was an effective tool to assess student's classifying inquiry skills.

  • PDF

Establishment of 20 kA AC High Current National Standard System (20 kA 교류 대전류 국가표준 시스템 구축)

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jeon-Hong;Kwon, Sung-Won;Song, Yang-Sup;Kim, Myung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1412-1413
    • /
    • 2007
  • 20 kA AC high current national standard system has been established with a purpose for support of heavy electrical industry. The system consists of high AC current source, the standard current transformer, current transformer comparator and current transformer burden, and current transformer under test.

  • PDF

Establishment of 200 kV AC High Voltage National Standard System (200 kV 교류 고전압 국가표준 시스템 구축)

  • Jung, Jae-Kap;Kwon, Sung-Won;Lee, Sang-Hwa;Kang, Jeon-Hong;Song, Yang-Sup;Kim, Myung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1414-1415
    • /
    • 2007
  • 200 kV AC high voltage national standard system has been established with a purpose for support of heavy electrical industry. The system consists of high AC voltage source and regulating unit, the standard voltage transformer, voltage transformer comparator, and voltage transformer burden, and voltage transformer under test.

  • PDF

A Study on the Mock up Test for Reduction of HCHO Using the Functional Gypsum Board (기능성 석고보드의 폼알데히드(HCHO) 저감성능 평가를 위한 실물시험(Mock up test)연구)

  • Kim, Hea-Jeong;Song, Kyoo-Dong;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.814-819
    • /
    • 2008
  • The purpose of this study was developing the building materials for creation the comfortable IAQ. By reducing formaldehyde(HCHO) known as the main factors of Sick House Syndrome. This material must be revealed the physical and eco-friendly performance, so this study set up the basic standards for building materials. The source of physical performance evaluation is Korea Industrial Standards and the base of environmental ability is the Eco Label considering certificated system related to an apartment house. Because the developed material was satisfied with the established standards, it was tested in mock-up room for obtaining the real date from indoor air. The mock-up test was conducted according environmental standard method for indoor air Quality of the ministry of environment. The result of this study were as follows; the functional building materials had a effect to reduce the formaldehyde concentration for a initial period without wall paper, so additional development is needed for application with the wall paper and the available period.

The Effect of Test Variables on the Accuracy of Equo-Tip Hardness (Equo-Tip 경도값에 미치는 실험변수의 영향)

  • Nahm, S.H.;Jeon, S.B.;Kim, J.J.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.3 no.2
    • /
    • pp.32-36
    • /
    • 1990
  • For the accurate measurements of hardness in a material, it is necessary to have a thorough understanding of the effects of test variables on the accuracy of hardness value. For the rebound hardness test, major test variables are the radius of hammer ball tip, type of backing materials, size and roughness of the specimen. In this study, effects of these variables on Equo-Tip hardness value were investigated. Hardness measurements were carried out using WC balls with various sizes of worn-ot zone. The sample materials chosen for the experiments were commercial standard hardness blocks and SM45C steel bars subjected to either normalization or quench and temper treatments. As backing materials, aluminum, steel and rubber plates were used in all the experiments. Experimental results show that for the accurate measurements of Equo-tip hardness, it is necessary to use the hammer ball with a worn-out zone parameter of less than 0.23, and the recommended minimum thickness and width of the specimen are 25mm and 70mm, respectively. Further for the surface preparation, the specimens need to be polished with an emery paper of No. 400 or finer, and for the backing matrials, it is recommended to use steels or rubbers.

  • PDF

Construction of Large 3-axis Square Helmholtz Coil system for the Power Frequendy Magnetic Field Immunity Test (전원주파수 교류자기장 내성평가용 대형 3-축 사각 헬름홀쯔 코일 시스템 제작)

  • 유권상;김창석;정낙삼
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.905-909
    • /
    • 1995
  • We constructed the large 3-axis square Helmholtz coil system for the power frequency magnetic field immunity test. We measured the coil factors and magnetic field homogeneities of the fabricated 3-axis square Helmholtz coil. The experimental results for the field homogeneities are in agreement with the theoretical data. From these results, we determined the effective areas for the immunity test. We also confirmed that the low current using the multi-turns coil can be applicable to the immunity test for the high field in short duration.

  • PDF

A Study on Reliability Test Conditions (신뢰성 시험조건에 관한 연구)

  • 전영록;김종걸;이낙영;권영일;홍연웅;나명환
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.227-229
    • /
    • 2001
  • The components of dependability are reliability, availability, maintainability, safety. The dependability thus often designated in terms of RAMS. A guide to the appropriate selection applicable standards on test conditions and statistical analysis is suggested. It includes a general guide to planning, performing and analysing data from reliability tests. The environmental and operational conditions available as IEC standards are referred.

  • PDF

An interior noise analysis of KTX vehicles on various operating conditions (한국형 고속철도 차량의 운행조건에 따른 차내 소음 분석)

  • Choi Sunghoon;Kim Jae-Chul;Lee Chan-Woo;Moon Kyung-Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.138-142
    • /
    • 2003
  • The conditions for measurement of the interior noise should meet the international standards. However, due to the limitations in test conditions the possible errors in measurement equipment, reliability of the measurement results has been questioned. Hence, the test procedure for the interior noise measurement of KTX vehicles are reviewed and investigated with the reference of international standards. Furthermore, the acceptable tolerance is inspected through the analysis of the factors that influence the interior noise of the KTX vehicle.

  • PDF

Comparisons of Certification Standards for Mask and Review on Filtration Efficiency for Viruses (마스크의 인증기준 비교와 바이러스 여과효율에 대한 고찰)

  • Yoon, Chungsik;Go, Sulbee;Park, Jihoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.109-123
    • /
    • 2020
  • Objectives: The aims of this study were to review the standards and key components of the standards for disposable masks in Korea, the US, EU, Japan, and China and to evaluate the appropriateness of disposable masks during a virus pandemic. Methods: We reviewed the standards in the above countries and compared their key elements for each standard. For the second purpose, systemic paper gathering using key words like 'mask', 'respirator' 'virus', and 'coronavirus' in the PubMed search engine was performed. Fifty-three papers were selected and reviewed in regard to the appropriateness of test protocols with sodium chloride(NaCl) particles for virus filtration and the effectiveness against viruses. Results: The standards for masks are largely divided into two categories: US standards and EU standards. In Korea, the Ministry of Employment and Labor adapted the EU standards for workers and the Health Masks adopted the Ministry of Employment and Labor standards by the Ministry of Food and Drug Safety. Regarding airborne viral infections, WHO emphasizes only droplet infection, while many studies have shown that small particles enter the air through coughing or sneezing, which increases the possibility of airborne infection. Compared to other particles, various factors such as airborne viability and the ability to replicate the virus in the body are further involved in the virus's airborne infection rate. Airborne infection is classified into absolute air infection, preferential air infection, and opportunistic air infection. The NaCl-certified N95 mask showed good filtration efficiency against viruses and NaCl particles were proved to be a surrogate material for viruses. From this, KF94 is also expected to be effective in blocking viruses. Conclusion: The N95 test method could be used as a surrogate test method for virus filtration. N95-class masks have been found to effectively block viral infections in the air. However, surgical or medical masks are only partially effective against airborne virus infection though they could effectively block large droplet infection. However, most studies considered in this study targeted N95 in foreign countries and studies on masks actually used in Korea are very limited, so studies on microorganisms and reuse on domestic masks should be conducted in the future.

Safety Requirements and Test Methods of a Radiofrequency Stimulator

  • Park, Sang-Geon
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.3
    • /
    • pp.191-199
    • /
    • 2016
  • In this study, we investigate the safety requirements and test methods of a radiofrequency stimulator. The main test items include controls of a minimum output, accommodation range, and output parameters that have been known as the safety requirements in conformity with international standards. As the test criteria for controlling the minimum output, an increase or decrease in a unit of 1 mA or 1 V or less was applied to the output amplitude regulator for both continuous and discontinuous control, and the output at the minimum setting was manipulated to not exceed 2% of the maximum setting. For controlling the output parameters, one of the representative test criteria states that the current limit of 250 mA should be equal to or less than 1,500 Hz. Consequently, when applying the radiofrequency stimulator on the human body, we need to ensure that the safety requirements conform to the international standards.