• Title/Summary/Keyword: Test Standards

Search Result 2,241, Processing Time 0.033 seconds

Roadmap Toward Certificate Program for Trustworthy Artificial Intelligence

  • Han, Min-gyu;Kang, Dae-Ki
    • International journal of advanced smart convergence
    • /
    • v.10 no.3
    • /
    • pp.59-65
    • /
    • 2021
  • In this paper, we propose the AI certification standardization activities for systematic research and planning for the standardization of trustworthy artificial intelligence (AI). The activities will be in two-fold. In the stage 1, we investigate the scope and possibility of standardization through AI reliability technology research targeting international standards organizations. And we establish the AI reliability technology standard and AI reliability verification for the feasibility of the AI reliability technology/certification standards. In the stage 2, based on the standard technical specifications established in the previous stage, we establish AI reliability certification program for verification of products, systems and services. Along with the establishment of the AI reliability certification system, a global InterOp (Interoperability test) event, an AI reliability certification international standard meetings and seminars are to be held for the spread of AI reliability certification. Finally, TAIPP (Trustworthy AI Partnership Project) will be established through the participation of relevant standards organizations and industries to overall maintain and develop standards and certification programs to ensure the governance of AI reliability certification standards.

Domestic Technical Standards and Performance Test of Photovoltaic PCS for Renewable Energy (신재생에너지용 태양광 PCS 국내 기술기준 및 성능시험)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.479-484
    • /
    • 2018
  • This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)-Characteristics of the utility interface. This standard tests utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1)voltage, current and frequency, 2)normal voltage operating range, 3)DC injection, 4)normal frequency operating range, 5)harmonics and 6)waveform distortion, 7)power factor of PV inverter. Therefore in this paper each test item of domestic technical standard is studied and analyzed and finally full tested by PV inverter performance function.

Installation of Test Equipment for Lightning Surge Complying with International Standard (국제시험규격에 적합한 뇌서지 시험설비 구축)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.360-364
    • /
    • 2006
  • Recently KS documents related to lightning protection were revised complying with the requirements of IEC standards. Lightning protection parts are divided three in IEC, those are arrestor(60099), SPD(61643), and protection facilities(62305). According as international standard is applicable in Korea, type tests, routine tests, and acceptance tests shall be made to demonstrate compliance with the relevant standards. KESRI have installed test equipment which is funded by Ministry of Commerce, Industry and Energy fit for lightning surge test form 2002, and we introduce the test equipments in detail.

  • PDF

Drop Simulation of Puppy Robot by Toys Safety Standards (완구 안전검사 기준을 적용한 강아지 로봇의 낙하 해석)

  • Chung Tae-Eun;Kim Jun-Gi;Sin Hyo-Chol
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.710-713
    • /
    • 2005
  • Many impact or drop test researches of home appliances are published, but those of toys cannot be found easily. External impacts are the primary causes of fracture of toys. For impact proof design, the finished product should pass an impact test after molding design. There are several international toy safety standards or requirements such as US CPSC(Consumer Product Safety Commission), ASTM F963-96a, EN71 and so on. The puppy robot which patrols around the house, namely, the watchdog was selected to investigate toy safety because it has considerable weight and outer panels are made of plastics. First the model of watchdog robot was obtained by 3 dimensional scan. Surface data can be generated from 3D polygon data of the watchdog. A reliable drop simulation method for the watchdog was established using Pam-crash program according to Korean toy safety standards. When there is a low impact allowance value, the molding design should be reinforced or changed. It was found that the maximum impact stress reaches the ultimate stress of panel material.

  • PDF

Measuring of Loss factor and Young's modulus of Plastics with Temperature Variation (온도변화에 따른 플라스틱의 손실계수와 Young 률의 측정)

  • Shin Su Hyun;Jung Sung Soo;Lee Yong Bong;Lee Doo Hee
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.321-322
    • /
    • 2004
  • It is well known that the loss factor and Young's modulus are fundamental mechanical properties of materials. In this study. the dynamic characteristics of plastics are evaluated by using two different standard test methods which are ASTM E 756 and ISO 6721. Polycarbonate and acrylonitrile butadiene styrene were used as test specimens. In order to evaluate vibration of damping properties with temperature, we measured loss factor and Young's modulus of the specimens the temperature range between $-10^{\circ}C$ and $60^{\circ}C$. The Young's modulus for polycarbonate decreased significantly as increasing temperature, while the loss factor increased. However, the Young's modulus and loss factor of acrylonitrile butadiene styrene are varied somewhat with temperature.

  • PDF

The Air Leakage Characteristics and Airtightness Performance of a Newly Built Apartment (신축 공동주택의 누기특성 및 기밀성능 분석에 관한 연구)

  • Lee, Yun Gyu;Shin, Cheol Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.11
    • /
    • pp.606-611
    • /
    • 2013
  • In responding to the recent framework convention on climate change, and the rise of the need for energy efficient buildings, such as Zero Energy Buildings (ZEB), domestic insulation standards and energy conservation regulations are being reinforced, to prevent heat loss. Accordingly, the Ministry of Land, Infrastructure and Transport have made amendments in Chapter 21 "Enforcement regulations for building facilities standards etc.", and Chapter 22 "Energy conservation standard", to reflect these changes. To effectively implement these regulations, it is required to propose air-tightness test methods, and establish air-tightness standards, based on the air leakage characteristics of domestic apartment housings. This research has been done primarily to collect basic technical data, to provide guidance for the establishment of domestic air-tightness standards for new apartment housing, through studying air-tightness test methods, field measurement on air-tightness of new apartment housings, and air leakage characteristics of major developed countries.

A Review of Current Status and Applications of Korean Industrial Standards (KS) on the Floor Slip Resistance Testing (바닥의 미끄럼 시험에 관한 한국산업표준(KS) 현황 및 적용 실태)

  • Baik, Kwon-Hyuk;Ji, Suk-Won;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.19-20
    • /
    • 2021
  • Although various laws and regulations have been put in place to prevent slips and falls, many accidents still occur. In this study, the root cause of slips and falls not decreasing were investigated. There are five types of slip resistance test methods in the Korean Industrial Standards (KS). Namely, KS F 2375:2016, KS F 2601:2020, KS F 2602:2016, KS L 1001:2020, and KS G 5821-1:2020 are listed. These test methods are cited in building certification standards (BF and G-SEED), construction specifications, and other documents that specify slip safety criteria. As a result of the investigation, a number of errors in KS regulations and legal text, errors in the manufacture and operation of slip testers, and errors in the use of measured values were found. These errors threaten the public life safety and disrupt industrial sites, and must be corrected immediately.

  • PDF

The Analysis of KASS Operational Mitigation Methods and Continuity Cases Based on ICAO Standards (ICAO 표준 기반 KASS 운영 상 완화조치 및 연속성 사례 분석)

  • Yun-Jung Choi;Dong-Hwan Bae;Hyo-Jung Yoon;Donghwan Yoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.13 no.2
    • /
    • pp.131-136
    • /
    • 2024
  • This paper deal with a method for calculating the continuity of Korea Augmentation Satellite System (KASS), which was completed in Korea in December 2023, and a plan to respond in the event that a continuity hazard situation occurs during operation. For this purpose, the International Civil Aviation Organization (ICAO) Satellite Based Augmentation System (SBAS) continuity standards, Wide Area Augmentation System (WAAS), and European Geostationary Navigation Overlay Service (EGNOS) continuity cases are examined in this paper. According to the measures recommended by the ICAO, when the number of continuity risks exceeds a certain level and the level drops drastically, various mitigation operations by country are implemented. Through this, if KASS does not meet ICAO continuity standards in the future, such measures can be referred to. In addition, this paper computes the short-term KASS continuity during the test broadcast period. Although continuity does not meet the ICAO standards, although this test period is too short, further meaningful analysis in the future is required. Additionally, this paper carried out an analysis of the timing and period to systematically calculate the meaningful value of continuity.

Corrosion Performance of Cu Bonded Grounding-Electrode by Accelerated Corrosion Test

  • Choi, Sun Kyu;Kim, Kyung Chul
    • Corrosion Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.211-217
    • /
    • 2018
  • Natural degradation of grounding-electrode in soil environment should be monitored for several decades to predict the lifetime of the grounding electrode for efficient application and management. However, long-term studies for such electrodes have many practical limitations. The conventional accelerated corrosion test is unsuitable for such studies because simulated soil corrosion process cannot represent the actual soil environment. A preliminary experiment of accelerated corrosion test was conducted using existing test standards. The accelerated corrosion test that reflects the actual soil environment has been developed to evaluate corrosion performances of grounding-electrodes in a short period. Several test conditions with different chamber temperatures and salt spray were used to imitate actual field conditions based on ASTM B162, ASTM B117, and ISO 14993 standards. Accelerated degradation specimens of copper-bonded electrodes were made by the facile method and their corrosion performances were investigated. Their corrosion rates were calculated to $0.042{\mu}m/day$, $0.316{\mu}m/day$, and $0.11{\mu}m/day$, respectively. These results indicate that accelerated deterioration of grounding materials can be determined in a short period by using cyclic test condition with salt spray temperature of $50^{\circ}C$.

The Performance Improvement of Lightning Arrester Leakage Current Measuring Device for GIS (GIS용 피뢰기 누설전류 측정장치 성능개선)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1726-1731
    • /
    • 2014
  • This paper shows the developed new lightning arrester LCM (Leakage Current Measuring device) which is important element of GIS (Gas Insulated Switchgear) Preventive & Diagnostic system and verify its performance though strengthened test standards. The existing lightning arrester LCM was modified to solve measuring errors which happened frequently. At first, we explained the principle of measuring leakage current. Through analyzing some problems which the existing LCM have. we got some improvable items. For the performance verification of the improved LCM, we manufactured prototype LCM which is applied some improvable items such as improving LCM circuit, adding protection circuit, optimizing inner structure of LCM and changing ground design. After then we carried out the performance test. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria. Also, we confirmed the performance of the improved LCM installed & being operated at G Substation through the immunity test against the normal noise and open/close surge etc.