• 제목/요약/키워드: Test Code

검색결과 2,167건 처리시간 0.025초

3차원 광학시뮬레이션을 사용한 PDP의 광학적 특성에 관한 연구 (A Study of Optical Property in PDP Using 3D Optical Code)

  • 강정원;박현명
    • 반도체디스플레이기술학회지
    • /
    • 제9권3호
    • /
    • pp.71-74
    • /
    • 2010
  • In this study the optical properties, such as relative transmittance and reflectance of PDP were analyzed with 3D optical code. Because of the electrode structure, the reference model shows 21.3 % higher transmittance than the test model and the reference model shows 16.6 % higher reflectance than the test model. The calculated reflectance of reference and test models is compared to the measured reflectance and the difference between calculation and measurement is 4.9 %.

Numerical simulation of complex hexagonal structures to predict drop behavior under submerged and fluid flow conditions

  • Yoon, K.H.;Lee, H.S.;Oh, S.H.;Choi, C.R.
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.31-44
    • /
    • 2019
  • This study simulated a control rod assembly (CRA), which is a part of reactor shutdown systems, in immersed and fluid flow conditions. The CRA was inserted into the reactor core within a predetermined time limit under normal and abnormal operating conditions, and the CRA (which consists of complex geometric shapes) drop behavior is numerically modeled for simulation. A full-scale prototype CRA drop test is established under room temperature and water-fluid conditions for verification and validation. This paper describes the details of the numerical modeling and analysis results of the several conditions. Results from the developed numerical simulation code are compared with the test results to verify the numerical model and developed computer code. The developed code is in very good agreement with the test results and this numerical analysis model and method may replace the experimental and CFD method to predict the drop behavior of CRA.

IP 설계 환경을 위한 VHDL Code Coverage Checker (VHDL Code Coverage Checker for IP Design and Verification)

  • 김영수;류광기;배영환;조한진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.325-328
    • /
    • 2001
  • This paper describes a VHDL code coverage checker for If design and verification. Applying the verification coverage to IP design is a methodology rapidly gaining popularity. This enables the designers to improve the IP design quality and reduces the time-to-market by providing the Quantitative measure of simulation completeness and test benches. To support this methodology, a VHDL code coverage model was defined and the measurement tool was developed.

  • PDF

우편용 4 State 바코드시스템의 판독오차 최소화 방법 (Minimization Method of Reading Error in Postal 4 State Bar Code Reader)

  • 황재각;신미영;박문성
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.1027-1030
    • /
    • 1999
  • Recently many efforts on the development of automatic processing system for delivery sequence sorting have been performed in ETRI, which requires the use of postal 4 state bar code system to encode delivery points. This paper addresses the issue on the reduction of reading error in postal 4 state raster beam based bar code reader by adjusting measured values of bar code width to its average value over each interval. The test results show that the above method reduces the average reading error rate approximately by 90-100%.

  • PDF

Three Dimensional Numerical Code for the Expanding Flat Universe

  • Min, Kyoung-W.
    • Journal of Astronomy and Space Sciences
    • /
    • 제4권2호
    • /
    • pp.101-106
    • /
    • 1987
  • The current distribution of galaxies may contain clues to the condition of the universe when the galaxies condensed and to nature of the subsequent expansion of the universe. The development of this large scale structure can be studied by employing N-body computer simulations. The present paper describes the code developed for this purpose. The computer code calculates the motion of collisionless matter acting under the force of gravity in an expanding flat universe. The test run of the code shows the error less than 0.5% in 100 iterations.

  • PDF

탄소섬유쉬트로 보강된 원형CFT기둥의 압축거동과 ACI 440 code를 응용한 압축내력예측식 제안 (Axial Loading Behaviors and ACI 440 Code Applied Ultimate Axial Strength Formula of CFRP Strengthened Circular CFT Columns)

  • 박재우;홍영균;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제2권1호
    • /
    • pp.23-29
    • /
    • 2011
  • 본 연구에서는 CFRP쉬트로 보강된 원형 CFT기둥의 압축거동을 관찰하고 설계식을 제안하였다. 원형 CFT기둥의 CFRP쉬트의 보강효과를 관찰하기 위해 10개의 실험체를 제작하여 중심축하중 실험을 수행하였다. 실험변수로는 CFRP쉬트 보강겹수와 직경-두께비(D/t)이다. 실험결과 원형CFT기둥에 CFRP쉬트 보강을 통해 압축내력을 증가시킨 것으로 나타났다. 끝으로 ACI 440code를 응용하여 CFRP 보강된 원형 CFT기둥의 압축내력을 예측하기 위한 설계식을 제안한다. 제안식을 분석한 결과 실험결과와 비교적 일치한 것으로 나타났다.

Development and Test of 2.5-Dimensional Electromagnetic PIC Simulation Code

  • Lee, Sang-Yun;Lee, Ensang;Kim, Khan-Hyuk;Seon, Jongho;Lee, Dong-Hun;Ryu, Kwang-Sun
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권1호
    • /
    • pp.45-50
    • /
    • 2015
  • We have developed a 2.5-dimensional electromagnetic particle simulation code using the particle-in-cell (PIC) method to investigate electromagnetic phenomena that occur in space plasmas. Our code is based on the leap-frog method and the centered difference method for integration and differentiation of the governing equations. We adopted the relativistic Buneman-Boris method to solve the Lorentz force equation and the Esirkepov method to calculate the current density while maintaining charge conservation. Using the developed code, we performed test simulations for electron two-stream instability and electron temperature anisotropy induced instability with the same initial parameters as used in previously reported studies. The test simulation results are almost identical with those of the previous papers.

Experimental investigation and validation of TASS/SMR-S code for single-phase and two-phase natural circulation tests with SMART-ITL facility

  • Bae, Hwang;Chun, Ji-Han;Yun, Eunkoo;Chung, Young-Jong;Lim, Sung-Won;Park, Hyun-Sik
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.554-564
    • /
    • 2022
  • The natural circulation phenomena occurring in fully integrated nuclear reactors are associated with a unique formation mechanism. The phenomenon results from a structural feature of these reactors involving upward flow from the core, located in the central-bottom region of a single vessel, and downward flow to the steam generator in the annulus region. In this study, to understand the natural circulation in a single vessel involving a multi-layered flow path, single-phase and two-phase natural circulation tests were performed using the SMART-ITL facility, and validation analysis of the TASS/SMR-S code was performed by comparing the corresponding test results. Three single-phase natural circulation tests were sequentially conducted at 15%, 10%, and 5% of full-scaled core-power without RCP operation, following which a two-phase natural circulation test was successively conducted with an artificial discharge of coolant inventory. The simulation capability of the TASS/SMR-S code with respect to the natural circulation phenomena was validated against the test results, and somewhat conservative but reasonably comparative results in terms of overall thermalhydraulic behavior were shown.

Wind Tunnel Test를 통한 Wind Moment의 적용 사례 (Application of Wind Heeling Moment with Wind Tunnel Test)

  • 김진호;이상열;박세일;김양수
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2015년도 특별논문집
    • /
    • pp.74-78
    • /
    • 2015
  • When floating platform or drilling unit is located at operating station during its design life, it has to have the sufficient stability considering external environment. To evaluate whether offshore structure is complied with the required design criteria for intact stability, the factors which decrease the righting moment have to be considered. Wind heeling moment is one of main factors because the direction is opposite to the righting moment. According to 2009 MODU CODE (Code for the construction and equipment of Mobile Offshore Drilling Units, 2009), wind heeling moment derived from wind tunnel test on scale model of offshore structure enables to apply as alternative given formula and method in 2009 MODU CODE. However, there is no the specific method for applying data derived from wind tunnel test. Based on the following reasons, this paper presents that the calculation method of wind heeling moment utilizing non-dimensional coefficient relative to wind loads (wind forces and moments) and the comparison with each method applying an example.

  • PDF

Automatic Container Code Recognition from Multiple Views

  • Yoon, Youngwoo;Ban, Kyu-Dae;Yoon, Hosub;Kim, Jaehong
    • ETRI Journal
    • /
    • 제38권4호
    • /
    • pp.767-775
    • /
    • 2016
  • Automatic container code recognition from a captured image is used for tracking and monitoring containers, but often fails when the code is not captured clearly. In this paper, we increase the accuracy of container code recognition using multiple views. A character-level integration method combines recognized codes from different single views to generate a new code. A decision-level integration selects the most probable results from the codes from single views and the new integrated code. The experiment confirmed that the proposed integration works successfully. The recognition from single views achieved an accuracy of around 70% for the test images collected on a working pier, whereas the proposed integration method showed an accuracy of 96%.