• Title/Summary/Keyword: Test Chamber

Search Result 1,531, Processing Time 0.03 seconds

Theoretical simulation on evolution of suspended sodium combustion aerosols characteristics in a closed chamber

  • Narayanam, Sujatha Pavan;Kumar, Amit;Pujala, Usha;Subramanian, V.;Srinivas, C.V.;Venkatesan, R.;Athmalingam, S.;Venkatraman, B.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2077-2083
    • /
    • 2022
  • In the unlikely event of core disruptive accident in sodium cooled fast reactors, the reactor containment building would be bottled up with sodium and fission product aerosols. The behavior of these aerosols is crucial to estimate the in-containment source term as a part of nuclear reactor safety analysis. In this work, the evolution of sodium aerosol characteristics (mass concentration and size) is simulated using HAARM-S code. The code is based on the method of moments to solve the integro-differential equation. The code is updated to FORTRAN-77 and run in Microsoft FORTRAN PowerStation 4.0 (on Desktop). The sodium aerosol characteristics simulated by HAARM-S code are compared with the measured values at Aerosol Test Facility. The maximum deviation between measured and simulated mass concentrations is 30% at initial period (up to 60 min) and around 50% in the later period. In addition, the influence of humidity on aerosol size growth for two different aerosol mass concentrations is studied. The measured and simulated growth factors of aerosol size (ratio of saturated size to initial size) are found to be matched at reasonable extent. Since sodium is highly reactive with atmospheric constituents, the aerosol growth factor depends on the hygroscopic growth, chemical transformation and density variations besides coagulation. Further, there is a scope for the improvement of the code to estimate the aerosol dynamics in confined environment.

Linear Regression Analysis to Evaluate the Particulate Matter Removal Rate of Functional Construction Materials (건설자재 미세먼지 제거율 평가를 위한 선형 회귀 분석법 제안)

  • Park, Kwang-Min;Min, Kyung-Sung;Jung, Sang-Hwa;Roh, Yonug-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.86-93
    • /
    • 2021
  • In order to remove particulate matter, functional construction materials are developed. However, there is no evaluation method and infrastructure for particulate matter removal rate. Therefore, the purpose of this study was to build a particulate matter removal rate test chamber and to present a method for particulate matter removal rate. As a result, since construction materials have effectiveness in an environment where particulate matter is generated, the particulate matter injection step was proposed as a comparison target. The evaluation of the particulate removal rate was proposed by relative comparison of the slope values obtained by linear regression analysis for all concentration values measured in the particulate matter injection step. In linear regression method, all measured values can be evaluated, and the variability can be evaluated with the coefficient of determination (R-square), so that the reliability of the particulate matter removal rate can be secured.

Effect of Cyclic Moisture Content Changes on Shrinkage and Thermal Conductivity in Domestic Quercus acutissima Carr. and Larix Kaempferi Carr. (국내산 상수리나무와 일본 잎갈나무의 수축율과 열전도율에 대한 주기적인 함수율 변화의 영향)

  • Mun, Sung-Hee;Cha, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.41-50
    • /
    • 2002
  • Small clear specimens of Quercus acutissima Carr. and Larix caempferi Carr. were used to measure shrinkage and thermal conductivity for the reasonable and effective use. All samples were conditioned to 18, 12, 5% moisture contents in a humidity chamber of 86, 66, 20% relative humidity(RH), respectively and room temperature(23℃) All specimens were conducted on the shrinkage and thermal conductivity test at each MCs. These processes(cycle) were repeated three times. The radial and tangential shrinkages of Quercus acutissima Carr. and Larix caempferi Carr. decreased at each level of MCs, with the increasing cycles. The radial and tangential shrinkages increased as the specific gravity(on oven-dry weight and volume basis) increased. Thermal conductivities of the radial and tangential direction of Quercus acutissima Carr. and Larix caempferi Carr. increased at each levels of MCs, with increasing cycles. Good correlations were obtained between shrinkages and thermal conductivities of radial and tangential direction, and specific gravity (on oven-dry weight and oven-dry volume basis) and MC.

A Study on the Flow Conditions of the Combustion Air Heater Outlet for the Supersonic Combustion Experiment (초음속 연소 실험을 위한 연소식 공기 가열기 출구 유동 조건 실험 연구)

  • Lee, Eun Sung;Han, Hyung-Seok;Lee, Jae Hyuk;Choi, Jeong-Yeol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.1
    • /
    • pp.88-97
    • /
    • 2022
  • In this study, a vitiated air heater was designed and manufactured to supply high-temperature and high-pressure air to the ground test apparatus of a direct-connected supersonic combustor, and an experiment was performed to verify the target design point. By installing wedges at the upper boundary, lower boundary and center of the nozzle exit of the vitiated air heater, it was confirmed that the Mach number satisfies the 2.0 level, and the pressure of the combustion chamber was also satisfactory compared to the design point. In the case of temperature, the measured temperature deviation was large due to the degree of exposure of the thermocouple and the slow response characteristics. After that, the isolator was connected to the rear of the vitiated air heater, and the Mach number was measured in the same method, and the Mach number at the center of the isolator eixt was slightly reduced to 1.8~1.9.

Hydrogen Jet Structure and Measurement of Local Equivalence Ratio by LIBs under the Different Injection Pressure (분사 압력에 따른 수소 제트의 형상과 LIBs를 적용한 국부 당량비 계측)

  • Lee, Sanguk;Kim, Jungho Justin;Bae, Choongsik
    • Journal of ILASS-Korea
    • /
    • v.27 no.2
    • /
    • pp.84-93
    • /
    • 2022
  • To implement carbon-neutrality in transportation sectors until 2050, hydrogen is considered a promising fuel for internal combustion engines because hydrogen does not contain carbon itself. Although hydrogen does not emit CO2 emission from its combustion process, the low energy density in a volume unit hinders the adoption of hydrogen. Therefore, the understanding of hydrogen jet behavior and measurement of equivalence ratio must be conducted to completely implement the high-pressure hydrogen direct injection. The main objective of this research is feasibility test of hydrogen local equivalence ratio measurement by laser-induced breakdown spectroscopy (LIBs). To visualize the macroscopic structure of hydrogen jet, high-speed schlieren imaging was conducted. Moreover, LIBs has been adopted to validate the feasibility of hydrogen local equivalence ratio measurement. The hydrogen injection pressure was varied from 4 MPa to 8 MPa and injected in a constant volume chamber where the ambient pressure was 0.5 MPa. The increased injection pressure extends the vertical penetration of hydrogen jet. Due to the higher momentum supply when the injection pressure is high, the hydrogen has easily diffused in all directions. As the laser trigger timing has delayed, the low hydrogen atomic emission was detected due to the longer mixture formation time. Based on equivalence ratio measurement results, LIBs could be applied as a methodology for hydrogen local equivalence ratio measurement.

A Study on the Response Characteristics of 200MW Gas Turbine Governor System (200MW급 가스터빈 조속기 응답특성에 대한 연구)

  • Han, Young-Bok;Nam, Kang-Hyun;Kim, Sung-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.625-632
    • /
    • 2022
  • Gas turbine generators in load-following operation in the domestic power system play a major role in maintaining the rated frequency, but often have poor frequency control. Therefore, after examining the control characteristics of the governor, which is a gas turbine speed control device, and analyzing the failure types, countermeasures were suggested for each case. In addition, it was confirmed through the governor response test that the gas turbine helps in frequency recovery depending on the speed of fuel control, but also acts as a factor impeding stable operation, such as rapid fluctuations in combustion chamber temperature and combustion vibration. Therefore, in order to maintain stable power quality, there was a need for thorough facility management as well as research on the governor control method in which the traditional PID control method and the machine learning algorithm, a core field of the 4th industry, were fused.

Characteristic Verification of Electronically Scanned Array Antenna for a Ku-band FMCW Radar (Ku-대역 FMCW 레이더용 전자식 빔 조향 배열 안테나 특성 검증)

  • Chae-Hyun Jung;Jaemin Lee;Minchul Kim;Hang-Soo Lee;Sungjun Yoo;Sunghoon Jang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.4
    • /
    • pp.65-71
    • /
    • 2023
  • In this paper, the design, fabrication and verification steps of an electronically scanned array antenna(AESA) for a photonics-based Ku-band FMCW radar system is described. The presented system consists of a transmitter and a receiver respectively, which has a same antenna in the transceiver. The designed antenna has 2×8 array configuration and operates at Ku-band. The VSWR(Voltage Standing Wave Ratio) of each 16-radiators and the coupling power between radiators is measured. Also, in order to minimize the radar system damage because of handover power from the transmitter antenna to the receiver antenna when the transmitter works, the isolation between the transmitter antenna and the receiver antenna is optimized by test. As a result, beamwidth, side lobe level and beam steering characteristic are obtained by synthesizing each radiator pattern measurement data after each beam pattern of 16-radiators is measured in the near-field chamber.

Study on the Thermal Conductivity of Frozen Soil Considering Various Experimental Conditions (다양한 실험조건을 고려한 동결 사질토의 열전도도 산정에 대한 연구)

  • Kim, Hee-Won;Go, Gyu-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.9
    • /
    • pp.5-11
    • /
    • 2023
  • In analyzing geotechnical structures, the analysis fields are becoming increasingly diversified. In particular, the need for predicting the thermal behavior of ground materials has become important in fields related to soil freezing. To ensure a reliable assessment of the freezing behavior of the ground, considering the variation in the effective thermal conductivity of soil specimens under various conditions is crucial. In this study, probe experiments were conducted by varying the porosity, initial degree of saturation, and read time settings of the meter. Next, the factors influencing the effective thermal conductivity of the frozen sandy soil were evaluated. The experimental results conducted under different porosity conditions showed a tendency for the effective thermal conductivity of frozen soil to increase as the specimen's porosity decreased. However, as the degree of saturation of the specimen increased, the effective thermal conductivity also increased. The sensitivity of the meter's read time setting to the measurement of effective thermal conductivity was observed. When the read time was set to 1 min, the measured values were in a range similar to that obtained in previous studies conducted in Korea with the same soil specimen.

Feasibility Test of Flat-Type Faraday Cup for Ultrahigh-Dose-Rate Transmission Proton Beam Therapy

  • Sang-il Pak;Sungkoo Cho;Seohyeon An;Seonghoon Jeong;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.108-113
    • /
    • 2022
  • Purpose: Proton therapy has been used for optimal cancer treatment by adapting its Bragg-peak characteristics. Recently, a tissue-sparing effect was introduced in ultrahigh-dose-rate (FLASH) radiation; the high-energy transmission proton beam is considered in proton FLASH therapy. In measuring high-energy/ultrahigh-dose-rate proton beam, Faraday Cup is considered as a dose-rate-independent measurement device, which has been widely studied. In this paper, the feasibility of the simply designed Faraday Cup (Poor Man's Faraday Cup, PMFC) for transmission proton FLASH therapy is investigated. Methods: In general, Faraday cups were used in the measurement of charged particles. The simply designed Faraday Cup and Advanced Markus ion chamber were used for high-energy proton beam measurement in this study. Results: The PMFC shows an acceptable performance, including accuracy in general dosimetric tests. The PMFC has a linear response to the dose and dose rate. The proton fluence was decreased with the increase of depth until the depth was near the proton beam range. Regarding secondary particles backscatter from PMFC, the effect was negligible. Conclusions: In this study, we performed an experiment to investigate the feasibility of PMFC for measuring high-energy proton beams. The PMFC can be used as a beam stopper and secondary monitoring system for transmission proton beam FLASH therapy.

Behavior of Model Pile Embedded in Expansive Soil with Magnesia Oxide-Based Refractories (MgO계 내화물이 함유된 팽창성 지반에서의 모형말뚝 거동 분석)

  • Yoon, Boyoung;Kim, Mintae
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.11
    • /
    • pp.33-40
    • /
    • 2023
  • This study explores the performance of pile foundations in highly expansive soil, incorporating magnesium oxide-based refractory materials. A controlled model chamber, housing a fixed pile, was utilized to induce ground expansion through fused magnesia (FM). The investigation focused on measuring the vertical displacement of FM-sand mixtures and the axial load on the pile in relation to depth and time. The study varied the amount of FM content (FMc) at 30%, 50%, and 70%. The upward movement exhibited an augmentation with increasing FMc, tapering off with depth as accumulation progressed toward the mixture surface. Compression and tensile forces were both evident along the pile for FMc at 30% and 50%, while only a tensile force was observed at an FMc of 70%. These results offer valuable insights for the analysis of pile behavior within FM-sand mixtures.