• Title/Summary/Keyword: Test Case Evaluation

Search Result 1,348, Processing Time 0.025 seconds

Study on the pronunciation correction in English Learning (영어 학습 시의 발성 교정 기술에 관한 연구)

  • Kim Jae-Min;Beack Seung-Kwon;Hahn Minsoo
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.119-122
    • /
    • 2000
  • In this paper, we implement an elementary system to correct accent, pronunciation, and intonation in English spoken by non-native English speakers. In case of the accent evaluation, energy and pitch information are used to find stressed syllables, and then we extract the segment information of input patterns using a dynamic time warping method to discriminate and evaluate accent position. For the pronunciation evaluation. we utilize the segment information using the same algorithm as in accent evaluation and calculate the spectral distance measure for each phoneme between input and reference. For the intonation evaluation. we propose nine pattern of slope to estimate pitch contour, then we grade test sentences by accumulated error obtained by the distance measure and estimated slope. Our result shows that 98 percent of accent and 71 percent of pronunciation evaluation agree with perceptual measure. As the result of the intonation evaluation. system represent the similar order of grade for the four sentences having different intonation patterns compared with perceptual evaluation.

  • PDF

Reliability Evaluation of Power Distribution Systems Considering the Momentary Interruptions-Application of Monte Carlo Method (순간정전을 고려한 배전계통에서의 신뢰도 평가-몬테카를로 방식의 적용)

  • Sang-Yun Yun;Jae-Chul Kim
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.1
    • /
    • pp.9-16
    • /
    • 2003
  • In this paper, we propose a reliability evaluation method considering the momentary interruptions of power distribution systems. The results of research are concentrated on two parts. One is the analytic and probabilistic reliability evaluation of power distribution system considering the momentary interruptions and the other is the reliability cost evaluation that unifies the cost of sustained and momentary interruptions. This proposed reliability cost evaluation methodology is also divided into the analytic and probabilistic approach and the time sequential Monte Carlo method is used for the probabilistic method. The proposed methods are tested using the modified RBTS (Roy Billinton Test System) form and historical reliability data of KEPCO (Korea Electric Power Corporation) system. Through the case studies, it is verified that the proposed reliability evaluation and its cost/worth assessment methodologies can be applied to the actual reliability studies.

Preference of the View from Apartment Units regarding View Points (조망 시점 위치에 따른 아파트 단위세대 조망 경관 선호 특성)

  • Moon, Ji-Won;Lee, Sang-Bok;Ha, Jae-Myung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.242-247
    • /
    • 2006
  • This study is intended to analyze the characteristics of the preference according to the locations of view points, which are the current criteria for the evaluation of the view. To this end, a total of fifty one test cases according to view point locations were sampled based on the picture data collected in previous studies, and preference assessment was conducted on these cases to identify preference characteristics, where a five-point Lickert-scale evaluation was performed for each test case, and three test cases for each type were comparatively evaluated. It is deemed that the findings from this study may be used to finally derive qualitative assesment scale for the view seen from apartment units.

  • PDF

Performance Evaluation Technique of the RTSP based Streaming Server (RTSP기반 스트리밍 서버의 성능 측정 기술)

  • Lee YongJu;Min OkGee;Kim HagYoung;Kim MyungJoon
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07a
    • /
    • pp.799-801
    • /
    • 2005
  • There have been many streaming servers that provide a large number of contents for a user's preference. General purpose streaming sewer makes use of a RTSP protocol for streaming controls such as message passing with client players. To date, there has been minimal research regarding streaming server's performance test tools. For measuring streaming server's performance, performance evaluation technique is needed and also achieved by RTSP based controls, a server's performance result and its miscellaneous test tools such the PseudoPlayer for pumping data to a specified port and the PseudoMonitor for gathering information. In this paper, We implement a test toolkit for evaluating a streaming server's performance and show the case of its application

  • PDF

The Home-based Program for Child with Sensory Modulation Disorder: Case Study (감각조절장애 아동에 대한 가정 프로그램의 적용 - 사례연구)

  • Lee, Ji-Young;Kim, Sung-Eun
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.5 no.1
    • /
    • pp.41-49
    • /
    • 2007
  • Objective: To evaluate the effectiveness of the home-based program composed of sensory diet for child with sensory modulation disorder. Method: The subject underwent the home-based program composed of sensory diet for 8 months. Evaluation tools we used are the Developmental Screening Test II(DDSTII) for developmental screening; the Short Sensory Profile(SSP), clinical observation and the clinical history record form for sensory integrative function; the Motor-Free Visual Perception Test(MVPT) and draw a person test for visual perception. Evaluation was executed before and after the program is provided. Results: The subject has showed remarkable improvement in developmental level, sensory integrative function and visual perceptual ability after went through the home-based program. Conclusion: The home-based program composed of sensory diet is effective for children with sensory modulation disorder when it is difficult to apply classical sensory integrative approach.

  • PDF

A case study on the evaluation of pile damage during driving by PDA testing. (PDA 시험을 이용한 말뚝손상 판단에 관한 사례 연구)

  • 송명준;박영호;이영남
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.334-341
    • /
    • 2002
  • Nowadays, owing to the development of analysis techniques for PDA test, we can evaluate the serious damage of pile during driving in site. In this study, we checked the damage of pile by pulling it out after evaluation of the pile damage during driving by PDA testing. After that, almost damaged pile was checked and the outline depth of damage could be verified. To increase the quality of driven pile, we have to increase the number of PDA testing for drivability analysis with checking the damage especially for preliminary pile driving and dynamic load test for checking the bearing capacity and consider the application of driving by energy monitoring.

  • PDF

A case study on the vibration by fluid induced instability at large steam turbine-generator (대형 터빈-발전기에서의 유체 불안정진동 해소사례)

  • Han, Seung-Woo;Noh, Chel-Woo;Kim, In-Chul;Joo, In-Gouk;Kim, Myong-Shik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1066-1071
    • /
    • 2007
  • This case study refers to turbine-generator with retrofitted turbine rotor. Vibration problem occurring after the retrofit was mainly due to high vibration from exciter side. However, repeated test run and operation during scheduled maintenance caused high vibration from generator bearing, and post-overhaul test run before turbine vibration correction caused oil whip on the bearing. This case study shows how to analyze vibration condition of high turbine generator vibration detected during the post-overhaul test run and vibration condition of offline and online data to reflect it on establishing maintenance schedule and overhaul correction procedure. Vibration data could be acquired during steady load operation or even with varying speed and load. Each data is important for machinery condition evaluation. This case study shows that the vibration data during extreme condition is the key factor in analysis, which helps to find the machinery problem.

  • PDF

A Case Study on the Vibration by Fluid Induced Instability at Large Steam Turbine-generator (대형 터빈-발전기에서의 유체 불안정진동 해소사례)

  • Han, Seung-Woo;Roh, Cheol-Woo;Yoo, Mu-Sang;Kim, In-Chul;Joo, In-Gouk;Kim, Myong-Shik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.2
    • /
    • pp.238-246
    • /
    • 2008
  • This case study refers to turbine-generator with retrofitted turbine rotor. Vibration problem occurring after the retrofit was mainly due to high vibration from exciter side. However, repeated test run and operation during scheduled maintenance caused high vibration from generator bearing, and post-overhaul test run before turbine vibration correction caused oil whip on the bearing. This case study shows how to analyze vibration condition of high turbine generator vibration detected during the post-overhaul test run and vibration condition of offline and online data to reflect it on establishing maintenance schedule and overhaul correction procedure. Vibration data could be acquired during steady load operation or even with varying speed and load. Each data is important for machinery condition evaluation. This case study shows that the vibration data during extreme condition is the key factor in analysis, which helps to find the machinery problem.

Evaluation of Structural Stiffness Degradation and Burst Pressure Measurement of the FM Kick-Motor Combustion Case (킥모터 FM 규격 연소관에 대한 강성저하 평가 및 파열압력 측정)

  • Yi, Moo-Keun;Cho, In-Hyun;Kim, Joong-Suk;Lee, Won-Bok
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.72-77
    • /
    • 2010
  • A hydraulic test on a filament wound case of Kick-Motor was conducted to evaluate the structural stiffness degradation and to confirm the burst performance. Failure criteria have been defined with bursting above 150% of MEOP(Maximum Expected Operation Pressure) and failure in the cylinder. The analysis result showed that filament fiber in the cylinder should be broken at about 2088psig. From a hydraulic test it has been verified that composite case meets the failure requirements, and that the stiffness does not decrease even after a year since the manufacturing.

Experimental Study on Evaluation of Abrasion Resistance of Concrete Irrigation Facilities (콘크리트 수리구조물의 수중마모저항성 평가기술에 관한 실험적 연구)

  • Kim, Meyongwon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.3
    • /
    • pp.123-133
    • /
    • 2018
  • The purpose of this paper is to propose an experimental method to evaluate the resistance of abrasion about 24 MPa, 27 MPa, and 30 MPa compressive strength. These strength are used in the design and construction of concrete hydraulic structures in Korea. The mixing ratios of the ready mixed concrete strengths were investigated countrywide and set the representative mixture proportion ratios of the nine mixed types of OPC, FA and BFS. After making and curing the test specimens, the underwater abrasion test was performed. ASTM C 1138 International Standard was used to fabricate the test equipment, and the surface abrasion resistance of the specimen was tested using the test equipment. In the case of OPC, the 30% abrasion resistance improvement effect was observed at 72 hours as the water-binder ratio decreased. That was reason the coated cement bond strength of the specimen was strong. In the case of BFS and FA, it was improved by 9.9% and 3.8%, respectively, at 72 hours as the water-binder ratio decreased. It was due to the characteristics of the latent hydraulic and pozzolanic reactions. Generally, the relative abrasion resistance of concrete can be evaluated at 24 hours. However, in case of low strength (under 24 MPa), the surface mortar layer wears much faster at the first 12 hours, so it can be considered to evaluate the relative abrasion loss rate at this point.