• Title/Summary/Keyword: Temperature test equipment

Search Result 330, Processing Time 0.024 seconds

Quality characteristics comparative study on the stone board which it processes with the polishing and flame burner (연마와 화염버너로 가공한 석판재의 품질특성 비교연구)

  • Kang Ji-Ho;Jang Myoung-Hwan
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.11a
    • /
    • pp.189-195
    • /
    • 2004
  • It compared quality characteristics for the stone surface treatment system and its products. With the result, the flame burner equipment was mainly used to the surface treatment of granite, but it occurred greatly the high temperature, the rock fragment, the noise and dust. For the other side, the whetstone polishing machine for the polishing was a maintenance for the specific physical properties of stone, and it did not occur the stone fragment and the dust. The durability of the stone products due to the flame burner was investigated with that it falls to $20\sim25\%$ more than the surface treatment by the whetstone polishing. Share's hardness of the polishing products in the durability test showed more greatly index than the flame burner and conventional product. The polishing products of Pochon stone in the case of the abrasion resistance showed great more $15\%$ than the general products, more $9\%$ than the products by the flame burner.

  • PDF

초정밀 선형 모터의 열.진동 분석

  • 임경화;이우영;설진수;김현철
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2004.05a
    • /
    • pp.163-168
    • /
    • 2004
  • Linear motor can directly apply to the system needed linear mot ions without rotary mot ions. To control a high-speed and high-resolution, the development of the linear motors is recently required in the high-integrated and speed process industry. This paper presents vibration analyses as well as measurement standards of the newly developed linear motors through analyzing the vibration characteristics and thermal behaviors of the advanced products. Vibration experiments are conducted for identifying the hysteresis and vibration level during operation. They are also included in the modal test to analyze the vibration. Analytic data using Finite Element Method (FEM) are compared with the results of the modal. Loss of temperature generated the linear motor leads to a serious deformation within its parts. The thermal behaviors are very important factor in linear motor. The FEM and experiments make it possible to understand these characteristics.

  • PDF

Assessment of Materials Degradation in a Hydrogen Environment (수소환경에서의 재료 열화도 평가)

  • Won, Sun-Ho;Hyeon, Yang-Gi;Lee, Jong-O;Lee, Jae-Do;Jo, Gyeong-Sik
    • 연구논문집
    • /
    • s.31
    • /
    • pp.149-156
    • /
    • 2001
  • Hydrogen damage affects carbon steel tubes in many fossil-fuel-fired boilers, often causing large tube ruptures that necessitate an immediate shutdown. Therefore, equipment handling high-temperature, high-pressure hydrogen must undergo careful periodic inspection because of its susceptibility to hydrogen attack. This paper describes the application of an ultrasonic technique for detecting the presence of hydrogen damage in utility boiler tubes. The accuracy of the technique has been shown in laboratory tests. However, it is difficult to evaluate hydrogen attack quantitatively by this technique, because ultrasonic wave is influenced by the test conditions and the material itself.

  • PDF

Research on the Development of High Radio-Frequency Electrode Probe for Under-Water Treatment (수중 치료용 고주파 전극 프로브 개발에 관한 연구)

  • Tea-Ho Yoon;Woo-Cheol Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1337-1344
    • /
    • 2023
  • We aim to find out the effectiveness of performance evaluation to ensure safety of performance through development of high-frequency electrode probes, evaluation test protocol and evaluation simulator that is essential to ensure safety in performance evaluation and reliability evaluation of high-frequency electrode probes for underwater therapy used with high-frequency electrosurgical equipment.

Compatibility Assessment of Copper Alloy and Hydrocarbon Fuel for Regeneratively Cooled Combustion Chamber (재생냉각 연소기용 구리합금과 연료 적합성 검증시험)

  • Lim Byoung-Jik;Kim Jong-Gyu;Kang Dong-Hyuk;Kim Hong-Jip;Kim Hui-Tae;Han Yeoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.100-109
    • /
    • 2006
  • In the regeneratively cooled combustion chambers using hydrocarbon fuels, coking occurs as the wall temperature increases which generates compounds deposition on the wall. This phenomenon reduces cooling capability of the coolant, finally it can cause damage to combustor by overheating of chamber wall. In this paper electrical heating equipment which is used for the coking experiments and the test results are introduced. The compatibilities of copper alloy with let A-1 were assessed at each condition based on the test results.

  • PDF

Measurement of Radiative Heat Flux of Kick Motor at Ground Test (킥 모터 지상 시험의 플룸 복사 열유속 측정)

  • Kim, Seong-Lyong;Choi, Sang-Ho;Ko, Ju-Yong;Kim, In-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.440-443
    • /
    • 2008
  • Plume radiation has been measured during ground tests of KSLV-I kick motor in order to predict the thermal load on the equipment around the kick motor at flight. The measuring positions are the kick motor base, and the measured heats were about 2${\sim}$5 w/cm$^2$. The measured heat showed a lot of shot fluctuation in their values, and the radiative heats at the latter half of time are higher than those of the first half. A plausible explanation for these phenomena was given as the variation of alumina particles with time. The radiative heats along the plume axis were also measured recently at 8 positions with 1.5m radius from plume axis, but only the initial parts of the results could be acceptable because the sensor were damaged by the accumulated heat. The strongest heat occurred at the middle of the plume, which can be explained with different view factors. Despite of the plausible explanation, it seems to need more analysis because the plume structure such as temperature, alumina particle, after burning has not been revealed until yet. The measure heat flux has been reflected in the prediction of the plume radiation at high altitude where the kick motor operates.

  • PDF

Temperature and Pressure Measurement on the Flame Deflector during KSLV-I Flight Tests (나로호 비행시험을 통한 화염유도로의 온도 및 압력 측정)

  • Jung, Il-Hyung;Moon, Kyung-Rok;Kang, Sun-Il;An, Jae-Chel;Ra, Seung-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.4
    • /
    • pp.378-384
    • /
    • 2011
  • During the flight test of KSLV-I, various sensors are installed in the launch pad and the flame deflector to measure the flame characteristics and their influences on the launch complex when a launch vehicle lifts off. Parameter Measurement System is responsible for acquiring the above flight test data. The measurement methodology such as the configuration of measurement system, sensor locations and data acquisition procedures are presented. And this paper compares and explains the characteristics of data sets measured during two flight tests.

Thermal Characteristics of Foams and Discharge of Fire-Protection Foam Spray Nozzle (폼 분무 노즐 방사 분포 및 폼의 열적 특성 연구)

  • Kim, Hong-Sik;Kim, Youn-Jea
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.151-158
    • /
    • 2005
  • A characteristic of discharge for a foam spray nozzle with various parameters was investigated. The discharge patterns from a fire foam spray nozzle are important to evenly spray over a maximum possible floor area. Two parameters of a foam spray nozzle were chosen, and compared with those from the standard one. Also, in order to evaluate the performance of discharged foam agents used to protect structures from heat and fire damages, the thermal characteristics of fire-protection foams were experimentally investigated. A simple repeatable test for fire-protection foams subjected to fire radiation was developed. This test involves foam generation equipment, a fire source for heat generation, and data acquisition techniques. Results show that the bubble size of foam is increased by large inside diameter of orifice or closed air hole, but phenomenon of discharge angle and expansion ratio is opposite. For the case of the open air hole, liquid film of a circular cone discharges with formation, growth, split and fine grain. In case of the closed air hole, a pillar of foam solution discharges with that. Though the temperature gradient in the foam increases with increased foam expansion ratio. it is not change with increased intensity of heat flux.

Quality Variable Prediction for Dynamic Process Based on Adaptive Principal Component Regression with Selective Integration of Multiple Local Models

  • Tian, Ying;Zhu, Yuting
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.4
    • /
    • pp.1193-1215
    • /
    • 2021
  • The measurement of the key product quality index plays an important role in improving the production efficiency and ensuring the safety of the enterprise. Since the actual working conditions and parameters will inevitably change to some extent with time, such as drift of working point, wear of equipment and temperature change, etc., these will lead to the degradation of the quality variable prediction model. To deal with this problem, the selective integrated moving windows based principal component regression (SIMV-PCR) is proposed in this study. In the algorithm of traditional moving window, only the latest local process information is used, and the global process information will not be enough. In order to make full use of the process information contained in the past windows, a set of local models with differences are selected through hypothesis testing theory. The significance levels of both T - test and χ2 - test are used to judge whether there is identity between two local models. Then the models are integrated by Bayesian quality estimation to improve the accuracy of quality variable prediction. The effectiveness of the proposed adaptive soft measurement method is verified by a numerical example and a practical industrial process.

Development of Cylindrical Paperpot Manufacturing Equipment (원통형 종이포트 제조장치 개발)

  • Park, Minjung;Lee, Siyoung;Kang, Donghyeon;Kim, Jongkoo;Son, Jinkwan;Yoon, Sung-wook;An, Sewoong
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.242-248
    • /
    • 2017
  • This study was conducted to develop a cylindrical paperpot manufacturing equipment which is capable of continuously producing paperpots with a constant size. The equipment consists of the soil supply part, the paper supply part, the pot manufacturing part, the paperpot cutting part and its process for manufacturing paperpot from the soil supply to the paperpot cutting is continuously performed. As a result of the performance test using this equipment, we suggest that the optimal moisture content and injection pressure to supply soil are 50%~60%, and 0.5 Mpa respectively. Moreover the appropriate temperature for adhesive strength is $150{\sim}160^{\circ}C$ taking into account the performance of device and adhesion time. Also, considering the cutting speed and safety, it is appropriate to adopt a straight blade having a clean plan at a minimum angle of $30^{\circ}$. In addition, the manufacturing capacity of the developed equipment was 3300 pots per hour.