• 제목/요약/키워드: Temperature monitoring system

검색결과 1,129건 처리시간 0.028초

대전지역 대기오염물질농도와 천식 환자수의 관련성 (Concentration of Air Pollutants and Asthma in Taejon City)

  • 서원호;장성실;권호자
    • 한국환경보건학회지
    • /
    • 제26권2호
    • /
    • pp.80-90
    • /
    • 2000
  • To determine the effect of air pollutants in Taejon City, we used medical insurance claim data for asthma and the data monitored from telemetry system of Ministry of Environment for air pollutants and meteorological factors. From November 1st, 1997 to October 31th, 1998, 95,629 asthma patients were covered by medical insurance at Taejon City. Subjects were composed of 49,563 males (51.8%) and 46.336 females(48.2%), and among the subjects, the proportion under 15 years old was 62.8% of the total. During the study period, daily mean concentrations of each air pollutants-So2, No2, CO, O3 and TSP-were 9.8 ppb, 17.6 ppm, 1.414 pp, 17.3 ppb and 60.6 $\mu\textrm{g}$/㎥, respectively, which were lower than each of the environmental recommended exposure levels, Through the simple correlation analysis between each air pollutants and meteorological factors, O3 was positively correlated with temperature, but negatively with relative humidity. TSP, SO2, NO2, CO were negatively correlated with meteorological factors, and these air pollutants except O3 were positively correlated with each other, O3 was correlated with TSP positively but the others negatively. Estimating relative risks of each air pollutant with the baseline general additive model, daily mean concentrations of TSP(Lag 0, 1, 4, 5day) were significantly associated with the increase of the asthma admission. Two age subgroups, under 15 and 15~54 have shown various association of all air pollutants concentration with the asthma admission. However, in case of over 54 age subgroup, only TSP(Lag 0 day) among all air pollutants was associated with the asthma admission. Each of ambient outdoor pollutant concentrations in Taejon City are significantly associated with the admission of asthma patients even though all concentrations in Taejon City are significantly associated with the admission of asthma patients even though all concentrations were much lower than the environmental recommended exposure levels. Therefore, continuous effort lowering air pollutant concentration and introducing an active environmental conservation policy should be implanted for preventing hazardous health effects. Considering major proportion of asthma admissions, high susceptibility and less confounding factors among the age subgroup under 15 will be a useful target population for assessing such health effect monitoring.

  • PDF

비디오 흉강경을 이용한 다한증의 교감신경 절제술 (Thoracoscopic Sympathectomy in Hyperhidrosis)

  • 성숙환;임청;김주현
    • Journal of Chest Surgery
    • /
    • 제28권7호
    • /
    • pp.684-688
    • /
    • 1995
  • Hyperhidrosis, one of the abnormalities in autonomic nervous system, has been treated with dermatologic principles or thoracic sympathectomy via conventional axillary thoracotomy or dorsal spinal approach. But these techniques were rather ineffective or invasive. Recently, VATS is widely applied in thoracic surgical area, and hyperhidrosis is not the exception of these cases.From May 1993 to August 1994, 30 patients with bilateral palmar hyperhidrosis underwent bilateral thoracic [T2, T3 sympathectomy with thoracoscopic surgery at Seoul National University Hospital. There were 20 men and 10 women and the mean age was 23.0 years.Mean operating time was 115 min and there was no thoracotomy conversion. Operative complications were anesthetic overdose in 1, Horner`s syndrome in 1, and small amount of residual pneumothorax in 6. Mean postoperative hospital stay was 2.3 days [range from 1 to 4 days and postoperative analgesics were required in 17 cases with a single dose.Sweating amount was measured in 12 patients, showing significantly decreased amount from 284.5 mg preoperatively to 18.9 mg postoperatively in 5 minutes [p=0.004 . There was no recurrence during mean 6 months follow up. Twenty two patients [73.3 % complained moderate compensatory hyperhidrosis on the trunk.In conclusion, all patients were greatly satisfied with those results including no more palmar sweating, less pain, better cosmetics, short hospital stay. In addition, recent use of sweating amount measurement and intraoperative temperature monitoring could make this technique more accurate, so we easily applied thoracoscopic sympathectomy with minimal risk.

  • PDF

Qualitative Analysis and Plasma Characteristics of Soil from a Desert Area using LIBS Technique

  • Farooq, W. Aslam;Tawfik, Walid;Al-Mutairi, Fahad N.;Alahmed, Zeyad A.
    • Journal of the Optical Society of Korea
    • /
    • 제17권6호
    • /
    • pp.548-558
    • /
    • 2013
  • In this work, laser induced breakdown spectroscopy (LIBS) is used to investigate soil samples collected from different desert areas of Riyadh city in Saudi Arabia. Both qualitative analysis and plasma parameters are studied via the observed LIBS spectra. These experiments have been done using a Spectrolaser-7000 system with 50 mJ fundamental wavelength of Nd:YAG laser and detection delay time of 1 microsecond. Many spectral lines are highly resolved for many elements like Al, Fe, Mg, Si, Mn, Na, Ca and K. The electron temperatures Te and electron densities Ne, for the constituent of generated LIBS plasma, are determined for all the collected samples. It is found that both Te and Ne vary from one desert area to other. This variation is due to the change of the elemental concentration in different desert areas that affects the sample's matrices. Time dependent measurements have also been performed on the soil samples. While the signal-to-base ratio (SBR) reached its optimal value at 1 microsecond, the plasma parameters Ne and Te reach values of $4{\times}10^{17}cm^{-3}$ and 9235 K, respectively, at 2.5 microsecond. The later indicate that the plasma cooling processes are slow in comparison to the previously observed results for metallic samples. The observed results show also that in the future it is possible to enhance the exploitation of LIBS in the remote on-line environmental monitoring application, by following up only the values of Ne and Te for one element of the soil desert sample using an optical fiber probe.

Design of the Control and Monitoring Architecture for the KVN 4 Channel Receiver System using Profibus

  • Song, Min-Gyu;Byun, Do-Young;Je, Do-Heung;Kang, Yong-Woo;Wi, Seog-Oh;Lee, Sung-Mo;Lee, Jung-Won;Chung, Moon-Hee;Kim, Seung-Rae;Jung, Tae-Hyun;Lee, Eui-Kyum;Lee, Sang-Hyun;Hwang, Jung-Wook
    • 천문학회보
    • /
    • 제43권2호
    • /
    • pp.57.3-57.3
    • /
    • 2018
  • KVN 수신기는 22/43/86/129GHz 주파수 대역의 우주전파를 관측할 수 있는 4채널 동시 관측 시스템의 핵심으로 다수의 제어 및 모니터 항목이 존재한다. 대표적인 예로 Synthesizer, Pcal, LO, Vacuum, Cryogenic Temperature 등이 있으며 이와 관련된 여러 인스트루먼트가 21m 전파망원경의 하부단에 위치한 수신기실 내에 분산 배치되어 있다. 이에 대한 효율적인 제어를 위해서는 사용자 컴퓨터 관점에서 두 가지 조건이 충족되어야 한다. 첫째, 물리적으로 분산된 인스트루먼트에 대한 접근 및 변경이 용이해야 하고, 둘째는 단일 인터페이스 상에서 다양한 인스트루먼트를 하나로 통합하는 확장성이 보장되어야 한다. 이러한 요건을 고려하여 KVN은 산업 분야에서 널리 쓰이고 있는 프로피버스를 수신기 시스템의 제어를 위한 기반 인터페이스로 활용 중에 있고, 추가 기능 요구에 효율적으로 대처하고 있다. 본 발표에서는 먼저 KVN 수신기 시스템을 구성하는 인스트루먼트에 대해 살펴보고자 한다. 그리고 이를 효율적으로 제어하기 위한 기반 인터페이스로서 프로피버스 구축 및 활용 현황에 대해 논하고자 한다.

  • PDF

광학특성을 가진 수질변수를 활용한 하구 담수호 내 TOC 농도 추정 (Estimating TOC Concentrations Using an Optically-Active Water Quality Factors in Estuarine Reservoirs)

  • 김진욱;장원진;신재기;강의태;김진휘;박용은;김성준
    • 한국물환경학회지
    • /
    • 제37권6호
    • /
    • pp.531-538
    • /
    • 2021
  • In this study, the TOC in six estuarine reservoirs in the West Sea (Ganwol, Namyang, Daeho, Bunam, Sapkyo, and Asan) was estimated using optically-active water quality factors by the water environment monitoring network. First, specification data and land use maps of each estuarine reservoir were collected. Subsequently, water quality data from 2013 to 2020 were collected. The data comprised of 11 parameters: pH, dissolved oxygen, BOD, COD, suspended solids (SS), total nitrogen, total phosphorus, water temperature, electrical conductivity, total coliforms, and chlorophyll-a (Chl-a). The TOC in the estuarine reservoirs was 4.9~7.0 mg/L, with the highest TOC of 7.0 mg/L observed at the Namyang reservoir, which has a low shape coefficient and high drainage density. The correlation of TOC with water quality factors was also analyzed, and the correlation coefficients of Chl-a and SS were 0.28 and 0.19, respectively, while the correlation coefficients of these factors in the Namyang reservoir were 0.42 and 0.27, respectively. To improve the estimation of TOC using Chl-a and SS, the TOC was averaged in 5 mg/L units, and Chl-a and SS were averaged. Correlation analysis was then performed and the R2 of Chl-a-TOC was 0.73. The R2 of SS-TOC was 0.73 with a non-linear relationship. TOC had a significant non-linear relationship with Chl-a and SS. However, the relationship should be assessed in terms of the spatial and temporal variations to construct a reliable remote sensing system.

사물인터넷 프로토콜 기반의 미세먼지 측정 플랫폼 설계와 기능해석 (Design and Function Analysis of Dust Measurement Platform based on IoT protocol)

  • 조용찬;김정호
    • Journal of Platform Technology
    • /
    • 제9권4호
    • /
    • pp.79-89
    • /
    • 2021
  • 본 논문은 사물인터넷 국제 표준 oneM2M을 활용하여 미세먼지(PM10)와 초미세먼지(PM2.5) 측정 플랫폼을 이동식과 고정식으로 설계하였다. 미세먼지 측정 플랫폼은 미세먼지 측정 디바이스, 에이전트, oneM2M 플랫폼, oneM2M IPE, 모니터링 시스템으로 구성하고 설계하였다. 이동식과 고정식의 주요 차이는 이동식은 LTE 연결을 기반으로 사각지대 없이 디바이스와 서비스간에 상호연결을 위해 MQTT 프로토콜을 사용하였고, 고정식은 저전력과 넓은 통신범위를 가진 LoRaWAN 프로토콜을 사용하였다. 미세먼지뿐만 아니라 일상생활과 연관된 온도, 습도, 대기압, 휘발성 유기화합물(VOC), 일산화탄소(CO), 아황산가스(SO2), 이산화질소(NO2), 소음 데이터를 수집하였다. 수집된 센서 값들은 에이전트와 oneM2M IPE를 통해 oneM2M이 제공해주는 공통 API를 활용하여 관리하였고, AE, container 등 4가지 리소스 타입으로 설계하였다. 미세먼지 측정 플랫폼 설계를 통해 동작성, 유연성, 편의성, 안전성, 개방성, 확장성의 6가지 기능을 해석하였다.

스마트팜 센서 처리용 MCU 모듈 설계 (MCU Module Design for Smart Farm Sensor Processing)

  • 김관형
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.285-286
    • /
    • 2021
  • 최근 IoT(Internet of Things) 기술의 발전으로 스마트화 기술이 농업, 축산업, 수산업 분야로 확장되어 스마트화가 진행되고 있다. 이러한 스마트화 기술은 현장의 데이터를 어떻게 계측하여 관리 시스템으로 전송하는가가 무엇보다 중요하다. 현재 스마트팜 및 기타 축사 및 양식장 구축에 활용되는 센서는 온도, 습도, CO 가스, CO2, 수소(Hydrogen), O2 등 다양한 센서를 통하여 스마트팜 및 기타 환격을 계측하고 모니터링하고 있다. 이러한 센서들과 스마트팜을 제어하고 관리하는 HMI(Human Machine Interface) 모듈과의 통신방식은 아직 까지는 RS-485 기반의 모드버스(modbus-RTU) 방식을 주로 활용하고 있다. 본 논문에서는 스마트팜 구축에 필요한 센서 데이터를 HMI 모듈에서 관리할 수 있도록 RS-485 기반의 모드버스 방식을 통하여 데이터를 관리할 수 있도록 다양한 센서 모듈을 연결할 수 있도록 HMI용 MCU 모듈을 설계하고자 한다.

  • PDF

고준위방사성폐기물 처분장 모니터링용 피에조센서의 온도 스트레스에 관한 가속수명시험 설계 (Design of accelerated life test on temperature stress of piezoelectric sensor for monitoring high-level nuclear waste repository)

  • 황현중;박창희;홍창호;김진섭;조계춘
    • 한국터널지하공간학회 논문집
    • /
    • 제24권6호
    • /
    • pp.451-464
    • /
    • 2022
  • 고준위방사성폐기물 처분장은 심지층 처분시스템으로 사용후핵연료를 취급하는 특성상 고온, 방사선 및 지하수 등의 복합적인 환경조건에 노출되어 있다. 지속적인 노출에 의해 시간이 지남에 따라 구조물의 균열 및 열화가 발생할 수 있다. 한편 고준위방사성폐기물 처분장은 초장기 기대수명이 요구되며 이에 따른 장기적인 구조물 건전성 모니터링이 필수적이다. 구조물 건전성 모니터링에는 가속도계, 토압계, 변위계 등 다양한 센서들이 활용될 수 있으며, 이 중 일반적으로 피에조센서가 사용된다. 따라서 피에조센서의 내구성 평가를 바탕으로 고내구성 센서를 개발할 필요가 있다. 본 연구에서는 피에조센서의 내구성 평가 및 수명예측을 위한 가속수명시험을 설계하였다. 문헌연구를 바탕으로 단일 스트레스 인자에 대한 가속 스트레스 수준 수 및 각 수준 별 시료 수를 선정하였다. 또한 고준위방사성폐기물 처분장 환경조건에서 발생할 수 있는 피에조센서의 고장모드 및 고장메커니즘을 분석하였다. 온도 스트레스 인자에 대한 최대 가혹조건 탐색 실험을 두 가지 방법으로 제안하였으며 피에조센서의 신뢰도 높은 동작한계를 도출하였다. 이를 이용하여 가속수명시험의 합리적인 가속 스트레스 수준을 설정하였다. 본 연구에서 제시된 최대 가혹조건 탐색 실험방법은 경제적이며 실용적인 아이디어를 담고 있으며, 추후 피에조센서의 가속수명시험 설계에 널리 활용될 수 있을 것으로 판단된다.

공주 청량사지 오층석탑 및 칠층석탑의 정밀 계측모니터링과 미세거동 해석 (Interpretation of Microscale Behaviors and Precision Measurement Monitoring for the Five-story and Seven-story Stone Pagodas from Cheongnyangsaji Temple Site in Gongju, Korea)

  • 이정은;박석태;이찬희
    • 헤리티지:역사와 과학
    • /
    • 제56권4호
    • /
    • pp.132-158
    • /
    • 2023
  • 공주 청량사지 오층 및 칠층석탑은 계룡산 삼불봉 아래에 있으며, 고려 중기에 창건한 것으로 알려진 탑으로 한 시대에 두 유형의 백제계 석탑이 공존하는 쌍탑으로서 역사적 및 학술적 가치를 인정받고 있다. 두 탑은 1944년 도굴로 칠층석탑이 전도되고 그 영향으로 오층석탑에 기울어짐이 발생하였다. 1961년에 석탑을 복원하였으나 구조적 불안정성은 지속적으로 제기되었다. 따라서 이 연구에서는 2021년 5월부터 2022년 3월까지 계측자료를 축적하고 계절적 특성을 검토하여, 동일 기간의 기온변화와 강수량에 따른 석탑의 미세거동을 해석하였다. 이 결과, 모든 계측기에서 일간 기온변화에 따라 미세한 열탄성거동을 반복하였으며, 경사와 변위 모두 미세거동이 나타났다. 경사계에서는 기온변화에 따라 석재의 표면과 내부에 포함된 수분이 팽축을 반복하며 미세한 움직임을 보였고, 변위계에서도 시계열에 따라 기온이 상승하면서 모두 이격거리가 감소하였다. 특히 오층석탑 상부는 북서쪽으로 최대 3.89° 거동하였으며, 칠층석탑은 북동쪽으로 최대 0.078° 기울었다. 최대 변위는 오층석탑과 칠층석탑에서 각각 0.127 및 0.149mm로 기록되었다. 이 값들은 계측 종료시점에 원래 상태로 회귀하는 경향은 있으나 완전히 회복하지 못하여 면밀한 감시가 필요한 상태를 지시하였다. 이 연구를 통해 획득한 결과는 두 석탑의 안정적 보존을 위한 기초자료로 활용될 수 있다. 이를 기반으로 다양한 환경요소를 고려한 거동특성이 분석되어야 하며, 계측시스템의 유지관리를 통한 예방보존이 지속되어야 할 것이다.

충남지역 다중이용시설의 환경수계에서 분리한 레지오넬라균의 특성 분석 (Characterization of Legionella Isolated from the Water System at Public Facilities in Chungcheongnam-do Province)

  • 천영희;이현아;남해성;최지혜;이다연;고영은;박종진;이미영;박준혁
    • 한국환경보건학회지
    • /
    • 제47권5호
    • /
    • pp.472-478
    • /
    • 2021
  • Background: The Legionella case detection and notification rate have increased in public artificial water environments where people visit, including large buildings, public baths, and hospitals. Objectives: In this study, the distribution of Legionella and its epidemiologic characteristics were analyzed in the water systems of public facilities in Chungcheongnam-do Province in South Korea. Methods: Culture and PCR analysis were performed on 2,991 environmental water system samples collected from 2017 to 2019, and associations with year, facilities, seasons, and temperature of water system were statistically analyzed by using R-Studio for Windows. Descriptive data was compared using chi-square tests and independent t-tests. Results: The detection rate of Legionella increased from 3.1% in 2017 to 10.3% in 2019, appearing most frequently in the order of public baths, large-scale buildings, hospitals, and apartments. It was detected mainly in summer from June to August, over 1.0×103 CFU/L on average in 133 cases (66.5%). Lots of germs were detected in bathtub water, cooling tower water, and warm water (p<0.001), and it was detected at higher rates in the cities where multipurpose facilities were concentrated than in rural areas (p=0.018). Conclusions: This study suggests that continuous monitoring and control are required for Legionella in the water system environment of high risk facilities. Moreover, these results will be helpful to prepare efficient management plans to prevent the Legionellosis that occurs in Chungcheongnam-do Province.