Loading [MathJax]/jax/output/CommonHTML/jax.js
  • Title/Summary/Keyword: Temperature field measurement

Search Result 614, Processing Time 0.036 seconds

Transient loss analysis of non-insulation high temperature superconducting coil using the field-based data profiling method

  • Hoon Jung;Yoon Seok Chae;June Hee Han;Ji Hyung Kim;Seung Hoon Lee;Ho Chan Kim;Young Soo Yoon;Ho Min Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.3
    • /
    • pp.38-42
    • /
    • 2023
  • The evaluation of no-insulation (NI) high-temperature superconducting (HTS) typically uses the lumped equivalent circuit (LEC) model. Constant parameters in the NI HTS LEC model accurately predict voltage and central magnetic field at currents below the critical current. However, it is difficult to find constant circuit parameters that simultaneously satisfy the measured voltage and magnetic field under overcurrent conditions. Recent research highlights changes in contact resistance during transient conditions, which may impact power loss estimation in NI HTS coils. Therefore, we confirm the influence of contact resistance changes on loss calculation in the transient state for NI HTS coil. To achieve this, we introduce a measurement data analysis method based on the LEC model and compare it with the LEC model using constant circuit parameters.

Development of monitoring device with thermal line sensors and its use for grouting and leakage problems (그라우팅과 누수 문제에 대처한 온도센서 배열 모니터링 장치 개발)

  • Kim, Jung-Yul;Honarmand, H.;Kim, Yoo-Sung;Nam, Ji-Yeon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.509-516
    • /
    • 2004
  • The measurement of abnormal change of temperature(temperature anomaly) will help determine the safety of various engineering constructions, as the measurement in body often used to diagnose one's health. Temperature anomaly can be occurred in leakage or seepage of water flow in rocks, and in ground water table etc. Grouting materials injected in fractured rocks generate heat during hardening process. The degree of temperature change is associated directly with heat flow characteristics, that is, thermal conductivity, specific heat capacity. density of the surrounding rocks and can afford to assess the grouting efficiency. However, in practice, the use of traditional temperature measuring technique composed of only one single thermal sensor has been fundamentally limited to acquire thermal data sufficient to use for that, partly due to the time-consuming measuring work, partly due to the non-consecutive quality of data. Thus, in this paper, a new concept of temperature measuring technique, what we call, thermal line sensor technique is introduced. In this, the sensors with an accuracy of 0.02 are inserted at regular intervals in one line cable and addressed by a control device, which enables to fundamentally enhance the capability of data acquisition in time and space. This new technology has been demonstrated on diverse field model experiments. The results were simply meant to be illustrative of a potential to be used for various kinds of temperature measurements encountered in grouting and leakage problems.

  • PDF

Methods of temperature measurement of medium in bottle during sterilization (병재배 배지살균 시 배지내부의 실시간 온도측정 방법)

  • Cheong, Jong-Chun;Jhune, Chang-Sung;Lee, Chan-Jung;Oh, Jin-A;Shin, Pyeong-Gyun
    • Journal of Mushroom
    • /
    • v.9 no.2
    • /
    • pp.74-79
    • /
    • 2011
  • This study was carried out to develop a method related to measuring the temperature of sterile medium in bottle cultivation. When the medium is sterilized, the device is able to be inserted inside of the medium and the temperature can be directly measured in real time although high temperature and pressure are detected in the sterilization. This device can be able to measure the sterilization temperature in short intervals inside of autoclave and medium used in bottle cultivation. As the method were applied to the field cultivation of mushroom, we could produce mushroom in consistent manner through the optimum sterilization of the medium.

Planar Laser-Induced Fluorescence (PLIF) Measurements of a Pulsed Electrothermal Plasma Jet

  • Kim, Jong-Uk;Kim, Youn J.;Byungyou Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1808-1815
    • /
    • 2001
  • The characteristics of a pulsed plasma jet originating from an electrothermal capillary discharge have been investigate using laser-induced fluorescence (LIF) measurement. Previous emission measurements of a 3.1 kJ plasma jet show trial upstream of the Mach disk the temperature and electron number density are about 14,000 K and and 10\^17/ cm\^-3/, while downstream of the Mach dick tole values are about 25,000 K and 10\^18/ cm\^-3/, respectively. However, these values are barred on line-of-sight integrated measurements that may be misleading. Hence, LIF is being used to provide both spatially and temporally resolved measurements. Our recent work has been directed at using planar laser-induced fluorescence (PLIF) imaging of atomic copper in the plasma jet flow field. Copper is a good candidate for PLIF studies because it is present throughout the plasma and has electronic transitions that provide an excellent pump-detect strategy. Our PLIF results to date show that emission measurements may give a misleading picture of the flow field, as there appeals to be a large amount of relatively low temperature copper outside the barrel shock. which may lead to errors in temperature inferred from emission spectroscopy. In this paper, the copper LIF image is presented and at the moment, relative density of atomic copper, which is distributed in the upstream of the pulsed plasma jet, is discussed qualitatively.

  • PDF

A Study on Monitoring of Gas Temperature in Boiler Furnace (보일러 화로내 연소가스 온도분포 구현에 관한 연구)

  • Jang, Seok-Won
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.188-193
    • /
    • 2006
  • This paper intends to present theoretical study and its application result of the way of the temperature distribution embodiment through the production of subdivided nod's temperature from the average, maximum and minimum temperature following acoustic speed measurement with a set of acoustic speed meters at the arbitrary section in the furnace. By measuring the acoustic speed between the speed meters, flue gas temperature field can be determined. Then Subdivided arbitrary grid's temperatures can be infered out of surrounding nod's temperature distribution, and finally the entire grid's temperature distribution will be found. In this article, theoretical background, related system setup. and real application result are examined and discussed.

Heat Flow Studies in Low Temperature Detectors (저온검출기의 열전도 연구)

  • Kim, Il-Hwan;Lee, Min-Kyu;Kim, Yong-Hamb
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.41-45
    • /
    • 2010
  • Low temperature micro-calorimeters have been employed in the field of high resolution alpha spectrometers. These alpha detectors typically consist of a superconducting or metal absorber and a temperature sensor. The temperature sensor can be a transition edge sensor (TES), a metallic magnetic calorimeter (MMC) or other low temperature detectors for an accurate measurement of temperature change due to an alpha particle absorption. We report a recent study of the heat flow between a replaceable absorber and a temperature sensor. A piece of gold foil in 2.4×2.7×0.03mm3 is used as an absorber. A 40μm diameter Au:Er paramagnetic sensor is attached to another small piece of gold foil in 400×200×30μm3 to serve as the temperature sensor. This sensor assembly, Au:Er and gold foil, is placed on a miniature SQUID susceptometer in a gradiometric configuration. The thermal connection between the absorber and the sensor was made with three gold bonding wires. The measured thermal conductance shows a linear dependence to the temperature. The values are in a good agreement with Wiedemann-Franz type thermal conductance of the gold wires.

Characteristics of CNT Field Effect Transistor (탄소나노튜브 트랜지스터 특성 연구)

  • Park, Yong-Wook;Na, Sang-Yeob
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.1
    • /
    • pp.88-92
    • /
    • 2010
  • Bottom gate and top gate field-effect transistor based carbon nanotube(CNT) were fabricated by CMOS process. Carbon nanotube directly grown by thermal chemical vapor deposition(CVD) using Ethylene (C2H4) gas at 700C. The growth properties of CNTs on the device were analyzed by SEM and AFM. The electrical transport characteristics of CNT FET were investigated by I-V measurement. Transport through the nanotubes is dominated by holes at room temperature. By varying the gate voltage, bottom gate and top gate field-effect transistor successfully modulated the conductance of FET device.

A Study on Ozone Passive Sampler (II) -Interference and Field Application (오존간이 측정기에 대한 연구(II)-간섭현상 및 현장 적용성)

  • Jeong, Sang-Jin;Yang, Hee-Jun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.904-911
    • /
    • 2006
  • Passive sampler is simple and inexpensive measuring equipment for air pollution. In this study we developed colorimetric ozone passive sampler which was coated a colorimetric reagent to a filter substrate. Interference of criteria all pollutant (SO2,NO2,CO) on ozone passive sampler was investigated through experimental chamber. Field measurement of developed ozone passive samper was compared automatic sampler result in Suwon area. The results shows interference of SO2 gas is larger than other gases. Developed passive sampler can be roughly applicable to wind speed range from 0.8 to 3.3 m/s, temperature range from 3.9 to 27.5C and relative humidity range from 48 to 84%.

Flow field Analysis In Puffer Type Interrupters of GIS/GCB (파퍼형 GIS/GCB의 유동특성 해석)

  • Song, K.D.;Shin, Y.J.;Park, K.Y.;Choi, Y.G.;Song, W.P.;Kang, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1512-1516
    • /
    • 1994
  • FLIC(Fluid in cell) method has been used for analyzing a cold gas flow field in an interrupter of a circuit treater since 1970s. In this paper FLIC method is applied to calculation of a cold gas flow and then combined with the simple are analysis method in order to investigate the flow field characteristics in a puffer type interrupter rated at 145kV 40kA. The results for a cold gas flow agree with the experimental measurement well. The other results such as pressure rise, arc temperature, post-arc current and so forth am also reasonable and show the possibility that the combined program can be applied to the design of UHV interrupters.

  • PDF

Improvements to the stability of electric field sensors

  • Lee, Dong-Oh;Robert Boston;Dietrich W. Langer;Joel Falk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.495-496
    • /
    • 1998
  • The measurement of the amplitude and phase of electric fields on high voltage transmission lines is important for several reasons including a) Metering and determination of power flow, b) protective relaying. and c) fault sensing. The work reported here is directed toward a major improvement to optically based, electric-field sensors. This is a signal processing based technique for overcoming the instabilities of conventional, optically-based, electric-field sensors to changes in optical power or temperature.

  • PDF