• 제목/요약/키워드: Temperature calculation

검색결과 1,452건 처리시간 0.026초

자동차 에틸렌글리콜 부동액의 혼합 농도 측정 장치 개발 (Device Development of Mixture Concentration of Ethylene Glycol Antifreeze Coolant for Vehicles)

  • 이대웅;이은웅
    • 설비공학논문집
    • /
    • 제28권8호
    • /
    • pp.331-336
    • /
    • 2016
  • This study presents a coolant density calculation device and its corresponding method by using a mass flowmeter and the LabVIEW program. The method can be easily measured with a mixture of coolant and by calculating the percentage of ethylene-glycol without additional investment. The cooling water is very important in a vehicle to protect the engine, and the cooling performance is affected by the mixture concentration and coolant density. The coolant density calculation device measures the mixed concentration in the anti-freeze cooling mixture made from distilled water and ethylene-glycol in real time with the mass flowmeter that is commonly attached to the radiator or heater core. The calculation program for the mixture concentration percentage was developed using the LabVIEW software. The correlation between experimental results and the calculation was conducted for a range of temperature from 40 to $90^{\circ}C$ and by varying the mixture ratio of distilled water and ethylene-glycol. As a result, the anti-freeze coolant concentration in the volume percentage is able to monitor the coolant density in a timely basis by implementing a mixture concentration calculation program without the need for additional equipment investment. The results of the calculation for the mixture concentration level show a maximum 2.7% deviation compared to the experimental results.

FDM에 의한 응고해석시 계산기간 단축을 위한 Algorithm연구 (Efficient Algorithm for the Solidification Simulation by FDM)

  • 이재경;전주매;전기찬
    • 한국주조공학회지
    • /
    • 제14권5호
    • /
    • pp.412-418
    • /
    • 1994
  • Efficient algorithm for the solidification simulation by FDM is described from the practical point of views. If a proper time step ${\Delta}t$ is selected, the calculation is accelerated by implicit algorithm with the temperature recovery method of latent heat method. The implicit routine in the calculation is processed by SOR method(relaxation factor=1.5, truncation error=$10^{-4}$). The calculation is more accelerated by linear-interpolated explicite algorithm with a time step larger than the minimum value of the time step. This explicit method, which is applicable to the practical casting simulation problems, produces almost same results with about 40% faster calculation speed compared with the conventional explicit method.

  • PDF

NiSi에의 Co 치환에 대한 ab-initio 계산 (Ab-initio calculation on Co substitution into NiSi)

  • 김영철;서화일
    • 한국재료학회지
    • /
    • 제17권7호
    • /
    • pp.358-360
    • /
    • 2007
  • Cobalt subtitution on NiSi is investigated by using an ab-initio calculation. Firstly, a relaxed NiSi structure is calculated and the calculated lattice parameters are compared with experimentally determined lattice parameters. The calculated values are smaller than the experimental values by about 2%. As the calculation is based on 0 K, and the experimental measurement is performed at room temperature, those values are in good agreement. Next, a Co atom substitutes a Ni and Si site, respectively, to evaluate the preferable site between them. Co prefers Ni site to Si site. The calculated total energy also indicates that the Co substitution to Ni site stabilizes the NiSi structure. Therefore, the thermal stability of NiSi with Co addition can be achieved by the structure stabilization of NiSi by Co substitution into Ni site of NiSi.

전력 변환 장치 효율 개선을 위한 손실 분석 연구 (Loss Analysis of Power Conversion Equipment for Efficiency Improvement)

  • 김민국;우동균;이병국;김남준;김종수
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.80-90
    • /
    • 2014
  • This paper suggests loss analysis and calculation methods for efficiency improvement of power conversion equipment in detail. The detailed loss analysis and calculation has been conducted for 3.3kW On-board Battery Charger considering temperature condition. The validity of the analysis and calculation method is verified by simulation model.

열회로 방식에 의한 Disc type motor의 온도상승 계산 (Temperature rise calculation of a disc type motor with heat source method)

  • 박창순;장기찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.43-46
    • /
    • 1991
  • Nd-Fe-B Permanent Magnet, which is recently more used, has some advantages in comparison with other permanent magnet. However, for the Nd-Fe-B has higher RTC(reversible temperature coefficient), property of the Nd-Fe-B magnet is changed by temperature rise. In this paper temperature rise of a disc type motor is calculated using a heat source network method.

  • PDF

변태잠열을 고려한 담금시편의 온도 및 조직분포에 대하여 (On the distribution of temperature and metallic structures in quenching process considering latent heat of phase transformation)

  • 민수홍;구본권
    • 오토저널
    • /
    • 제6권4호
    • /
    • pp.46-53
    • /
    • 1984
  • The analysis of temperature distribution and change of metallic structures during water quench were presented by finite element method. In temperature calculation the equation of unsteady state hear conduction problem considering latent heat due to phase transformation was applied to finite solid cylinder, SM 45C of 40mm diameter and 40mm height. In metallic structure analysis iso-thermal transformation curve and the equations of evolution in pearlite-martensite transformation were applied. The calculated results upon temperature and metallic structures were agreed with those of experimental observations.

  • PDF

A Numerical study of the fluctuation behavior of the oxygen concentration and the temperature in the silicon melt of Czochralski crystal growth system

  • Yi, Kyung-Woo;Kim, Min-Cheol
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1997년도 Proceedings of the 12th KACG Technical Meeting and the 4th Korea-Japan EMGS (Electronic Materials Growth Symposium)
    • /
    • pp.197-201
    • /
    • 1997
  • The momentum, heat and mass trasfer phenomena in the silicon melt of the Czochralki crystal growth system are calculated using a three dimensional numerical simulation thechnique. Even though axisymmetrical boundary conditions are imposed to all calculations in a 3cm diameter crucible, several types of non-axisymmetric profiles of velocities, temperature and oxygen concentration appeared in the melt. Because of the non-axisymmetric profiles of velocities, temperature and oxygen concentration appeared in the melt. Because of the non-axisymmetric profiles and rotations of fluid induced by the crucible rotation, temperatures and oxygen concentrations in the silicon melt fluctuate. The rotating velocity of the profile is calculated from the phase shift of the data of temperature or oxygen at two different points which have same radius from center but 90 degree angular difference. From this calculation, it is found that the rotating veolocity of the oxygen and temperature is different from the crucible rotation rates. Therefore the frequencies of the oscillating temperature and oxygen concentrations are not same to the frequencies of the crucible rotations. Futhermore, the components of the frequencies of the temperature and oxygen concentration at the same point are not same. The fluctuation behaviors of the temperature or oxygen themselves are also different when the points are different. The calculation show that the temperature and the oxygen concentration near the interface also fluctuate. The results suggest that the striation pattern found in the grown silicon single crystals may ben generated by the oxygen concentration and the temperature oscillations of the melt occurred near the interface.

  • PDF

멀티존 온돌난방제어를 위한 필요공급온수온도 산출법에 관한 연구 (A Study on the Required Supply Water Temperature Calculating Method for the Control of Multizone Radiant Floor Heating System)

  • 최정민;이규남;류성룡;김용이;여명석;김광우
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.77-85
    • /
    • 2007
  • One of the most common approaches to achieve better thermal comfort with the radiant floor heating system is supply water temperature control, which is that supply water temperature is varied with outdoor air temperature. But the application of this control method was not easy, because there has been no way to determine the supply water temperature. So in this study, a comprehensive, yet simple calculation method to find out the required supply water temperature is suggested by combining the building heat loss equation and the heat emission model of hydronic radiant floor heating system for single zone. And then using this calculation method, the multizone control method is suggested and confirmed through the thermal simulation. It is shown that indoor air temperature is stably maintained around the set point.

C3H8-SiCl4-H2 시스템에서의 탄화 실리콘 증착에 대한 열역학적인 해석 (Thermodynamic Prediction of SiC Deposition in C3H8-SiCl4-H2 System)

  • 김준우;정성민;김형태;김경자;이종흔;최균
    • 한국세라믹학회지
    • /
    • 제48권3호
    • /
    • pp.236-240
    • /
    • 2011
  • In order to deposit a homogeneous and uniform ${\beta}$-SiC films by chemical vapor deposition, we demonstrated the phase stability of ${\beta}$-SiC over graphite and silicon via computational thermodynamic calculation considering pressure, temperature and gas composition as variables. The ${\beta}$-SiC predominant region over other solid phases like carbon and silicon was changed gradually and consistently with temperature and pressure. Practically these maps provide necessary conditions for homogeneous ${\beta}$-SiC deposition of single phase. With the thermodynamic analyses, the CVD apparatus for uniform coating was modeled and simulated with computational fluid dynamics to obtain temperature and flow distribution in the CVD chamber. It gave an inspiration for the uniform temperature distribution and low local flow velocity over the deposition chamber. These calculation and model simulation could provide milestones for improving the thickness uniformity and phase homogeneity.

Performance Analysis of a Triple Pressure HRSG

  • Shin, Jee-Young;Son, Young-Seok;Kim, Moo-Geun;Kim, Jae-Soo-;Jeon, Yong-Joon
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1746-1755
    • /
    • 2003
  • Operating characteristics of a triple pressure reheat HRSG are analyzed using a commercial software package (Gate Cycle by GE Enter Software). The calculation routine determines all the design parameters including configuration and area of each heat exchanger. The off-design calculation part has the capability of simulating the effect of any operating parameters such as power load, process requirements, and operating mode, etc., on the transient performance of the plant. The arrangement of high-temperature and intermediate-temperature components of the HRSG is changed, and its effect on the steam turbine performance and HRSG characteristics is examined. It is shown that there could be a significant difference in HRSG sizes even though thermal performance is not in great deviation. From the viewpoint of both economics and steam turbine performance, it should be carefully reviewed whether the optimum design point could exist. Off-design performance could be one of the main factors in arranging components of the HRSG because power plants operate at various off-design conditions such as ambient temperature and gas turbine load, etc. It is shown that different heat exchanger configurations lead to different performances with ambient temperature, even though they have almost the same performances at design points.