• 제목/요약/키워드: Temperature Drop

검색결과 1,122건 처리시간 0.026초

건조 온도 및 경화시간이 도공지 품질에 미치는 영향 (Effect on the Properties of Coated Paper by Drying Temperature and Curing Time)

  • 박동국;최희연;김영하;이용규
    • 펄프종이기술
    • /
    • 제34권4호
    • /
    • pp.16-21
    • /
    • 2002
  • It was observed that drying temperature and curing time in the paper coating process as well as Tg of the latex used as a binder, greatly affected the properties of the coated paper such as roughness, paper and print gloss, K & N ink drop, and ink set-off. The higher drying temperature induced faster water evaporation and change in binding density, which caused an increase in paper roughness, ink gloss and ink set-off, but decrease in paper gloss and K & N ink drop. The increased curing time promoted latex filming and redistribution of the binder in coating layer. This increased pick strength and ink gloss, but decreased ink trapping. Finally, the higher Tg of the latex showed the wider changing range of these properties.

적외선 복사에너지에 의한 시료의 물리적 손상 측정 (Measurement of Physical Demage of Samples by Infrared Radiation)

  • 정동선;김기훈;한종성;김훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.131-135
    • /
    • 2004
  • The molecules of the substance absorbing a light obtains the radiant energy to the wavelength of the light to make thermal reactions or photochemical reactions. Specially, thermal reactions by infrared radiation brings about physical damage by temperature rise process or temperature drop process of the material. In this study, a measuring system was set up to measure the temperature rise and temperature drop of each sample by infrared radiation from light source. And a physical demage of samples by infrared radiation were measured using the measuring system.

  • PDF

R407C의 온도구배와 과열도가 증발기 성능에 미치는 영향 (Effects of the Temperature Glide and Superheat of R407C on the Performance of Evaporator)

  • 김창덕;전창덕;이진호
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.852-859
    • /
    • 2003
  • R407C is considered as an alternative refrigerant of R22 for air conditioners. An experiment was carried out to investigate the characteristics of the evaporation heat transfer and pressure drop for refrigerant R407C flowing in a fin-and-tube heat exchanger used for commercial air-conditioning unit. The experimental data were useful in analyze the effects of the temperature glide and superheat for R407C. Test were conducted at the conditions of inlet refrigerant evaporation temperature of 7$^{\circ}C$, inlet air relative humidity of 50%, and refrigerant mass fluxes varying from 150 to 250 kg/m$^2$s. Representative results show that the heat exchanger performance for R407C evaporation is significantly affected by the change of the flow pattern from two-phase to super-heated vapor flow.

한국형 기동장비 마찰재의 고온성능 연구 (A Study on the High Temperature Performance of the Brake Materials Built in Korean Model Combat Vehicle)

  • 하상준;정동윤
    • 한국군사과학기술학회지
    • /
    • 제3권2호
    • /
    • pp.53-60
    • /
    • 2000
  • Organic brake materials are installed in the braking system of korean model combat vehicles. Since the binder resin is decomposed in high temperature region, it may possible to drop the friction force which makes the vehicle stop within the desired distance. This study analyses the braking performance of the brake materials in high temperature region by using the pin-on-disk type friction tester. It is observed radical drop of friction coefficients and rapid increase of wear amounts from the transition temperature. It is due to the formation of oxide layer on the friction surface.

  • PDF

극저온 환경에서의 정 출력 제어를 적용한 마이크로터빈의 새로운 시동 로직 개발 (New Start-Up Logic for Microturbine by Constant Power Control under an Extremely Low Temperature)

  • 노민식
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1249-1255
    • /
    • 2006
  • This paper presents a constant power control logic for perfect starting a microtubine in vehicle. Under extremely low temperature, performance of the start-up system is severely dropped than that of room temperature because of increasing of load of mechanical parts including engine core and drop of the lead-acid battery capacity. Unfortunately, performance drop of lead-acid battery makes severe problems that cause a malfunction of fuel and lubrication system and power fail of digital devices. So we propose the new start-up logic by constant output power control of lead-acid battery using PWM inverter controller for preventing above problems and keeping good performance of start-up system for microturbine. Also, we prove usefulness of new start-up logic through experimental results under $-32^{\circ}C$ ambient temperature.

한중 환경에서의 유로폼 내부 철근의 온도 변화 (Temperature Variation of Reinforcement Bars Located in an Euro-form Before Placing Concrete in a Cold Weather Condition)

  • 이명호;김경훈;백병훈;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.71-72
    • /
    • 2013
  • This study investigates the effect of the diameters of reinforcement bars located in an euro-form before placing concrete in a cold weather condition. The diameters of reinforcement bars with 13 mm, 19 mm, 25 mm and 32 mm were prepared for the experimental tests. Results showed that the larger the size of the diameter of the bars, the higher were the temperature drop. However, this study found that its effect on the temperature drop of the bars was insignificant.

  • PDF

응축기의 설계조건에서 R22, R407C, R410A의 압력강하 예측 및 실험 (Prediction and Experiment of Pressure Drop of R22, R407C and R410A on Design Conditions of Condenser)

  • 김창덕;박일환;이진호
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.42-53
    • /
    • 2004
  • An experimental study on the refrigerant-side pressure drop of slit fin-tube heat exchanger has been carried out. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the pressure drop on design conditions of condenser in micro-fin tube for R22 and its alternatives, R407C (R32/125/134a, 23/25/52 wt.%) and R410A (R32/125, 50/50 wt.%). Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and mass fluxes varying from 150 to 250 kg/$m^2$s for R22, R407C and R410A. The inlet air conditions are dry bulb temperature of 35$^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.43 m/s. Experiments show that pressure drop for R410A and R407C were 17.8∼20.2% and 5∼6.8% lower than those of R22 respectively for the degree of subcooling of 5$^{\circ}C$. For the mass fluxes of 200∼250 kg/$m^2$s, the deviation between the experimental and predicted values for the pressure drop was less than $\pm$20% for R22, R407C and R410A.

세관내 이산화탄소의 증발 열전달 및 압력강화 (Evaporation Heat Transfer and Pressure Drop of $CO_2$ in a Small diameter Tube)

  • 장승일;최선묵;김대희;박기원;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.189-194
    • /
    • 2005
  • The evaporation heat transfer and pressure drop of $CO_2$ in a small diameter tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 $kg/m^2s$, saturation temperature of $0^{\circ}C$ to $20^{\circ}C$, and heat flux of 10 to 20 $kW/m^2$ . The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The evaporation pressure drop of C02 are highly dependent on the mass flux. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient and pressure drop of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient and friction pressure drop of $CO_2$ in a horizontal tube.

  • PDF

하절기 효율적인 하우스 온도 습도 관리에 관한 연구 (Studies on Management of Effective Temperature and Humidity in Greenhouse at Summer Season)

  • 우영회;남윤일;송천호;김형준;김동억
    • 생물환경조절학회지
    • /
    • 제3권1호
    • /
    • pp.58-65
    • /
    • 1994
  • 본 시험은 하절기 경제성을 고려한 효율적인 온도하강방법을 구명하고자 차광재료, fog system, 송풍등 복합적 온도하강처리에 따른 비닐하우스의 기상환경변화를 조사하여 다음과 같은 결과를 얻었다. 1. 중형하우스에서 온도하강방법에 따른 환경특성은 처리에 따라 하우스의 고온화를 상당히 효율적으로 억제하였다. 7월31일 하우스냉방처리에 따른 기온의 일중변화를 경시적으로 보면 수분의 증발잠력능력을 이용한 fog system과 은색차광 및 송풍을 혼합하여 처리할 경우 기온과 지온은 외기온에 비하여 최고 각각 1$0^{\circ}C$, 4$^{\circ}C$정도 온도하강효과가 있었으며 그 다음은 은색차광+fog system, 은색차광+송풍, 흑색차광+송풍구 순이였다. 2. 하절기 가장 온도가 높은 시기인 7월20일부터 8월21일까지 하우스냉방처리에 따른 온도하강 효과를 보면 최고기온은 시험처리에 따라 온도차가 인정되며 은색차광+fog system+송풍구의 지상, 지표면기온은 외기온에 비하여 각각 약 8$^{\circ}C$, 7$^{\circ}C$정도 온도하강 효과가 있었다. 3. 은색차광+송풍구와 흑색차광+송풍구의 일사량은 청명한날 외기일사량에 비하여 각각 약 29.3%, 32.5%이였으며 흐린 날은 각각 약 27.4%, 31.8%이였다.

  • PDF

폴리에틸렌의 절연파괴와 그의 온도 및 두께의존성 (A Study on Thickness and Temperature Dependence of Dielectric Breakdown in Polyethylene)

  • 김점식;이종범;정우교;김미향;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1388-1390
    • /
    • 1995
  • The characteristic of dielectric breakdown in solid insulating material dominates the reliability and safety of power equipment and affects directly to its life. In this point of view, the thickness and temperature dependence of dielectric breakdown strength and mechanism of dielectric breakdown in low density polyethylene which has been employed widely as insulating material have been technically reviewed by examinations of thermal property. The dielectric breakdown strength depending on its thickness was measured 2.6[MV/cm] at the thickness of 20[${\mu}m$] and 1.9[MV/cm] at the thickness of 75[${\mu}m$] based on ambient temperature of 30[$^{\circ}C$]. It is shown the temperature dependence that dielectric breakdown strength decreases in linear as the thickness increases. The dielectric breakdown strength depending on temperature was measured 2.6[MV/cm] at the temperature of 30[$^{\circ}C$], 1.6[MV/cm] at 60[$^{\circ}C$] and 1.3[MV/cm] at 90[$^{\circ}C$] based on the thickness of 20[${\mu}m$]. As the ambient temperature increases, the temperature dependence is shown that a very large drop is occurred up to temperature of 60[$^{\circ}C$] and a very small drop is discovered over 60[$^{\circ}C$].

  • PDF