• Title/Summary/Keyword: Temperature Accuracy

Search Result 1,772, Processing Time 0.025 seconds

Optimal Variable Selection in a Thermal Error Model for Real Time Error Compensation (실시간 오차 보정을 위한 열변형 오차 모델의 최적 변수 선택)

  • Hwang, Seok-Hyun;Lee, Jin-Hyeon;Yang, Seung-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.215-221
    • /
    • 1999
  • The object of the thermal error compensation system in machine tools is improving the accuracy of a machine tool through real time error compensation. The accuracy of the machine tool totally depends on the accuracy of thermal error model. A thermal error model can be obtained by appropriate combination of temperature variables. The proposed method for optimal variable selection in the thermal error model is based on correlation grouping and successive regression analysis. Collinearity matter is improved with the correlation grouping and the judgment function which minimizes residual mean square is used. The linear model is more robust against measurement noises than an engineering judgement model that includes the higher order terms of variables. The proposed method is more effective for the applications in real time error compensation because of the reduction in computational time, sufficient model accuracy, and the robustness.

  • PDF

An Improvement of Positioning Accuracy for CNC Machine Tools (CNC 공작기계의 위치결정 정밀도 향상에 관한 연구)

  • JEON, Eon Chan;HIROTA, Yasuhiro;TSUTSUMI, Masaomi;NAMGUNG, Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.5-11
    • /
    • 1994
  • We have investigated the variation of dwell and warm-up time for effects of positioning accuracy of the CNC machine tools with an laser measuring system. Also, we strdied the effect of improvement of the positioning accuracy by variation of the temperature for hollow ball screw, which mostly used as drive mechanism of CNC machine tools. We dbtained the effectiveness of cooling effect of the new cooling system, compared with the conventional cooling system.

  • PDF

Evaluation of Measurement Accuracy for Unmanned Aerial Vehicle-based Land Surface Temperature Depending on Climate and Crop Conditions (기상 조건과 작물 생육상태에 따른 무인기 기반 지표면온도의 관측 정확도 평가)

  • Ryu, Jae-Hyun
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.2
    • /
    • pp.211-220
    • /
    • 2021
  • Land Surface Temperature (LST) is one of the useful parameters to diagnose the growth and development of crop and to detect crop stress. Unmanned Aerial Vehicle (UAV)-based LST (LSTUAV) can be estimated in the regional spatial scale due to miniaturization of thermal infrared camera and development of UAV. Given that meteorological variable, type of instrument, and surface condition can affect the LSTUAV, the evaluation for accuracy of LSTUAV is required. The purpose of this study is to evaluate the accuracy of LSTUAV using LST measured at ground (LSTGround) under various meteorological conditions and growth phases of garlic crop. To evaluate the accuracy of LSTUAV, Relative humidity (RH), absolute humidity (AH), gust, and vegetation index were considered. Root mean square error (RMSE) after minimizing the bias between LSTUAV and LSTGround was 2.565℃ under above 60% of RH, and it was higher than that of 1.82℃ under the below 60% of RH. Therefore, LSTUAV measurement should be conducted under the below 60% of RH. The error depending on the gust and surface conditions was not statistically significant (p-value < 0.05). LSTUAV had reliable accuracy under the wind speed conditions that allow flight and reflected the crop condition. These results help to comprehend the accuracy of LSTUAV and to utilize it in the agriculture field.

A Study on Pressing Conditions in the molding of Aspheric Glass Lenses for Phone Camera Module using Design of Experiments (DOE를 적용한 카메라폰 모듈용 비구면 Glass 렌즈의 가압성형조건 연구)

  • Kim, Hye-Jeong;Cha, Du-Hwan;Lee, Jun-Key;Kim, Sang-Suk;Kim, Jeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.720-725
    • /
    • 2007
  • This study investigated the pressing conditions in the molding of aspheric glass lenses for the mega pixel phone camera module using the DOE method. Tungsten carbide (WC; Japan, Everloy Co., 002K),which contained 0.5 w% cobalt (Co), was used to build the mold. The mold surface was ultra-precision ground and polished, and its form accuracy (PV) was 0.85um in aspheric surface. We selected four factors, pressing temperature, force and time of first step, and force of second step, respectively, as the parameters of the pressing process. in order to reduce the number of experiments, we applied fractional factorial design considering the main effects and two-way interactions. The analysis results indicate that the only two main effects, the pressing temperature and the time of pressing step 1, are available for the form accuracy (PV) of the molded lens. The analysis results indicated that the best combination of the factors for lowering the form accuracy(PV) value of molded lens was to have them at their low levels.

Analysis of Effect by Duration of Cryotherapy in the Posterior region of Neck for College Students

  • Ji Hong Chang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.301-306
    • /
    • 2023
  • Attention is a fundamental aspect in the cognitive process of human. Cognitive system of human body requires to focus on selected information among a vast amount of information from sensory organs. It has widely studied that various environmental factors affected the level of attention; however, few researches have aimed to the effect of direct cryotherapy. In this research, level of attention was studied comparing sub-indexes of FAIR test between groups with different duration of direct cryotheapy to the back of neck. FAIR test is a evaluation tool for visual attention consisting of three sub-indexes. Selective attention, accuracy of attention, and persistence of attention can be independently analyzed by FAIR test. In the analysis of selective attention, cryotherapy for 5 to 20 minutes showed higher result than cryotherapy for 40 minutes. In the analysis of persistence of attention, cryotherapy for 5 to 15 minutes showed higher result than cryotherapy for 40 minutes. Overall, selective attention and persistence of attention turns out to be maximized between 5 to 20 minutes of cryotherapy and tends to decrease afterwards. However, accuracy of attention does not seem to be affected by the duration of cryotherapy. Correlation between selective attention and the skin temperature by cryotherapy tends to be negative supporting the findings by ANOVA and post-hoc test. Correlation between persistence of attention and the skin temperature showed similar results.

PCA-based filtering of temperature effect on impedance monitoring in prestressed tendon anchorage

  • Huynh, Thanh-Canh;Dang, Ngoc-Loi;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.22 no.1
    • /
    • pp.57-70
    • /
    • 2018
  • For the long-term structural health monitoring of civil structures, the effect of ambient temperature variation has been regarded as one of the critical issues. In this study, a principal component analysis (PCA)-based algorithm is proposed to filter out temperature effects on electromechanical impedance (EMI) monitoring of prestressed tendon anchorages. Firstly, the EMI monitoring via a piezoelectric interface device is described for prestress-loss detection in the tendon anchorage system. Secondly, the PCA-based temperature filtering algorithm tailored to the EMI monitoring of the prestressed tendon anchorage is outlined. The proposed algorithm utilizes the damage-sensitive features obtained from sub-ranges of the EMI data to establish the PCA-based filter model. Finally, the feasibility of the PCA-based algorithm is experimentally evaluated by distinguishing temperature changes from prestress-loss events in a prestressed concrete girder. The accuracy of the prestress-loss detection results is discussed with respect to the EMI features before and after the temperature filtering.

A Torque Compensation Method Considering Temperature Variation of SPMSM

  • Jung, Tae-Uk;Park, Chang-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.160-167
    • /
    • 2018
  • This paper analyzed the effect of temperature on the permanent magnet flux and output torque. The major parameter which will impact the torque control accuracy of a surface mounted permanent magnet motor is the variation of the permanent magnet temperature. In addition, the temperature variation of the permanent magnet will also influence the maximum torque per ampere of the motor. To analyze the effect of temperature on the permanent magnet, the rotor of the motor was directly heated to measure the temperature and the permanent magnet flux was measured. As a result, the output torque of the motor decreases as the temperature of the rotor permanent magnet increases. Therefore, this paper proposes a technique to compensate the phase current of the motor by estimating permanent magnet flux, and it is proved through theoretical basis and several experiments.

Measurement of the Volumetric Thermal Errors for CNC Machining Center Using the Star-type-styluses Tough Probe

  • Lee, Jae-Jong;Yang, Min-Yang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.111-117
    • /
    • 2000
  • One of the major limitations of productivity and quality in metal cutting is the machining accuracy of machine tools. The machining accuracy is affected by geometric errors, thermally-induced errors, and the deterioration of the machine tools. Geometric and thermal errors of machine tools should be measured and compensated to manufacture high quality products. In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models the thermal errors for error analysis and develops an on-the-machine measurement system by which the volumetric errors are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses and a designed spherical ball artifact (SBA). Experiments show that the developed system provides a high measuring accuracy, with repeatability of $\pm$2$\mu\textrm{m}$ in X, Y and Z directions. It is believed that the developed measurement system can be also applied to the machine tools with CNC controller. In addition, machining accuracy and product quality can be also improved by using the developed measurement system when the spherical ball artifact is mounted on a modular fixture.

  • PDF

Estimation of Thermal Behavior for the Machine Origin of Machine Tools using GMOH Methodology (GMOH 기법에 의한 공작기계 원점의 열적거동 예측)

  • 안중용
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.213-218
    • /
    • 1997
  • Thermal deformation of machine origin of machine tools due to internal and external heat sources has been the most important problem to fabricate products with higher accuracy and performance. In order to solve this problem, GMDH models were constructed to estimate thermal deformation of machine origin for a vertical machining ceneter through measurement of temperature data of specific points on the machine tool. These models are nonlinear equations with high-order polynomials and implemented in a multilayered perceptron type network structure. Input variables and orders are automatically selected by correlation and optimization procedure. Sensors with small influence are deleted automatically in this algorithm. It was shown that the points of temperature measurement can be reduced without sacrificing the estimation accuracy of $\pm$5${\mu}{\textrm}{m}$. From the experimental result, it was confirmed that GMDH methodology was superior to least square models to estimate the thermal behavior of machine tools.

  • PDF

Analysis of Positioning Error Factors in the Hydrostatic Tables (유정압테이블의 위치결정오차요인 분석)

  • Oh Y.J.;Park C.H.;Lee D.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.773-776
    • /
    • 2005
  • In this paper, For improving the positioning accuracy of hydrostatic table, relationship between temperature of atmosphere and thermal characteristics of hydrostatic table is analyzed, and influence of thermal characteristics on positioning accuracy is also analyzed experimentally. From the experimental results, it is confirmed that positioning error and repeatability is $0.21{\mu}m\;and\;0.18{\mu}m$ when the laser scale which has $0.01{\mu}m$ of resolution is used as feed-back unit. and also confirmed that thermal deformation of scale and supporter, which occurs by the temperature variation of atmosphere, works as limit of repeatability in long time operation.

  • PDF