• Title/Summary/Keyword: Teflon vial

Search Result 7, Processing Time 0.023 seconds

Evaluation of Effects on Tritium Measurement According to HTO Type Sample Preparation Conditions (HTO 형태 시료 조제 조건에 따른 삼중수소 계측에 미치는 영향 평가)

  • An, Eun-Mi;Kim, Jung-Hoon;Lee, Hong-Yeon;Han, Sang-Jun;Kim, Bo-Gil
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.381-387
    • /
    • 2021
  • In this study, for the measurement of 3H(tritium) radioactivity concentration, a study was conducted on whether the type of cocktail and the material of the vial had an effect on the measurement before liquid scintillation counter measurement on HTO-type samples that had undergone physical and chemical pretreatment. As a result of the study, the efficiency according to the type of cocktail was higher in Ultima Gold LLT than Ultima Flo-AP cocktail with polyethylene (1.49%), glass (5.10%), and teflon (6.58%), respectively. Regarding the effect according to the type of vial, the efficiency and SQP(E) of both Ultima Gold LLT and Ultima Flo-AP showed the highest values in the order of teflon, polyethylene, and glass.

Effect on the Measurement of Trace Element by Pressure Bomb and Conventional Teflon Vial Methods in the Digestion Technique (압력용기 산분해법과 테플론 바이알에서의 산분해법이 미량원소의 함량측정에 미치는 영향)

  • Lee, Seung-Gu;Kim, Taehoon;Tanaka, Tsuyoshi;Lee, Seung Ryeol;Lee, Jong Ik
    • The Journal of the Petrological Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.107-119
    • /
    • 2016
  • Trace element abundances in the igneous rocks are important data for petrogenetic interpretation. Their concentrations are generally measured using ICP-MS from the dissolved solution. The acid digestion of rock powder can be performed by conventional teflon vial or pressure bomb. In this paper, we investigated a problem that happened during acid digestion experiment using conventional teflon vial or pressure bomb of BCR2 and GSP2 USGS rock standard materials. The results show that the measured concentrations of the elements like Cr, Ni, Zn, Ta, W in the BCR2 are different from the recommended values of USGS whereas those of the elements like Rb, Sr, Zr, Hf, Ta, W in the GSP2 are different from those values. Our experiment shows that defect of specific elements like Cr, Ni may happen during the sample digestion. Our results also indicate that the Cr, Ni, W, Zr, Hf, Ta concentration obtained based on an acid digestion of geological samples need to be careful in their geochemical interpretation.

A Rapid Method for the Measurement of $^{222}Rn$ in Groundwater and Hot Spring Water using Ultra Low-Level Liquid Scintillation Counter and Pulse Shape Analysis (극저준위 액체섬광계수기와 파형분석법을 이용한 지하수 및 온천수중 $^{222}Rn$의 신속측정법)

  • Kim, Chang-Kyu;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.103-115
    • /
    • 1995
  • For the determination of $^{222}Rn$ in water by a very simple and time saving liquid scintillation counting method that does not require any chemical separation, an optimum analytical condition has been investigated. The optimum pulse shape analysis(PSA) level for the measurement of $^{222}Rn$ using LKB 1220 Quantulus liquid scintillation counter was 110 for Optiphase HiSafe3 cocktail and 90 for toluene-based cocktail. The counting efficiencies of $^{222}Rn$ in the window covering u spectra using Optiphase HiSafe3 cocktail were 282.2% for glass vial and 271.6% for Teflon vial, whereas the counting efficiencies in toluene-based cocktail were 262.3% and 247.5% for glass and Teflon vials, respectively. The minimum detectable activity(MDA) in the u window for a 60-min measurement with a Teflon vial using Optiphase HiSafe3 cocktail was $0.30Bq/{\iota}$. The analytical method studied from this work was also applied to the determination of $^{222}Rn$ in some groundwater and hot spring water samples.

  • PDF

Effect of Zircon on Rare-Earth Element Determination of Granitoids by ICP-MS (ICP-MS를 이용한 화강암내 희토류원소 분석시 저어콘이 미치는 영향)

  • Lee, Seung-Gu;Kim, Taehoon;Han, Seunghee;Kim, Hyeon Cheol;Lee, Hyo Min;Tanaka, Tsuyoshi;Lee, Seung Ryeol;Lee, Jong Ik
    • The Journal of the Petrological Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.337-349
    • /
    • 2014
  • We measured rare earth element and Zr concentrations of USGS granite standard material GSP-2 and GSJ granite standard material JG-1a to clarify the effect of zircon during rare earth element analysis using ICP-MS. We also measured rare-earth element and zirconium (Zr) contents of zircon from granite by acid-digestion methods using conventional teflon vial and pressure-bomb. The results show that acid-digestion using teflon vial dissolved ca. 50% of zircon compared to pressure-bomb method. The Zr contents of JG-1a and GSP-2 gave ca 50% of reference value. However, rare-earth element abundance of JG-1a and GSP-2 were similar to those of reference values. This suggests that the decomposition degree of zircon might give a negligible effect on a petrological and geochemical interpretation using chondritenormalized REE pattern.

Low level tritium analysis using liquid scintillation counter (액체섬광계수기를 이용한 저준위 트리튬 분석법연구)

  • Yoon, Yoon Yeol;Cho, Soo Young;Lee, Kil Yong;Kim, Yongje
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.419-423
    • /
    • 2007
  • Environmental low level tritium analysis was studied using liquid scintillation counter(LSC) and electrolytic enrichment method. To obtain low level blank count, various counting vials were investigated. Among them, teflon coated PE vial had a lower blank count rate (1.86 cpm) and we obtained 2.01 Bq/L detection and tritium separation factor was above 20. LSC counting efficiency obtained $28.70{\pm}0.27%$ using the NIST tritium standard water sample.

Effect Evaluation by Activity and Geometry Difference in Calibration on LSC (LSC 장비를 이용한 교정시 Activity 및 Geometry 차이에 의한 영향 평가)

  • Han, Sang-Jun;Lee, Kyung-Jin;Lee, Seung-Jin;Kim, Hee-Gang;Park, Eung-Seop
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.21-26
    • /
    • 2008
  • When the calibration on Liquid Scintillation Counter using the Solid $^3H$ Standard Source of 200,000DPM is executed, the uncertainty due to activity and geometry difference, exists. Therefore, this paper intends to evaluate environmental samples comparatively accurately as decreasing this uncertainty existing in the process of calibration. For this, measurements on samples manufactured by $^3H$ Standard Source and sensitivity study were performed. Also, this paper verified calibration results using Radioactivity-Error-Analysis Method, and evaluated quantitatively the effect by geometry and activity difference based on verification result. According to the result of sensitivity study, in case of using the exposure time of 75 sec and Repeat method, the measuring accuracy and precision of about $1{\sim}3%$ were increased in comparison with the existing method. By analysis result, the effect by activity difference did not appear, and a plastic cell existing into Teflon vial made a role as reflector. The less the effect of plastic cells are decreased, the more activity is high, and the effect of those can be neglected at the activity of 200,000 DPM.

Research on Measurement Condition Establishment of a Liquid Scintillation Counter System (액체섬광계수기 장비의 계측조건 확립에 관한 연구)

  • Park, Eung-Seop;Han, Sang-Jun;Lee, Seung-Jin;Kim, Hee-Gang;Lee, Na-Young;Mun, Ji-Yeon
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.155-164
    • /
    • 2006
  • It is judged that there could be certainty in every process of analyzing environmental samples using Liquid Scintillation Counter. Therefore, this study focuses on quantitative evaluation on uncertainty in an effort to analyze comparatively accurately environmental samples. For this, after parameters which can have an effect on uncertainty was derived, the evaluation on each parameter was tamed out. The results of analysis of each parameter showed that the effect according to the weight difference of Teflon vial did not appear, and that standard deviations of SQP(E) averages reached saturation point at $75{\sim}90$ sec at the result of making increases step by step the irradiation time of External standard, and that values measured by repeat method produces good results compared with replicate. Also, conclusion was derived that analysis on sample after it is left in cold and dark room at least above 1,000 minutes have to be carried out, and the result of carrying out verification on results measured as well as equipment itself using radioactivity-error-analysis and chi-square test, resonable result was derived.