• Title/Summary/Keyword: Teflon filter

Search Result 35, Processing Time 0.022 seconds

A Study on the Formation of Nitrate in the Atmosphere (환경 대기중 Nitrate의 생성에 관한 연구)

  • 천만영;강공언;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.68-73
    • /
    • 1992
  • A study on the formation of particulate nitrate$(NO_3^-)$ and gaseous nitrate$(HNO_3)$ in the atmosphere was carried out in Seoul from Oct 8 to 11 1991. To collect $NO_3^-$ and $HNO_3$ in the ambient air, dual filter pack sampler (47mm$\phi$) was used. In the dual filter pack sampler, the first filter was Teflon filter (poresize 1$\mum$) for collection of $NO_3^-$ and the second filter was Nylon filter (poresize 0.45 $\mum$) for $HNO_3$. Particulate nitrate$(NO_3^-)$ and Sulfate ions were analysed by Ion chromatography. $HNO_3$ concentration was higher in the day time $(9.93\mug/m^3)$ than the night time$(3.50\mug/m^3)$, and Particulate nitrate$(NO_3^-)$ concentration was higher in the night time and early morning$(6.21\mug/m^3)$ than the day time$(4.31\mug/m^3)$. The conversion rate of $NO_x$ to total nitrate$(NO_3^-, HNO_3)$ was 7.57%/hr in the day time and 4.79%/hr in the night time, and total average conversion rate was 5.60%/hr.

  • PDF

Design of 2.3 GHz BPF Using Microstrip Line Structure (테프론을 이용한 2.3 GHz 협대역 대역통과필터)

  • ;Mai Linh
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.148-150
    • /
    • 2002
  • In this paper, a 5-coupled BPF with teflon substrate is presented. In general, for less than 1 GHz frequency, the narrow bandwidth as well as the good characteristic in the rejection frequency band could be realized using lumped elements. However, for higher than 1 GHz frequency, the distributed elements such as microstrip lines need to be used for the design of the desired BPF For less than 2 GHz, the FR4 shows good filter characteristic at low cost. However, in the range of 2 GHz ~ 10 GHz, the filters with FR4 show a big difference between simulation and measurement results. Thus, in such a high frequency region, the teflon is more preferred to the FR4. The center frequency (fc) of the proposed filter is 2.3 GHz, the insertin loss (IL) is 1.2 dB, the return loss (RL) is 30 dB, bandwidth (BW) is 100 MHz, and the size is 8.3 cm $\times$ 4.9 cm.

  • PDF

A study on the Polymer surface treatment of GF-filter bag for collection of fine Particle like carbon black (카본블랙류 미세입자 포집을 위한 유리섬유 필터백의 고분자 표면처리에 관한 연구)

  • Lee, B.;Choi, H.L.;Moon, C.K.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.55-59
    • /
    • 2008
  • In this paper, we have investigated on collection efficiency of fine particle of glass fiber-filter bag according to the surface treatment. The solution consisted of polytetrafluoroethylene(teflon), graphite powder, silicon resin and water was used as a basic surface treatment agent. Tensile strength of glass filter-bag increased with up to 3hrs and then decreased with surface treatment time. Tensile strength and initial modulus of the glass fiber-filter bag treated by iodine after basic surface treatment for 3hrs were lower than those of basic surface treatment for 3hrs, however collection efficiency and fracture strain were higher than those of basic surface treatment for 3hrs. Glass fiber-filter bag with lower initial modulus and more strain will be extend the durable period and the one treated by iodine after basic surface treatment 3or 3hrs is expected high collection efficiency of fine particle. This method makes it possible to manufacture glass fiber-filter bag of the optimum condition.

  • PDF

Mutagenicity of Diesel-Exhaust Particulates

  • Yoo, Young S.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.E
    • /
    • pp.325-331
    • /
    • 1994
  • Organic extracts of diesel- exhaust particulates were analyzed for mutagenicity using Ames Salmonella typhimurium assay system. An experimental diesel microbus used was drived on the chassis dynamometer according to CVS-75 mode. The samples were taken from the mixed gases in a dilution tunnel. With a high-volume air sampler equipped with double filter holders, particulate matters were collected on a teflon-coated glass fiber filter placed behind a activated carbon filter. After ultrasonic extraction with benzene- ethanol and evaporation to dryness, the residue was dissolved in dimethylsulfoxide. Each sample was tested toward 2 strains, TA100 and TA98 by the pre-incubation method in the absence and presence of S-9mix. Average concentration of diesel- exhaust particulates was about 116.6mg/m$^3$, and 44.1~62.2 % to the total weight of particulates, consisted of organic matters. The mutagenicities of diesel- exhaust particulate organic matters were 4,512 and 2,205 revertants/m$^3$ toward TA100 without and with S-9mix, respectively. Those toward TA98 were 13,367 and 3,715 revertants/m$^3$, respectively.

  • PDF

A study on the pulp and paper mills waste water Recycling by VSEP membrane system (진동막 분리장치를 이용한 제지폐수의 재이용에 관한 연구)

  • 지은상;김재우;신대윤
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.40-46
    • /
    • 2001
  • Conventional membrane systems was difficult to treatment for pulp and paper mills waste warter. Technological advances in membrane filtration systems have created opportunity for pulp and paper mills to treat effluent streams in order to meet stricter environmental constraints. "Vibratory Shear Enhanced Processing(VSEP)" developed by new logic international makes if possible to filter effluent streams without the fouling problems exhibited by conventional membrane systems. Various kinds of waste water occurred to and paper mills experiment with "VSEP" set up conventional membrane. The results were as followes : Excepting ultra filter($0.1{\mu}\textrm{m}$ Teflon, C-100, G-50), Nano filter(NTR-7450, DS-5, PVD-1) and reverse osmosis(ACM-4) was treated with very excellent weight of treatment, electric conductivity, removal COD, TDS, turbidity.

  • PDF

A Design of Multi-layer Planar Type Microwave Filter (다층 평면형 초고주파 필터의 설계)

  • Lee Hong-Seop;Hwang Hee-Yong
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.4 no.1
    • /
    • pp.31-36
    • /
    • 2005
  • In this paper, a planar type bandpass filter in multilayered PCB is presented. The multilayered PCB structure has some advantages on fabricating microwave devices such as the size reduction and ability of tight coupling by folding or embedding. The proposed BPF has two transmission zeros at the both sides of the center frequency by using independent electric and magnetic coupling structure. The designed BPF with four layer teflon PCBs of dielectric constant 2.94 has dimensions of 24x20x1.524 in mm, center frequency of 2.47GHz and bandwidth of about l00MHz. A good agrement is achieved between the measured result and the simulated one. The influences of air gaps between the layers are also analyzed and presented.

  • PDF

Filter-based Correction for Positive Sampling Artifacts in the Determination of Ambient Organic Carbon (여과지를 이용한 유기탄소의 측정 오차 보정)

  • Kang, Byung-Wook;Yeon, Ik-Jun;Cho, Byung-Yeol;Park, Sang-Chan;Lee, Hak-Sung;Jeon, Jun-Min;Na, Kwang-Sam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.63-72
    • /
    • 2011
  • This study describes the impact of positive sampling artifact caused by a filter-based sampling in the determination of ambient organic carbon (OC). Three different sampling media combinations were employed for this investigation: (1) Quartz filter-alone (Q-alone), (2) quartz filter behind quartz-fiber filter (QBQ), and (3) quartz filter and quartz filter behind Teflon filter (Q-QBT). The measurement of ambient OC was carried out at a semi-urban site near oceanside at the end of November of 2008. It was found that Q-alone sampling configuration resulted in a higher OC than QBQ and Q-QBT by 14% and 28%, respectively due to no correction for positive artifact caused by adsorption of gas-phase OC onto the filter. A lower quantity of OC was collected from the backup quartz filter on QBQ than that from Q-QBT. A possible explanation is that the front quartz filter of QBQ was not fully saturated with gas-phase OC during the sampling period, allowing smaller amount of gas-phase OC to reach the backup quartz filter. The contribution of positive artifact to $PM_{2.5}$ mass was approximately 2.15 ${\mu}g/m^3$ which is equivalent to 6% in terms of Q-QBT sampling configuration. The positive artifact was found to be more dominated during summer than during winter, showing temperature dependence. It was concluded that Q-QBT sampling configuration offers less impact of positive artifact on ambient OC sampling than QBQ in quantification of OC.

Development and Evaluation of an Inexpensive Weighing Chamber for Particulate Filters (미세먼지 여지의 무게 측정을 위한 저비용 계량챔버 개발 및 성능평가)

  • Jun-Hyun Park;Ho-Jin Lim
    • Journal of Environmental Science International
    • /
    • v.32 no.2
    • /
    • pp.131-137
    • /
    • 2023
  • Filter and microbalance sensitivity in measuring fine particulate matter mass is greatly influenced by particulate properties and environmental factors. Temperature and humidity control inside a measuring chamber with a microbalance, and neutralization of static charges on filters are essential for consistent filter weighing. Commercial weighing chambers are expensive with a unit price of tens of millions won. This study developed an inexpensive weighing chamber for weighing fine particulate matter and evaluatedits weighing performance. A microbalance with 1 ㎍ precision was used to measure the weight of a filter. The microbalance was set in a transparent acrylic enclosure (100 × 60 × 65 cm3) equipped with temperature and humidity control equipments. Weighing performance of the chamber was examined using Teflon filters with or without different particulate sample types. Temperature and humidity were maintained at approximately 23.2±1.2 ℃ and 36.2±1.8℃ for 8 days, respectively.

Improvement of Band Pass Filter Using PBG and Aperture (Aperture와 PBG를 적용한 대역통과 여파기 성능개선에 관한 연구)

  • 이승재;서철헌
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.10A
    • /
    • pp.847-852
    • /
    • 2003
  • Apertures and PBG(Photonic Band Gap) has been employed on the ground plane in the coupled line filter simultaneously. In order to observe the maximum bandwidth, we used the line gap 0.2mm which is can be made in our lab. Band-pass filter type is four-stage coupled strip line filter. Teflon has been used for the substrate ($\varepsilon$$\sub$r/=3.2). The center frequency and the bandwidth are 2.18GHz and 230MHz, respectively. The bandwidth is broaden from 230MHz to 310MHz (80Mhz, about 34.7%) by aperture effect and harmonic frequencies are suppressed to 20-30dB by PBG effect. So the harmonic frequencies have been suppressed by the PBG effect and the bandwidth are broaden by aperture effect.

Inter-comparison of Two Aethalometers for Aerosol Black Carbon Measurements (대기 에어로졸 검댕입자 측정을 위한 두 aethalometer의 상호비교)

  • Jung, Jung-Hoon;Park, Seung-Shik;Yoon, Kwan-Hoon;Cho, Sung-Yong;Kim, Seung-Jai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.2
    • /
    • pp.201-208
    • /
    • 2011
  • Recently, a real-time, pocket-sized aethalometer (microAeth$^{(R)}$ model AE51) has been developed by Magee Scientific Inc. for measuring the concentration of black carbon in the atmosphere. In this study, two aethalometers, models AE-16 and AE-51, which measure the optical absorption of carbon particles at infrared 880 nm, were operated at time interval of 5-min between January 9 and February 10, 2010 at an urban site of Gwangju, to compare the accuracy of black carbon (BC) concentrations reported from the AE-51 model and to investigate reasonable sampling time of filter media in the AE-51. The air samples in the AE-51 and AE-16 models are collected on T60 (Teflon coated glass fiber) filter media (filter spot area: 0.07 $cm^2$) and quartz fiber roll-tape filter (filter spot area: 1.67 $cm^2$), respectively. Real-time measurement results indicate that when the filters were clean, the AE-51 BC was greater than or similar to the AE-16 BC data. However as the filter spots become darker, the AE-16 BC concentrations were higher than the AE-51 BC data and the difference in the BC concentrations from two AE models becomes gradually increased. Relative error in the AE-51 and AE-16 BC concentrations showed significance difference depending on used time of the filter in the AE-51 model, weather pattern, levels of air pollution, etc, ranging from 11.5% (used time of the filter in AE-51: 1,595 min) to 52.5% (used time of the filter in AE-51: 2,085 min). When considering the used time of one filter ticket in the AE-51 model and difference (or relative error %) between AE-16 and AE-51 BC concentrations, it is recommended that the standard sampling time per one filter ticket within the AE-51 model be less than approximately 24 hr (1,440 min) under the normal weather conditions except for severe haze and mist events.