• Title/Summary/Keyword: Technology leakage

Search Result 1,721, Processing Time 0.036 seconds

The Effect of Technology Infringement on Consumer's Attitude Change Depending on Brand Reputation: Focusing on the Under-dog Effect of Weak Brand (브랜드 명성에 따른 기술 침해에 대한 소비자의 태도 변화: 약자 브랜드의 언더독 효과를 중심으로)

  • Kim, Keon-Woo;Park, Do-Hyung
    • The Journal of Information Systems
    • /
    • v.27 no.4
    • /
    • pp.167-187
    • /
    • 2018
  • Purpose The purpose of this study is to confirm the factors for explaining the consumer behavior when occur patent litigation and technology infringement of each conditions which are brand reputation gap, technology importance and technology leakage attribution based on the Attribution Theory. Design/methodology/approach This study made a design of the research model by 2x2x2 factorial design deducted and performed 3-way ANOVA then analyzed 2-way AVOVA with brand reputation gap as center from technology importance and technology leakage attribution on the basis of the Attribution Theory. Findings According to the empirical analysis result, this study confirmed that consumer attitude has no difference regardless of technology leakage attribution when top-dog vs. under-dog situation and top-dog vs. top-dog situation. Also, this study confirmed that when under-dog infringe important technology, consumer show more positive attitude than the other. On the other hand, top-dog infringe important technology, consumer show more negative attitude than the other.

Economic impact of the technical security utilizing the inter-industry relations table (산업연관표를 활용한 기술보안의 경제적 효과)

  • Lim, Heon-Wook;Shim, Jae-Young
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.1
    • /
    • pp.99-106
    • /
    • 2017
  • Research on technology security has been limited to technology leakage prevention. Companies recognize technology security as an investment. so It is a passive situation for recruitment and equipment installation. Therefore, the amount of damage caused by the technology leakage is regarded as profit, The purpose of this study is to investigate the effect of technology security on the domestic economy by using the inter-industry relations table. The inter-industry relations table was created by Vasily Leontiyev. In 1960, the Bank of Korea made it for the first time in Korea. Korea introduced the ISMS in 2001 and conducted a study on the technology security economy. Through this study, we hope that technology security will be recognized as income, not investment.

Effect of Protective Compounds on the Survival, Electrolyte Leakage, and Lipid Degradation of Freeze-Dried Weissella paramesenteroides LC11 During Storage

  • Yao, Amenan A.;Wathelet, Bernard;Thonart, Philippe
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.8
    • /
    • pp.810-817
    • /
    • 2009
  • The effect of cryoprotectants (maltodextrin+glycerol) and cryoprotectants+antioxidant [ascorbic acid and/or butylated hydroxytoluene (BHT)] mixtures on the survival, electrolyte leakage, and lipid degradation of freeze-dried Weissella paramesenteroides LC11 during storage was investigated and compared with that of the control (cells without additives) over a 90-day storage period at 4 or $20^{\circ}C$ in glass tubes with water activity ($a_w$) of 0.23. The survival, electrolyte leakage, and lipid degradation were evaluated through colony counts, electrical conductivity, and thiobarbituric acid reactive substances (TBARS) content, respectively. The fatty acids composition was determined by gas chromatography, in both the total lipid extract and the polar lipid fraction, and compared with that of the control after the 90-day storage period. As the storage proceeded, increases in leakage value and TBARS content, as well as a decrease in viability, were observed. After 90 days of storage, the major fatty acids found in both the total lipid extract and the polar lipid fraction were palmitic (16:0), palmitoleic (16:1), stearic (18:0), oleic (18:1), linoleic (18:2), and linolenic (18:3) acids. The survival, leakage value, TBARS content and 18:2/16:0 or 18:3/16:0 ratio were the greatest for the protected strain held at $4^{\circ}C$. Cells with the cryoprotectants+BHT mixture showed the highest percentage of survival and 18:2/16:0 or 18:3/16:0 ratio in both lipid extracts, as well as the lowest leakage value and TBARS content after the 90-day storage period. Drying cells with the cryoprotectants+BHT mixture considerably slowed down polar lipid degradation and loss of membrane integrity, resulting in improved viability during storage.

An Advanced Embedded SRAM Cell with Expanded Read/Write Stability and Leakage Reduction

  • Chung, Yeon-Bae
    • Journal of IKEEE
    • /
    • v.16 no.3
    • /
    • pp.265-273
    • /
    • 2012
  • Data stability and leakage power dissipation have become a critical issue in scaled SRAM design. In this paper, an advanced 8T SRAM cell improving the read and write stability of data storage elements as well as reducing the leakage current in the idle mode is presented. During the read operation, the bit-cell keeps the noise-vulnerable data 'low' node voltage close to the ground level, and thus producing near-ideal voltage transfer characteristics essential for robust read functionality. In the write operation, a negative bias on the cell facilitates to change the contents of the bit. Unlike the conventional 6T cell, there is no conflicting read and write requirement on sizing the transistors. In the standby mode, the built-in stacked device in the 8T cell reduces the leakage current significantly. The 8T SRAM cell implemented in a 130 nm CMOS technology demonstrates almost 100 % higher read stability while bearing 20 % better write-ability at 1.2 V typical condition, and a reduction by 45 % in leakage power consumption compared to the standard 6T cell. The stability enhancement and leakage power reduction provided with the proposed bit-cell are confirmed under process, voltage and temperature variations.

A New method for the Calculation of Leakage Reactance in Power Transformers

  • Dawood, Kamran;Alboyaci, Bora;Cinar, Mehmet Aytac;Sonmez, Olus
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1883-1890
    • /
    • 2017
  • Transformers are one of the most precious elements of the electric power system. Stability and reliability of the electric power network mainly depend on the working of the transformer. Leakage reactance of the transformer is one of the important factors and accurate calculation of the leakage reactance is necessary for the transformer designers and electric distributors. Leakage reactance of the transformer depends on the geometry of the transformer. There are many different methods for the calculations of the leakage reactance however mostly are usable when the axial heights of the high voltage and low voltage windings are equal. When the axial heights of high voltage and low voltage windings are asymmetric most of the analytical methods are not reliable. In this study, a new analytical method is introduced for the calculation of the leakage reactance. Fourteen different transformers are investigated in this study and four of them are presented in this paper. The results of the new analytical method are compared with the experimental results. Other analytical and numerical methods are also compared with this new method. Results show that this method is more reliable and accurate as compared to the other analytical methods. The maximum relative error between short-circuit test and proposed method for these fourteen transformers was less than 2.8%.

Estimation of Probability Density Functions of Damage Parameter for Valve Leakage Detection in Reciprocating Pump Used in Nuclear Power Plants

  • Lee, Jong Kyeom;Kim, Tae Yun;Kim, Hyun Su;Chai, Jang-Bom;Lee, Jin Woo
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1280-1290
    • /
    • 2016
  • This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage.

A New Approach to On-Line Monitoring Device for ZnO Surge Arresters

  • Lee Bok-Hee;Gil Hyoung-Jun;Kang Sung-Man
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.131-137
    • /
    • 2005
  • This paper describes a new approach to the algorithm and fundamental characteristics of the device for monitoring the leakage currents flowing through zinc oxide (ZnO) surge arresters. In order to obtain a technique for a new on-line monitoring device that can be used in the deterioration diagnosis of ZnO surge arresters, the new algorithm and on-line leakage current detection device for extracting the resistive and capacitive currents using the phase shift addition method were proposed. The computer-based on-line monitoring device can sense accurately the power frequency leakage currents flowing through ZnO surge arresters. The on-line leakage current monitoring device of ZnO surge arresters proposed in this work has the high sensitivity compared to the third harmonic leakage current detection devices. As a consequence, it was found that the proposed leakage current monitoring device would be useful for forecasting the defects and degradation of ZnO surge arresters.

A Study on the Real-Time File Copy Leakage Prevention System (실시간 파일 복사 유출 방지 시스템에 관한 연구)

  • Kim, Ho-Yoon;Kim, Hyo-Jong;Lee, Jun-Yeon;Shin, Seung-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.217-219
    • /
    • 2021
  • With the development of ICT, the amount of data increases, and the technology of storing and processing becomes important. In this study, we study real-time file copy leakage prevention system to prevent leakage of important data in enterprises, public places, etc. As a research method, we propose a system that detects events in real time to prevent data leakage after analyzing data leakage cases and problems. The file leakage prevention system compares and analyzes with the existing EDLP system, and the proposed system reduces load and detects events. Future research requires research on the prevention of leaks through networks and various channels.

  • PDF

A Study on Evaluation Criteria and Procedures for Measuring Radiation Leakage of Aviation Security Equipment (항공보안장비 방사선 누출량 측정을 위한 평가 기준 및 절차에 관한 연구)

  • Kihyun Kim;Ye-Eun Jeong;Ye-Jun Kim;Yong Soo Kim
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.3
    • /
    • pp.435-444
    • /
    • 2023
  • Purpose: To attain advanced performance certification, safety aspects along with functionality and performance are essential. Hence, this study suggests radiation leakage assessment methods for aviation security equipment during its performance certification. Methods: Detection technology guided the choice of radiation leakage assessment targets. We then detailed measurement and evaluation methods based on equipment type and operation mode. Equipment was categorized as container or box types for establishing measurement procedures. Results: We've developed specific radiation leakage assessment procedures for different types of aviation security equipment, crucial for ensuring airport safety. Using these procedures allows efficient evaluation of compliance with radiation leakage standards. Conclusion: The suggested radiation leakage assessment method aims to enhance aviation security and reliability. Future research will focus on identifying risks in novel aviation security equipment detection technologies and establishing safety standards.

Design of a Novel Integrated L-C-T for PSFB ZVS Converters

  • Tian, Jiashen;Gao, Junxia;Zhang, Yiming
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.905-913
    • /
    • 2017
  • To enhance the zero-voltage switching (ZVS) range and power density of the phase-shift full-bridge (PSFB) ZVS converters used in geophysical exploration, an additional resonant inductor is used as a leakage inductance and a blocking capacitor which is equivalent to interlayer capacitance is integrated into a novel integrated inductor-capacitor-transformer (L-C-T). The leakage inductance and equivalent interlayer capacitance of the novel integrated L-C-T are difficult to determine by conventional methods. To address this issue, this paper presents accurate and efficient methods to compute the leakage inductance and equivalent interlayer capacitance. Moreover, the accuracy of this methodology, which is based on electromagnetic energy and Lebedev's method, is verified by an experimental analysis and a finite element analysis (FEA). Taking the problems of the novel integrated L-C-T into consideration, the losses of the integrated L-C-T are analyzed and the temperature rise of the integrated L-C-T is determined by FEA. Finally, a PSFB ZVS converter prototype with the novel integrated L-C-T is designed and tested.