• 제목/요약/키워드: Technology Transfer Grid

검색결과 102건 처리시간 0.023초

Voltage Distortion Approach for Output Filter Design for Off-Grid and Grid-Connected PWM Inverters

  • Husev, Oleksandr;Chub, Andrii;Romero-Cadaval, Enrique;Roncero-Clemente, Carlos;Vinnikov, Dmitri
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.278-287
    • /
    • 2015
  • This paper proposes a novel voltage distortion approach for output filter design based on the voltage transfer function for both off-grid and grid-connected Pulse Width Modulation (PWM) Inverters. The method explained in detail is compared to conventional methods. A comparative analysis is performed on an example of L and LCL-filter design. Simulation and experimental results for the off-grid and the grid-connected single phase inverter prove our theoretical predictions. It was found that conventional methods define redundant values of the output filter elements. Assumptions and limitations of the proposed approach are also discussed.

스마트그리드 AMI환경에서의 ID기반 인증기법에 관한 연구 (A Study on ID-based Authentication Scheme in AMI SmartGird Environment)

  • 김홍기;이임영
    • 정보처리학회논문지C
    • /
    • 제18C권6호
    • /
    • pp.397-404
    • /
    • 2011
  • 최근 기존의 단 방향 전력망 시스템에 정보통신기술을 접목한 스마트그리드 기술의 개발이 활발하게 이루어지고 있다. 스마트그리드의 핵심 인프라로 원격검침시스템인 AMI는 스마트미터에서 측정한 전력량을 상위 데이터 저장소인 MDMS에 전송한다. 스마트미터는 정보통신기술을 활용하여 전력데이터를 전송하고 있기 때문에 기존 보안위협을 포함한 추가적인 보안위협이 예상된다. 이는 소비자의 개인정보노출 및 산업시스템 마비 등의 손실이 발생할 가능성이 있다. 따라서 본 논문은 이러한 보안위협에 대응하기 위해 스마트그리드 환경에서 스마트미터와 MDMS간 그리고 각 가정의 디바이스와 MDMS간의 상호인증과 전력량 데이터 전송방식에 관하여 제안하였다.

MPTCP기반 Globus 서비스 적용을 위한 병렬 전송성능 모니터링 (Monitoring of Parallel Transfer Performance for MPTCP-based Globus Service)

  • 홍원택
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 추계학술대회
    • /
    • pp.354-356
    • /
    • 2021
  • 대용량 데이터의 공유 및 신속한 전송을 요구하는 과학응용 분야에서는 전송 성능을 높이기 위해 Globus/GridFTP와 같은 전송 어플리케이션에서의 병행성, 병렬성, 파이프라이닝 기법 등을 통한 성능 향상을 추구해 오고 있다. 본 논문에서는 비슷한 맥락에서 전송 프로토콜 계층에서 다중 경로 지원할 수 있는 Mptcp를 도입할 경우 기대할 수 있는 인터페이스 수의 증가 및 전송 스트림들의 병렬성 확장에 따른 전송성능 향상을 에뮬레이션 환경에서 실험하고 결과를 제시한다.

  • PDF

과학기술단지 활성화를 위한 지식/정보/기술 관리 및 전파에 관한 연구 (A Study on Management and Transfer of Knowledge/Information/Technology for Technopoleis Vitalization)

  • 성태경
    • Asia pacific journal of information systems
    • /
    • 제10권4호
    • /
    • pp.57-75
    • /
    • 2000
  • Most current literature on knowledge and technology transfer(Appropriability Model, Dissemination Model, and Knowledge Utilization Model), describe the process of transfer in details, but has limitation in terms of their application in contemporary high-tech industries since most studies have not provided plausible explanation on levels and factors affecting transfer of knowledge and/or technology. To overcome these limitations, the four levels of knowledge and technology transfer are suggested: Knowledge and Technology Creation(Level I), Sharing(Level II), Implementation(Level III), and Commercialization(Level IV). Comprehensive literature identifies sixteen variables affecting the process and results of knowledge and technology transfer. The survey results show four key factors in knowledge and technology transfer: Communication, Distance, Equivocality, and Motivation, Communication refers to the degree to which a medium is able to efficiently and accurately conveys task-relevant information and media while distance involves both physical and cultural proximity. Equivocality refers to the degree of concreteness of knowledge and technology to be transferred while motivation involves incentives for and the recognition of the importance of knowledge and technology transfer activities. Further analysis shows that there are four distinctive clusters and they show very contrasting characteristics in terms of four key factors. The careful mapping of the four clusters on the four key factors show very informative knowledge and technology transfer patterns, the Knowledge and Technology Transfer Grid. Finally, actions to increase communication interactivity and motivation, and to reduce cultural distance and equivocality are suggested.

  • PDF

중요부하를 갖는 계통연계형 인버터의 고조파주입에 의한 단독운전방지 기법 (Anti-islanding Method by Harmonic Injection for Utility Interactive Inverter with Critical Load)

  • 오형민;최세완;김태희;이기풍;이태원
    • 전력전자학회논문지
    • /
    • 제17권4호
    • /
    • pp.315-321
    • /
    • 2012
  • The utility-interactive inverter with critical loads should supply continuous and stable voltage to critical loads even during the grid fault. The conventional control method which performs current control for grid-connected mode and voltage control for stand-alone mode undergoes the critical load voltage variation during grid fault. The critical load voltage may have large transient when the inverter performs mode transfer after the islanding detection. Recently, the indirect current control method which does not have the transient state during not only islanding detection but also the mode transfer has been proposed. However, since the voltage control is maintained even during the grid-connected mode it is difficult to detect the islanding. This paper proposes an active anti-islanding method suitable for the indirect current control method which does not have NDZ(Non-Detection Zone).

다공성 물길의 진공동결건조과정에서 얼 및 물질전달 특성에 관한 연구 (A Study on the Heat and Mass Transfer Characteristics of Vacuum Freeze Drying Process for Porous Media)

  • c. s. song
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권6호
    • /
    • pp.1341-1352
    • /
    • 2001
  • Vacuum freeze drying process by which frozen water in a drying material is removed sublimation under vacuum condition, is now applied to various industrial field such as the manufacturing and packaging of pharmaceuticals in pharmaceutical industry, the drying of bio- products in bio-technology industry, the treatment of various quality food stuff in food technology, and so on. The Knowledge about the heat and mass transfer characteristics related with the vacuum freeze drying process is crucial to improve the efficiency of the process as well as the quality of dried products. In spite of increasing needs for understanding of the process, the research efforts in this fields are still insufficient. In this paper, a numerical code that can predict primary drying in a vial is developed based on the finite volume method with a moving grid system. The calculation program can handle the axis- symmetric and multi-dimensional characteristics of heat and mass transfer of the vial freeze drying process. To demonstrated the usefulness of the present analysis, a practical freeze drying of skim Milk solution in a vial is simulated and various calculation results are presented.

  • PDF

마이크로그리드에서 에너지 저장시스템을 위한 무순단 절체 기능을 갖는 계통연계형 인버터의 병렬운전 제어기법 (Parallel Operation Control Method of Grid-connected Inverters with Seamless Transfer for Energy Storage System in Microgrid)

  • 박성열;김주하;정아진;최세완
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.200-206
    • /
    • 2016
  • In the microgrid, inverters for energy storage system are generally constructed in a parallel structure because of capacity expandability, convenience of system maintenance, and reliability improvement. Parallel inverters are required to provide stable voltage to the critical load in PCC and to accurately share the current between each inverter. Furthermore, when islanding occurs, the inverters should change its operating mode from grid-connected mode to stand-alone mode. However, during clearing time and control mode change, the conventional control method has a negative impact on the critical load, that is, severe fluctuating voltage. In this study, a parallel operation control method is proposed. This method provides seamless mode transfer for the entire transition period, including clearing time and control mode change, and has accurate current sharing between each inverter. The proposed control method is validated through simulation and experiment.

건물의 3차원 구조체에 대한 전열해석 프로그램 개발 중 서로 다른 열전도율을 갖는 복합재질 3차원 구조의 비정렬 격자에 대한 전산해석 방법 (Numerical heat transfer analysis methodology for multiple materials with different heat transfer coefficient in unstructured grid for development of heat transfer analysis program for 3 dimensional structure of building)

  • 이주희;장진우;이현균;이용준;이규성
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.81-87
    • /
    • 2016
  • Purpose: Heat transfers phenomena are described by the second order partial differential equation and its boundary conditions. In a three-dimensional structure of a building, the heat transfer phenomena generally include more than one material, and thus, become complicate. The analytic solutions are useful to understand heat transfer phenomena, but they can hardly be applied in engineering or design problems. Engineers and designers have generally been forced to use numerical methods providing reliable results. Finite volume methods with the unstructured grid system is only the suitable means of the analysis for the complex and arbitrary domains. Method: To obtain an numerical solution, a discretization method, which approximates the differential equations, and the interpolation methods for temperature and heat flux between two or more materials are required. The discretization methods are applied to small domains in space and time, and these numerical solutions form the descretized equations provide approximated solutions in both space and time. The accuracy of numerical solutions is dependent on the quality of discretizations and size of cells used. The higher accuracy, the higher numerical resources are required. The balance between the accuracy and difficulty of the numerical methods is critical for the success of the numerical analysis. A simple and easy interpolation methods among multiple materials are developed. The linear equations are solved with the BiCGSTAB being a effective matrix solver. Result: This study provides an overview of discretization methods, boundary interface, and matrix solver for the 3-dimensional numerical heat transfer including two materials.

고정격자계에서 유한체적법을 이용한 진공동결건조 과정의 열 및 물질전달에 대한 연구 (A Fixed Grid Finite Volume Analysis of Multi-Dimensional Freeze Drying Process under Vacuum Condition)

  • Chi-Sung, Song
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.981-992
    • /
    • 2004
  • Freeze drying under vacuum condition is a complex process that involves simultaneous heat and mass transfer, sublimation of ice, and motion of sublimation front. Proper treatment of the motion of sublimation interface is crucial for an accurate prediction of the freeze drying process. Based on the enthalpy formulation that has been successfully used in liquid/solid phase change problems. a fixed grid method. streamlined for the freeze drying analysis. was developed in this study. The accuracy of the fixed grid method was checked by solving a one-dimensional tray freeze drying and a two-dimensional vial freeze drying problem and then comparing the results with those by the moving grid method. Finally. the freeze drying characteristics of two-dimensional slab and axis-symmetric cylinder was investigated using the fixed grid method.

Positive Feedback을 이용한 무효전력 P&O 단독운전 검출기법 (Reactive Power P&O Islanding Detection Method using Positive Feedback)

  • 이종원;박성열;이재연;최세완
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.410-416
    • /
    • 2022
  • A grid-connected inverter with critical loads uses mode transfer control to supply stable voltage to the load. An islanding detection method should also be used to quickly detect the grid fault and disconnect the inverter from the grid. However using the existing islanding detection method to detect islanding is difficult due to the small fluctuation of the voltage and frequency of the point of common coupling. This study proposes a reactive power P&O islanding detection method by using the positive feedback technique. The proposed method always injects a small variation of reactive power. When a grid fault occurs, the injected reactive power accelerates the reactive power injection reference. As a result, the reactive power reference value and the sensed reactive power become mismatched, and islanding is detected. Reducing the amount of real-time injected reactive power results in high efficiency and power factor. The simulation and experimental results of a 3 kW single-phase inverter are provided to verify the proposed islanding detection method.